Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-08-2023 | Corrigendum | Other | 30-08-2023 |
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. Rate to include backfilling, leveling, dressing of sides and ramming of bottom with all leads, lifts complete as directed by the departmental officers.Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimatesFor 0 to 2m depth. |
| 2 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. Rate to include backfilling, leveling, dressing of sides and ramming of bottom with all leads, lifts complete as directed by the departmental officers.Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimatesFor 2 to 3m depth. |
| 3 | Supplying and filling in foundation, basement, etc with following Manufactured sand brought from outside filling materials in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 5 | Supplying and filling in foundation, basement, etc with following Good Earth brought from outside materials in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 6 | Providing Pre - construction Anti - termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentration under grade slab and grade beam and below the ground level as well as outside all-round the building at plinth level etc as per the instructions of manufacturer and as directed by theClient / departmental officers. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 or equivalent BS specification.The chemical to be used as insecticide for the treatment shall be Biflex Tc and the application shall be diluted 1 part of chemical Biflex Tc with 49 parts of water to get 0.05% emulsion and strictly in accordance with the manufacturer’s specification. The work should be carried out by an approved and registered specialist pest control agency only. Tenderer to furnish the name of the proposed specialist firm. A 10 years post application guarantee against defects shall be furnished by the main Contractor. Note : Horizontal plan area at ground floor level of the building will be measured and paid. The chemical to be used for the treatment and concentration of the chemical solutions should be as laid down in IS - 6313 Part II.as complete with all respects complying with relevant standard specification, as directed by the Client / departmental officers. |
| 7 | Cement Concrete 1:5:10 (One Cement, Five Manufactured sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification |
| 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 9 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)Cost of MS sheet and angles for each set weight of MS sheet BG 10 of size 90cm x 60cm x 3.175mm3.175 x 7850/1000 = 24.92 Kg24.92 Kg x 0.54 Sq.Mt = 13.46 KgWeight of MS angle of size 25mm x 25cm x 3mm3.6 x 1.1Kg/Mt = 4.00 Kg. |
| 10 | Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members |
| 11 | For plane surfaces such as rectangular, square columns and chamfered sunshades, top and bottom slab of boxing, kitchen platform, loft and such other structural members |
| 12 | Vertical surfaces - For all type of walls (any thickness) including, retaining wall, core walls, shear wall, parapet wall, fins, facia, kerb and median etc... for all floors & levels. |
| 13 | Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.0 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. |
| 14 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 15 | Foundation and Basement |
| 16 | Ground Floor Super Structure |
| 17 | First Floor Super Structure |
| 18 | Second Floor Super Structure |
| 19 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two Manufactured sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. 100mm thick, 450mm wide Precast slab |
| 20 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 21 | Brick work in following Cement Mortar using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9\" x 4-3/8\" x 2-3/4\" in Cement Mortar 1:3 (One Cement and Three Manufactured Sand) for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction. |
| 22 | For foundation & basement |
| 23 | Ground Floor Super Structure |
| 24 | First Floor Super Structure |
| 25 | SecondFloorSuper Structure |
| 26 | Brick partition walls of 11.50cm thickness using best quality II Class Ground Moulded Chamber Burnt Bricks of size 9\" x 4-3/8\" x 2-3/4\" in Cement Mortar 1:3 (One Cement and Three Manufactured Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 27 | Ground Floor Super Structure |
| 28 | First Floor Super Structure |
| 29 | SecondFloor Super Structure |
| 30 | Supplying and fixing Teak Wood Frames for Doors, Windows, Ventilators and other similarjoinery works with the following sizes and sectionsincluding labour charges for wrought and put up in position and also for fixing hold fast in frames andmasonry etc complete in all floors.Teak Wood Scantling upto 2m length |
| 31 | Supplying and fixing Teak Wood Frames for Doors, Windows, Ventilators and other similarjoinery works with the following sizes and sectionsincluding labour charges for wrought and put up in position and also for fixing hold fast in frames andmasonry etc complete in all floors.Teak Wood Scantling over 2.0m and below 3.0m in Length |
| 32 | Providing and fixing Single Leaf Solid core flush shutters with Teak ply on both side with teak wood lipping alround 35 mm thick. The shutter shall be made of solid core of block board type bonded with PF synthetic resin conforming to BWP grade of IS 848 with 6mm thick teak wood lippingas per drawing. The construction procedure of the shutter should be as per IS 2202. The shutter shall be shop prepared for taking mortice lock or latches suitable lock block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock, covered in IS 2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. The both side door shall be finished with 1mm thick laminate of approved color and pattern. Rate shall include for cost of hardwares (aluminium hinges 125x30mm size - 4 / 3Nos. aluminium aldrop of size - 250x16 mm - 1No. Aluminium tower bolt of size 250x12mm - 1Nos. tower bolt of size 200x12mm - 1No, D type aluminium handle of size 200mm-2No., aluminium door stopper with nylon bush - 1No) as required and fixing them all like lock, hinges, handle, tower bolts, and other accesories etc..as complete with all respects complying with relevant standard specification, as directed by the Departmental officers. |
| 33 | All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. The both side door shall be finished with 1mm thick laminate of approved color and pattern. Rate shall include for cost of hardwares (aluminium hinges 125x30mm size - 4 / 3Nos. aluminium aldrop of size - 250x16 mm - 1No. Aluminium tower bolt of size 250x12mm - 1Nos. tower bolt of size 200x12mm - 1No, D type aluminium handle of size 200mm-2No., aluminium door stopper with nylon bush - 1No) as required and fixing them all like lock, hinges, handle, tower bolts, and other accesories etc..as complete with all respects complying with relevant standard specification, as directed by the Departmental officers.All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. The both side door shall be finished with 1mm thick laminate of approved color and pattern. Rate shall include for cost of hardwares (aluminium hinges 125x30mm size - 8Nos. aluminium aldrop of size - 250x16 mm - 1No. Aluminium tower bolt of size 250x12mm - 2Nos. tower bolt of size 200x12mm - 2No, D type aluminium handle of size 200mm-4No., aluminium door stopper with nylon bush - 2No) as required and fixing them all like lock, hinges, handle, tower bolts, and other accesories etc..as complete with all respects complying with relevant standard specification, as directed by the Departmental officers.1500 x 2400mm |
| 34 | Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish ofDouble leaf fully glazed Door shutters with 5.50mm thick glass. The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section with Vertical & Top rail: 50x44.45x2.50mm @1.292 kg/m, Bottom rail: 100x44.45x2.50mm @ 1.974 kg/m, Lockrail : 50x44.45x2.5mm @ 1.292 kg/mAlu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/mAlu. Handle: 100x30mm @ 0.988 kg/mand necessaryaccessories such as Alu. clips rubber beading, full length of handles on both sides, lock, furniture fittings such as, Hinges, Automatic door closer, rubber bush, stopper including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the reuired extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc. complete. All the Alu. Section are to be anodised with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete |
| 35 | Supplying , fabricating and fixing in position Aluminium Anodised natural colour mat finish Two track sliding window in all floors with Aluminium sections of outer Frame bottom 62x37mmx1.50mm at 1.218 kg/m,the Side & Top 62x31.50x1.50mm at 0.778 kg/m,ShutterTop 40x18x1.5 at 0.38 kg/m,Bottom 40x18x1.5 at 0.38kg/m, Side Vertical 40x18x1.50mm at 0.493 kg/m, Vertical locking section 40x29x1.5mm at 0.632 kg/m, with necessary accessories such as rubber beadings, special hinges, lock, handle including supplying and fixing 4mm thick plain glass including cost of all materials , labours, power consumption required for fabrication , drilling holes in RCC colunm, slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing and also as directed.The aluminium sections are to be anodised with matt finish under electrically controlled in accordance with IS 1868 / 1962 for an average anodic film thickness 15 microns etc., complete. |
| 36 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. |
| 37 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work. |
| 38 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 39 | Wall HandrailManufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 40 | Providingandfixing welded M.S. grills for the window openings and any openings as per drawing with necessary screws, bolts andfixed withnecessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the departmental officers. |
| 41 | Paving the floor / skirting with best quality Double charged vitrified tiles of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three Manufactured sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)Size of tiles shall be 800 X 800 X 10 mm Double charged vitrified tiles- Polished / Matt |
| 42 | Paving the wash basin counter with best approved quality fine polished Antiskid Vitrified tiles of 600x600x8mm thick laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three Manufactured sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments, nosing etc., The marble slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 43 | Providing and fixing approved colour Marble Jambs of approved shade and to a thickness not less than 18mm, to a maximum width of 300 mm along the jambs of the doors with cement mortar 1:3 to specific shape, size and profile as shown in the drawing. Rate shall be inclusive of cutting, chamfering, granite edge polishing and Granite joint finish with approved grout.,complete at all levels and heights and as directed by Engineer-in-Charge. The marble slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 44 | Paving the floor / skirting / steps with best approved quality gradeSlab 18mm to 20mm thick and above free from all defects in all floors over a base layer of CM 1:3, 20mm thick. The marble slab shall be laid over the cement mortar by applying white cement slurry in between base mortar and marble slab and pointed with white cement neatly including polishing with polishing stone and oxalic acid etc. so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges, etc. The marble slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete. Size of marble and pattern as shown in the Architectural Drawing |
| 45 | Paving the floor with fine polishedskirting / steps withfine polishedkota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (one cement three Manufactured sand), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 46 | Paving the floor with Cement Based Hydraulically Pressed Anti skid Tiles (Pattern design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 47 | Supplying and fixing fine polished cuddapah slab for cup-board, wardrobe, shelves, kitchen sinks and sunshade etc, for the following thickness including cost of Cudappah Slab, labour and laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.- 20 / 30mm thick |
| 48 | Dadooing walls with following best approved quality, Vitrified tile set in Cement Mortar 1:3 (One Cement and Three plastering sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. Size of tiles, colour and pattern as shown in the Architectural Drawing |
| 49 | Dadooing walls with following best approved quality, approved colourGranite Tilesof 8mmthickness not less than 8mm of size 1200x600 mm, set in Cement Mortar 1:3 (One Cement and Three plastering sand) 20mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 50 | Supplying and fixing Fine polished Granite Slabs of18 / 20 mm thick1200 x 600 mm to shape finished with polished on both sides, slab table rubbed, edges rounded including necessary SS 316 clamps cutting, edge nosing and polishing etc., for urinal partition and any other partitions. Rate including all materials, labour charges, preparation of surface, necessary cutting in wall surface, consumables etc as complete with all respects complying with relevant standard specification and as directed by the departmental officers. |
| 51 | Plastering with Cement Mortar 1:5 (One cement and Five plastering sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 52 | Ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 53 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 54 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 55 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification. |
| 56 | Providing and applying Texture paint finish for exterior / interior surface as per Manufacturers specification and as directed. Application of primer by diluting thetexture compound by mineral on the plastered surface and apply final two coats of exterior / interior emulsion on the primer. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages, cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the departmental officers. |
| 57 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 58 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 59 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades, Structural steel members etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)Supply and laying of respective water proofing treatment at below mentioned locations including all below activities.The surface to be waterproofed shall be cleaned to ensure it is free of laitance, loose particles, oily substance which may affect the adhesion of the waterproofing system, using mechanical rotary wire brush and related tools etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, staging, tools and plants, fuel, curing,cleaning, testing, consumables and also include for conducting leakage test at toilet sunken portion and over head tanks by storing water on the sunken continuously for a period of 7 days etc. as complete with all respects complying with relevant standard specification and as directed by the departmental officers. |
| 60 | Supply and laying water proofing treatment on top of PCC laid for Grade slab, Raft, Pile cap ,footing& beam, STP, ETP, UG Sump , Water tank etc., in the following order andconsisting of following operations. i) Supply and applyingof one coat of TAPECRETE Acrylic Polymer Cementitious Coating over rendered PCC surface. Application of CORCHEM 206 – I High Build Polyurethane Based Elastomeric Coating to the thickness of 1.5 mm in two coats over TAPECRETE applied surface.ii)Supply and Fixing 75 mm long 18 mm dia GI nozzles in the hole of about half the depth of member size in grid pattern at a spacing not more than 1.0 meter c/c while casting the raft slab and alongconstruction joints at a spacing not more than 1.0 meter c/c along the construction joints. iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement.iv) Sealing & cutting of the nozzles, and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight. |
| 61 | Supply and applying water proofing treatment on Retaining walls external surface at Lift wall, UG Sump, STP, ETP, Water tank, Raft sides etc. using cement admixed withwater proofing compound in the following order.i) Making \" V \" grooves at the construction joints of size20 x 20 mm and filling the \"V\" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cementii) Supply and Fixing of 50 long 18 mm dia GI nozzles in the hole of about half the depth of member size alongconstruction joints, and honey comb areas at a spacing not more than 1m c/c.iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement.iv) Sealing & cutting of nozzles and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight. v)Supply and applying one coat of TAPECRETE Acrylic Polymer Modified Cementitious Slurry Coat overwell prepared surface as a Primer and applying CICO CORCHEM 206 - I Polyurethane Based Elastomeric Coating to the thickness of 1.5 mm in 2 coats over TAPECRETE slurry coat applied surface.vi) Lay protective plaster layer with 12mm thick Cement Mortar 1:4 (1 cement: 4 coarse sand)admixed with Normal setting integral Waterproofing compound CICO NO.1 or approved equivalent conforming to IS 2645 at the rate of2% by weight of cement over the third coat of brush topping. Plaster shall be cured byspraying of water for the next 7days. The entire water proofing system shall be protected with a 25 mm thick extruded polystrene with necessary low VOC adhesieve. |
| 62 | Supply and laying water proofing treatment Internal surface of Lift, Retaining wall etc., in the following order andconsisting of following operations. i) Making \" V \" grooves at the construction joints of size20 x 20 mm and clean the surface with wire brush, and filling the \"V\" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cementii) Supply and Fixing 18 mm dia GI nozzles(the hole shall beabout half the depth of the member to be grouted and nozzle should be 50mm)the retaining wall, alongconstruction joints, and honey comb areas at a spacing not more than 1m c/c . Nozzles (can also) shall be post fixed by drilling holes usingdrill machine and to be fixed with cement putty admixed with quick setting integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight .iii) Supply and Applying injection grouting through the nozzles by hand operated grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement .Grouting operations to be taken up after the concrete reached the full strength, i.e 28 days after casting of concrete.iv) Sealing off the nozzles after grouting operation is over with cement putty admixed with quick setting integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.v) Cut the projected nozzles if required over the concrete surface and fill withcement putty admixed with quick setting integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1 by weight. |
| 63 | Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. |
| 64 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 65 | Finishing the top of roof with one course of Solar Reflective tiles of size 305mm x 305mm x 7mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Manufactured Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 66 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 67 | Designing, Providing and fixing in position Hot rolled structural steel Members / Sections consists of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, flats, gate for compound wall etc. at all levels.Rate to including all materials, labour charges, scaffolding, stagging,transportation, lead & Lifts, wastage, cost of bolts, nuts, washers, welding, electrodes and connections required for the work etc., as complete with all respects complying with relevant standard specification, as directed by the departmental officers. |
| 68 | Supply and Fixing by drilling holes for roofing with Prepainted Galvalume sheet 0.47mm thick of best approved quality with required size with curve shape and white ridge sheet with necessary bolts and nuts, bitumen washers including cutting the sheet to the required size found necessary during execution etc., complete complying with standard specification includingInsulation shall be ROCKINSUL Building Rolls of 50mm thick, 48Kg/m3 density in roll forms or as per design requirement composed of basalt Rock fibre bonded together by thermosetting resin with ALG factory laminated facing. The Insulation shall be noncombustible as per EN 13501-1 & BS 476 part 1. The K value - 0.034 W/mK, R value -1.47 m2K/W,U value -0.61W/m2K.The insulation shall be supplied in the form of rolls. The Insulation shall besupported over 50 x 50 mm x 1.6 mm galvanised welded wire mesh. Insulation shall be supported by using 10 G, GI wires tied diagonally with the purlin to avoid sag. |
| 69 | Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer |
| 70 | Semi unitized glazing system with Vision, Vision on Spandrel panel & Spandrel panel / Top hung Openable Panel with the specified DGU Glass - 24 mm thick as described below : Designing, providing and fixing Semi Unitized structural glazing with vision panel & vision on spandrel panel structurally held in position by Structural sealant and factory fabricated, erected the system to any shape,profile and at levels etc complete with Aluminium adaptor of suitable size and profile in order to satisfy the structural design criteria specified in the Technical specification.In general, the system comprising Aluminium PVDF finished (coating thickness not less than 35 microns) extruded frames confirming to IS 8147 and PVDF confirming to ASTM, Sub frame with Integral edge guard (child frame), shutter frame with Integral edge guard, toggle cleats, adapters, main frame supported on the Hot Dip Galvanised (HDG) brackets (spanning of frames not exceeding 3.6 M C/C) with suitable SS anchorsand bolts, flashings (inside & outside), Smoke Seals, as required, \"C\" shape Aluminium clamps of suitable size to connect the transom on to Mullion with SS Screws etc. complete in all respects.The size of main glazing frame work of both Mullion and Transom shall not be less than 170*70 mm to profile and shape with wall thickness not less than 2.5 mm with Sub frame (Child frame) / Shutter frame suitably to receive the glass as given below. The size of sub frame (child frame) shall not be less than 60*25 mm - 2.5 mm thick to shape & profile and to accomodate 3 stage EPDM barrier and fixing the panels with Toggle cleats of size 50*25 mm - not less than 4 mm thickness and at specing not more than 400 mm with SS 316 Grade anti-slip screws of suitable size and depth.Shutter frame size shall not be less than 75*40 mm - 2.5 mm thickness to profile matching with Main frame (Mullion and Transom connected with suitable size aluminium clamp and thickness not less than 3 mm. Weather silicon of Clear Transperant colour shall be applied between the connections of all members and between associated accessories. Bracket (HDG/Aluminium) with serrations as required shall be provided and the size shall not be less than 125 *125 - 100 mm wide - 10 mm thick. Anchors shall be HSA - 3 R /R as appropriate of Hilti or approved Equivalant make and all bolts, serrated washers and nuts shall be SS 316 Grade of approved make.The system shall have 3 barrier. ie 1st barrier shall be Polymaid, other 2nd, 3rd level barriers with EPDM and Non statining weather silicon DC 991 HP of approved colour between the Aluminium edge guard (Integral part of sub frame / shutter frame) on the exposed groove. No anchors/Screws/fasteners are allowed on the Masonry wall and Bi-Mettalic barriers shall be provided between 2 different metals are in contact. No Half mullion and Transom is allowed on the system and end cap shall be provided of size not be less than 60*28 mm - 2.5 mm thick to profile to cover the gap between Glazing frame and adjoining structure.The system shall be fixed with Double glazed Unit (DGU) of 24 mm thick having 6 mm thick Reflective coated low E glass on # 2 surface with SKN 744 of Saint Gobain make or Blue Pearl of Asahi make or DS 40 - Blue of Guardian make or approved equivalent make as outer pane and 12 mm airgap with Black spacer and 6 mm thick glass uncoated clear as inner pane of same make and both panes are heat treated / heat strengthened.Note: Size, thickness, profile, shape of all members, frames and accessories etc are given above are tentative, indicative and as minimum. It is the responsibility of the Facade approved Specilized vendor to check the above profile, size and thickness to satisfy the specified wind load with Corner effect, Service loads and provide the sections, brackets and anchors suitably but not less than the specified section and profile details above.Rate shall exclude the cost of top hung window hardwares with shutter frame, which will be measured and paid separately under the respective item below. Rate shall include the cost of supplying & fixing of glass, fixing of Top hung window hardwares with Shutter, Flashing around the Glazing, Floor and soffit level smoke seal with GI cover and Compressed Rock wool Insulation, visual mock up and field water test etc. System to be designed to with stand design wind pressure of 200 Kg/Sqm plus Corner Effect 15% of wind load, total pressure shall be 230 Kg/Sqm confirming to IS 875 part 3 and other load, Service load parameters shall be as relavent specification. |
| 71 | Supplying & fixing in position Modular toilet cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch impact and anti bacterial resistant 12mm thick solid compact laminate panels tested in lab. Colour of HPL Boards should be as per approved colour from approved make Cubicle Shade Card. The product should comply with IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. This also includes providing and fixing in position necessary hardware made out of Aluminium, Nylon as per manufacturer’s specifications & Architects instructions like (1) Nylon Adjustable foot, (2) Aluminium U Channel, (3) Nylon Gravity hinges, (4)Nylon Coat hooks, (5) Nylon Door Knob, (6) Nylon Thumb Turm Indicator (7) Aluminium Door Stopper Channel, (8) Aluminium Top Rail(9) Wall Plugs & Noise Tape.All screws should be 304 Grade stainless steel with satin finish. The partitions should be anchored into the wall with either anodised or powder coated Aluminium channels. All pilasters should be supported by height adjustable legs.Intermediate panels should withstand to fix paper holders and toilet seat cover dispensers. Vendor has to submit a shop drawing for Architect\"s approval. The system must have comprehensive warranty of 10 Years for Compact laminate and 2 years for Hardware. Quoted rate should be inclusive of all the works mentioned above for complete installation.Working at all levels and heights and as directed by Engineer- in- Charge.Overall Height Of Cubicle should not be less than 1995 mm from FFL (Including bottom Gap of 150mm)Note: 1.Quoted rate to include deviations in the below mentioned length or breadth to a limit of +/- 50mm due to site conditions.2. All EWCs will have concealed cistern and ledge wall projection of minimum 100mm depth. Quoted rate to include closing the gap above ledge wall with extended Intermediate partitions. |
| 72 | Toilet Cubicle with standard dimension of 1995mm Height x 900mm Width (which includes 600mm door size width) and 1250mm length intermediate partition. |
| 73 | Toilet Cubicle with standard dimension of 1995mm Height x 1000mm Width (which includes 600mm door size width) and 1250mm length intermediate partition. |
| 74 | Toilet Cubicle with standard dimension of 1995mm Height x 1150mm Width (which includes 600mm door size width) and 1400mm length intermediate partition. |
| 75 | Toilet Cubicle I-Shape (Front Partition) with standard dimension of 1995mm Height x 1300mm Width (which includes 600mm door size width). |
| 76 | Providing storage below counter : The storages with minimum one rows of shelves and frame with swing shutters using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and shelves and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. |
| 77 | Providing and fixing seamless ceilingas shown in the Architectural Drawing with Gypboard of 12.5 mm thick, fixed to the underside of the suspended grid formed by GI Ceiling sections, channels and GI perimeter channelusing wood screws and metal expansion rawl plugs.The GI intermediate channel shall be fixed to the suspended strap hanger / GI ceiling angle at intervals not more than 1220 mm.The suspended GI ceiling angle /. Strap hanger is to be connected with GI soffit cleat and it should be fixed on the roof slab / beam, by using metal expansion fasteners of 12.5 mm dia. to a length of 35 mm with 6 mm dia. bolt / screw at top ends. Suspension points and clips shall be able to take a minimum safe load of 50 kgs. Perimeter channel should be fixed around the walls/ partitions on which the gyp board is terminated.The GI ceiling section are to be provided across the intermediate channel at intervals not more than 457 mm centers at bottom and the same shall be fixed by GI connection clips 2.64 mm dia at the intersection points. All these suspended ceiling components should be coated with AZ150as per IS 15961 on both sides. The Gypboard shall be fixed to the under side of the suspended grid by using 25 mm long dry wall screws.The joints shall be finished with joint paper tape/ fiber mesh and jointing compound as per manufacturer\"s specification. Necessary time to be provided for joint curing and then apply 3 layers of the filler compound to provide a smooth surface. The ceiling surface shall be painted with three coats of approved first quality acrylic emulsion with low VOC over a coat of primer. The Quoted rate shall include for providing necessary offsets and grooves, curved profiles as per the drawings, making cutouts for lights, spot lights, duct doors, grills, additional trimming around cutouts for light fittings, grills and also for providing additional supports from ceiling where main / cross members are cut for light fittings for which no extra will be paid separately and working at all heights and levels and as directed by the departmental officers.Quoted rate to include all the works mentioned above. Visible surfaces both Verticals and Horizontals will be measured and paid. Detections will be made for openings more than 0.36 Sqm |
| 78 | With Plain Gypsum board with density not less than 640 kg/m3 |
| 79 | With Moisture resisting Gypsum board with density not less than 760 kg/m3 |
| 80 | Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain / perforated lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre \"T\". The \"T\" shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of \"T\" section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of \"T\" section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile \"L\" Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look |
| 81 | Providing and fixing Wooden false ceilingas shown in the Architectural Drawing using 50mmx25mm Aluminium extrusions in both ways not more than 600mm c/c with necessary supports from ceiling and all the exposed surfaces should be covered with one layer of 12mm thick BWR ply finished with 1mm thick laminate of approved shade / design. Rate inclusive ofnecessary countersunk heavy duty screws, hardware and adhesives. Teakwood or PVC edge beadings / Aluminium edge profiles to be provided at all levels and heights and as directed by the departmental officers.Basic Cost of Laminate : Rs 60/ Sft |
| 82 | Supply and Installation of False ceiling with CNC cut designer board with the materials as listed below. The designer board to be fixed with necessary aluminum supports / suspended hangers, wires etc. Area will be measured and paid. Design to be approved by Architects. Working at all levels and heights and as directed by Engineer- in- Charge. |
| 83 | With 3mm thick Aluminium sheet powder coated of approved colour over the 3mm Acrylic sheet. |
| 84 | Supply and installation of Anutone (or) Euivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fullyencapsulated ceiling tile of size 595 x 595 x 15mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specication. |
| 85 | Providing Wall Panelling using one side 19mm BWR Ply with 1mm laminate with following specification.The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 19mm thick over the aluminium frame work with necessary screws. One side 1mm thick laminate of approved shade will be fixed over the plywood and finishing colour and shade the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, laminate and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. |
| 86 | Providing column / beam / Wall Panelling using6 mm thick Acrylic solid surface with 12mm BWR Ply backing with following specification.The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretion. All the exposed surface to be covered with acrylic solid surface as shown in the drawing. The exposed edges and corners shall be chamfered to a width of 1mm to avoid sharp edges. Rate shall be inclusive of 6mm solid surface, 12mm BWR Ply, Aluminium sections, necessary accessories, sealant for joint finish, adhesives for fixing, buffing/ polishing., complete., Working at all levels and heights and as directed. The design pattern, and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.Basic Cost of Acrylic solid surface - Rs 250 /Sft |
| 87 | Supply and Installation of CNC cut designer board with the materials as listed below. The designer board to be fixed over the masonry/ RCC / Partition / wall panelling works with necessary aluminum supports / suspended hangers, wires etc. Design to be approved by Architects. Working at all levels and heights and as directed by the Departmental Officers. The design pattern and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. |
| 88 | With 25mm thick external grade MDF board. All the exposed surface shall be finished with Duco paint of approved shade. (Location : Meeting hall) |
| 89 | With 12mm thick Acrylic solid surface of approved shade.Basic Cost of Acrylic solid surface: Rs 150 / Sft(Location : Meeting hall) |
| 90 | With 3mm thick Aluminium sheet powder coated of approved colour. (Location : External Elevation wall) |
| 91 | Supply and Installation of linear wall cladding system made of Aluminium box sections with powder coated wood finish from approved makeas shown in the Architectural Drawing. The size of the panel shall be 50 X 100 mm made of 0.5mm thk Aluminium rectangle profiles. The system shall be supported by necessary runners, stiffeners and carriers as per manufacturer\"s specification.The rate quoted for wall panel system shall include scaffolding arrangement, providing necessary supports, cutouts for all fixing light fixtures (all sizes) AC diffuser, and any other openings to be made in wall panel as directed. |
| 92 | Providing and fixing Acoustic Wall Panelling (equivalent to Armstrong) in channelled wood works perforated panels of width 192mm, thickness of 15mm and length of 2400mm or as per required by the Departmental Engineer made of a high density fibre board with minimum 725 kg./m3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special peforation pattern where the visible surface has a \"Helmholtz\" fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be \"tongue-and-grooved\" to receive special clips for installation. The back of the perforated panel shall have sound absorbing non woven acoustical fleese having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Engineer-in-Charge.Installation: Install aluminium box section (provided by others) of section 50mm x 25mm or as approved by the Engineer-in-Charge on the solid wall horizontally using screws and plugs at spacing of 600mm centre to centre. Screw the aluminium extruded keel for channelled wood works provided by Armstrong over the lowest and second aluminium section at an on centre distance of 600mm. Place the inside clip on the groove end of the panel along the aluminium keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour (provided by others). Installation to be carried out by Armstrong Trained Installation Team and installation should be carried out as per Armstrong Recommended Procedure. |
| 93 | Dismantling existing Brick work / solid block workincludingcement plastering, pointing, stacking the serviceable materials and disposing the unserviceable materials / debris and carting within the site etc., complete as directed. |
| 94 | Above Basement upto 3m height |
| 95 | Above 3 m Height |
| 96 | Demolishing Reinforced cement concrete using deploying machineries, including disposal of material / debris and carting within the site etc. Rate shall include for cutting of reinforcement steel of any size and shape with necessary tools and plants, scaffolding, water and power charges, cleaning the surface etc., complete and as directed. The rate shall include for stacking neatly and handing over the reinforcement steel removed from the dismantled concrete. |
| 97 | Dismantling of existing flooring / skirting / dadoing with Mossaic tiles / Glazed tiles / Cuddapah slab / Granite including base mortar, stacking of serviceable material and disposing the unserviceable materials / debris and carting within the site etc., complete and as directed. |
| 98 | Dismantling of existing brick tile / pressed tile and weathering coarse of any thickness in terrace floor including base mortar, stacking of serviceable material and disposing the unserviceable materials / debris and carting within the site etc., complete as directed. |
| 99 | Removing of existing fire / flush / glass door / Rolling Shutter / Windows / Ventilators with frames from the wall / column / partition including hinges, holdfast, fastenings, clamps etc., without making any damages to the doors and stacking of them / handing over to the client in all respects, disposing the unserviceable material, carting within the site etc., complete as directed. |
| 100 | Disposal of building rubbish / unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground or as approved by departmental officers, beyond the initial lead, for all leads including all lifts involved.(Lead upto 2Km considered) |
| 101 | Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. The External Water Supply Arrangements (Above Ground Level) |
| 102 | 15mm dia Cpvc |
| 103 | 20mm dia cPVC |
| 104 | Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. The External Water Supply Arrangements (Above ground level ) |
| 105 | 15mm dia UPVC |
| 106 | 20mm dia UPVC |
| 107 | 25mmdia UPVC |
| 108 | 32mm dia UPVC |
| 109 | 40mm dia UPVC |
| 110 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..... such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to thePVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) |
| 111 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm ( without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 112 | Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) |
| 113 | Supplying and fixing in position best quality S S 304 sink of of 600 x 450 x 200mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets.[The sink and specials should be got approved by the Executive Engineer before use on works] |
| 114 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 6mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 115 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 116 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 117 | Supplying and fixing position PVC Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to thePVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 118 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 119 | 75mm dia PVC |
| 120 | 110mm dia PVC |
| 121 | Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements. Since the labour for cutting, threading / pasting, sundries have already been included under pipe line item of works, no separate provision for fixing UPVC specials needs to be allowed |
| 122 | 20mm dia UPVC Elbow |
| 123 | 25mm dia UPVC Elbow |
| 124 | 32mm dia UPVC Elbow |
| 125 | 40mm dia UPVC Elbow |
| 126 | 25mm x 20mm CPVC Elbow |
| 127 | 20mm x 15mm CPVC Brass Elbow |
| 128 | 25mm dia UPVC Tee |
| 129 | 32mm dia UPVC Tee |
| 130 | 40mm dia UPVC Tee |
| 131 | 32mm to 25mm UPVC Tee |
| 132 | 25mm to 20mm UPVC Tee |
| 133 | 20mm x 15mm UPVC Brass Tee |
| 134 | 20mm dia UPVC Union |
| 135 | 25mm dia UPVC Union |
| 136 | 32mm dia UPVC Union |
| 137 | Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9\" x 43/8\" x 23/4\" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 7.5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. |
| 138 | 600mmx 600mm |
| 139 | 450mm x 450mm |
| 140 | 900mmx 900mm |
| 141 | Supplying, laying and jointing glazed stoneware pipes of 150mmdia of approved best quality with spigot and socket ends (in reverse direction) in dry condition and laid in loose joints (i.e.) without cement and spun yarn, so that the waste water can be drained to the trenches already available, excluding cost of earth work excavation, cost of re-filling with crushed stone sand/ earth, but including laying the pipe in true alignment and gradient and conducting required water supply test for draining with necessary tools and plants, etc., complete complying with standard specifications. |
| 142 | Supplying, laying and jointing glazed stoneware pipes of 250mmdia of approved best quality with spigot and socket ends (in reverse direction) in dry condition and laid in loose joints (i.e.) without cement and spun yarn, so that the waste water can be drained to the trenches already available, excluding cost of earth work excavation, cost of re-filling with crushed stone sand/ earth, but including laying the pipe in true alignment and gradient and conducting required water supply test for draining with necessary tools and plants, etc., complete complying with standard specifications. |
| 143 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 144 | For SD tap 15mm dia |
| 145 | Pillar tap 15mm dia |
| 146 | Swaneck tap 15mm dia |
| 147 | angle valve 15mm dia |
| 148 | Supplying and fixing in position first quality and approved variety of brass metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 149 | 20mm dia |
| 150 | 25mm dia |
| 151 | 32mm dia |
| 152 | 40mm dia |
| 153 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 154 | Supplying and fixingCP Shower Arm with Overhead Shower Rose ofsize 15mm dia with approved make and quality. |
| 155 | Supplying and fixing CP Wall Mixture Tap 3 in 1 system with Hand Showers of approved make and quality. |
| 156 | Constructing brick masonry water tight Grease Trap (with three chambers , each of 0.4 M X 0.6 M in plan) with 75 class designation bricks in cement mortar 1 : 5 ( 1 cement : 5 fine sand ) earth work, excavation in all kinds of soil, foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including constructing baffle wall, stainless steel angles on corners, stainless steel perforated plates with stainless steel lifting handles in each chamber,inlet and outlet fittings in Cast Iron, double seal C.I. covers complete as per standard design:Inside size 2.0m x 1.5m and 1.0m deep including two nos. 60x60 cm. C.I. Cover and frame (double seal weight of cover and frame not less than 75 kg) |
| 157 | Supply, Receiving, Storing&Fixing of CP brass wall mounted sink mixer with C.P. wall flange, swinging spout complete as required with flow rate of 6.0 LPM complying to Green Building requirements. (FOR sink only having hot water (kitchen sink and pantry)) |
| 158 | Providing and fixing 8 mm dia C.P. S.S. Health Faucet with flexible tube upto 1.5 metre long and make as approved by Engineer - in - charge (with every water closet) |
| 159 | Providing and fixing CP Brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge. (with every wash basin and urinal) |
| 160 | Providing and fixing CP Brass 40mm size bottle trap of approved quality & make and as per the direction of engineer in charge. (with everysink) |
| 161 | Providing and fixing cp brass toilet paper holder |
| 162 | Supply, Receiving, Storing&Fixing ofC.P. brass twin coat hook with PVC rawl plug & C.P. brass screw complete as required. |
| 163 | Providing and fixing uplasticised PVC connection pipe with brass unions 45cm length.( 15mm nominal bore) for every angle valve to coonect it with fixture |
| 164 | Providing and fixing white finishes ABS Hand Dryer (for all big toilet) |
| 165 | Providing and fixing cp brass liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. For every toilet |
| 166 | Providing and Fixings Curved shaped urinal partition with frosted glass Glass: 8mm / 10mm, Finish: Chrome, (partetion between urinal) |
| 167 | fixing of Chromium Plated Towel ring Circular/Rectangular shapewith concealed fittings arrangement ofapproved quality and colour, of approved brand & manufacture complete as per direction of Engineer in Charge. (for every hand wash area) (2 nos for first fllor and 3 nos for ground floor |
| 168 | Providing & fixing of Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 Floor Cleanout,(FCO & COP) round or square with rubber seal and flat round cover with screws and other required fitting complete as required. |
| 169 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 170 | Supplying, loading & unloading assembling at site, installation, fixing on the position, testing & commissioning of 15 HP Star Delta Starter. cubical type, dead front, 1.6mm thick sheet steel enclosed, wall mounted indoor use Starter Panel etc. with vermin proof hinged lockable doors compartment provide interconnections, earthing stud and powder coated. Each Starter feeder panel shall have 63A, TP MCB with central overload trip mechanism and flag indication of 10 kA breaking capacity, along with TP contactors, overload relay and SPP as per Type-IIco-ordination with necessarypotantial free auxiliary contact to oprate starter ON/OFF on fire signal and for remote switch, Start/Stop Push buttons, Auto/Manual/off selector switch Complete as required, |
| 171 | Supply, laying, testing & commissioning of the following size cables in suitable HDPE pipes in a trench to be excavated at a depth of 0.75 metre and refiling the earth to make good |
| 172 | 3.5C x 300 Sqmm Al. Arm Cable |
| 173 | Supplying, Laying, testing & commissioning of the following sizes ofPower Cables, Solid Aluminum/copperconductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape / Extruded Inner sheathed , Un. Armour or Armour (Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanized wire for cables up to 2x10 sqmm, 3x10 sqmm, 4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, FRLS insulation at outer sheath, 1100V grade as per IS 7098(Part 1) 1988 |
| 174 | 3.5C x 185 Sqmm Al. Arm Cable |
| 175 | 3.5C x 70 Sqmm Al. Arm Cable |
| 176 | 4C x 16 Sq. mm Al. Arm cable |
| 177 | 4C x 6 Sq. mm Cu. Arm cable |
| 178 | 4C x 4 Sq. mm Cu. Arm cable |
| 179 | 3C x 4 Sq. mm Cu. Arm cable |
| 180 | 3C x 2.5 Sq. mm Cu. Arm cable |
| 181 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 182 | 3.5C x 300 Sqmm Al. Arm Cable |
| 183 | 3.5C x 185 Sqmm Al. Arm Cable |
| 184 | 3.5C x 70 Sqmm Al. Arm Cable |
| 185 | 4C x 16 Sq. mm Al. Arm cable |
| 186 | 4C x 6 Sq. mm Cu. Arm cable |
| 187 | 4C x 4 Sq. mm Cu. Arm cable |
| 188 | 3C x 4 Sq. mm Cu. Arm cable |
| 189 | 3C x 2.5 Sq. mm Cu. Arm cable |
| 190 | Supply, laying & testing of following size circuit/submain/control wiring along with earth wire including making both end terminations with copper lugs, the following sizes of FRLS Type-D PVC insulated (RoHS compliance) class 2 copper conductor, single core cable confirming to IS:694 in surface/recessed existing ISI Mark Rigid M.S. conduit as on date as required. |
| 191 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 192 | 4 X 10 sq. mm + 2 X 4 sq. mm earth wire |
| 193 | 2 X 4 sq. mm + 2 X 2.5 sq. mm earth wire |
| 194 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 195 | Supplying and fixing of following sizes of minimum 2.0/1.6 mm thick ISI Mark Rigid M.S. conduit as per IS:9537 Part-3 latest as on date along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 196 | 20 mm internal dia 1.6 mm thick |
| 197 | 25 mm internal dia 1.6 mm thick |
| 198 | 32 mm internal dia 1.6 mm thick |
| 199 | Supplying and fixing of following sizes of Corrugated pattern (min 120gsm) Galvenized Steel (min Z120GSM) Flexible Conduit as per IS:3480 & BS:731-1 latest as on date, helical wound single lock, LFHSUV resistance against corrosion, certain water tightness, Coupler for tight spot installation at both ends. Temperature Range - 25 deg \"C\" to +90 deg \"C\" and IP rating: 40, complete with all required accessories in such a way wires should not be viewed and proper clamp on surface at max distance of 300mm completed as required. |
| 200 | 20mm size having ID:17mm, OD:20mm sheet thickness min. 0.25mm |
| 201 | 25mm size having ID:21mm, OD:24mm sheet thickness min. 0.25mm |
| 202 | Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:43) horizontal type Distribution boards Three pole and Neutral conforming to IS: 8623-1 & 3, made out of pre-treated and powder coated (minimum 60-80 micron), minimum 1.2mm thick sheet steel double door enclosure (IK 09), 500 V, mount on surface / recess, complete with minimum 3 x 63A tinned copper insulated prong type short links with end cap , common neutral bus bar, common earth bar, din bar, interconnections including earthing stud etc. as required. The cost shall include required minimum 10sqmm copper insulated interconnection wire set, blanking Plates, sticking saddles, cement spill protector, cable ties, circuit identification labels & laminated DB Detail chart as standard or as suggested by Architect/Consultant. (As described below) |
| 203 | 6 WAYTPN DB (PDB)Incomer 63A 4P MCB- 1 No Outgoing 6A to 32A SP MCB - 18Nos |
| 204 | 8 WAYTPN DBIncomer 63A 4P MCB - 1 NoOutgoing 6A to 32A SP MCB - 24 Nos |
| 205 | Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:43) Distribution boards Single pole and Neutral conforming to IS: 8623-1 & 3, made out of pre-treated and powder coated (minimum 60-80 micron), minimum 1.2mm thick sheet steel double door enclosure (IK 09), 240 V, mount on surface / recess, complete with minimum 63A tinned copper insulated prong type short links with end cap, neutral bus bar, earth bar, din bar, interconnections including earthing stud etc. as required. The cost shall include required copper insulated wire set, blanking Plates, sticking saddles, cement spill protector, cable ties, circuit identification labels & laminated DB Detail chart as standard or as suggested by Architect/Consultant.(As described below) |
| 206 | 12 WAY SPNLDBIncomer32A DP MCB - 1 NoOutgoing6A to 32A SP MCB - 10 Nos |
| 207 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 208 | Earthing as per PWD standard with an earth electrode of 2 metre Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work |
| 209 | 25mm x6 mm G.I. Strip forPanel on surface/ existing tray, tapped from nearest earth strip. |
| 210 | Supplying and laying6SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. |
| 211 | Supply, laying, connection, testing and commissioning of following sizes of 1.1kV gradeSingle core FR PVC insulated Single core unsheathed Industrial Flexible Cable confirming to IS:694/1990 and IS: 732 for installation with Flexible Bright annealed copper conductor for 1.1kV voltage grade. It should include both ends terminal joints providing tinned copper terminal lugs, single compression PVC cable glands up to 16 sqmm cable and double compression PVC cable glands for above, insulation tape, effecting terminal connections to the equipment complete as required. |
| 212 | 6.0 sq.mm. Cu. Flexible cable |
| 213 | Wiring for SWITCH Controlled light & Fan point with 1.5Sqm FRLS PVC insulated multistrandeded copper conductor 1100 Volt grade wires in MS surface/concealed conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted modulr switch with moulded cover plate in zinc chromate passivated MS box, including the cost of running 1.5 sq mm green colour FRLS PVC insulated copper solid conductor wire for loop earthing complete as per specifications and as required, including providing of 2x1.5 sq.mm. +1.5 sq.mm. (E) circuit wiring from DB to switch board. (Cost of MCB not to be included in this item) |
| 214 | Primary Point |
| 215 | Secondary Point |
| 216 | Wiring for MCB Controlled light point with 1.5Sqm FRLS PVC insulated multistrandeded copper conductor 1100 Volt grade wires in MS surface/concealed conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted modulr switch with moulded cover plate in zinc chromate passivated MS box, including the cost of running 1.5 sq mm green colour FRLS PVC insulated copper solid conductor wire for loop earthing complete as per specifications and as required, including providing of 2x1.5 sq.mm. +1.5 sq.mm. (E) circuit wiring from DB to switch board. (Cost of MCB not to be included in this item) |
| 217 | Primary Point |
| 218 | Secondary Point |
| 219 | Wiring forPrimary Power point Wiring for 6 pin 6/ 16 A Power plug point controlled by 16A Switch with 2 x 4 Sq. mm + 1 x 2.5 Sq.mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixing Modular 6 pin 6A/ 16 A socket outlet controlled by 16 A switch in zinc chromate passivated MS box, complete as per specification and as required. (raw +ups circuits both) |
| 220 | Secondary Looped Power point Wiring on the above circuit for 6 pin 6/ 16 A Power plug point controlled by 16A Switch with 3 x 4 Sq. mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixingof Modular 6 pin 6A/ 16 A socket outlet controlled by 16 A switch in zinc chromate passivated PVC box, complete as per specification and as required.(Looped socket on item above in same circuit) |
| 221 | Power point Wiring for a set of 6 pin 2x6/ 16 A Power plug point controlled by 1x16A Switch with 2 x 4 Sq. mm + 1 x 2.5 Sq.mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixing Modular 6 pin 2 nos.6A/ 16 A socket outlet controlled by 1 no. 16 A switch in zinc chromate passivated PVC box, complete as per specification and as required. (raw +ups circuits both) |
| 222 | Wiring for 5 pin 6Aplug point controlled by 6A Switch with 2 x 2.5 Sq. mm + 1 x 1.5 Sq.mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixing Modular 5 pin 6A socket outlet controlled by 6 A switch in zinc chromate passivated PVC box, complete as per specification and as required. (raw +ups circuits both) |
| 223 | Wiring for single phase 20A, 230 VIndustrial Socket & Plug Top in Moulded Plastic Box controlled by 20A SP MCB with 2 x 4 Sq. mm + 1 x 2.5 Sq.mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including providing of JB at Eqpt. Location, complete as per specification and as required. |
| 224 | Supply &installation of the following type of MCB\"S WITH IP55 BOX: |
| 225 | 40A-63 A , 4P MCB WITH BOX |
| 226 | 6A-32 A , 4P MCB WITH BOX |
| 227 | 6A-32 A , 2P MCB WITH BOX |
| 228 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\") |
| 229 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5 pin, 15/16 amps socket outlet |
| 230 | Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 231 | Supply and fixing of 18W LED Square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting |
| 232 | Supply and fixing of 18W LED Square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting with IP55 Protection |
| 233 | Supply & Fixing of T5 Light complete with all necessary hardwares for fixing as required |
| 234 | Supply & Fixing of LED stripswith driverin Cove complete with all necessary hardwares for fixing as required |
| 235 | Supply and fixing of Linear LED Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 105 lm/W. System wattage should not exceed 38W.The luminaire should have a color temperature of 6500K. The luminaire housing should be made of CRCA with a PC glossy diffuser. |
| 236 | Supply of 9W LED Bulkhead Luminaire with a nominal system lumen output of 700 lumens and system power consumption of 6.5W. The luminaire should have a color temperature of 6500K. The luminaire housing should be made of high pressure die cast Aluminium. Luminaire should be IP65 & IK08 rated. |
| 237 | Supply & Fixing of 12W LED spike Garden light.The luminaire housing should be made of high pressure die cast Aluminium. Luminaire should be IP65 & IK08 rated. |
| 238 | Supply & Fixing of 8W LED Wall Washer light.The luminaire housing should be made of high pressure die cast Aluminium. Luminaire should be IP65 & IK08 rated. |
| 239 | Supply & Fixing of Decorative Antique Chandelier Lights. 3000K Lamp with all necessary hanging arrangement |
| 240 | Supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 30W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour . |
| 241 | Point wiring for LAN points will be carried out withCAT 6, LAN Cable , in surface/ recessed PVC conduits, inclusive of p/f of G.I/ MS box & modular plate RJ 45 AT&T LAN socket.Work includes cutting & repair of chase to original finish. |
| 242 | Supply, Installation, Testing and Commissioning of 12 U Wall Mount Rack Indoor 600MM Wide, with front Door lock and key |
| 243 | Supply, Installation, Testing & Commissioning of 10 KVA UPS complete with sealed Maintenace free 12 V Battery for 30 Minutes back-up. |
| 244 | Design, manufacture , supply and fixing in position the cable trays of the following sizes for supporting 1.1 KV grade armoured/unarmoured aluminium /copper conductor cables. Fabricate the cable trays from perforated 1.6mm thick M.S. CRCA sheet duly galvanised with expansion coupler plates duly galvanised,with bolts, washer and nuts. Knock out holes for cable connections as per approved design. The tray should comply with the specification of NEC (National Electric Codes) and NEMA (National Electric Manufacturers Association). The steel should be as per IS:226 and galvanising as per IS :2629/BS 729/ASTM 123.The rate shall also include for supporting steel , fish plates , fixing accessories , nuts bolts, supporting down rods , dash fastener, cutting the RCC etc. complete as required. (the horizontal and vertical bends, T\"s should be factory fabricated and the rate should include for the same) |
| 245 | 150 mm wide x 40 mm x 1.6 mm thick |
| 246 | Supply, Installatiton, testing & commissioning of storage type ISI Marl 20L Vertical Type Instant Geyser along with all necessary hardwares required for fixing and necessary pipe connections. |
| 247 | Fire Alarm Panel - 2 Zone - Addressable Type complete with 4 hrs. battery back-up as required. |
| 248 | Gas Alarm Panel - 2 Zone - Addressable Type complete with 4 hrs. battery back-up as required. |
| 249 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 250 | Supply, Installation, Testing & Commissioning of Smoke detector with sensing chamber , 12/24 volt DC twin visual alarm indicater blink in stand by and steady in alarm (LED) camplete in al respect with Base as required |
| 251 | Supply, Installation, Testing & Commissioning of Heat detector with sensing chamber , 12/24 volt DC twin visual alarm indicater blink in stand by and steady in alarm (LED) camplete in al respect with Base as required |
| 252 | Supply, Installation, Testing & Commissioning of Gas detector with sensing chamber , 12/24 volt DC twin visual alarm indicater blink in stand by and steady in alarm (LED) camplete in al respect with Base as required |
| 253 | Supply, Installation, Testing & Commissioning ofResponse Indicator complete with Box as required |
| 254 | Supply, installation, testing and commissioning of Siren cum Strobe mount on surface / wall / false ceiling complete as required. |
| 255 | Supply, Installation, Testing & Commissioning ofManual Call PointBreak Glass Type housed in sheet Steel/ Polymer housing surface / Recess including Making connection with wire complete in all respect as per specification The manual call should have indicator which should blink in stand by condition. |
| 256 | Supply, installing, testing and commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W(Supply not in our scope only labour charge ) |
| 257 | Ceiling Mounted Speakers |
| 258 | Wiring for Music Speaker points to be carried out with of2 * 40/0.2 mm PVC insulated, twin twisted cable , in surface/ recessed PVC conduits.Wiring will begin from the Music System panel and will terminate in each shop as shown in the drawings. Work includes repairof chase to original finish. |
| 259 | installing, testing and commissioning of1X100W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. (Supply not in our scope only labour charge ) |
| 260 | Supplying and drawing of CAT 6 UTP wire in existing MS conduit |
| 261 | Supplying and laying of 25 mm dia MS conduit for CCTV Camera |
| 262 | Supply, Installation, Testing and Commissioning of 2MP x IR Fixed lens Turret Camera, 1920 X 1080 at 25/30fps,1/2.9\"CMOS, Fixed lens 2.8mm,H.265, H.264 compression,Smart Compression, internal 850nm IR Range 30 meter or better,Built in Microphone, 100dB true WDR as per IEC62676, Triple streaming, Motion Detection,Camera sabotage,IP66,IK10 Housing,Camera shall supportSD card 512GB or better ,ONVIF profile S,G, & T,NDAA,UL/cUL Listed, UL 60950-22, CE, FCC. |
| 263 | Supply, Installation, testing and Commissioning of Network Video Recording Storage System: Video management system - 32 channels. Support 340 Mbps bandwidth throughput capacity. Storage @ 720P with 20 FPS for 30 days recording. |
| 264 | Design, supply, installation, testing and commissioning of the following :Supplying, fixing & installing exhaust pipe fabricated out of5 mm thickClass B ERW and all fixing accessories and hardware for the following with 22G, aluminium sheet cladding& 50 mm thick 64 kg / cu M density mineral woolinsulation wrapped in chicken mesh including all supporting structure with arrangements like Supporting frames, Hooks, Clamps, Hardware & Fasteners Etc complete as required.Note : Vendor shall study the DG location and routing of flue gas exhaust pipe and suggest suitable size of ERW \"B\" class pipe and bends to achieve free flow of flue gas without developing any back pressure on turbocharger, size of the pipe shall be supported by back pressure design calculations. Individual exhaust system shall be provided.Diesel Generators - Prime duty application continuous rated 24/7 to provide full & continuous output as rated.Scope of supply shall include Monitoring of engine & Alternator, The Generator sets shall be suitable for Auto Mains failure, Load sharing & load dependent start/Stop, Suitable for Isolated/parallel operation system. The Generator shall have communication port with modbus protocol ( in case of any other protocol the vendor shall consider necessary convertor). The communication port shall be RS 485 and Ethernet.DG sets developing following capacity 3 phase, 415 volts, 50Hz, 4 wire system coupled to suitable BHP diesel engine,1500 RPM,4 stroke,Multi-Cylinder, electric start for giving power rating as per ISO 8528 Part I in KVA at the load terminals of alternator. The engine shall conform to IS 10000/ ISO 3046/BS 649/ BS 5514. Synchronous Alternator shall be of class Hinsulation, IP 23,brushless,self / separately excited,self regulated, SPDP enclosure,through AVR suitable to withstand tropical conditions and shall comply with BS 5000 / IS 4722. Quoted rates for each DG Sets shall include the following a. Required number of anti vibration mounting pads b. Required number of charged battery, battery stand, battery leads etc., c. Method of cooling - Engine driven radiator / Radiator with external power supply d. Duty Type - Prime Duty e. Ambient Temp - 45 Deg C (Design Ambient) f. Relative Humidity - 40% - 50% |
| 265 | 160 KVADiesel Generating Set is comprisingDiesel engine prime rated, Radiator Cooled Diesel Engine@ 1500RPM, Complete with standard accessories. COUPLED TOAlternator rated at 160 KVA, 415V, 50Hz, 0.8PF, Mounted on a Channel Iron Base Frame. DG set shall be supplied with machine acoustic enclosure, First fill lube oil, AVM pads, Batteries with Leads, First fill of coolant as per standards |
| 266 | Residential type silencer with spring support, suitable thickness and density of rock wool/ mineral wool insulation, chicken mesh and 22 G Aluminium Cladding, Pipe shall be as per IS 3589,GR.330(for 200 NB & above) and IS 1239,Part I (upto 150 NB pipe) inclusive of all supports, spring isolators , SS 304 expansion bellow, Y Joints complete with other necessary accessories for above mentioned DG sets |
| 267 | 200 mm dia MS Exhaust pipe including all necessary long bends, Short bends, Tees Etc. complete with insulation as above, flange, hardware and painting in approved color & MS support for exhaust pipe & residential silenced |
| 268 | Steel work as required to support the exhaust system. Related civil works shall beas per approved drawing and specifications. |
| 269 | Design, fabrication, supply, installation, testing & commissioning of LT Switchgear Panels as mentioned below strictly in conformity with IS:2675/BS:214 and construction shall be class of IP4X for Indoor and IP5X/6X for outdoor. The switchboard fabrication shall confirm to FORM-3B construction. The cubicle shall be of CRCA sheet steel, duly powder coated with polyester for out door and epoxy polyester for indoor. The switchboard shall be extendable type. The ACB / MCCB / MCB shall be approved make and of specified short circuit rating and suitable for breaker coordination. Suitable bus bars of high conductivity Copper/Aluminium strips and mounted on non- hygroscopic insulating supports shall be provided. All components shall be approved type of components of recommended make of switchgear components of suitable capacity as mentioned in the single line diagram and in conformity with technical specifications. |
| 270 | DG Syncronizing Panel suitable for 160kVA & 82.5kVA DG as per SLD |
| 271 | Main Distributin LT Panel as per SLD |
| 272 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 273 | Supply of minimum three star BEE rated Hi-wall Split Unit with rotary / reciprocating / scroll compressor, cordless control / thermostat, refrigerant charged, copper coil and aluminium fins for indoor, with inter unit connections & outdoor uniy of following capacity |
| 274 | 1.5 TR Capacity |
| 275 | 2.0 TR Capacity |
| 276 | Supply of minimum three star BEE ratedAir Cooled Normal Cassette Unit with rotary / reciprocating / scroll compressor, cordless control / thermostat, refrigerant charged, copper coil and aluminium fins for indoor, with inter unit connections & outdoor uniy of following capacity. |
| 277 | 2.0 TR Capacity |
| 278 | 3.0 TR Capacity |
| 279 | 4.0 TR Capacity |
| 280 | Installation, testing and commissioning of Hi-wall Split Unit, fixing of indoor unit on wall, outdoor unit hanging etc. as per detail drawing / Manufacturer recommendation. Connecting refrigerant circuit, drain pipe & other wiring & accessories as required. Contractor has to perform all standard test as required before handling over. |
| 281 | 1.5 TR Capacity |
| 282 | 2.0 TR Capacity |
| 283 | Installation, testing and commissioning of cassetteUnit, fixing of indoor unit on ceiling, outdoor unit hanging etc. as per detail drawing / Manufacturer recommendation. Connecting refrigerant circuit, drain pipe & other wiring & accessories as required. Contractor has to perform all standard test as required before handling over. |
| 284 | 2.0 TR Capacity |
| 285 | 3.0 TR Capacity |
| 286 | 4.0 TR Capacity |
| 287 | Supply,installation,testingandcommissioning of refrigerantpiping(twolengths, liquid + gas)dulyinsulatedwith15 mm thick nitrile rubber tube up to 15.9 mm diameter pipe, 25 mm thick nitrile rubber tube above 15.9 mm diameter pipe, finally finished with PVC tap wrapping,, permanent joining of copper pipe by brazing only, all bends have to be smooth & to be made by proper equipment. the refrigerant pipe to connect the indoor and outdoor unit including all the civil work (Separate cost Included below) such as chiseling, making hole in brick / block work for passing insulated refrigerant piping, or running these pipe on cable tray& finishing/ making good of civil work etc. The diameter, thickness and type of refrigerant pipe shall be as per unit’s Manufacturer recommendation. Contractor has to perform all standard test as required before handling over. |
| 288 | 1.0 TR / 1.5 TR / 2.0 TR Hi-wall |
| 289 | 2.4 TR / 3.0 TR / 3.5 TR / 4.0 TR Cassette Unit |
| 290 | Supply,installation,testingandcommissioning of condensate drainwaterpiping of PVC threaded type / push fit type complete withfittingslikeelbows,tees, reducers,bends,flanges,supports etc.As required conforming to drawing / specifications. Drain pipe will be duly insulated as per drawing / specification.Insulation shall bedonewithfireretardantclosedcellnitrilerubberof density 60 Kg/CMT, with thickness 9 mm up to 32 mm diameter pipeandwith 15 mm for morethan32 mm diameter pipefor indoor application. The drain piping to be laid with minimum 1% of slope including all the civil work (Separate cost Included below) such as chiseling, making hole in brick / block work for passing insulated drain piping, or running these pipe on cable tray& finishing/ making good of civil work etc. |
| 291 | 25 mm diameter pipe |
| 292 | 32 mm diameter pipe |
| 293 | Control cabling (PVC insulated, PVC sheathed copper flexible cable of 1.1 KV Grade), Control cabling will be run along refrigerant piping route only. |
| 294 | 1 x 4C x 2.5 Sq. (For Hi wall & Cassette Unit) |
| 295 | Supply and installation of GI perforated cable tray, with proper hanging arrangement, joining plate & etc. accessories as required, 50mm x 50mm cable tray of following sizes. |
| 296 | 150 mm wide |
| 297 | Supply & fixing of MS frames duly epoxy coated for outdoor units contractor has to ensure stable placement of unit on respective foundation along with vibration isolation pad as per detail drawing / specification. |
| 298 | Hi-Wall Split Unit Outdoor |
| 299 | Cassette Unit Outdoor |
| 300 | Performing civil work such as chiseling, making hole in brick / block work for passingpiping etc. with the help of appropriate tool Without damaging parent structure. |
| 301 | Supply,installation,testingandcommissioningof factoryfabricatedDoubleSkinnedAir-washer unit floormounted type fabricated outof extruded aluminium sectionwith0.6mm pre-plasticized/ pre-coated Galvanised steel sheet outside & 0.6 mm plain Galvanised steel sheet inside with backward curved blower, blower sectionandblowermotorTEFCtype of EEF-1 grade suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, beltdrivepackage, wet section & tank shall be made of18 Gtainlesssteel.The Air-washer shall becompletewithfillofdepth200 mm &face velocity acrossthe fill shallbelimitedto152 MPM. The Air-washershall haveanefficiencyof 90% &shallbecompletewithwatercirculation pump GI B Class interconnecting piping & valves Aluminum viscous filters. The Air-washershall haveanefficiencyof 90% &shallbecompletewithwatercirculation pump GI B Class interconnecting piping & valves Aluminum viscous filters. The airwasherpanelsshall beinsulatedwith23mmthick& 36 Kg/m³ density PU foam. The Airwasher shall conform tospecication given in the tender & shall be of following capacity. |
| 302 | 22,500 CFM, with suitable Dia. Fan,Fan Motor EEF-1 Grade, 60 mmSt.Pressure, 2 x HP SP Monoblock Pump (1W+1S) |
| 303 | Supply, installation, testing and commissioning of factory fabricated Double Skinned Scrubber unit floor mounted type fabricated out of extruded aluminium section with 0.6mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.6 mm plain Galvanised steel sheet inside with backward curved blower, blower section andblower motor TEFC type EEF-1 Grade Class H suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, belt drive package, wet section & tank shall be made of 18 G tainless steel. The Scrubber shall becomplete with spray arrangement with metallic viscous filter & face velocity acrossthe section shall be limited to 152 MPM. The scrubber shall haveanefficiencyof 90% &shallbecompletewithwatercirculation pump GI B Class interconnecting piping & valves, viscous filters. The scrubber panelsshall beinsulatedwith23mmthick& 36 Kg/m³ density PU foam. The scrubber shall conform tospecication given in the tender & shall be of following capacity. |
| 304 | 25,000 CFM, with suitable Dia. Fan,Fan Motor EEF-1 Grade, 65 mmSt.Pressure, 2 x SP Monoblock Pump (1W+1S) |
| 305 | Lifting, Shifting, Installation, Testing and Commissioning of packaged type Air washer unit & Air Scrubber unit, Stable placement of unit on respective foundation along with vibration isolation pad as per detail drawing / specification, connecting all wiring, cabling, ducting & other accessories as required to run unit acceptably. (Foundation is developed by civil contractor prior to unit installation taking consideration of all static & dynamic load of equipment & as shown in HVAC detail drawing. Powersupply with proper earthing, suitableisolators / MCB and appropriatestarter in BOH areashallbemadeavailablewithin 1 meter to equipment by Electrical Contractor, all plumbing connection will be done by plumbing contractor as per detail drawing / specification) HVAC Contractor has to ensure all technical & safety measures is been fulfilled before handling over. |
| 306 | 22500 CFM AIRWASHER |
| 307 | 25000 CFM AIR SCRUBBER |
| 308 | Supply, installation, testing and commissioning of Inline fans with suitable motor, suitable for 240 volts, 50 Hz, complete in allrespect&offollowing capacities.The inlinefans shall be selected for lower noise level. Fan motor shall have inbuilt speed controller.single phase power supply with sepatare circuit shallbemadeavailablewith theby Electrical Contractor |
| 309 | 1000 CFM 12 mm Static Pressure |
| 310 | 350 CFM 8 mm Static Pressure |
| 311 | Supply,installation,testingandcommissioning of Propeller Fan & suitable for 240 volts, 50 Hz, 900 RPM,singlephase AC supply complete with gravity louvers andspeed regulator etc. single phase power supply with sepatare circuit shallbemadeavailablewith theby Electrical Contractor |
| 312 | 100 CFM |
| 313 | 200 CFM |
| 314 | 350CFM |
| 315 | 450 CFM |
| 316 | 600 CFM |
| 317 | Supply installation testing & commissioning of exhaust hood is made of 20 swg.S.S-304 Sheet with S.S-304 baffle filters. Fitted with grease collection tray and hung, with suitable air openning of following sizes |
| 318 | 2850 mm x 1100 mm |
| 319 | 2700 mm x 1100 mm |
| 320 | 1700 mm x 1100 mm |
| 321 | Supply, fabrication, installation and testing of G.S.S. sheet metal ducting complete withSplitterDamper, vanes, Gasketing, MS rod & angle for hanging arrangement & etc other accessories as required as per specifications with SMACNA standard & as per detail drawing / specification. |
| 322 | 22 Gauge |
| 323 | 24 Gauge |
| 324 | 20 Gauge |
| 325 | 18 Gauge |
| 326 | Single louvered supply / return air registers (Grills), |
| 327 | Collar Damper Key Operated to Control air quantity at grill, Made out of heavy gauge GalvanizedSheetSteelconstruction, providedwithsuitablelinks and quadrants. TheDampers to be provided in all supply / return / fresh air / exhaust air Grill / terminals. |
| 328 | Supply, installation and testing of Duct Volume control Damper, Lever Operated, multiblade box type Made out of heavy gauge GalvanizedSheetSteelconstructiondamperfor ductsto beprovidedwithsuitablelinks and quadrants for control of volume of air. |
| 329 | Supply, Fixing of Canvas Connector shall be constructed of fire retarding flexible heavy canvas sleeve of suitable length, lint-free cloth, securely bonded and bolted on both sides with heavy gauge sheet. Sleeve shall be made smooth and the connecting ductwork rigidly held by independent supports on both sides of the flexible connection. The flexible connection shall be suitable for pressure point of system & eliminates vibration & noise in the air system. |
| 330 | Supply, fabrication and installation of MS base frame for fan, Air washer & outdoor units duly coated with anti-corrosive paint suitable for rust free outdoor installation as per detail drawing / specification. |
| 331 | Supplying, installation, testing & commissioning of Machine room less passenger lift / Goods Lift capacitiesas below of standard design conforming to latest lift act and modern lift with microprocesor including AC-VVVF controller in the existing lift well / shaft having minimum speed as mentined below with a total travel distance as mentioned below. Serving resepctive floors and landings as mentioned belwo.openings all on the same side. The lift shall be of SS Vandal proof finish stainless steel on all four sides, SS handrail Inner surface of Car door shall be and the landing door shall be scratch resistant / vandal proof stainless steel finish with two hours fire rated for the landing doors (lift vendor to submit certificates for the fire rating).The false ceiling should be SS # 4Stainless Steel finish.Girders required for lift insallations & providing miscellaneous items like supports for guide rails, additional steel member to adjust additional space of lift shaft, Lift pit ladder made of MS finished with two coats of anti corrosive paint, scaffoldings, sill projections, facia inside the lift well, minor building works like making sockets, holes etc.including making good the damages. The rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate ofGovernment of Mahrashtra for installation and commissioning of lifts before handing over the entire installation of the lift. |
| 332 | Supplying, installation, testing & commissioning of Type - Machine room less Dumbweight lift Location - Near Kitchen areaCapacity - 1000 Kgs Minimum speed - 1.5 m/sec Travel distance - 4.05 mtrs (approx). Serving - Ground and First floorStops - 2 stops Landings - 2 landings |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy