Tender For Construction Of 02 X Dog Kennel Near Guard Post Of 33 Fad Dappar Under Age ( I ) Dappar., dappar-Punjab

Military Engineer Services-MES has published Tender For Construction Of 02 X Dog Kennel Near Guard Post Of 33 Fad Dappar Under Age ( I ) Dappar.. Submission Date for this Tender is 26-08-2023. Building Work Tenders in dappar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39027991
Tender For Construction Of 02 X Dog Kennel Near Guard Post Of 33 Fad Dappar Under Age ( I ) Dappar.
Open Tender
Indian
Punjab
dappar
26-08-2023

Tender Details

Construction Of 02 X Dog Kennel Near Guard Post Of 33 Fad Dappar Under Age ( I ) Dappar.

Key Value

Document Fees
INR 500 /-
EMD
INR 10000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of 02 x Dog kennel near guard post of 33 FAD, Dappar under AGE (I) Dappar
Sl. No. Item Description
1B/R Portion
2Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified
3Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
5Removing Excavated material not exceeding 500M and n.exc 1.5 Km and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
6M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
7M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
8M&L for cement plastering 15mm thick in internal cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
9M&L for cement plastering 5mm thick in cement mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
10M&L for cement plastering 15mm thick in cemet mortar (in twor layers 10 mm+5mm) 1:4 including mixing of liquid water proofing compound as per manufacturer"s instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
11Supply only integral liquid water proofing compound complete all as specified and directed. Make : Pidilite/Sika
12M&L for preparation of newely plaster surfaces on wall and applying two coats of cement based paint on external plastered surfacesall as specified.
13M&L for preparation of newely plaster surfaces on internal wall and applying three coat of white wash on plastered surfaces all as specified.
14M&L for preparation of newely plaster surfaces of ceilingand applying three coats ofwhite wash all as specified.
15M & L for hardcore of broken stone or boulders exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface, complete all as specified
16M&L for 100 mm thick PCC (1:4:8) type D-2 using 40mm graded aggregate as in sub base of floor all as specified.
17M & L for 40mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate as floor finish complete all as specified and as directed by the Engineer-in-Charge
18M & L for reinforced Cement Concrete 1:2:4 type B1 using 20mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
19M & L for RCC 1:2:4 Type B1 using 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
20M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
21M&L formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup• ports, overhangs, etc. also splays between floors and beams, etc.for fair finishedflat surfacecomplete all as specified and directed by Engr-in-Charge.
22M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
23M&L Mild steel TMT bar 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking bending spirally hooping for column, hookingends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips quality conforming to, as in stirrups, spaces and binders complete all as specified and directed by Engr-in-Charge.
24M&L cast iron nahani/floor/multi floor trap 100mm dia including jointing with solvent cement in repair fixed in cement concrete (1:2:4) type B1complete all as specified and directed.
25Cuttingchases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting n. exc 10 cm girth complete all as specified.
26M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100mm bore pipe line complete all as specified and as directed by the Engineer-in-Charge
27S&Fgrating doom 100mm dia of PTMT (min weight 25gms) complete as specified and directed
28S&F welded steel wire fabric supplied and fixed complete to woods or steel members as directed completely by Engr-in-charge.
29S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe -290 including sliding tower bolts Gde E-165 complete all as specified and directed by Engr-in-Charge.
30M&L 50 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protection. Completef all as specified and directed by Engr-in-Charge.
31PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors as directed by engr-in-charge.
32S&F Mild Steel barrel tower bolts . Stoe enamelled black , with bright bolt and fixed
33S & F windows with side hung shutters including steel handle, and steel peg stay , compete with glazing bars, devetailed or welded completely as directed by Engr-in-charge.
34S & F 10 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
35M & l of new or previously untreated surfaces , priming withred oxide and painting with two coats Synthetic enamel (ordinary tint) completely as directed by Engr-in-charge
36E/M Portion
37M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutorsingle core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:- Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting PVC conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall.
38(a) One light/fan/ Bell point controlled by one switch
39(b) One socket outlet 5 Amps on theindependentboard with other switches.
40S&F Modular switch one way 6A/10A , 1 Module type single pole 240 volts of Anchor Roma Urban Cat Pat Code No 66101 10AX, 1Way Switch,HSN Code 8536 or equivalent in Legrand/Schneider specified colourcomplete all as specified and directed by the Engr-in-charge.
41S&F Socket, 6A- 2/3 pin combined 2 Module complete all specified.
42S & F Modular metal flusSh box 1/2module complete all specified.
43S & F Modular metal flusSh box 3 module complete all specified.
44S&F Modular White cover plate with frame, 2 module
45S&F Modular White cover plate with frame, 3 module
46S&F LED tube light fitting (including LED tube) 1 X 20W 230 Volt surface and wall mounted LED batten, extruded aluminium housing provided with efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with all accessories internallyprewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size fixed on wall/ceiling complete all as specified and directed.
47S&F connecting up testing and commissioning industrial corrosion proof IP 65 luminaire LED 30W suitable for security lighting made out of pressure die cast aluminium housing(including GI tubing 40mm dia, brackets, clamps and lamps) complete with all accessories prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed . Make: Havells
48Supply and fixingceiling rose bakelite, 63.5mm3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-Charge.
49Supply and fixingMCBSP 6 -32 Amps,10 KA,,"C" series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: L & T / ABB
50Supply and fixing 4 way power lineSPN distribution board 240 volts with double door fitted with Bus Bars 200amp, Neutral Links, Blanking Plates neutral bus bar, earth bar, dinbar, detachable gland plate , interconnectionsetc without MCB & ‘G FRAME’ complete all as specified and directed.Make :- ABB / L & T
51Supply and fixing MCB SPN 32 Amps,10 KA "c" series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: L& T / ABB
52M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-Charge.
53Supplying & FixingBracket fan ( Wall mounted Fan) 230W , single phase,oscillating 450mm sweep noiselesssuitable for wall mounting complete all as specified & directed. Make :- USHA / BAJAJ
54Supply and laying in trenches or fixing or passing through pipes or fixed to wall / pole 1100 volts gradeXLPE insulated, armoured heavy duty electric cableswith stranded aluminium conductorof cross sectional area 10 Sqmm 2 core complete all as specified and as directed.
55Supply & fixing 40 mm bore tubes, light grade galvanised with all fittings and fixed laid in trenches complete all as specified and directed
56Excavation in trenches in soft/loose soil n exc 1.5m wide andn. Exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for taking out embeded cables,brick/pcc protective tiles and relaying new/old cable complete allspecified and all as directed by engineer in charge.
57M&L sand cushioningng (drysand) to under ground cable for cable protection provided with layers 8cm deep before layingand 15 cm after laying the cable complete all as specified and directed.Note :- Punned thickness will be measured only.
58Supply and laying factory un reinforced precast concrete cable cover class LV, type-1, flat,size 250 x 150 x 40mm with ISI mark factory made complete all as specified & directed. Make-Mehtab Tiles(Indore)/Hind Mosaic(Upleta)
59Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n"exc 50 m above the starting point complete all as specified and directed.
60M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cablesize of cable 2x1.5 sqmm (line conductor) & 1x1.5 sq mm (earth conductor).1100 V grade drawing in & includingheavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note : (i)Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. For Building Street Light
61Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy