Tender For Construction Of Additional Work Phase-Ii Ganjam Haat And Commercial Complex At Brahmapur Part- B, brahmapur-Odisha

Brahmapur Development Authority has published Tender For Construction Of Additional Work Phase-Ii Ganjam Haat And Commercial Complex At Brahmapur Part- B. Submission Date for this Tender is 04-09-2023. Building Work Tenders in brahmapur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

39163609
Tender For Construction Of Additional Work Phase-Ii Ganjam Haat And Commercial Complex At Brahmapur Part- B
Open Tender
Indian
Odisha
brahmapur
04-09-2023

Tender Details

Construction Of Additional Work Phase-Ii Ganjam Haat And Commercial Complex At Brahmapur Part- B Works

Key Value

Document Fees
INR 10000 /-
EMD
INR 260000.0 /-
Tender Value
INR 2.60 Crore /-

BOQ Items

Name of Work:Construction of Additional work (Phase-II) Ganjam Haat & Commercial Complex at Brahmapur. (PART-B)
Sl. No. Item Description
1THIRD FLOOR
2Aerated Autoclaved fly ash (AAC) Bricks/masonory in filler /inside walls using A.A.C . Blocks of size 625mmx200mmx200mm Having compressive strength not less then 4N/mm square conforming to IS 2185(part-3)-2005 and IS - 6441-1972 In cement mortar of mix ( 1:6 )and screened and washed sand for moartar for use in super structre including splays cutting , circular moulding , corbelling chamfering and similar such type of works , watering & curing etc including cost conveyance , royalty loading , unloading and taxes of all materials ,cost of all labour scaffolding sundries ,T&P required for the works etc complete in all respect as directed by the Engineer -In-Charge
3Supplying ,Providing, lifting, hoisting and laying of Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 N / Square mm. in 150 mm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
4Lintel
5Roof Beam
6Roof Slab.
7Chajja
8Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer-In-Charge.
9Providing 12 mm. thick cement plaster with cement mortar of mix (1:6) in all floors at all height with screened and washed sharp sand for mortar to ceiling plaster of roof slab, staircase, landings, chajja and shelves etc. including roughening, scraping, chiseling, cleaning closed deep chipping with slurry treatment and finished smooth to all R.C.C surface including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P , scaffolding, watering and curing etc. complete in all respect as per specification and direction of Engineer-in-charge.. (External Surface)
10Providing 16 mm. thick cement plaster with cement mortar of mix (1:6) in all floors at all height with screened and washed sharp sand for mortar to ceiling plaster of roof slab, staircase, landings, chajja and shelves etc. including roughening, scraping, chiseling, cleaning closed deep chipping with slurry treatment and finished smooth to all R.C.C surface including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P , scaffolding, watering and curing etc. complete in all respect as per specification and direction of Engineer-in-charge.. (Internal Surface)
116mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
12Supplying, fitting & fixing of Kota Tiles of minimum 16 mm thickAbove 0.10 Sqm on 20mm thick bed of cement mortar (1:4) (1 cement : 4 course sand) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge.
13Providing, fitting and fixing Vitrified tile in floor of size 600x600 mm of approved make conforming to IS: 13755 laid on 20 mm thick cement mortar 1:4 (1 cement: 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In-Charge (for New work only)
14Supplying, fitting & fixing of Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 ofsize 60cm x 60cm coloured/printed series in dadoes, skirting and risers of steps oflaid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge.
15Providing and laying on terrace Non slippery full body homogeneousVitrified floor tiles 16mm thickness, siz-600x600 mm 1st quality ofSOMANY, JOHNSON, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights.
16Providing and fixing 20mm thick Above 0.40 sqm. Granite stone in steps (sample of Granite stone should be approved by EIC) for any locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 1 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
17Supplying ,Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface at all elevations including all material & labour complete at all floors and all heights as per the directionof Engineer-In-Charge .
18Supplying ,Providing & applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, including all material labour complete at all floors and all heights. (External Surface)at all elevations as per the directionof Engineer-In-Charge .
19Supplying,Providing & applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plastered wall surfaces to prepare the surface even and smooth at all elevations including all material & labour complete at all floors and all heights. as per the directionof Engineer-In-Charge .
20Providing & painting Two coats of Plastic Emulsion paint with 1st qualityapproved brand and manufacturer to give an even shade as per the instruction of Engineer - In- Charge at all elevations including all material & labour complete.. (Internal Surface)
21Providing and fixing seasoned sal wood work in frames at any locations including doors, windows, cupboard, clerestory and other framesfixing in position including cost of hinges, M.S. flat (30mm x 6mm) hold fasts lugs ordash fasteners of required dia and length as per drawing / specification, at all floors and all heights.
22Providing, fitting and fixing ofapproved make 32mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. Baan Code-LKYPDC527), 125x75x3mm (code no-7912) SS201 hinges, etc. make of (green play & century ) with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge.
23Providing and Fixing pristine white uPVC doors & windows make: Fenesta. Company must have own production facilities (extrusion & fabrication) & control the entire cycle from Extrusion to Installation to Post Sales Service. Providing and fixing of factory made uPVC Sliding window (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section1.6 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber. The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.2mm to 2.5mm. UPVC Windows & Doors must be fabricated with fusion welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III.All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated.Glass should be of 6mm single clear Glass with weather seal (EPDM/TPE). There would be Warranty of 10 years on Profile & one year on hardware from the date of installation. UPVC windows & doors must be installed by profile manufacturer only.Only manufacturer Waranty is aceptable .
24Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (Allsteel sections contractor"s own supply) at all floors and all heights.
25Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete at all floors and all heights.
26ROLLING SHUTTERS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover
27Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer"s specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor.
28Waterproofing Treatment :- Terrcae Roof Top Surface. Waterproofing Treatment of Terrace:- Ponding test first to be done, application of Nerolac-Perma Coat & Seal in 2 coats over the roof slab & continue over the parapet wall reinforced with Nerolac-Perma Non-Woven Polyester Fabric coving with 1:4 C.M admixed with Nerolac-Perma Plast-o-Proof STD @ 100 gram per 50kg cement over the joint terrace to parapet over bond coat Nerolac-Perma latex SBR (1:4:6) followed by a the protection screed (1:1.5:3) in panel of size 2 mtr x 2 mtr to drain the water towards the rain water pipe & finally filled the grooves 8mm x 10mm with Nerolac-Perma Polyseal (Poly Sulphide Sealant) complete as per manufacture specification & direction of engineer in charge. i)- Waterproofing of Roof Top--- ii)- Groove Filling & Sealing Exposed Screed plaster- iii)- Admixture Nerolac-Perma Plast-o-Proof STD- ( Rate Excluding Protection Plaster) N:B: All the waterproofing treatment shall be executed by an authorized applicator of our company. A written guarantee on non-judicial stamp paper shall be submitted by the applicator for a minimum period of 5(Five) years from the date of completion for the satisfactory performance of the entire waterproofing treatment system.
29II. Groove Filling & Sealing Exposed Screed plaster
30TILE EPOXY GROUTING Cleaning of surface with mechanical key and air blower should be used to clean the dead particle.All tiles ahall be fixed with a spacer of 8mm by tiles contractor and tile joint area shall be grout with nerolac perma R-Tone filler. Both side of tiles masking tape will be provided before application of epoxy tile shine polish will be applied for shining
31Tensile Fabric canopy structureDesign, Fabrication, Manufacturing, Assembly, Supply & installation of tensile Fabric and Supporting MS steel Structure as per drawing and manufacturers specification including all accessories, all necessary fixing arrangement etc. 950 GSM high Concentrated 902 S2 fabric form Ferrari including welding, and all fixing accessories, cables, supply and installation. Rates mentioned are for the surface area of the fabric. Final billing will be as per the actual surface area of the fabric. All curved cable catenary boundaries will be Considered as straight lines for the measurements
32SYNTHETIC GRASSProviding and fixing of 40mm thick artificial grass/ turf with 15900 density, double backing and 6+8 yarn. Made with virgin raw material and UV protected yarn to protect UV rays.
33TEXTURE PAINT. Providing and applying two coats unitile"s Royal/Rivera make in approved shade on a smooth cement sand plaster. The composition of the texture paint should consist of Acrylic Copolymer Resigns combined with Quartz, Silica,mineral aggregates, synthetic inorganic pigments, bactericide, fungicides and various other additives,giving the product water repellant properties. The first coat to be applied by brush or wool roller as a base coat, diluted with sufficient water and the final coat applied undiluted with trowel and then finished with acrylic trowel to obtain the specified grooves.The thickness of both coats dhould be 1.0 to 1.5 mm. The water repellency of the product is 86gm/m2 as per test method IS: 5410-1969.
34Gyp Board Ceilling :- Providing and fixing False ceiling as per Saint Gobain Specifications made of standard G.I. Sections and 12mm thick gyp board sheets inclusive of all hangers, edge members and other clips complete, with sheets fixed with proper Philip fastner by power drills and joints duly finished ensuring level in line, complete with putty, primer and painting of approved make and colour. Cost includes cutouts for electrical fittings, materials, labour, T&P etc complete as per direction of the Engineer-in-charge. (Basic Rate of Gypsum Board 12mm thk. Rs.303/ sheet).
35Supply and fixing of VOX - Infratop , false ceiling, of panel sizes of 340mmx 2700mm, resistant to moisture & water. It is durable, scratch resistant EN 438-2 p.25, non-flammable EN 13501-1 BS 476 part 7, imparct resistance, not less than 3J (23,03), reaction to fire C-s3:d0, in accordance with regulation (EU) no. 305/2011 under the sole responsibility of the manufacturer. Increases the sound insulation EN ISO 140-4 EN ISO 717-1 of the room, thermal conduction EN 12664, UV resistance EN ISO 4892-2 EN 20105-102, Global migration to food substances. No Emissions of harmful substances ISO 16000.The panels will be fixed flush fit with click lock system with appropriate aluminium / wood / ms profiles to ensure proper suspesion from the main structure.Should be non toxic substances, and made made of recycledmaterials and 100% suitable for recycling.Suitable edge profile 3050x40x19mm and intermediate profile of size 3050x76x12mm to be used as required.
36GRID CEILING WITH ANUTONESUBTEX NUBBY STEP EDGE Supply and Installation of Anutone 15 mm glassfiber steppe edge Glass fibre core ceiling tile of size 595 x 595 x 15mm having all edges encapsulated with chemical treated paint & having density 100-120 Kgs/ m3, weight 1.5 - 3.0 kg/m2 which is suspended by using 0.3mm thick and 15 mm wide pre coated metal T15/24 grid system. The technical parameters are as follows :Core - Glassfibre, Fire – Class 1 & P , Acoustics – NRC 0.95,Climate (OC RH) – 40, 95,Termite resistance ,Light reflectance – 85 %,Green (RC %) – 35, Hygiene (VoC, Clean room) – Low, Class 3 Strength, Load capacity (Kg) - Antisag. The T15/24 Grid system of 600 x 600 mm module shall include wall angle(WA15) with unequal flanges of size 14 x 20 x3000mm wide, length 3000mm, 0.43 mm thick fixed along the perimeter of wall with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15(MT15W36) having flange width 15mm /24 mm , height 32/38 mm and length 3600mm thickness 0.30 mm from the soffit with help of soffit cleat and wire at 1200mm c/c. Cross T15 (CT15W12) with flange width 15 mm, height 32 mm and length 1200 mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15 mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200 mm Cross T15 at 1200mm centers and in direction parallel to the Main T15. Anuton Subtex Nubby steppe edge of size 595 x 595 x 15mm thick shall be placed into the grid size of 600 x 600 mm. Ensure arrow marks behind subtex panels are orianted in one direction to achieve uniform shade. Test certificate will be submmited after procurement of materials.
37Glass Partition .Supplying ,Providing & fixing of Glass partition Dorma PT-90 Fittings with 12mm Toughened glass with Clear Silicone with Complete Installation & Direction of engineer-in-charge.
38Providing, Accessorice including cost of Material & labor with T&P etc. complete.(Excluding GST) **(INDICATIVE PRICE ONLY)DRY FLOWER ARRANGMENT
394" FLOWER VASE AT DINING
40BIG PLANTER
41SMALL PLANTER
42G.R.C. JALIProviding and fixing glass reinforced concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 - 4 kg per sq.ft .and color of M/S Unistone make or equivalent. The above weight and having at least 50% void space. The screens should be made from 53 grade white portlsnd cement manufactured by N.E.G JAPAN or equivalent, super plasticizers manufactured by BASF or equivalent, polymers manufactured by BASF or equivalent and U.V resistant synthetic inorganic pigments should be used for pigmentation manufactured by BAYFERROX (Germany) or equivalent. The matrial casting should take place in frp molds. The fixing of screens should be Dry fixing i.e. to be done with M.S Galvanized clamps, fixtures and fasteners of Hilti/fischer.
43MCM BRICK CLADDING.Supply of MCM Modified Clay Material - MCM A Series Brick - 240 x 60 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.
44INTERNAL P.H. & SANITARY WORK.
45GPH Works: Supplying allmaterials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer-in-charge.20 mm CPVC (Schedule-80) pipes (Sentini/Oriplast/Supreme)
4625 mm CPVC (Schedule-80) pipes (Sentini/Oriplast/Supreme)
4732 mm CPVC (Schedule-80) pipes (Sentini/Oriplast/Supreme)
4840 mm CPVC (Schedule-80) pipes (Sentini/Oriplast/Supreme)
4950 mm UPVC (Schedule-80) pipes(Sentini/Oriplast/Supreme)
50supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. Third Floor :- 250 mm thick wall
51Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer-in-charge.Third Floor :- 250 mm thick wall
52Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C.Third Floor
53Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer-in-charge.Supplying all materials, labour, T&P and fixing standard sized two wayBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with Flange Jaquar FLR-5041N
54Supplying all materials, labour, T&P and fixing standard sizedBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.15mm dia. nominal bore Long body Bib Cock Jaquar-CON-047KN. Third Floor
55Supplying all materials, labour, T&P and fixing standard sizedBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.15mm dia. nominal bore Short body Bib Cock Jaquar-CON-047KN.Third Floor
56Supplying all materials, labour, T&P and fixing standard sized15mm dia angular Stop cock of Hindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange Jaquar CON-059KN. Third Floor
57Supplying all materials, labour, T&P and fixing standard sized pillar cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock JaquarCat. No.- FLR -5011N.Third Floor
58Fixing of 25mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge.32mm dia brass or gun metal full way valve (shakti make)
59Fixing of 32mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge.32mm dia brass or gun metal full way valve (shakti make)
60Fixing of 40mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 ofof approved makeas per specification complete as per direction of Er-in-charge.40mm dia brass or gun metal full way valve(shakti make)
6115mm dia PVC connection pipe 450 mm long
6215mm dia CP Extention Nipple
63Providing and fixingcircular type stainless steeljalli (grating) with hole for floor /nahani trap etc complete as per specification and direction of the Engineer in charge. Third Floor
64Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of theEngineer-In-Charge.15mm dia CP Health Faucet of Jaquar 1.2mtr long, 8MM diaJaquar ALD-577.
65Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fixing mild steel ltubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting up to a height of 5 meters above ground level and placing the tank to the required position and providing 1st class K.B.Brick work in cement mortar (1:6) of 0.46mt. height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C.slab of size 1.60mt.x1.60mt. and 0.10mt. thick, R.C.C.beam of 0.25mt.x0.30mt. and 2.60mt. average length in cement concrete (1:2:4) using 12mm size h.g.chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of theEngineer-In-Charge. 2000 litre capacity water storage tanksin the roof of 1st floor.
66Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer-In-Charge.110mm diameter U-PVC SWR pipes(Oriplast type-B/Supreme)
67110mm U-PVCdoor Tee
68110mm U-PVC offset
69110mm U-PVCdoor bend
70110mm U-PVCplain shoe bend
71110mm U-PVCvent cowl
72110mm P-trap
73110mm U-PVCplain bend
74Supplying all materials,labour T&P and cutting holels through existing brick or laterite masonry wall for taking H.C.I pipes and fittings including making good the damages etc. all complete as per P.H.Specification and direction of theEngineer-In-Charge. 250mm to 375mm thick wall
75Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern of Hindware/Jaquar/Parryware with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer-in-charge.
76Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) of Hindware/Jaquar/Parryware duly embedded in cement concrete (1:4:8) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI "p" or "s" trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages etc all complete as per specification and direction of theEngineer-In-Charge.
77Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of Hindware/Jaquar/Parryware with integral "p" or "s" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge. EWC with "p" / S trap plain Hindware Cat No-20087 (S-10) Starwhite type, size-57x35x39 cm, seat cover for Hindware seat cover Premium starwhite.
78Supplying all materials, labour T&P and fixing wash basins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of theEngineer-In- Charge.Hindware ARIEL Wash Basin Size - 550mmx400x790mm, Cat.No. 10100 Starwhite & Hindware ARIEL Pedestal Cat -no- 11003 Starwhite.
79Counter Top Wash Basin Supplying all materials, labour T&P and fixing counter top Wash Basin Size - 570mmx420x195mm, Cat.No. FLS-WHT-5601 with all fittings as per direction of the engineer-in -charge.
80Supplying all materials, labour, T&P and fixing Flat back large pattern urinal of Hindware/Jaquar/Parryware the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls land making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Jaquar urinal with spreader hole and fixing accessories cat no-URS-WHT-13261H ,Size-355x340x535mm.
81Supply and fixing all materials, labour, T & P and providing urinal partition with italian collection(pastel)- size- 75x16.5x36.5 cm Cat no-61005 etc all complete as per direction of the Engineer-In-Charge. Make-Hindware.
82Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge.750mmx600mm size B.E.mirror (Alpina/Golden fish/Belgion)
83Supplying all materials, labour, T&P and fixing standard size glass-shelf of Hindware/Jaquar/Parryware with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification anddirection of the Engineer-in-charge.Jaquar glass shelf ACN-1171 N 600mm long
84Supplying all materials,labour, T&P and fixing standard sized CP towel rail24"of Hindware/Jaquar/Parryware complete withCP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer-In-Charge 25mmx600mm long CP towel rail (Jaguar make) ACN-1111NM.
85Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brasstowel ring complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge
86Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap case ofHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in chargeCP soap holder (Jaguar make) ACN-1131N.
87Supplying all materials, labour, T&P and fixing standard sized Robe Hook ofHindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Jaquar Robe hook AGA-BIV-31791
88Supplying all materials, labour, T&P and fixing standard sized Soap Dispensor ofHindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Soap dispense with Glass Bottle. CAN-1135N.
89Supplying & fixing of Matrix Set-1 Mat code-70002,EWC : (P-18) (WB 46X36 with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, one no hinged rail 76 cm and 4 nos of grab rail 60cm complete with all as per specification & direction of the Engineer in charge.
90Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 PSS UV of size 750x570x1350 mm height with water storage capacity 80 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC.
91Providing and fixing Salem Stainless steel A ISI (18/8) kitchen sink as per IS : 13983 with C.I. Brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required. a) Kitchen Sink with drain board Nirali makesize 510 X 1040 mm bowl depth 178 mm.
92Toilet Portion Civil Works
93Providing, fitting and fixingVitrified industrial floor tile of size 300x300 mm of approved make conforming to IS: 13755 laid on 20 mm thick cement mortar 1:4 (1 cement: 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In-Charge (for New work only)
94Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of NITCO, SOMANY, ASIAN, KAJARIAor equivalent approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per drawing & direction of EIC. In all floors and all heights .
95Supplying fitting, fixing Fatory made single leaf rigid FRP sandwich composite Door/Window shutter (allternatly GRP) of 32 mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised isopathalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) mpregnate with orthopthalic polysterskin. The thickness of the skins shall not be less than 1.5 mm Expanded polystyone(EPS) structural foam panel of 29 mm thickness and a density of 20 kg/cu.mtr shall be used as core material. Wooded reinforcement made of seaoned sal wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinfocements for fitting the metal fittings such as tower bolt, aldrop. hanles, etc. shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material. The material and process for manufacturing the door shutters shall be conform to RV- TIFAC composite design Center"s standards and specifications and the door shutters tested in conforming to IS: 4020-1998. The finish door shutter will be plain colour as per specification and diection of Engineer-In-Charge.
96Providing and fixing FRP Door frames Size (65mmx90mm)at any locations including doors, windows, cupboard, clerestory and other framesfixing in position including cost of hinges, M.S. flat (30mmx6mm) hold fasts lugs or dash fasteners of required dia and length as per drawing/specification, at all floors and all heights.
97EXTERNAL P.H. & SANITARY WORK
98Supplying all materials, labour, T & P and constructing Gully trap chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge.
99Supplying all materials, labour, T & P and constructing Inspection chamber of the following inside size with CC (1:3:6) mix using 40mm size h.g. metal on bed, Ist class Fly Ash brickwork in CM (1:6) , moulding and shaping the channel inside and benching with CC (1:2:4) using 12mm size h.g. chips, 12mm thick cement plastering (1:3) finished with punning to inside , cement flush pointing (1:3) to outside , R.C.C. cover slab in (1:2:4) using 12mm size h.g. chips with RCC man hole cover , earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering ,curing, conveyance of all materials to worksite , payment of royality , taxesetc. all complete as per aproved drawing , specification and direction of Engineer-in-charge.
100Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class-3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge.A) 110 mm dia AGRI pipes
101b) 160 mm dia AGRI pipes
102Supplying all materials, labour, T&P and constructing Man hole chamber of the following size withcement concrete (1:3:6) using 40 mm size HG metal on bed , !st class Fly Ash Brick work in CM (1:6) moulding and shaping the channel inside and benching with CC (1:2:4) mix using 12 mm size H.G chips,12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside ,RCC cover slab in (1:2:4) mix using 12 mm size H.G chips with RCC man hole cover , earth work in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksitepaymentof royalty, taxes etc. all completed as per approved drawing, specification and direction of Engineer-in-charge. a) Inside size 900mmx900mmx900mm
103addl depth of 0.30m upto 4.50m depth
104ELECTRICAL WORKSINTERNAL WIRING
105Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (Make of modular box,cover,switch & socket-Legrand Myrios/schneider opale/Eq) With 10Years Warenty
106Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Average Length: 3mtr
107Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group B
108Recessed wiring to Twin control light pointwith 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group C
109Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer-in-charge.
110Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group C
111Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge.
112Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 25Nos for Stage Light,3Nos For Aquaguard.
113Recessed wiringfor A.C/ Power socket outletwithindustrial type socket outlet,plug top and metal chained cover in sheet steel enclosure,20A/32A SP MCBincluding all accesories and connection as per direction of Engineer-in-charge.
114Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group B
115Recessed wiring to submain in 4 x 10 sq.mmFRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
116Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
117Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
118Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
119Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (For Switch Board Looping)
120Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40AFPMCB (10KA)Outgoings-10A SP MCB 10KA-12Nos.(Make-L&T/ Schneider/Legrand/Eq)
121Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way SPN Distribution Boards For BDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-32ADPMCB (10KA)Outgoings-6 A SP MCB- 1 Nos,16A SP MCB 1No
122Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 35 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
123Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq)
124END TERMINATIONSupplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. 3.5C x 35 sq.mm
1254C x 16 sq.mm
126PANEL TOP FLOOR PANEL with 80A 4P Change Over switch & 80A 4P MCB 25KA -1 No as incomer, 40A 4P MCB 10KA 3Nos,25A DP MCB 10KA 6Nos. with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB.
