| 1 | Supply,installation, testing and commissioning of Gas release panel-4 zone, 1 gas release circuits to complete the job in all respect to the entire satisfaction of engineer-in-charge of work . Make: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 2 | Supply,installation, testing and commissioning of Manual release switch for Gas Release to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 3 | Supply ,installation , testing and commissioning of Abort switch for gas cooper release to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 4 | Supply ,installation , testing and commissioning ofphotoelectricSmoke detector for gas release to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL , EDWARDS / G.S.T . |
| 5 | Supply ,installation , testing and commissioning of heavy Sounder strobe for gas release to complete the job in all respect to the entire satisfaction of the Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL, EDWARDS / G.S.T / FIRE SAVER. |
| 6 | Supply ,installation , testing and commissioning of 120 Lt PESO approved cylinder assembly to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work Make: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 7 | Supply ,installation , testing and commissioning of Agent - FK 5-1-12 ( Fluoro Ketone ) - FK 1230to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 8 | Supply ,installation , testing and commissioning of Primary cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER .Electric Cum Manual Actuator |
| 9 | Supply ,installation , testing and commissioning of Primary cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER .2`` Discharge hose flexible EPDM Quality with Squeez grip handle |
| 10 | Supply ,installation , testing and commissioning of Primary cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . Warning Sign Board with photo Luminiate ink size 2 feet * 1 feet |
| 11 | Supply ,installation , testing and commissioning of tertiary Cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . Pnuematic actuator |
| 12 | Supply ,installation , testing and commissioning of tertiary Cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . 2`` Discharge hose flexibleEPDM Quality with Squeez grip handle |
| 13 | Supply ,installation , testing and commissioning of tertiary Cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . flexible actuation hose EPDM Quality 15` |
| 14 | Supply ,installation , testing and commissioning of tertiary Cylinder with accessories to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . Master Cylinder adaptor kit complete Fitting |
| 15 | Supply ,installation , testing and commissioning of elbow connectors to complete setin all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 16 | Supply ,installation , testing and commissioning of Manifold check valve 2``to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of workMake: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 17 | Supply ,installation , testing and commissioning of 2` discharge nozzelbrass with heavet chek Valve I.S.I. , I.S.O Markto complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work Make: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 18 | Supply ,installation , testing and commissioning of cylinderheavy strap for 120 and 140 lt cylinder to complete set in all respect to the entire satisfaction of Engineer-in-Charge of work Make: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 19 | Supply ,installation , testing and commissioning of discharge pressure switch to complete set in all respect to the entire satisfaction of Engineer-in-Charge of work Make: SAVEMAX / HONEYWELL / FIRE SAVER . |
| 20 | SITC of PIPE M.S VALDED jindalmake )standard class make with Complete AssessriesLike T-Band , Paint (mtrs) MAKE JINDAL / PARKASH SURYA / RAVINDRA . 80 mm dia |
| 21 | SITC of PIPE M.S VALDED jindalmake )standard class make with Complete AssessriesLike T-Band , Paint (mtrs) MAKE JINDAL / PARKASH SURYA / RAVINDRA . 25 mm dia |
| 22 | SITC of PIPE M.S VALDED jindalmake )standard class make with Complete AssessriesLike T-Band , Paint (mtrs) MAKE JINDAL / PARKASH SURYA / RAVINDRA . 50 mm dia |
| 23 | Supply of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications. Makes: EdwardsEST3-CB-14 /Honeywell /GST . |
| 24 | Supply of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Makes: Edwards /Honeywell /GST . |
| 25 | Supply ofintelligent Analog Addressable type Manual Call Point having plastic body Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approvedMakes: Edwards /Honeywell /GST . |
| 26 | Supply of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes: Edwards /Honeywell /GST . |
| 27 | Supply ofAddressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS. Makes: Edwards /Honeywell /GST . |
| 28 | Supply ofIntelligent Analog Addressable type Response Indicator light Makes: Edwards /Honeywell /GST . |
| 29 | Supply ofUL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring connectionMakes: Edwards /Honeywell /GST . |
| 30 | SITC ofAnalog Addressable type Active Repeater fire alarm panel with LCD Display, having controls for reset, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Makes: Edwards /Honeywell /GST . |
| 31 | Supplyof Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with iron hook chain and fastener.Make Pearl//Omex/Savemax. |
| 32 | Supplyofminimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc.. Make: National/Kheraj |
| 33 | Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall/ ceiling etc. i.e. cost of PVC bends, inspection box and all other material reqd to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make: BEC, AKG, Ravindra / Diplast |
| 34 | PVC unsheathed copper size 1.5 sq mm single core Make Grandly/ Plaza/ Finolex. |
| 35 | Supply of 17 U Standard rack to place all Av equipment Make D-Link, Comrack/ CP plus. |
| 36 | Mechnical f`oam Type Fire Extinguisher50 Leter capacity withOUTSIDE CYLINDER , CO2 CYLINDER 1 KG CAPACITY for AboveAFFF foam compound forextinguisger , 3000 mls capacity combine . Make Safex / Ceasefire / Minimax . |
| 37 | 3 Meter Rubber pipe with EPDM Quality with squzeer grip nozzlefor Jet length I.S.I Mark Make Safex / Ceasefire / Minimax . |