}

Tender For Iaq Measuring Instrument, bargur-Tamil Nadu

Directorate Of Technical Education-DTE has published Tender For Iaq Measuring Instrument. Submission Date for this Tender is 14-08-2023. Electrical Products Tenders in bargur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

39019588
Tender For Iaq Measuring Instrument
Open Tender
Indian
Tamil Nadu
bargur
14-08-2023

Tender Details

Iaq Measuring Instrument , Electrical Items : , Measured Parameter By Instrument = Volume Flow / Air Velocity, Pressure, Radiant Heat, Co2 Features Of Instrument = System Shall Be Operated Both From Mains & Battery Run Minimum Of 6-8 Hrs. Internal Memory ( Min 2 Gb ) To Store Readings S.No Parameter Tender Specifications 1 Type: Main And Batteryoperated Portable Iaq Instrument System Should Be Configurable & Up Gradable As Per The Userrequirement Magnetic Mounting For Easy Operations Instrument Shall Have Minimum Ofmain Camera: 8.0 Mp &Camera: 5.0 Mp Provision For Data Transfer To Pc / Laptop. 2Specification Of Iaq Data Logger Type: Compatible Portable Iaq Data Logger Measured Parameter By Iaq Data Logger Compatible With Probes Formeasuring Comfort Level, Radiant Heat, Co2, Air Flow Velocity, Humidity, And Temperature Along With Date & Time Features Of Instrument Data Logger Configurable Via Iaq Instrument Connect To Six Fixed Cable Probes At The Same Time Stand-Alone Data Logger For Long-Term Measurements Up To 2 Weeks Universal Iaq Instrument ( And The Iaq Data Logger ) , A Maximum 1 Million Readings Shall Be Recorded. 3 Specifications Of Rotating Vane Probe For Air Velocity Measurement Including Temperature Sensor: Type: Vane Type Vane Diameter:100 Mm Range:Up To 35 M / S, ( Min: 0.3 M / S ) Accuracy:± 3 % Of Reading Cable Length:Min 1Meter Temperature Sensor Range / Accuracy -20 To +70 °C / ±0.5 °C 4 Specifications Of Additional Probes: Probe For Measurement Of Ambient Temp, Abs Pressure, Humidity, Co2 Temp Range / Accuracy:0 To +50 °C / ±0.5 °C Humidity Range / Accuracy: 5 To 95 %Rh / ±3 %Rh Abs Pressure: Up To 1.1 Bar Co2 Range 0 To 10, 000 Ppm Co2 Cable Length:Min 1 Meter 5 Accessories Tripod Tripod With Provisions To Hold The And Probes ( Including Tripod Bag ) System Case Hard Carrying Case With Provisions To Accommodatethe Instrument 6 Infrared Thermometer • Infrared Thermometer For Measuring Temperature Of Objectsurface. •Should Be Gun Type With Trigger / Button For Operation. •Temperature Display Unit Should Be Degree Celsius And Degreefahrenheit, With Interchangeable Modes. Spectral Range 8 To 14 ?M •Measurement Range Infrared: -30 To +400 °C •Lcd Display With Back Light •Accuracy Infrared: ±2 °C •Two Adjustable Alarm Limit Values ( Lower & Upper Limit ) •Battery Life Continuous Use 10 Hours

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: < IAQ MEASURING INSTRUMENT >
Sl. No. Item Description
1Electrical Items :
2Measured Parameter by instrument = Volume Flow/Air Velocity, pressure, radiant heat, CO2 Features of instrument = System shall be operated both from Mains & Battery run minimum of 6-8 hrs. Internal Memory (min 2 GB) to store readings S.No Parameter Tender Specifications 1 Type: Main and Batteryoperated Portable IAQ instrument System should be configurable & up gradable as per the userrequirement magnetic mounting for easy operations Instrument shall have minimum ofMain camera: 8.0 MP &camera: 5.0 MP Provision for data transfer to PC / laptop. 2Specification of IAQ Data Logger Type: Compatible Portable IAQ Data Logger Measured Parameter by IAQ DATA Logger Compatible with probes formeasuring comfort level, radiant heat, CO2, air flow velocity,humidity, and temperature along with date & time Features of instrument Data logger configurable via IAQ instrument Connect to six fixed cable probes at the same time Stand-alone data logger for long-term measurements up to 2 weeks Universal IAQ Instrument (and the IAQ data logger), a maximum 1 million readings shall be recorded. 3 Specifications of Rotating Vane Probe for Air Velocity measurement including temperature sensor: Type: Vane type Vane diameter:100 mm Range:Up to 35 m/s, (min: 0.3 m/s) Accuracy:± 3 % of reading Cable length:Min 1meter temperature sensor range/Accuracy -20 to +70 °C / ±0.5 °C 4 Specifications of Additional Probes: Probe for measurement of Ambient Temp, Abs Pressure, Humidity, CO2 Temp range/ Accuracy:0 to +50 °C / ±0.5 °C Humidity range/ Accuracy: 5 to 95 %RH / ±3 %RH Abs Pressure: Up to 1.1 Bar CO2 Range 0 to 10,000 ppm CO2 Cable length:Min 1 meter 5 Accessories Tripod Tripod with provisions to hold the and probes (including tripod bag) System case Hard carrying case with provisions to accommodatethe Instrument 6 Infrared Thermometer • Infrared Thermometer for measuring temperature of objectsurface. •Should be gun type with trigger / button for operation. •Temperature display unit should be Degree Celsius and degreeFahrenheit, with interchangeable modes. Spectral range 8 to 14 µm •Measurement Range Infrared: -30 to +400 °C •LCD display with back light •Accuracy infrared: ±2 °C •Two adjustable alarm limit values (Lower & Upper Limit) •Battery life continuous use 10 hours
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail