| 1 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 2 | Filling of carted earth. |
| 3 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proner completion of work |
| 4 | Providing and laying cement concrete 1:4:8 (1) cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete |
| 6 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M- 20. |
| 7 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M- 20. |
| 8 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M- 20. |
| 9 | First Class brick work in 1:6 cement and coarse sand of 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse candl |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 11 | Painting on DPC with two coats of air blownbitumen 85/50 or 85/25 @ 1.7 kg/sqm. Approxincluding cost of fuel if any. |
| 12 | Same as in item No. 9 above but in super- structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement: coarse sand) |
| 13 | Same as in item no. 12 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 14 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 15 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 17 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. Providing & fixing of hold fasts. |
| 18 | Providing & fixing of door/windows grill. |
| 19 | Fabrication of Z-section steel windows (openable) |
| 20 | Angle iron chaukhats |
| 21 | Fixing of steel or wooden chaukhatsin position. (a) Door chaukhats |
| 22 | (b) Window chaukhats |
| 23 | 15 mm thick plinth plaster [1 cement: 4 coarse sand] |
| 24 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement: 6 coarse sand |
| 25 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement: 6 coarse sand. |
| 26 | Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 27 | Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 200:200pcal |
| 28 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 29 | Cement concrete flooring 1:2:4 (1 cement 2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 30 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement. 20 mm thick. |
| 31 | Finishing wall with water proofing cement paint of approved make such as Super snowcem, Duracem, Robiance, Guttucem, Supercem quality and of required shade on undecorated wall surface (one coat) over and including one coat white cement primer to give abd even shade after thoroughly after brushing the surface to |
| 32 | Distempering (Two coat) with oil of PWD-4 PWD (PWD([WD-bounddistemper approved brand andmanufacture & of required shade on undecorated wall surface to give an evenshade over & including a priming coat with cement primer of approved brand &manufacture such as Berger, J&N, ShalimarAsian paints after thoroughly brushingthe surface free from mortar droppings &other foreign matters & also includingpreparing the surface even with plasterof paris or approvedsynthetic material &sand papered smooth including cost ofallmaterials. |
| 33 | Painting Ist coat over priming coat (butexcluding cost of priming coat) on steeland other metal surfaces up to 10 cm.width or girth or small articles notexceeding 0.10sqm in area white superiorsynthetic enamel such as LUXOL3,HI- glossapcolite superlac, specifiedbrushing to give an DULUX even shade andincluding cleaning the surface of alldirt, dust and other foreign matter sandpapering and stoping including cost ofall materials, labour tools and plantsetc. required for proper completion ofthe work. |
| 34 | Painting Ist coat over priming coat (butexcluding cost of priming coat) on steeland other metal surfaces up to 10 cm.width or girth or small articles notexceeding 0.10sqm in area white superiorsynthetic enamel such as LUXOL3,HI- glossapcolite superlac, specifiedbrushing to give an DULUX even shade andincluding cleaning the surface of alldirt, dust and other foreign matter sandpapering and stoping including cost ofall materials, labour tools and plantsetc. required for proper completion ofthe work. |
| 35 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting ofvarious oparation. |
| 36 | Construction of drain alongwith apron. |
| 37 | Providing & fixing stainless steel sliding doorbolts ISI marked complete. (a) 300mm x 16mm. |
| 38 | Providing & fixing stainless steel tower bolts ISI marked complete. |
| 39 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm |
| 40 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes |
| 41 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 42 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 43 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and id, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to 15 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: W.C. pan with 151 marked black solid plastic seat and lid |
| 44 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 45 | Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. |
| 46 | Providing and fixing 600x450mm beveled edge mirror of superior glass (or approved quality) complete with 5mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete |
| 47 | Providing and fixing white vitreous china flat back half stall urinal of size $80-380-350mm with white PVC automatic Bushing cistern, with firings, standard size CP. brass fush pipe, spreaders with unions and clamps Call in D.P. brass) with waste fitting as per 15: 2556 CI. trap with outlet grating and other couplings in CP brass including pointing of things and cutting and making good the walls and floors wherever required: Range of single half stall urinals with 5 litre PV.C. automatic flushing cistem |
| 48 | Providing and haing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fived in Unnal partitions by cutting a chase of appruriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:24 tlcement: 2carse sand: 4graded stone aggregate 6mm nominal size as per direction of Engineer-in-charge and finished smooth |
| 49 | Providing and hung unplasticised PVC connection ppe with brass unions |
| 50 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer-in-charge. |
| 51 | Providing and fixing C.P. brass bib cock of approvedquality conforming to 15:8931 |
| 52 | Providing and fixing C.P. brass long body bib cock ofapproved quality conforming to IS standards andweighing not less than 690 gms. (for sink) |
| 53 | Providing and fixing C.P. brass angle valve for basinmixer and gyser points of approved quality conforming to IS:8931 |
| 54 | Providing & fixing sod, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside 15:15905 a) 100mm dia centrifugally cast iron S&S pipe. |
| 55 | b) 75mm dia centrifugally cast iron 5 & 5 pipe |
| 56 | Providing lead caulked joints to sand cast irony/centrifugally cast (spun) iron pipes & fitting of diameters 100mm |
| 57 | 175mm |
| 58 | Providing & fiving M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Soun) iron S 65 pipe embeded in & including cement concrete blocks 10x10x10cm, of 1:2:4 mix (1 cement 2 coarse: 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.for 190mm dia.pint |
| 59 | for 75mm dia pipe. |
| 60 | Providing & fixing cast iron coller. A) 100 mm dia |
| 61 | b)75 mm dia |
| 62 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good thewalls and floors:a) 100mm inlet & 100mm outlet. |
| 63 | Providing and fixing bend of required degree with accessdoor, insertion rubber washer 3mm thick, bolts and nuts 100 mm |
| 64 | 75 mm |
| 65 | Providing and fixing plain bend of required degree.a) 100mm |
| 66 | b)75 mm |
| 67 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100mm |
| 68 | 75x75x75mm |
| 69 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 100x100x100mm |
| 70 | 75x75x75mm |
| 71 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75 mm |
| 72 | Providing and fixing single unequal plain invert branch of required degree: 100x100x75mm |
| 73 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.) 100 mm |
| 74 | 75 mm |
| 75 | Providing and fixing cast iron terminal guard. 100 mm |
| 76 | 75 mm |
| 77 | Providing and laying cement concrete 1:5:10(1 cement: S coarse sand: 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring/ground) 110 mm dia |
| 78 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion, 110 mm |
| 79 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gan for thermal expansion.Coupler 110 mm |
| 80 | Bend 87,5 degree 110 mm Bend |
| 81 | Shoe (Plain) 110 mm Shoe |
| 82 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 arams. |
| 83 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse |
| 84 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a |
| 85 | Providing and fixing Chlorinated Polyvinyl Chiride fittings Vc fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and makingoood the walls etc 20mm dia nominal.miter dia. |
| 86 | 25mm dia nominal outer dia pipes |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal bore |
| 88 | 25mm dia nominal bore |
| 89 | 32 mm dia nominal bore |
| 90 | Providing and fixing gun metal gate valve with wheel of approved quality 20mm die nominal bore |
| 91 | 25mm die nominal bore |
| 92 | 32 mm die nominal bore |
| 93 | Providing and Foxing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 94 | Excavating trenches in all kinds of soil of required width for pipes, including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated sell & then returning the sail as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer try ramming, watering, etc & disposing of surplus cated solas directed within a lead of Stun up to 1.50 m depthD.5.R Pipes 80 mm to 300 mm diameter |
| 95 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement: 21 fine sand) including testing of joints etr complete 150 mm, dia. RCC Pipes |
| 96 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes Including bed concrete as per standard design |
| 97 | Constructing brick masonry manhole in cement mortar1:4 (1 cement 4 coarse sand) RCC top slab with 1:2:4) mix (1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement 4 coarse sand 8 graded stone aggregate 40mm nominal size) inside plastering 12mm. thick with cement mortar 1:3 (1 cement 3 coarse sand] finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement 2 coarse sand 4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement Inside size 90x80cms and 45cms deep including C cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of With common burnt clay FPS (non modular) bricks of class designation 75 |
| 98 | Inside size 90x120cms and 90cms deep including CT cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kol With common burnt clay FPS (non modular) bricks of class designation 75 ) For Sewer Line |
| 99 | Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 100 | Excavating trenches in all kinds of soil of required width for pipes, including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the sol as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated sod as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter |
| 101 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement: 21 fine sand) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 102 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard desion D.S.R 150 mm, dia. |
| 103 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of With common burnt clay FPS (non modular) bricks of |
| 104 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |