Tender For Skill Centre Under The Human Resources Development For Emergency Medical Services Scheme At Govt. Medical College Patiala, patiala-Punjab

Public Works Department-PWD has published Tender For Skill Centre Under The Human Resources Development For Emergency Medical Services Scheme At Govt. Medical College Patiala. Submission Date for this Tender is 21-08-2023. Building Work Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39020625
Tender For Skill Centre Under The Human Resources Development For Emergency Medical Services Scheme At Govt. Medical College Patiala
Open Tender
Indian
Punjab
patiala
21-08-2023

Tender Details

Skill Centre Under The Human Resources Development For Emergency Medical Services Scheme At Govt. Medical College Patiala

Key Value

Document Fees
INR 5000 /-
EMD
INR 175500.0 /-
Tender Value
INR 87.57 Lakhs /-

BOQ Items

Name of Work: Skill centre Under the Human Resources Developmentfor EmergencyMedical Services Scheme at Govt. Medical College, Patiala
Sl. No. Item Description
1Civil Work First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
2Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
3Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
4Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
5Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
6Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
7Scraping Cement plaster
8Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats
9Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standardtubular sections / appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
10Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness
11Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side.
12Providing Polyester Powder coating 50 micronany coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
13Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
14Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm 4mm thick or 10.78 Kg/ sqm
15Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
16Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm
17Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm)
18Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
19Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
20Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
21Dismantling brick work tile, masonry or tile lining In cement
22Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
23Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
24Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
25Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
26Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering insuperstructure. Ground Floor
27FIrst Floor
28Second Floor
29Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.
30Second Floor
31Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. Ground Floor.
32First Floor
33Second Floor
34Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. First Floor.
35Second Floor
36Centering and shuttering for sides and soffits of beambeams, launching girders, bressumers, lintels. Ground Floor
37First Floor
38Second Floor
39Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. First Floor.
40Second Floor
41First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. Ground Floor
42First Floor
43Second Floor
44Extra for work done in additional storey upto 4metre above the top of structural roof of lowerstorey for Brick Work/ Concrete Block/ ClayBlock. First Floor
45Second Floor
46Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block.
4720mm thick cement plaster 1:5 in two coat work
48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps. U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.
49Providing and fixing 110 mm dia. U.P.V.C bendfor Rain water pipe as per IS:14735 includingjointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
50Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm Coupling /Sockets
51Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
52Cement concrete 1:2:4 gola 10cm x 10cmconcave quadrant along junction of roofs withparapet wall finished smooth, where specially specified.
53Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
54Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggrigate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material
55Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
56Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
57Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
58Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
59Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
60Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge.
61Providing & fixing 16 gauge stainless steel pipe gate of grade 304 duly fixed at site with the help of M.S pivot & hinges grouted in cement concrete complete in all respect as per any kind of drawing & design
62Providing and fixing mineral fibre false ceiling tiles ( NRC 0.55 to 0.6) at all heights of size 595X595x16 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
63Providing and Fixing ceiling consisting of 12.5mmthick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and to the entire satisfaction of engineer-in- charge.
64First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
65Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
66Credit of Usefull Material Brick
67Credit of Usefull Material Brick Bats
68Add 5.35% for Difference of GST From 12% to 18 %
69ELECTRICAL SERVICES: ProvidingElectrical Installations for Lift:POINT WIRING: SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push,6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc., including the cost of above material and painting as required:- Wiring light point
70Wiring 3 pin 6 Amp. wall socket point
71COPPER WIRES & CONDUIT PIPE:PVC INSULATED INGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathedopper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed)
72Overall size 2.5sq.mm (Un-sheathed)
73Overall size 4sq.mm (Un-sheathed)
74PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed
75Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
76MCB"S & MCB DISTRIBUTION BOARDS: SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB"s: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&N distribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 4 way each
77MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 6-32amp. (10kA, Curve-C)
78MCB Double Pole 6-32amp. (10kA, Curve-C)
79LED"S FIXTURES & FANS: Supply and erection ofLED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
80XLPEINSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (Loose)
81XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
82DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
83COPPER EARTHING (8 SWG COPPER EARTHING): Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
84Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
85MCCB"s (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc. MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
86MS SHEET ENCLOSURE FOR MCCB"s: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shallbe made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/topwith cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
87Providing 1No. Lift13 Passenger Lift (2Stops): Supply, installation, testing and commissioning of 1 No. lift of 13 passengers machine room less. Type and Capacity :Approximately 884 Kg, 13 Passengers Speed:1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 4 meter________ Serving:_2 Floors _2Stops_2 Openings_2 Levels (All on the same side) Hoist way Required: 1900mm (Wide) x2600mm (Deep) Clear dimensions Headroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steelScratch proof Finish (Vandal Proof). Car Entrance: Center Opening Automatic Doors with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2000mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features.
88Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle"s, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level"s in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight. 29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.
89P.H. Works: Sanitary Installations Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. Eurpoean/Indian/Orissa W.C.,
90PVC / China Ware Cistern
91Wash Hand Basin / Urinal Pot
92Stainless Steel Sink /Mosaic Sink
93CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap
94Bathroom Assessories such as Soap Dish, Towel Rail, Towel Ring, Towel Bracket, Mirror, Toilet Paper Holder, Seat Cover, Jet Pressure and all other accessories.
95Providingin position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm diaincluding cost ofseat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
96Providing and fixing jet spray with 2"-6" long PVC pipe. With C.P. Brass nut
97Providing and fixing PVC Cistern 10 Ltr. Capacity ISI marked IS 7231:1994( size 32.5x47.6x15.5 cm) of approved make(to the approval of theEngineer-in-charge) including PVC fittings complete.
98Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm x 815 mm
99Size 560mm x 410mm (above counter oval)
100Providing and fixing in position 15mm C.P. Pillar cock foam flow of approved make (to the approval of Engineer-in-charge)
101Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling
102Providing and fixing in position vitreous Chinaware white Indian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm, C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
103Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm
104Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
105Providing and fixing C.P. brass Urinal Spreader Ocular-Regular complete with fittings for urinals complete.
106Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge) including carriage complete in all respect. Water Cooler Full Steel Body 150/150 ltr without Stablizer
107Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
108Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
109Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect
110Providing and fixingin positiontowel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring
111Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
112Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect. C.P. brass Bib cock long nose/ long body foam flow withoutflange
113C.P. brass Bib cock foam flow without flange
114Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge)complete in all respect. C.P.brass 15mm Concealed stop cock with flange
115C.P.brass 15mm Angle valve without flange
116Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect. PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut
117Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. copper tube connection of size 15 mm x 450 mm with C.P. Brass nut
118Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect.
119Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
120Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
121Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. Vertical type 25 litre capacity water heater
122Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. 15mm internal diametre pipe line.
12320mm internal diametre pipe line.
124CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 16mm o/d
125SDR 11 CPVC pipes & fittings 20mm o/d
126SDR 11 CPVC pipes & fittings 25mm o/d
127EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. CPVC SDR 11 pipes & fittings o/d 40mm
128Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition Size 75 mm x 75 mm
129Providing, fixing and jointing CPVC Union Couplings 25mm complete in all respect.
130Providing, fixing and jointing CPVC Union Couplings 40mm complete in all respect.
131Cutting holes upto 23cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 11.43 cm thick
132Through wall 22.86 cm thick
133Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects.
134Dismantling H.C.I Soil pipes including disposal as desired by the Engineer-in-Charge. 100mm i/d H.C.I. pipe
13575mm i/d H.C.I. pipe
136Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Type B 110mm o/d SWR UPVC pipe line laid complete
13790mm o/d SWR UPVC pipe line laid complete
138Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipes Single Tee With Door
139Elbow 90 Degree (All side socketed)
140Vent Cowls
141Coupler
142P Trap/Floor Trap 110mm x 110mm
143For 90mm o/d pipes Single Tee With Door
144Elbow 90 degree (all side socket)
145Vent Cowls
146Coupler
147Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) 110mm o/d
14890mm o/d
149Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
150Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks
151Providing and fixing in position automatic brass Ball Cock in tanks. Plastic Ball Cock with rod and Plastic Ball 25mm i/d
152Providing, fixing and jointing CPVC Tank Nipple 25mm complete in all respect.
153Providing, fixing and jointing CPVC Ball valve 25mm complete in all respect.
154Construction of Plateform for Water Storage Tanks
155Dismantling of Marble Flooring
156Supplying and filling cinder on roof (Ist story) including light ramming (Labour rate for removing cinder)
157Supplying and filling cinder on roof (Ist story) including light ramming.
158Screed of 40mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
159Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
160Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
161Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete
162Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
163Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm,200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
164Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
165Centeringandshuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
166Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
167Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
168Removing Flush Door of existing size at site.
169Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below.
170Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area up to 0.50 sqm
171Factory manufactured Solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
172Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats
173For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
174Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
175Providing & fixing ACP Sheets of various thickness High Class ISI markedcomplete in all respect as per the directions of Engineer-in-charge. 4mm thick ACP Sheet
176Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
177Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
178Applying pink primer or aluminumpriming coat on wood work including preparation of surface knotting and stopping etc.
179Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. (For doors & windows)
180Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
181Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
182Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoatof1mmthickofneat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conformingto I.S.I complete as per standard design. Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
183600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal
184Providing and fixing in position PVC gully traps 100mm fixed in cement concrete 1:4:8 complete with SFRC cover with frame weighing 7.26 Kg. 300mm x 300mm including Grating complete in all respects.
185Excavation of trenches in a Streets, Lanes or in Open Area for Storm Sewers and Manholes to Full Depths as Shown in Drawings,excluding Shoring, Timbering of Poling Board Frame System Type, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines.night signals, profiles, Pegs, Sight rails, boning rods, crossing over trenches for access to the houses, watching, fencing etc., fixing and maintenance of caution boards, refilling trenches, watering of refill in 15 cm layers, ramming and restoration of surface to original conditions and removal of Surplus Spoil from the Site of Works, for all Works other than connections to Ventilating Shafts upto a Lead of 15 mtr For depth not exceeding 2 m. below Ground level For all classes of soil except rocky 9x0.66x0.77 = 4.57 cum
186Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 160mm o/d pipe
187Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixerand vibrator, TMTFe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 75x120 cm and 120 cm deep
188Carriage of Old dismantled malba with tractor trolly.
189Credit of old HCI pipe 100 mm i/d
19075 mm i/d
191Fire Extinguishers Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 6 Kg. Capacity
192Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 4.5 Kg. Capacity
193Air Conditioners Providing and installing 3 starfixed speed Split Type AC make Voltas/Mistubishi/Blue Star or any other equivalent make remote control fittedwithreturn cooled rotary Compressor operating on latest eco-friendly refrigrant suitable wall mounting as per site requirement and approval of Engineer-in-Charge including cost of MS outer stand floor/wall mounted and 3 mtr refrigrant copper pipe complete in all respects.For 2 Ton
194For 1.5 Ton
195Providing and fixing refrigerant copper pipe of imported make with insulation and vinyl tape of suitable size as per tonnage complete in all respects.
196Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (50/0.25mm), 3Core
197Supply and Fixing MS iron Stand Floor/Wall Mounted
198AUTOMATIC VOLTAGE STABLIZER Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 4 KVA
199Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. uPVC Pipe 10 Kgf/cm2 25mm i/d 14 No x 10 mtr each
200Servicing of 1.50 TR capacity
201Gas filling including leakage testing of Split AC 1.50 TR