127EARTHING Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
128Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
129Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
130Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required.
131Lightning Arrester. Supply & fixing of lightning arrester of size 2.6" length made of 0.5"diameter copper rod, over which 5nos 5" length pointed copper rods of 0.3" diameter with suitable size of nuts and bolts.
132Supply & fixing of GI flat of 25mmx5mm size.
133Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
134FIXTURE Ceiling mounted indoortypebatten typeLED Luminaire with LED Lamp Similar to JAQUAR Cat No. LGLZ01X024XWor equivalent.
135Ceiling/ Wall mounted typeBULK HEADLuminaire withSimilar to JAQUAR Cat No.LBLK02X010XW or equivalent.
136Supply, Installation, testing and commissioning of 10W Mirror Light Similar to JAQUAR Cat no-LGLZ01X010XW/Equivalent.
137Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.
138Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
139Supply &fixing of 12W LED Down Light (S) similat to Jaquar Cat no-LNVE02R012SW/EquivalantWith all accessories.
140Supply, Installation, testing and commissioning of 18W Bulb with Angle holder.
141Supply &fixing of 5W LED Wall Decorative LIGHT similar to JAQUAR CAT NO-5386LL5H.INX/EquivalantWith all accessories.
142Supply, Installation, testing and commissioning of Ceiling mounted indoortypeRound RecessedLEDSimilar to JAQUAR Cat No. LNPE01R006XWor equivalent.
143Supply &fixing of LED POST TOPlight Similar to JAQUAR 340.PE8.NGG withall accessories.
144Supply, Installation, testing and commissioning of 70W High Bay light similar to JAQUAR cat no-LHBL090070GW / Equivalent. etcas required.
145Supply, Installation, testing and commissioning of Hanging Type LED Panel Light similar to JAQUAR cat no-LLTC01S040XN / Equivalent. etcas required.
146Supply, Installation, testing and commissioning of LED RGB Strip Light similar to JAQUAR cat no-LSTP03X008XM / Equivalent. etcas required.
147Supply, Installation, testing and commissioning of LED SPIKE Strip Light similar to JAQUAR cat no-LSPK68R103SW / Equivalent. etcas required.
148Supply, Installation, testing and commissioning of LED Wall Light similar to JAQUAR cat no-300.00.NGG / Equivalent. etcas required.
149Supply, Installation, testing and commissioning of LED Wall Light similar to JAQUAR cat no-LWWL01X208XW / Equivalent. etcas required.
150Supply, Installation, testing and commissioning of LED Wall Light similar to JAQUAR cat no-LWLL01X108XW / Equivalent. etcas required.
151TV /TEL & DATASupplying and fixing ofclip in type modular Telephone socket ISI markedmounted on G.I modular box with face plate & cover of suitable size ,including all accesories and connection as per direction of Engineer in Charge.
152Supplying and fixingof clip in type modular T.V. antenna socket ISI marked onmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
153Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required.
154Recessed wiring to television point withcable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in in existing surface / recessedPVC conduit as required as per direction of Engineer in Charge.
155Supplying and fixing of following sizes PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
156Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. ( Tel junction Box)
157Supplying & Commissioning of Telephone Hand Set.
158Supplying & installationof 10 pair KRONE make moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages.
159SAFETY EQUIPMENTSSupply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.
160Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.
161Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
162Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
163Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.
164FIRE FIGHTING SYSTEM
165M.S. Pipes with Hydrant AccessoriesProviding and Fixing in position black steel (M.S.) pipes bearing IS: 1239 (Medium Class) complete. welded or screwed joints as required, cutting and making good the walls and floors wherever required, complete in all respects (Internal and External works) (MAKE-JINDAL / Eqv Std )80 mm dia
166100 mm dia
167150 mm dia
168Fire Hydrant AccessoriesProviding and Fixing SS Fire Hydrant Valve of approved quality with 63 mm female, instant, oblique, single, outlet, 75 mm flanged inlet,ABS blank cap and chain (conforming to IS: 5290) complete with companion flange, bolts, nuts, rubber insertion/compressed asbestos, gasket etc. and painted in fire red colour.
169Providing and Fixing swinging, wall mounting type 30 mtrs long First Aid Hose Reel of approved quality conforming to IS : 884 and 19mm nominal bore, high pressure hose, FRP/GM shut off nozzle with 6mm outlet and bolts, nuts rubber insertion etc. painted in Fire red colour including cutting and making good the walls wherever required.( MAKE -Swastik/Fire shield/Kartar/Safeguard/Eqv Std )
170Reinforced Rubber LinedHose(RRL type-"A") ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneoustype CP 63mmdia. IS markedMaleandfemale SS couplings (IS:903)bound and riveted to hose pipe with G.I. rivets andwire.( MAKE -Swastik/Fire shield/Kartar/Safeguard/Eqv Std )
171Providing and Fixing in position SS short branch pipe of approved quality with 63mm male instantaneous type inlet and 15 mm outlet nozzle complete conforming to IS : 903 (MAKE -Swastik/Fire shield/Kartar/Safeguard/Eqv Std )
172Providing and fixing wall mounting type Fire Hose Box made out of 16 gauge mild steel sections and sheet, size 750 mm x 600 mm x 250 mm deep to accommodate each fire Hose pipes and branch pipe, glass fronted double door with 4 mm glass and lock, two keys, painted with enameled Fire red colour complete with bolts, nuts and cutting and making good the walls and floors wherever required.
173Providing fixing, testing and commissioning of Butterfly valve (PN1.0) with D.I disc, Hand lever operated, Slim line as per IS: 13095 ISI marked with flanges, bolts, nuts, rubber insertions/ compressed asbestos gasket etc. (MAKE-H.sarakar/Kratar/sant Eqv std)
174AutomaticadressableFire Alarm &Detection System Providing, fixing, testing and commissioning of smoke Detector etc
175Supplying, fixing, testing and commissioning of ,wall mounting loop powered addressable type hooter with all accessories ,
176Supplying, fixing, testing and commissioning of addressable manual call box made of polycarbonate with plastic break glass front and complete with
177Supplying, fixing of 2C X1.5 MM2 Copper un-armoured Cable, pvc conduits with fitting. (MAKE-FINOLEX / POLYCAB / HAVELLLS /MESCAB)
178FIRE EXTINGUISHERS (Make Safeguard/Intime/AFS/Fire tips/Fire Shield) Providing and Fixing carbon dioxide type Fire Extinguisher a) 4.5 kg. capacity
179Providing and fixing Water fire extinguisher fixed with bolts, nuts and washers complete in all respects. a) 6 kg. capacity
180EXIT SIGNAGE SITC of Self illuminated Autoglo exit Signs Fire Exit with one side arrow size.300x150mm
181PA system Providing and fixingof 20W Wall mounted speaker
182Supplying & fixing of 2CX1.5 sqmm wire
183SPRINKLER SYSTEM Supply,installation ,testing commissioning of MS mudium gradeClass pipe as per IS1239 :The pipes complete withasRate quoted shall include for painting of pipe with a coat of primer and two coats of synthetic enamel paint of approved colour / make for aboveground piping andlocal fire service department requirement complete including supply and installation of pipe supports, fasteners etc.Make-jindal150 mmdia
184100 mmdia
18580 mmdia
18650mm dia
18732mm dia
18840mm dia
18925 mmdia
190supply ,installation,commisoning of 60degre sprinkler with fittings
191Supply,installation ,testing commissioning of EPDM 150 mm butterfly valve
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy