Construction Of Warehouse For Storage Of Electronic Voting Machines ( Evms ) At Dari Dharamshala In Distt. Kangra, Hp ( Sh- Providing Wiring For Additional Rooms In Basement And Lift Machine Room, Lift Pit Area And Other Left Out Area Therein ), dharamshala-Himachal Pradesh

Public Works Department-PWD has published Construction Of Warehouse For Storage Of Electronic Voting Machines ( Evms ) At Dari Dharamshala In Distt. Kangra, Hp ( Sh- Providing Wiring For Additional Rooms In Basement And Lift Machine Room, Lift Pit Area And Other Left Out Area Therein ). Submission Date for this Tender is 16-08-2023. Godown Tenders in dharamshala Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39054594
Construction Of Warehouse For Storage Of Electronic Voting Machines ( Evms ) At Dari Dharamshala In Distt. Kangra, Hp ( Sh- Providing Wiring For Additional Rooms In Basement And Lift Machine Room, Lift Pit Area And Other Left Out Area Therein )
Open Tender
Indian
Himachal Pradesh
dharamshala
16-08-2023

Tender Details

Construction Of Warehouse For Storage Of Electronic Voting Machines ( Evms ) At Dari Dharamshala In Distt. Kangra, Hp ( Sh- Providing Wiring For Additional Rooms In Basement And Lift Machine Room, Lift Pit Area And Other Left Out Area Therein )

Key Value

Document Fees
INR 350 /-
EMD
INR 12000.0 /-
Tender Value
INR 5.96 Lakhs /-

BOQ Items

Name of Work: Construction of warehouse for storage of electronic voting machines (EVMs) at Dari Dharamshala in District Kangra (H.P.) (SH: Providing wiring forAdditional rooms in Basement and Lift Machine Room, Lift Pit Area and other left out area therein.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Make: KEI/Plaza/Anchor/SCI/ Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius) /L&T(Entice).
2Group C.
3Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single core cable in surface/ recessed steel conduit as required. Make:KEI/Plaza/Anchor/SCI
42 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
52 X 4 sq. mm + 1 X 4 sq. mm earth wire
62 X 6 sq. mm + 1 X 6 sq. mm earth wire
7Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make:KEI/Plaza/Anchor/SCI
83 x 2.5 sq. mm
9Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.Make :- L&T /Legrand/Schenider
102 Module (75mmX75mm)
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make: Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
12Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make:Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius)/L&T(Entice).
13Supplying and fixing extra down rod of 60 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
14Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
15Single pole 6 Amp(Make:- Schneider/ Legrand/L&T)
16Single pole 16 Amp(Make:- Schneider/ Legrand/L&T)
17Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1840 Amps. (Make:-Schneider/ Legrand/L&T)
19Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2040 Amps. (Make:-Schneider/ Legrand/L&T)
21Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
22Double door-6 way (Make:-Schneider/ Legrand/L&T)
23Double door-8 way (Make:-Schneider/ Legrand/L&T)
24Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:- (Make:- KEI/ Plaza/SCI/Havells).
25Armoured cable 25 sq. mm (3.5 core)
26Armoured cable 50 sq. mm (3.5 core)
27Armoured cable 70 sq. mm (3.5 core)
28Providing and laying of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- (Make:- KEI/ SCI/Plaza/Havells)
29Armoured cable 50 sq. mm (3.5 core)
30Armoured cable 70 sq. mm (3.5 core)
31Providing and fixing GI louvers/shutters complete with frame for exhaust fans of all sizescomplete with fixing including making good the damages etc. as required complete in all respects.
32Providing and Fixing of LED CRCA Powder Coated Box Type Channel with Pro LED Lamp Suitable for mounting 1 X 18 W LED Tube T8 type having minimum system efficacy of 100 lm/W, P.F.>0.95 with THD<10% ,CCT 6500 K,CRI 80,Surge Protection 2 Kv.The LED with Useful life of 50000 Hrs at L70 with five years warranty.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Makes:- Philips /Wipro/Havells/Bajaj.
33LED fixture 1x18 Watt Surface Mounted 4 Feet Box Type Channel with Pro LED Lamp
34Supplying and fixing of following sizes PVCpipes 4 KGF/CM along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- Make:- Finolex/ Diplast/PolyFit
3575 mm dia.
3690 mm dia.
37Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make: Schneider/ Legrand/L&T.
38MCCB 100 Amp 18KA
39Supplying and fixing of Electrical Panel Rubber insulation mat of suitable size and thickness upto 12.5mm with chequered holes/ solid sheet with insulation voltage resistance of 2kv/sqm etc. as required complete in all respects.
40Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required Make: Schneider/ Legrand/L&T/Havells.
41200 amps. TPN, On Load Change over switch (Panel mounted type)
42Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Schneider/ Legrand/L&T.
4332 Amp Triple Pole and Neutral
44Supplying and fixing of following sizes of PVC conduit of medium class with 1.4 mm thickness along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- (Make: BEC Plast/Anchor/PolyFit.
4525 mm. dia
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail