Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-01-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-01-2024 |
| 2 | 22-12-2023 | Revised drawings | Other | 02-01-2024 |
| 3 | 22-12-2023 | BOQ and other amendment to tender | BOQ | 02-01-2024 |
| 4 | 22-12-2023 | 8th Date Corrigendum 22 Dec 2023 | Date | 02-01-2024 |
| 5 | 08-12-2023 | Date corrigendum 08 Dec 2023 | Date | 29-12-2023 |
| 6 | 28-11-2023 | Amendments to tender documents | Other | 15-12-2023 |
| 7 | 28-11-2023 | Date Corrigendum dated 28 Nov 2023 | Date | 15-12-2023 |
| 8 | 24-11-2023 | TD Drawing 4 | Other | 08-12-2023 |
| 9 | 24-11-2023 | TD Drawing 3 | Other | 08-12-2023 |
| 10 | 24-11-2023 | TD Drawing 2 | Other | 08-12-2023 |
| 11 | 24-11-2023 | TDDrawing 1 | Other | 08-12-2023 |
| 12 | 24-11-2023 | Main Drawings | Other | 08-12-2023 |
| 13 | 24-11-2023 | Amendment to BOQ and other tender documents | BOQ | 08-12-2023 |
| 14 | 09-11-2023 | Date Corrigendum 09 Nov 2023 | Date | 08-12-2023 |
| 15 | 27-10-2023 | 4th Date Corrigendum | Date | 24-11-2023 |
| 16 | 13-10-2023 | 3rd Date corrigendum | Date | 07-11-2023 |
| 17 | 22-09-2023 | Date Corrigendum no 02 | Date | 21-10-2023 |
| 18 | 06-09-2023 | Date corrigendum 01 | Date | 30-09-2023 |
| Sl. No. | Item Description |
| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . |
| 3 | Sch A Part II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II. |
| 5 | Sch A Part III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III . |
| 7 | Sch A Part IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV . |
| 9 | Sch A Part V (EXTERNAL ELECTRIFICATIONS) |
| 10 | Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part V. |
| 11 | Sch A Part VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI. |
| 13 | Sch A Part VII (AREA DRAINAGE) |
| 14 | Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII |
| 15 | Sch A Part VIII(ROAD/PATH AND CULVERT) |
| 16 | Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ Part VIII |
| 17 | Sch A Part IX(GARBAGE BIN) |
| 18 | Lump sum price worked out by the contractor for Garbage Bins as listed in Sch ‘A’ Part IX |
| 19 | Sch A Part X (CHAIN LINK FENCING & GATE) |
| 20 | Lump sum price worked out by the contractor for Fencing & Gate as listed in Sch ‘A’ Part X |
| 21 | Sch A Part XI (DEMOLITION OF BUILDINGS) |
| 22 | Lump sum price worked out by the contractor for Demolition of Buildings as listed in Sch ‘A’ Part XI |
| 23 | Sch A Part XII (HOT WATER SUPPLY) |
| 24 | Lump sum price worked out by the contractor for HOT WATER SUPPLY as listed in Sch ‘A’ Part XII |
| 25 | Sch A Part XIII (SITE CLEARANCE) |
| 26 | Lump sum price worked out by the contractor for Site Clearance as listed in Sch ‘A’ Part XIII |
| 27 | Sch A PartXIV (Miscellaneous Items of B/R and E/M) |
| 28 | M&L for Cleaning of MH up to 1.50 RM deep and taking out sludge, night soil, sludge water etc manually and removing the same to a distenace upto 5km outside of MoD land and burried under ground working in foul condition complete all as directed. |
| 29 | M&L for Cleaning of MH exceeding 1.50 RM & not execeding 3.0 RM deep and taking out sludge, night soil, sludge water etc manually and removing the same to a distenace upto 5km outside of MoD land and burried under ground working in foul condition complete all as directed. |
| 30 | Supply and fixing brassY-strainerwithSS 304 filter 20 mm bore ISI Markedcomplete all as specified and directed. |
| 31 | S&F in rep ABS plastic speed bump / speed breakers in parabolic convex shape and of size 750 mm x 250 mm x 70 mm made out of steady plastic, dovetail interlocking sub units, jointed and fixed to make the bump perfectly uniform, bump made out of precolourd material (black or yellow) and UV stablizers to keep them perfectly colourful, studded with reflectors on either side to make it clearly visible to motorists during night hours complete all as specified and directed. |
| 32 | Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 200 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed.Notes:-(i) Excavation earth works shall be measured and paid separately.(ii) Joints CI/DI specials shall be measured and paid separately.(iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate. |
| 33 | All as per item Ser No. 14.05 above but bore of DI pipe 150 mm (6”) Class K-7 --ditto. |
| 34 | All as per item Ser No. 14.05 above but bore of DI pipe 100 mm (4”) Class K-7 --ditto. |
| 35 | All as per item Ser No. 14.05 above but bore of DI pipe 80 mm (3”) Class K-7 --ditto. |
| 36 | S & F CI/DI pipe fittings / specials such as bends,tapers, tee pieces single branch, \"Y\" junction, collars, caps and plugs, M J collar etc spigot socketed or flanged ends type of size upto 200 mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure-A of IS: 9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure \"B\" of IS-9523/2000) complete all as specified and directed.Note:-(i) Excavation and earth work shall be measured and paid separately.(ii) Joints and jointing material shall be measured and paid separately. |
| 37 | Supply and fixing Pumping sets, centrifugal, electric driven, 7.5 HP, 3 Phase discharge min 650 LPM min Head 30 M with stand wide voltage fluctuation from 300-440 Volt, conforming to IS: 9079-2002, suction lift upto 7.5 meters, IP-44 protections, class -F insulation, coupled with pump including suitable coupling as per manufacturer instruction and nuts, bolts and foundation angle iron frame and PCC foundation complete all as per manufacturer design complete all as specified and directed. |
| 38 | Supply and fixing DOL starter 3 phase, AC, 400/440 volts, 50 Hz suitable for pump set of cap 7.5 HP conforming to IS IEC 60947-4-1, IP-54, Class H Insulation, Internal wiring FRLS complete all as specified and directed. |
| 39 | Supply and fixing 3 core flat copper cable of size 6 Sqmm as per ISI 1554/IS-694 including thimble, chasing of pcc flooringand wall complete all as specified and directed. |
| 40 | Material and labour for valve pit chamber of size internal dimensions 1050x1050x 1200 mm by using 100mm thick PCC 1:4:8 type D-2 using 40 mm crushed stone aggregate as in foundation, brick work one brick thick wall with sub class \"B\" bricks in CM (1:4) of thickness 230 mm, coping with PCC 1:2:4 type B-1 using 20mm crushed stone aggregate, rendering plastering 15mm thick on brick masonry valve chamber surface in cement sand mortar in 1:4 upto top & out side of chamber upto 15 mm height, flooring with 40mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate, laid over 75mm thick hard core including supply and fixing of mild steel sheet cover made out of 3 mm thick plain black sheet with 3 No\"s 150 mm long mild steel butt hinges, welded to angle iron frame and shutter including handle and locking arrangement, angle iron frame made out of 40x40x6 mm thick (Fe-410-0) complete including painting to steel work with two coat of synthetic enamel paint over one coat of red oxide primer all as specified |
| 41 | Supply, install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements for 6 nos energy meters, made out of 2 mm thick CRCA sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the approved drawing by GE and comprising of following accessories :-a) Four pole MCCB, 40 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.b) Copper Bus Bar of size 25mm x 3mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.c) MCB SPN 16 Amps, 10 KA breaking capacity- 6 Nosd) MCB SP 06 Amps, 10 KA -3 No (For common lighting & Bldg Security Lights)e) Analog time switch 16 Amp-01 Nof)LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos.g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nosh) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up,24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light).j) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :-(i) MCCB to Bus Bar - 10 Sqmm copper busbars(ii) Bus Bar to Cable Connector via KWh meter and MCB - 4.0 Sqmm copper(iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm copper |
| 42 | Supply and Installation ofSmart RF Single Phase Meter with the following specifications:• AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 Volt, 50 Hz, 10 Amp-60 Amp conforming to IS: 16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.• Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software• Meter should have connect / disconnect functionality operable from billing software• The meter should support open communication protocol DLMSwith the softwareNotes: Meters would have 5 years OEM Warranty |
| 43 | M & L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground (earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less then 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI earth lead wire of 4 mm dia (7.5 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel, wire mesh, earthing test point etc complete including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B-1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in Electric plate no.3 of SSR-2009 (Part-I) and testing on completion completeall as specified and directed.Note :- (i) GI strip and GI pipe medium grade up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm thick, fixed with necessary nuts and boltson angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose. |
| 44 | Supply, installation, testing & commissioning of 11 KV, 630 Amps, 21kA for 3 sec outdoor type, IP-54 protection, floor mounted both side extensible 4-way SF-6 gas insulated floor mounted with copper bus bar Compact Switchgear should consist of 02 Nos incoming Vacuum Circuit Breaker and 02 Nos outgoing Vacuum Circuit Breaker and 01 No air insulated Bus PT panel with Battery & Battery Charger. The coupling should be at the top of compact switchgear through sleeved busbars covered with insulating boots at the joints. All live parts, bus bars, VCB will be enclosed in robotically welded 2 mm thick stainless steel tank filled with SF-6 at 1.4 bar with IP class IP-54 protection, leak rate less than 0.1% and tested as per latest IEC: 62271-200 and 2mm GI or 3 mm CRCA enclosure. Compact Switchgear shall be with fixed type VCB for 11 KV system 50 Hz AC three phase including earth fault and over current protection and motor operated spring charging mechanism for Vacuum Circuit Breaker. While refilling the SF6 gas the manometer should be able to show the pressure inside the stainless steel tank with a dedicated gas topping up arrangement on the LV panel. The switchgear should be tested for Internal arc for both tank and cable box IAC AFLR (21kA-1 Sec) venting through bottom. Totally enclosed confirming to relevant IEC standard with fitting of protection relay with indicators as under: |
| 45 | A)Incomer VCB - 02 Nos consisting of following:-(a) Motor operated 630 Amp Vacuum Circuit Breaker having two position spring mechanism. Motor control voltage 24 Volt DC.(b) Three position disconnector / earthing switch downstream vacuum circuit-breaker.(c) Three position single spring mechanism for disconnector / earthing switch.(d) Anti-reflex operating handle.(e) Capacitive voltage indication fixed type VPIS 12 KV.(f) Emergency Trip push button to operated VCB. (g) 3O/C + 1E/F self-powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. (h) Ring core current transformer of suitable ratio 2.5 VA, SP-10 for protection - 03 Nos.(i) Ring core current transformer of suitable ratio, 2.5 VA, class 1.0 for metering - 03 Nos.(j) Digital Multifunction meter for measuring energy and power parameter like Volt, Amp, KW, KVAr, KWh, PF, Hz(k) Mechanical ON/OFF/EARTH indication. (l) Electrical ON/OFF indication with Green & Red LED lamp.(m) Cable boxes suitable for 1 X 3C x 300 sqmm XLPE cable with right angle Touch proof Cable Termination kits.(n) Cable boxes should be 21KA for 1sec Internal Arc Proof with all safety interlocking. |
| 46 | B)Outgoing VCB - 02 Nos consisting of following:-(a) Motor operated 630 Amp Vacuum circuit breaker having two position spring mechanism. Motor control voltage 24 Volt DC.(b) Three position disconnector/earthing switch downstream vacuum circuit-breaker.(c) Three position single spring mechanism for disconnector/earthing switch. (d) Anti-reflex operating handle. (e) Capacitive voltage indication fixed type VPIS 12 kV.(f) Emergency Trip push button to operated VCB. (g) 3O/C + 1E/F self-powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. (h) Ring core current transformer of suitable ratio, 2.5 VA, 5P10 for protection - 03 Nos (i) Ring core current transformer of suitable ratio, 2.5 VA, class 1.0 for metering - 03 Nos(j) Digital Multifunction meter for measuring energy and power parameter like Volt, Amp, KW, KVAr, KWh, PF, Hz(k) Mechanical ON/OFF/EARTH indication. (l) Electrical ON/OFF indication with Green & Red LED lamp.(m) Cable boxes suitable for 1 X 3Core x 300 sqmm XLPE cable with right angle Touch proof Cable Termination kits.(n) Cable boxes should be 21kA for 1sec Internal Arc Proof with all safety interlocking. |
| 47 | C)Bus Connected PT Unit consisting of following:-(a) 03 Nos single phase voltage transformers of the ratio 11KV/v3 / 110 V/v3, 50 VA, Class 1.0 with HT fuses in the primary and MCB on the secondary side. (b) Volt-meter with selector switch.(c) Fixed type sheet with Anti-vandal type screw arrangement to avoid unauthorized access.(d) R Y B Phase indication. (e) Bushings for external busbar connection along with Busbar cover & Sleeved busbars for coupling. (f) 2X12 Volt Battery with Battery Charger with suitable burden for motor operation. Input 230 Volt AC & Output 24 Volt DC.Note:-Rateof PCC foudation as per manufacturer instruction included in the quoted rate. |
| 48 | Supply, laying, testing & jointing XLPE Insulated cable, screened, PVC bedded, galvanized steel strip or wire armoured, electric cable (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 630 Sq mm single core complete all as specified and directed.Note: Earthwork, Sand cushioning, brick/PCC cover, GI pipe shall be measured and paid separately under relevant items. |
| 49 | Supply, laying, testing & jointing XLPE Insulated cable, screened, PVC bedded, galvanized steel strip or wire armoured, electric cable (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 400 Sq mm single core complete all as specified and directed.Note: Earthwork, Sand cushioning, brick/PCC cover, GI pipe shall be measured and paid separately under relevant items. |
| 50 | Supply and laying burnt clay designation 75(Kg/cm2) old size bricks in cable trenches as cable protection complete all as specified and directed. |
| 51 | M & L for cable route indicator made out of CI plate 100mm dia, 6mm thick & fixed over angle iron of size 40mmx40mmx6mm, 450 mm in length duly painted with aluminium paint suitable for HT/LT cable including embedded in PCC (1:3:6) type C-1 using 20mm crushed stone aggregate of size 300x300x200mm in ground complete all as specified and directed. |
| 52 | Supply, Installation, testing and Commissioning CPRI approved factory made totally enclosed, IP-54 protection dust, weather and vermin proof, CRCA sheet out door LTPanelfor 415Volt, 3 phase 4 wire 50 Hz, AC system with TPN tinned aluminium bus bar of rating 1500 Amps, DMC/FRP insulator with short circuit with stand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar, general construction confirming to IS: 8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switch gears with required size (minimum 1.5 Sqmm) PVC insulated copper conductor cable , cable alloys, cable gland plates in two half inculding LED indicating lamp for all phasesand mounted on suitable PCC foundation for the complete panel base with following detailed specification control and accessories complete:- |
| 53 | OUTER SHELL :- The outer shell shall be made of min 3 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges, single door system, lockable / openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air.The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite sizeglands.Provision of earthing studs at bottom and threadedlifting lugs of suitable size at top to lift the feeder pillar box safely shall be made.Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. |
| 54 | INNER SHELL :-Inner shell made of 2 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable / openable with \"U\" type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment) All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequite size of lugs.The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer.A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. |
| 55 | INCOMING MCCBa) ACB 4 Pole, 415 Volt, withMicro processor release (Manual Drawout type) of capacity 1000 Amps 50 KA. -01 NoOUTGOING MCCB:-a)MCCB with fixed thermal fixed magnetic release 500 Amps, 4 Pole , 50 Hz, 415 Volt with rupturing capacity 35 KA-01 Nob)MCCB with thermal fixed magnetic release 400 Amps, 4 Pole , 50 Hz, 415 Volt with rupturing capacity 35 KA-01 Noc)MCCB with thermal fixed magnetic release 100 Amps, 4 Pole , 50 Hz, 415 Volt with rupturing capacity 16 KA-01 No- 01 No. |
| 56 | MISCELLANEOUS ITEMS :- (a) MCB SP 6 to 10 Amps 10 KA (For Control Wiring) - 03Nos. INSTRUMENTATION SYSTEM :-a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED,YELLOW & BLUE)b) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 No.c) Digital Ammeter 0-500 Amps (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 N0d) CT having Ratio 1000/5, tape wound, BPL, rated burden 15 VA - 03 Nos.(e) Volt meter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.f) Ammeter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.g) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos. |
| 57 | Note :(1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.(2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.(3) All the inner / outer doors should have locking facility through castle locks(4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this.(5)The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments.(6) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. |
| 58 | Supply, Installation, testing and Commissioning CPRI approved factory made totally enclosed, IP-54 protection dust, weather and vermin proof, CRCA sheet out door LTPanel for 415Volt, 3 phase 4 wire 50 Hz, AC system with TPN tinned aluminium bus bar of rating 1500 Amps, DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar general construction confirming to IS: 8623/93, havingbottom base channel of MS section not less than 75mm x 75 mm x 5 mm, entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switch gears with required size (minimum 1.5 Sqmm) PVC insulated copper conductor cable, cable alloys, cable gland plates in two half inculding LED indicating lamp for all phasesand mounted on suitable PCC foundation for the complete panel base with following detailed specification control and accessories complete:- |
| 59 | OUTER SHELL :- The outer shell shall be made of min 3 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges, single door system, lockable / openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air.The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite size glands.Provision of earthing studs at bottom and threadedlifting lugs of suitable size at top to lift the feeder pillar box safely shall be made.Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. |
| 60 | INNER SHELL :-Inner shell made of 2 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable / openable with \"U\" type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment)All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs.The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer.A detachable predrilled gland plate of thickness 3.15 mmshould be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. |
| 61 | INCOMING MCCB:a)MCCB with fixed thermal and fixed magnetic based relese 400 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 35 KA-01 NoOUTGOING MCCB:-a)MCCB with fixed thermal and fixed magnetic based relese 100 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 25 KA- 04 Nos (01 No Spare)b)MCCB with fixed thermal and fixed magnetic based relese 63 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 16 KA - 01 Nos.c)MCCB with fixed thermal and fixed magnetic based relese 40 Amp, 4 Pole , 50 Hz, 415 Volt with rupturing capacity 16 KA- 01Nos |
| 62 | MISCELLANEOUS ITEMS :- (a) MCB SP 6 to 10 Amps 10 KA (For Control Wiring) - 03Nos. INSTRUMENTATION SYSTEM :-a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED,YELLOW & BLUE)b) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 No.c) Digital Ammeter 0-500 Amps (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 N0d) CT having Ratio 1000/5, tape wound, BPL, rated burden 15 VA - 03 Nos.(e) Volt meter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.f) Ammeter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.g) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos. |
| 63 | Note :(1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.(2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.(3) All the inner / outer doors should have locking facility through castle locks(4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this.(5)The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments.(6) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. |
| 64 | Supply, Installation, testing and Commissioning CPRI approved factory made totally enclosed, IP-54 protection dust, weather and vermin proof, CRCA sheet out door LTPanel for 415Volt, 3 phase 4 wire, 50 Hz, AC system with TPN tinned aluminium bus bar of rating 1500 Amps, DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar general construction confirming to IS: 8623/93, having bottom base channel of MS section not less than 75mmx75 mm x 5 mm entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switch gears with required size (minimum 1.5 Sqmm) PVC insulated copper conductor cable, cable alloys, cable gland plates in two half inculding LED indicatinglamp for all phasesand mounted on suitable PCC foundation for the complete panel base with following detailed specification control and accessories complete:- |
| 65 | OUTER SHELL :- The outer shell shall be made of min 3 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges , single door system, lockable/ openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air.The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite sizeglands.Provision of earthing studs at bottom and threadedlifting lugs of suitable size at top to lift the feeder pillar box safely shall be made.Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. |
| 66 | INNER SHELL :-Inner shell made of 2 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable / openable with \"U\" type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment)All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs.The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer.A detachable predrilled gland plate of thickness 3.15 mmshould be used at the bottom, an inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. |
| 67 | INCOMING MCCBa) MCCB with fixed thermal and fixed magnetic based relese 100 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 16 KA - 01 No.OUTGOINGS MCCBa) MCCB with fixed thermal and fixed magnetic based relese 40 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 16 KA -05 Nos (01 No Spare) |
| 68 | MISCELLANEOUS ITEMS :- (a) MCB SP 6 to 10 Amps 10 KA (For Control Wiring) - 03Nos. INSTRUMENTATION SYSTEM :-a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED,YELLOW & BLUE)b) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 No.c) Digital Ammeter 0-500 Amps (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 N0d) C.T. having Ratio 1000/5, tape wound, BPL, rated burden 15 VA - 03 Nos.(e) Volt meter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.f) Ammeter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.g) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos. |
| 69 | Note :(1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.(2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.(3) All the inner / outer doors should have locking facility through castle locks(4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this.(5)The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments.(6) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. |
| 70 | Supply, Installation, testing and Commissioning CPRI approved factory made totally enclosed, IP-54 protection dust, weather and vermin proof, CRCA sheet out door LTPanelor 415Volt, 3 phase 4 wire, 50 Hz, AC system with TPN tinned aluminium bus bar of rating 1500 Amps, DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar general construction confirming to IS: 8623/93, havingbottom base channel of MS section not less than 75mm x 75 mm x 5 mm entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switch gears with required size (minimum 1.5 Sqmm) PVC insulated copper conductor cable, cable alloys, cable gland plates in two half inculding LED indicating lamp for all phasesand mounted on suitable PCC foundation for the complete panel base with following detailed specification control and accessories complete:- |
| 71 | OUTER SHELL :- The outer shell shall be made of min 3 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges, single door system, lockable / openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air.The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite sizeglands.Provision of earthing studs at bottom and threadedlifting lugs of suitable size at top to lift the feeder pillar box safely shall be made.Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. |
| 72 | INNER SHELL :-Inner shell made of 2 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable / openable with \"U\" type gasket to make the inner shell completely vermin proof having chromium platedlocks (2 Nos in each compartment)All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs.The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer.A detachable predrilled gland plate of thickness 3.15 mmshould be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. |
| 73 | INCOMING MCCBa)MCCB with fixed thermal and fixed magnetic based relese 63 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 16 KA -01 No.OUTGOINGS MCCB:-a)MCCB with fixed thermal and fixed magnetic based relese 40 Amp, 4 Pole, 50 Hz, 415 Volt with rupturing capacity 16 KA -03 Nos. (01 No Spare) |
| 74 | MISCELLANEOUS ITEMS :- (a) MCB SP 6 to 10 Amps 10 KA (For Control Wiring) - 03Nos. INSTRUMENTATION SYSTEM :-a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED,YELLOW & BLUE)b) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 No.c) Digital Ammeter 0-500 Amps (96mm x 96mm), 4 1/2 digit Accuracy Class 1% - 01 N0d) C.T. having Ratio 1000/5, tape wound,BPL, rated burden 15 VA - 03 Nos.(e) Volt meter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.f) Ammeter selector switch (6 Amps), 3 position with \"OFF\" - 01 No.g) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos. |
| 75 | Note :(1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.(2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.(3) All the inner / outer doors should have locking facility through castle locks(4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this.(5)The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments.(6) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. |
| 76 | Supply and fixing GI bracket made with 40 mm dia GI pipe light grade length 1.20m long bent to an angle of 135 degree and reduce at the end dia to match with the street light dia including suitable 02 set of clamps of size (50X5)mm with nuts, bolts and washers for fixing of light fitting to pole complete all as specified and directed. |
| 77 | Supply & Fixing Weather Proof thermo plastic (Polysterene) Cable Junction box, having protection class IP-66 protection and of overall size min (155 x 210 x 92) mmhaving metric knockouts on the wall, duly fixed with the pole with terminal (25x3mm)clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including cable Lugs 16 Sqmm -08 Nos complete all as specifed and directed . |
| 78 | Supply & Fixing three core PVC insulated flexible cable cord 1.5 Sqmm multi-stranded copper conductor flexible cables 1100 Volts grade complete and making connection from cable junction box to streetlight fitting complete all as specified and directed. |
| 79 | M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50RM below ground level) connected to galvanised iron strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm thick, PCC chamber using PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm crushed stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted MS Plate of (size 300x300x3mm thick) duly welded with angle iron of size 40x40x5mm, 600mm long, fixed with the earth pit chamber by grouting complete all as specified and directed.Note :- (i) GI strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm thick, fixed with necessary nuts and bolts on angle iron of size 40x40x5mm, 600 mm long and grouted with PCC block of size 200x200x250mm (PCC 1:3:6 using 20mm crushed stone aggregate including necessary earth work for marking the result and purpose. |
| 80 | Shifting of distribution transformer HT 11 KV, three phase, LT 433 volt four wire of capacity up to 750 KVA using man power / crane / transport vehicle required location at AF Station including re-installation at new location, commissioning and making all HT/LT connection and testingto restore the electric supply including fulfilling any other requirement for smooth funtioning of transformer complete all as directed by GE.NOTES:- For shifting of transformer in existing location to new location shall be required mechanical instrument such as crane & vechicles including loading / unloading / shifting cost will be born by bidder and shall be deemed included in the quoted rate, no any claim entertained on this account at later stage. |
| 81 | Shifting of distribution RMU 11 KV using man power / crane / transport vehicle required location at AF Station including re-installation at new location, commissioning and making all HT/LT connection and testingto restore the electric supply including fulfilling any other requirement for smooth funtioning of RMU complete all as directed by GE.NOTES:- For shifting of RMU in existing location to new location shall be required mechanical instrument such as crane & vechicles including loading / unloading / shifting cost will be born by bidder and shall be deemed included in the quoted rate, no any claim entertained on this account at later stage. |
| 82 | Shifting of high mast light upto 16 M height including disconnecting the existing connection taken down the flood light keeping safe custody by using man power / crane / transport vehicle to required location at AF Station incluiding re-installation at new location, commissioning and testing making all LT connection to restore the electric supply & including any other requirement for smooth funtioning and shifting ofhighmust light complete all as directed by GE.NOTES:- For shifting of highmust light in existing location to new location shall be required mechanical instrument such as crane & vechicles including loading / unloading / shifting cost will be born by bidder and shall be deemed included in the unit quoted rate , no any claim entertained on this account at later stage. |
| 83 | M & L for boring of holes under road, pavement, hard standing by pneumatic drilling machine by trenchless technology including HDPE pipe 100 mm dia insertion in the hole complete all as specified and directed. |
| 84 | Cutting the existing hard standing for passing pipe / cable and making good the disturbed surfaces by using 150 mm thick 1:4:8 in foundation type D-2 using 40mm graded crushed stone aggregate as in mass concrete complete all as specified and directed. |
| 85 | Taking down carefully submain wiring with aluminium conductor cable 4/6 Sqmm in PVC conduit complete and making good the disturbed surface of wall/floor etc. |
| 86 | Taking down carefully unserviceable TPN/SPN DB complete and making god the disturbed surface of wall/floor etc. |
| 87 | Deduct Schedule of Credit of Rs. 13,93,395.00 as brought out from Sr Page No. 51 of tender |