| 1 | Dismantlingand removing 2.5 cm. thick A.S. flooringincluding stacking the useful materialsfor reuse and removing debris within 50 mt. leadwith all labour T & P etc. complete. |
| 2 | Dismantling brick or stonemasonry in lime or cement mortar above 3 mt. height including stacking the useful materialsfor reuse and removing debris within 50 mt. leadwith all labour T & P etc. complete. |
| 3 | Dismantling and removing doors windows and ventilatorsincluding removal of frame, hinges , fastening and stacking the same reuse and removing debriswithin 50 mt. leadwith alllabour T & P etc. complete. |
| 4 | Dismantlingand removing R.C.C. columns beamsslab staircase landing lintels including stacking the useful materialsfor reuse and removing debris within 50 mt. leadwith all labour T & P etc. complete. |
| 5 | Earthwork in excavation of foundation in hard soil within 50m initiallead and1.5mt. initial lift including shoring,shuttering, propping bullahs, piling,dewatering from foundation, supplying & working pumps & staking the excaveted materials away from the working areaincluding rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 6 | Supplying and filling in foundationand plinths with sand well watered and compactedincluding cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, watering, sundries, tools and plants, etc., completeas per the direction of the Engineer-in-charge. |
| 7 | Providing and laying plain cement concrete (1:3:6) in foundationusing 40 mm size black hard crusher broken granite metal of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes,cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,completeas per the direction of the Engineer-in-charge. |
| 8 | R.C.C. work of M-30 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hoisting and laying |
| 9 | Raft |
| 10 | Column |
| 11 | upto Ground Floor |
| 12 | upto 1st floor |
| 13 | upto 2nd floor |
| 14 | upto 3rd floor & machine room |
| 15 | Plinth beam |
| 16 | Lintel |
| 17 | Ground floor |
| 18 | First Floor |
| 19 | Second floor |
| 20 | Roof beam |
| 21 | Ground floor |
| 22 | First Floor |
| 23 | Second floor |
| 24 | Third floor |
| 25 | Roof slab |
| 26 | Terrace |
| 27 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications. |
| 28 | Ground floor |
| 29 | First Floor |
| 30 | Second floor |
| 31 | Third floor |
| 32 | Brick works with fly ash bricks in cement mortar ( 1:6 )in foundation & plinthincluding splays cutting circular moulding immersing brick under water for 6 hours watering curing with cost carriage royalty etc. complete. |
| 33 | Ground floor |
| 34 | First Floor |
| 35 | Second floor |
| 36 | Third floor |
| 37 | 12mm thick Cement Plaster (1:6) over Brick Masonry finished smooth in Ground Floor |
| 38 | Ground floor |
| 39 | First Floor |
| 40 | Second floor |
| 41 | Third floor |
| 42 | 16mm thick Cement Plaster (1:6) over Brick Masonry finished smooth in |
| 43 | Ground floor |
| 44 | First Floor |
| 45 | Second floor |
| 46 | Third floor |
| 47 | Painting two coats with any approved colour of weather seal coat to out side surface of wall in |
| 48 | Ground floor |
| 49 | First Floor |
| 50 | Second floor |
| 51 | Third floor |
| 52 | Supplying, fitting & fixing of Granite Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 53 | Ground floor |
| 54 | First Floor |
| 55 | Second floor |
| 56 | Providing, fitting and fixing ofM.S. Door, M.S Windows, M.S. Grills ,M.S. Grill Gateand CollapsibleGate with top and bottom rails inproper position including makingholes in walls, RCCstructure and wood work in proper position etc. and making good to the damages to wallsor RCC structures including mending, or cutting to sizes or grooves inwalls and fixing with CC (1:2:4)with hard black crusher broken granite stone chips of 12mmto 20mm(1/2\" to 3/4\") (20mm not toexceed 25% )with cost ,conveyance, royality, taxes of all materials, labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. |
| 57 | Wiringforlightpoint/fanpoint/exhaust fanpoint/callbellpointwith1.5sq.mm FRLS PVC insulated copper conductor single corecableinsurface/recessedmedium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing thepointwith1.5sq.mmFRLSPVC insulated copper conductor single corecable etc. as required. |
| 58 | i) Group C |
| 59 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizesofFRLSPVCinsulatedcopper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. |
| 60 | i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 61 | Wiringforlight/powerplugwith2X4sq. mmFRLSPVCinsulatedcopperconductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq.mmFRLSPVCinsulatedcopper conductorsinglecorecableforloop earthing as required. |
| 62 | SupplyingandfixingsuitablesizeGIbox withmodularplateandcoverinfronton surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outletand15/16Amodularswitch, connections etc. as required. |
| 63 | Supplying, installation, testing and commissioning of energy efficientLED battenluminarieswith20wattLEDlamp separately, madeofaluminiumdiecast housing complete with electronic driver and allotheraccessoriessuitableforoperation on 230v,50 Hz supply etc complete asrequired. |
| 64 | Supplying, installation, testing and commissioningofenergyefficientbulk head 10wattLEDlightfittingoverwashbasin complete with all accessories like electronic driverandotheraccessoriessuitablefor operationon230v,50Hzsupplyetc complete as required. |
| 65 | Supplying, installation, testing, commissioningof1200mm.BEE5Star rated ceiling fan with Brush less Direct current(BLDC) Motor,class of insulation :B,3 nos blades,30 cm long down rod,2 nos. canopies,shacklekit,safetyrope,copper winding,powerfactornotlessthan 0.9,servicevalue(CMM/W)minimum6.85 Airdeliveryminimum215CMM,350 RPM(tolerance as per IS:374-2019),THD less than 10%,remote or electronic regulatorunit for speed control and all remainingaccessoriesincludingsafety pin,nutsbolts,washers,temperaturerise=75 degree C(max.),insulationresistancemore than2megaohm,suitablefor230V,50 Hz,Supply,earthingetccompleteetcasrequired. |
| 66 | Supplying,installationof300mmsweep 1400 RPM light duty exhaust fan with louver shutter of suitable size in the existing opening, i/c making the hole to suit the size of the above fan, making good the damages, connection,testing,commissioningetc.as reqd. |
| 67 | Supplyingandfixingfollowingway,single pole and neutral, sheet steel, MCB distributionboard,240volts,onsurface/ recess,completewithtinnedcopperbus bar,neutralbusbar,earthbar,dinbar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 68 | i) 6 way , Double door |
| 69 | Supplyingandfixing5ampsto32amps rating,240/415volts,\"C\"curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 70 | i)Single pole |
| 71 | ii)Double Pole 40Amp |
| 72 | SH-III(Earthing Installation & Lightning Conductor) |
| 73 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 74 | SH-IV(Cabling & End Termination) |
| 75 | Supplyingofonelengthaluminiumarmoured PVC insulated/PVC sheathed XLPE power cable 1.1 KV LT ammended to IS 7098(Part 1) 1988 as required |
| 76 | 3.5 X 95 sqmm |
| 77 | Passenger cun Stretcher Elevator |
| 78 | Supplying, installation, testing and commissioning of 20 passenger cum Stretcher (1360Kg) lifts having contract speed of 1.00 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications. Original manufacturer among the approved makes i.e.OTIS/KONE/JOHANSON/PHYSON /ECE Location –Bhimabhoi Medical college Bolangir , Odisha.,Type – PM Gearless with Machine Room,Speed – 1.00 MPS,Floors - 3 floors (G+2 floors),Travel – 7 meters (approx.),Stops & Opening – 3 at the same side,Available Well Size: 2100MM (W) X 2850MM (D),Car Size: 1300MM (W) X 2400MM (D) X 2300 (H),Clear Door Opening: 1000 MM ,Machine Room Location : Top of the Hoistway ,Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay.,Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos.,Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant.Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C.,Type of Doors- Horizontal Sliding – Centre Opening ,Type of Doors- Horizontal Sliding – Centre Opening ,Landing Doors- Automatic and multi beam full height infra red detector automatic Telescopic opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. ,Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed,Braille system including all facilities for physically challenged persons.,Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works |