All India Institute Of Medical Sciences-AIIMS has published Tender For Repair Of Sunken Slab In The Area Of Medical College, Nursing College, Hostel Complex And Auditorium Building, Aiims Raipur. Submission Date for this Tender is 31-08-2023. Auditorium Construction Tenders in raipur Chhattisgarh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
2 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
3 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
4 | Extra for providing and mixing water proofing material in cement concretework in doses by weight of cement as per manufacturer"s specification. |
5 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : |
6 | Cement mortar 1:6 (1 cement : 6 Coarse sand) |
7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
8 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
9 | 12 mm cement plaster of mix : |
10 | 1:6 (1 cement: 6 fine sand) |
11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
12 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
13 | Two coats |
14 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
15 | With cement mortar 1:4 (1 cement : 4 fine sand) |
16 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin- Charge. (a) Internal Work- Exposed on wall |
17 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
18 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
19 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
20 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
21 | In cement mortar |
22 | Dismantling tile work in floors, walls and roofs laid in cement mortar including stacking material within 50 metres lead. |
23 | For thickness of tiles 10 mm to 25 mm |
24 | Dismantling C.I. or asbestos pipe with fittings and clamps including stacking the material within 50 metres lead : |
25 | 75 to 80 mm dia pipe |
26 | 100 mm dia pipe |
27 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
28 | Providing and fixing soil, waste and vent pipes : |
29 | 100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
30 | 75 mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
31 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
32 | 75 mm dia pipe |
33 | 100 mm dia pipe |
34 | Providing and fixing single equal plain junction of required degree : |
35 | 100x100x100 mm Sand cast iron S&S as per IS - 3989 |
36 | 75x75x75 mm Sand cast iron S&S as per IS - 3989 |
37 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : |
38 | 100 mm Sand cast iron S&S as per IS - 3989 |
39 | 75 mm Sand cast iron S&S as per IS - 3989 |
40 | Providing and fixing collar : |
41 | 100 mm Sand cast iron S&S as per IS - 3989 |
42 | 75 mm Sand cast iron S&S as per IS - 3989 |
43 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
44 | 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 |
45 | 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 |
46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
47 | 20 mm nominal dia Pipes |
48 | 25 mm nominal dia Pipes |
49 | 32 mm nominal dia Pipes |
50 | 40 mm nominal dia Pipes |
51 | 50 mm nominal dia Pipes |
52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
53 | 20 mm nominal dia Pipes |
54 | 25 mm nominal dia Pipes |
55 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
56 | 15 mm dia nominal bore |
57 | 20 mm dia nominal bore |
58 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
59 | 25 to 40 mm nominal bore |
60 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
61 | 25 mm nominal bore |
62 | 20 mm nominal bore |
63 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
64 | 15 mm nominal bore |
65 | 20 mm nominal bore |
66 | 25 mm nominal bore |
67 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
68 | 15 mm nominal bore |
69 | 20 mm nominal bore |
70 | 25 mm nominal bore |
71 | Providing and fixing PTMT grating of approved quality and colour. Circular type |
72 | 100 mm nominal dia |
73 | 125 mm nominal dia with 25 mm waste hole |
74 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
75 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) |
76 | Epoxy injection grout in concrete/RCC work of approved make |