Bhakra Beas Management Board-BBMB has published Tender For Repair Of Existing Police Barrack At Silt Ejector And Police Barrack At Seigal Along Sundernagar Hydel Channel Alongwith Repair And Renovation Of Existing Silt Ejector Building At Bbmb Sundernagar. Submission Date for this Tender is 11-09-2023. Barrack Tenders in sundernagar Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | ScrapingWhite wash and colour wash |
2 | Preparation of plastered or concrete surfacefor painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
3 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed |
4 | Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
5 | White washing (two or more coat) |
6 | Nicking cement concrete surface (over 28 days old including preparation and laying slurry. |
7 | Providing and laying levelling course for water proofing on roof slabs including preparation of surface with applying a slurry coat of neat cement using 1.75Kg/sqm. Of cement admixed with water proofing compound confirming to IS 2645 and as approved by Engineer in charge including adjoining walls upto 300mm height and laying 50mm average thick cement concrete1:2:4 with stone ballast or shingle admixed with water proofing walls upto 300 heightby finishing the surface with 20mm thick joint less cement mortar mix 1:4 (1 cement: 4 sand) including sufficied curing etc. copmplete flooded with water for two weeks for curing and final test complete etc. |
8 | Water proofing treatment of roof slab with high perfoermance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats (Dr Fixit Roofseal flex- Packaging size: 12.5 Kg (7.5 Kg powder + 5Kg polymer)/ equivalent water proofing solution). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
9 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled a) Doors of area 3 sqm and below |
10 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled b) Windows of area 3 sqm and below |
11 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick |
12 | Wire gauze door shutter with Kail wood without springs housed in chowkats(Single Leaf) 35mm thick |
13 | Wire Gauge Imported teak wood door shutter without springs housed inchowkats. (a)35 mm thick |
14 | Fixing wire gauze out side the clerestory window including teak wood chowkats and cover molding |
15 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect iii)"Fixing of glass pane 4mm thick |
16 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) (i) For shutter area up to 0.50 sqm |
17 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) (ii)For shutter area above 0.50 sqm |
18 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :A)300mm x 16mm |
19 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
20 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
21 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
22 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). |
23 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
24 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
25 | Chowkats of Imp. Teak Wood confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) Double Rebate (60mm x 150mm) (60mm x 150mm) |
26 | Kail wood doors shutter and window shutter panelled, glazed or glazed and panelled including hinges screws chokes cleats and cords etc. complete Fixed in position (Single Leaf) 35mm thick |
27 | Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
28 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 450mmx300mm |
29 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 15mm i/d |
30 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 15mm i/d |
31 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
32 | Providing and fixing PVC Cistern 10 Ltr. Capacity ISI marked IS 7231:1994( size 32.5x47.6x15.5 cm) of approved make(to the approval of the Engineer-in-charge) including PVC fittings complete |
33 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
34 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects |
35 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete |
36 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect C.P. brass Bib cock long nose/ long body foam flow without flange |
37 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect C.P.brass 15mm Concealed stop cock with flange. |
38 | SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. (4Module Box), 16Amp. Universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown Bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- "i) "Wiring fan point (Without fan box) |
39 | ii) "Wiring light point |
40 | iii )"Wiring call-bell point |
41 | v) Wiring 6Amp. wall socket point |
42 | vi) "Wiring 16/20Amp. power plug control point |
43 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable up to 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- "Overall size 4sq.mm (Un-sheathed) |
44 | Overall size 6sq.mm (Un-sheathed) |
45 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- "ii) MCB Single Pole 6-32amp. (10kA, Curve-C) |
46 | i) MCB Single Pole 0.5-4amp. (10kA, Curve- C) |
47 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB"s/ RCBO"s/ RCCB"s: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper bus bars, shrouded neutral bars, earth bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&N distribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-"iv) SP&N Double Door Distribution Board 16 |
48 | Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- xvi) MCB Four Pole 50, 63amp. (10kA, Curve-C) |
49 | DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points including necessary repairs to wall etc:- i) Fan, light or call bell point |
50 | ii) Wall Socket/ power Plug Point |
51 | iii) Removal of existing Tube fitting etc. |
52 | 34.10 C XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (xxxvi) Overall size 10sq.mm (4Core) Un-armoured (On-Surface) |
53 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. )copper thimble with suitable size steel bolt, washers & double nut) with 30cm x60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) aroundhole of excavation Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 19.50 metre (63.96 feet) below ground level (up to 23metre in Length) with G.I. pipe 20mm dia |
54 | Exhaust Fan |
55 | LED Tube Fixture 20 Watt |
56 | Three Phase Energy meter 20 Amp |