| 1 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 2 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed. |
| 3 | Taking down roof trusses, coupled rafters or trussed beams of clear spanupto 4 mtrs complete all as specified and as directed. |
| 4 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 5 | Dismantling timber fillets,rails,posts,rafters,purlins,etc in un framed work under 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 6 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles,removing debris beyond the premises, complete all as specified and directed. |
| 8 | M&L RCC M-25 (Design mix)(using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 9 | Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels. Cantilevers, shelves including supports, overhangs, etc also splays between floor and beam etc for rough finished flat surfaces of cocrete complete all as specified and as directed. |
| 10 | M&LBrickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed. |
| 11 | M&L Brickwork with subclass ‘B’ bricks, straight for curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed. |
| 12 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge. |
| 13 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed by the Engineer-in-Charge. |
| 14 | M&L Pressed steel frames (125 x 60mm)for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and as directed by the Engineer-in-Charge. |
| 15 | M&L PCC (1:3:6), type C-1, (using 20 mm graded crushed stone aggregates) as in bed block, blocks for holdfasts,filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed. |
| 16 | S&F 30 mm thick,Flush shutters,solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats complete all as specified and directed. |
| 17 | S&F 35 mm thick, second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified and directed. |
| 18 | S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 19 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified and directed. |
| 20 | S&F 300 mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 21 | S&F Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed withsteel wire staples complete all as specified and directed. |
| 22 | S & F Aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and directed by Eng-in-charge. |
| 23 | M&L Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights complete as per manufacturers specifications,as specified and as directed by Engineer – in - Charge. |
| 24 | M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc,complete as per manufacturers specifications,as specified and as directed by Engineer – in - Charge. |
| 25 | M&L TMTbars 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 26 | All as per Item 25 above, but6 mm to 8 mm dia complete all as specified and directed. |
| 27 | All as per Item 25 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders,etc complete all as specified and directed. |
| 28 | S&F Structural steel work intubular trusses (hollow square/ rectangular section) etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923-1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed. |
| 29 | S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.-240 complete all as specified and directed. |
| 30 | S&FRolled mild steel in plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachmentconforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 31 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 32 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm long and n. exc 10 cm long and diameter of neck 5 to 10 mm ,complete all as specified and directed. |
| 33 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 34 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated Plain steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in Evas roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 35 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing debris beyond the premises,complete all as specified and directed. |
| 36 | Demolition of stone slabs and tiles of any description or thickness in floors,aprons,etc including removing debris beyond the premises complete all as specified and as directed by Eng-in-charge. |
| 37 | M&L 75 mm thick PCC (1:3:6)type C-2 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete all as specified and as directed.. |
| 38 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and directed. |
| 39 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick renderingin CM (1:4) for vertical surfaces such as skirting etccomplete all as specified and as directed. |
| 40 | M&L40 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) asin floors, finished even and smooth, using extra cement complete all as specified and directed. |
| 41 | M&L for Glass dividing strips, 3 mm thick 38mm wide and inserted in position, conform to design complete all as specified and directed |
| 42 | M&L Rendering 10.mm thick in CM (1:6) on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement complete all as specified & directed. |
| 43 | M&L Rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layerfinished fair and even with mixing water proofing compound to top layer as per manufacturers instruction complete all as specified and directed.Note: WPC will be measured separetely. |
| 44 | Supply only Integral water proofing compound of approval brand complete all as specified and directed. |
| 45 | M&L Preparation of new plastered surfaces of walls andapplying 1 mm thick thin layer of exterior wall care puttyand finally applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 46 | M&L Preparation of new plastered surfaces of walls andapplying thin layer of wall care putty of 1 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 47 | M&L Preparing new wood & wood basd surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 48 | M&L Preparation of newsteeland iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide primer completeall as specified and directed. |
| 49 | M&L Preparation of old painted surfaces of steel of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 50 | S&F Stainless steelIst grade kitchen plate rack of size 31x30x10 inches fixed with gypsum screws with rawl plugs complete all as specified and directed. Make: Model No. P-446 of Prayag or equivalent model inBlue Star or Silver Shine or Suyog. |
| 51 | Taking down copper/aluminium point wiring, (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed. |
| 52 | M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including concealed type rigid non-metallic PVC conduitof suitable size but not less than 20mm dia , with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc.and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire for one light point controled by one one way 5 Amp switchcomplete all as specified and directed. Note :- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.(ii) The wiring shall be done strietly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. |
| 53 | All as per Item No.52 above,butOne Fan point controlled by one one way 5 Amp switch, complete all as specified and directed. |
| 54 | All as per Item No.52 above,butOne 5 pin socket outlet 5 Amps on independent board, complete all as specified and directed. |
| 55 | All as per Item No.52 above,butOne 5 pin socket outlet 5 Amps on same board, complete all as specified and directed. |
| 56 | All as per Item No 52 above butusing 2.5 sq mm, copper conductor with 2.5 sq mm, PVC insulated single core cable for earth continuity conductorfor for one 15 Amps socket outlet.,complete all as specified and as directed.. |
| 57 | S&F Modular switch one way 6 Amps 1 module including Modular PVC cover plate with frame & metal flush box of suitable size all as specified and directed. |
| 58 | S&F Modular socket outlet, 5 pin6 Amps flush type 2 module including Modular PVC cover plate with frame & metal flush box of suitable size all as specified and directed. |
| 59 | S&F Modular switch one way 16 Amps 1 module including Modular PVC cover plate with frame & metal flush box of suitable size all as specified and directed. |
| 60 | S&F Modular socket outlet, 5 pin 6/16 Amps flush type 2 module including Modular PVC cover plate with frame & metal flush box of suitable size all as specified and directed. |
| 61 | S&F Modular ceiling fan regulator,electronic type,step type 5 speed A/C, 230 voltsincluding Modular PVC cover plate with frame & metal flush box of suitable size all as specified and directed. |
| 62 | S&F Ceiling rose, 3 terminals, surface bakelite, /PVC/ Polycarbonate,complete all as specified and directed. |
| 63 | M&L for providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through concealed type rigid non-metallic PVC conduit including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Three runs of single core 6.00 Sqmm multi stranded copper cableand one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the PVC conduit. |
| 64 | S&F LED tube light fitting 4 ft. 1 x 18/20 watt with 230 volts, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 65 | S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincl mounting bracket of suitable size and connection complete all as specified and directed. |
| 66 | S&F Exhaust fans made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 250mm and connecting up includingprovision of cable 3 core ofof suitable size from ceiling rose to fan complete all as specified and as directed. |
| 67 | S&F sheet metal enclousure MCCB DB TPN vertical type, double doorAC 415 V 4 way with 200 Amps rated bus bar , includingMCCB 100 Amps 4 pole, 35KA as incomer,flush to wall including taking down old one complete and making good of distructed surface all as specifed and directed. |
| 68 | S&F single pole and neutral DB wall mounting type, 240 Volts,8 Way with 200 Amps rated bus bar, double door suitable for fixing MCB\"s including connecting etc and taking down un serviceable DB ,main switch complete all as specified and directed. |
| 69 | S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 70 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |
| 71 | Taking down existing ceiling fan from bldg and keep aside the serviceable ceiling fan for reuse and uncerviceable ceiling fan deposited to MES store complete all as specified and directed by engr-in- charge |
| 72 | S&F Ceiling fans complete with blades, down rods , and accessories, 230 V, 1200 mm sweep. Min air delivery 210CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including down rod of suitable size Bar andall fixing arrangements . complete all as specified and directed. |
| 73 | Refixing of serviceable celing fan in bldg complete all as specified and directed by engr-in- charge. |
| 74 | Supply & Fix fan hook made of 10mm dia TMT Bar for for hanging the ceilingfan complete all as specified and directed by engr-in- charge. |
| 75 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundations,manholes,laying cables,pipe lines,etc and getting out in soft/ loose soil complete all as specified and directed. |
| 76 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm of soft loose soil,complete all as specified and directed. |
| 77 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 78 | Supply and spread river sand in trenches as cable cushioning 8 cm below the cables and 15 cm above the cable all as specified and directed. Note: Punned thickness shall be measured for payment purpose. |
| 79 | Supply and lay burnt bricks sub class \"B\" standard size laid across the cable in trenches as protection to the cable complete all as specified and directed. |
| 80 | Supply and laying GI pipe, 40 mm bore (light grade) in trenches/under floors or roads or along the pole incl clamp with suitable nuts & bolts for protection of cables including taking down old unsv GI pipe,complete all as specified and directed. |
| 81 | Supply,laying and testing ofLT XLPE cable, insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with glanded aluminium conductor of cross sectional area 16 sqmm 4 core laying or passingthrough pipe/wall/floor/trenches including taking down old unsv cable complete all as specified and directed. |
| 82 | M&L Boring of holes by using trenchlkess technology under road, pavement, hard standing by for passing the cable throgh GI pipe complete all as specified and directed by Engr -in-Charge. |
| 83 | M&L Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe (light grade) for earth lead protection pipe for suitable length and GI pipe 20 mm dia (light grade) for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1(using 20 mm graded stone aggregate)for earth pit and 40 mm thick pre-cast RCC coverby using (1 : 2 : 4) type B1(using 20 mm graded stone aggregate) with 3 Nos 8 mm dia TMT bars both ways and testing on completion,completeall as specified and directed by Engineer-in-Charge. |