Tender For Electrification, Dg, Cctv, Solar System, Fire Alarm, Fire Fighting And Hvac System Works At 50 Bedded Ccu At Medical College Srinagar (Pauri Garhwal) Under Pm-Abhim, Pauri Garhwal-Uttarakhand

Bridge Ropeway Tunnel and Other Infrastructure Development Corporation of Uttarakhand Limited-BRIDCUL has published Tender For Electrification, Dg, Cctv, Solar System, Fire Alarm, Fire Fighting And Hvac System Works At 50 Bedded Ccu At Medical College Srinagar (Pauri Garhwal) Under Pm-Abhim. Submission Date for this Tender is 01-09-2023. CCTV System Tenders in Pauri Garhwal Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

38993269
Corrigendum : Tender For Electrification, Dg, Cctv, Solar System, Fire Alarm, Fire Fighting And Hvac System Works At 50 Bedded Ccu At Medical College Srinagar (Pauri Garhwal) Under Pm-Abhim
Open Tender
Indian
Uttarakhand
Pauri Garhwal
01-09-2023

Tender Details

Tender For Electrification, Dg, Cctv, Solar System, Fire Alarm, Fire Fighting And Hvac System Works At 50 Bedded Ccu At Medical College Srinagar ( Pauri Garhwal ) Under Pm-Abhim

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Aug-2023 date extension Date 01-09-2023

Key Value

Document Fees
INR 5900 /-
EMD
INR 434000.0 /-
Tender Value
INR 2.17 Crore /-

BOQ Items

Name of Work:Electrification, DG, CCTV, Solar System, Fire Alarm, Fire Fighting and HVAC System works at 50 Bedded CCU at Medical College Srinagar (Pauri Garhwal) Under PM-ABHIM
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group c
3Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
4Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
6Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.
72 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
82 X 10 sq. mm + 1 X 6 sq. mm earth wire
94 X 6 sq. mm + 2 X 6 sq. mm earth wire
104 X 10 sq. mm + 2 X 6 sq. mm earth wire
114 X 16 sq. mm + 2 X 6 sq. mm earth wire
12Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit
132 Pair
144 Pair
15TV cable in existing conduiting:Supply & drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in existing surface/ recessed steel/ PVC conduit as required.
16Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1720 mm
18Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1920 mm
2025 mm
21Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
225/6 A switch
2315/16 A switch
243 pin 5/6 A socket outlet
256 pin 15/16 A socket outlet
26Telephone socket outlet
27TV socket outlet
28Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
291 run of cable
30Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
31Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
32Supplying and fixing of modular Blanking plate on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd.
33Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
341 or 2 Module (75mmX75mm)
353 Module (100mmX75mm)
364 Module (125mmX75mm)
376 Module (200mmX75mm)
38Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
39Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
40Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
41Supplying and fixing brass batten/ angle holder including connection etc. as required.
42Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
43Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
44Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
45Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
46Upto 450 mm sweep
47Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
48Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
49GROUP C
50Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
5112 way , Double door
52Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
534 way (4 + 12), Double door
546 way (4 + 18), Double door
55Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
56Single pole
57Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5863 A
59Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6040 A
61Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6240A
63Supplying & Fixing of following rating four pole (three phase and neutral) 415 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 300 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6425A
6540A
66Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
67Supplying and fixing 30 A/32A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A/32A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
68Providing and fixing M.V. danger notice plate of 200x150mm ,made of mild steel at least 2mm thick ,vitreous enameled white on both sides ,and with inscription in single red colour on front side as required.
69Cable Trays
70Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
71150 mm width X 50 mm depth X 1.6 mm thickness
72Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
73150 mm width X 50 mm depth X 1.6 mm thickness
74Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
75150 mm width X 50 mm depth X 1.6 mm thickness
76Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
77150 mm width X 50 mm depth X 1.6 mm thickness
78Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
79Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
80Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
81Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
82Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
83Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
84Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
85Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
86Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
87Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
88Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
89Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
90Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
91Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
92cable laying
93Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
94Upto 35 sq. mm
95Above 95 sq. mm and upto 185 sq. mm
96Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
97Upto 35 sq. mm
98Above 95 sq. mm and upto 185 sq. mm
99Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required.
100Upto 35 sq. mm
101Above 95 sq. mm and upto 185 sq. mm
102Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface and overhead as required.
103Upto 35 sq. mm (clamped with 1mm thick saddle)
104Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
105Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
1063½ X 120 sq. mm (45mm)
1073½ X 185 sq. mm (45mm)
1084 X 10 sq. mm (25mm)
109Erection of metallic/octagonalpole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
110Above 8.0 metre and upto 10.0 metre
111Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
112100 mm dia
113150 mm dia
114Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
11563 mm dia (OD-63 mm & ID-51 mm nominal)
116INTELLIGENT FIRE ALARM SYSTEM
117Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
118Two Loop Panel.
119Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required
120Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
121Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
122Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required
123Supplying, installation, testing & commissioning of addressable manual call point complete as required.
124Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
125Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
126Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
127Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
128Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
129VRF SYSTEM
130OUTDOOR UNIT
131Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.
132INDOOR UNIT - CASSETTE
133Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
1341.6 TR
135INDOOR UNIT - HIGH WALL TYPE
136Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
1371.65 TR
1382.0 TR
139INDOOR UNIT - DUCTABLE TYPE
140Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
141Low static ductable units (minimum 25 pascal external static pressure)
1421.6 TR
143High Static Ductable units (minimum 110 pascal external static pressure)
1448.0 TR
145COPPER REFRIGERANT PIPING
146Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
1479.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
14812.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
14915.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15019 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15122.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15225.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15328.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
154DRAIN PIPING
155Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge
15625 mm outer dia pipes.
157DUCTING, GRILLS, DIFFUSER AND INSULATION
158Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
159Thickness 0.8 mm sheet
160Thickness 1.0 mm sheet
161Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
162Thickness 0.8 mm sheet
163Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room.
164Damper
165Actuator
166Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
167Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
168Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
169Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
170Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.
171200mm Dia
172Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications
173Fire Damper
174Actuator
175Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
176Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
17719 mm
17825 mm
179SUB-HEAD I : FIRE FIGHTING SYSTEM
180PUMPS
181Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
182Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
183Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325.
184M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
185Suitable cement concrete foundation duly plastered and with anti vibration pads.
1861620 lpm at 56 m Head
187Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
1881620 lpm at 56 m Head
189Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
190180 lpm at 56 m Head
191CONTROL PANELS
192Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
193INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication, Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter. All standard relays and accessories for automatic operation of diesel engine System Controller. Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
194PIPES & ACCESSORIES
195Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
19625 mm dia
19732 mm dia
19840mm dia
19950 mm dia
20065 mm dia
20180 mm dia
202100 mm dia
203Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
204Single headed Gunmetal
205Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
206100 mm dia
207Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
20840 mm dia
209Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete required.
210Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
211Gun Metal
212Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required; -20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 -20 mm nominal internal dia gun metal globe valve & nozzle. -Drum and brackets for fixing the equipmets on wall. -Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
21330 mtrs
214Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
215Gun Metal
216Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
217Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
218Pendent Sprinkler
219Upright Sprinkler
220Horizontal side wall sprinkler
221Concealed sprinkler
222Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
223Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
224100 mm dia
225150 mm dia
226Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
227100 mm dia
228Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
229700 mm
2301000 mm
2311200 mm
232Providing and placing on terrace (at all floor levels) Polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement amd making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
233SUB HEAD B - NON SCHEDULE ITEMS
234LIGHTING FIXTURES
235Supply of 20 Watt LED Linear Metal Construction commercial batten fitting with fuse protection suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for both surface & suspended Mounting, complete in all respect 2200 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side ofexisting MS pipe (in case of hanging )complete accessories all respectand as directed by engineer in charge., Make PRIMA WARM WHITE ALUMINIUM CIRCLE
236Supply of2" * 2" panel light30 watt/3600 lumenssuitable for Polycarbonate diffuser & aluminium heat sink complete suitable for recessed Mounting, complete in all respect 3600 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side ofexisting MS pipe (in case of hanging )complete accessories all respectand as directed by engineer in charge., Make SYSKA COOL DAY LIGHT ALUMINUM SQUARE LED IS:10322
237Supply of Downlighter 15 wattsuitable for Polycarbonate diffuser & aluminium heat sink complete suitable SURFACE Mounting, complete in all respect 2000 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side ofexisting MS pipe (in case of hanging )complete accessories all respectand as directed by engineer in charge., Make Led Surface Ceiling Light-IS:10322 KE Warm White Aluminium Circular LED surface ceiling Light KER
238Supply of TubeLight 24 watt/2400 lumenssuitable for Polycarbonate diffuser & aluminium heat sink complete suitable for Surface Mounting, complete in all respect 2400 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side ofexisting MS pipe (in case of hanging )complete accessories all respectand as directed by engineer in charge., Make SYSKA LED BATTEN24W
239Supply of TubeLight 10 watt/1150 lumenssuitable for Polycarbonate diffuser & aluminium heat sink complete suitable for Surface Mounting, complete in all respect 1150 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side ofexisting MS pipe (in case of hanging )complete accessories all respectand as directed by engineer in charge., Make GYYNC LED BATTEN10W
240Supply of 10W LED BULKHEAD (MEKE LEDGEAR PLASTIC LED BULKHEAD)
241Supply ofPROPELLAR TYPE AC VENTILATION EXHAUST FAN AS PER 2312
242Supply, installation, testing and commissioning of following ennealed tinned electric grade copper conductor PVC insulated and PVC sheathed jelly filled armoured telecommunication cable as per specifications.make finolex
24310 pair armoured riser cable of 0.60 mm dia copper conductor
24420 pair armoured riser cable of 0.60 mm dia copper conductor
245Supply and installation, testing and commissioning following size FABIO Mild steel Telephone Junction Box make telephone tag block in lockable 16 gauge sheet medium duity PVC enclosure complete as required.
24610 pair Krone type tag block
24716 pair FABIO type tag block
248Supply and Erecting modular type computer jack RJ 45 with screwless connector approved make with mounting plate and box with wiring connections complete. D-LINK RJ45
249Supply of following sizes of XLPE insulatedAluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.
2504CX16 SQMM AL ARMOURD CABLE
2513.5CX50 SQMM AL ARMOURD CABLE
2523.5CX95 SQMM AL ARMOURD CABLE
2533.5CX150 SQMM AL ARMOURD CABLE
254Supply of following sizes of XLPE insulatedCopper Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.
2552CX 2.5 SQMM Cu ARMOURD CABLE
256Supply of LED streetlightfitting not more than 45WSESSP LED STREET LIGHT having System Efficacy >120 lm/W, system output >3600Lumens,THD<10%,PowerFactor>0.95,CRI>70,CCT 5700,Full IP66 ( with out Glue) protectedsinglepiecediecastaluminium housing having toughned glass/PC with Impact resistance IK07. LED driver should be Fully metal body Potted & Encapsulated . BIS compliant driver should sustain440V Stress Voltage protection for 8 Hrs., High Cut off : 325V(+/- 15V) and should have feature of Auto Restart. Driver shall have 4KV Surge protection and feasibility of 10KV external SPD housed in Luminiare and confirming standard IEC60598. Including suitable size GI pipe bracket clamps, nut, bolts and washers complete all as directed. Make : SESSPLED STREET LIGHT FORM GEM APP.
257Supply of 9.0 Mtr Height Galvanized Iron OctagonalPoles having uniformly tapered polygonal shape throughout the length with straightLongitudinal welding in a single shaft. There shall not be any circumferential welding. Dimensions:Top Dia.: 70mm, Bottom Dia.: 135mm, Thickness 3mm &Base plate 275*275*16 mm. Dimension of Foundation Bolts - Length 600mm, Dia. 24mm &04 Nos. Bolts manufactured from special steel along with nuts, washer, anchor plates & Templates. SingleArm of 0.5 Mtr. Shall be provided along with – MAKE GEM ITEM SALESMART STREET LIGHT POLE
258LT PANELS
259MAIN LT PANEL- -Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & outdoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or eqivalent as per approved make list and as direction by engneer in charge. PTTA Panel
260INCOMER:
2611 nos. 630A415V, Ics=50KA, 4P MCCB with TM release having adjustable O/L, S/C protection.
2621 nos.Digital type multi function meters (V+A+Hz) with cast resin CTs 200/5A.
2631 Set of phase indicating lamp with MCB
264BUSBAR
265800A TPN Bus bar of aluminimum alloy.
266OUTGOINGS
267- 250 A, TPN,36KA, MCCB – 1 N.o.
268- 200 A, TPN,36KA, MCCB – 1 N.o.
269- 160 A, TPN,36KA, MCCB – 1 N.o.
270- 125 A, TPN,36KA, MCCB – 4 N.o.
271- 63 A, TPN,10KA, MCCB – 9 N.o.
272- 40 A, TPN,10KA, MCB – 4 N.o.
273- 63 A, DP,10KA, MCB – 3 N.o.
274CAPACITOR SECTION
275SECTION –1
276INCOMER
277250 A, 3 Pole, MCCB with U/V release and shunt release with a minimum of 5 NO and 5NC auxiliary contacts and with following :-
278METERING & CONTROLS
279- breaker ON/OFF/TRIPindicating lamps with control fuses.
280- shunt trip coil
281Automatic Power Factor
282correction system with following :
2831 number solid state Binary mode
284automatic power factor sensing and
285correction relay complete in all
286respects ( 6 stages)
287The APFCR relay will be from the DUAL SOURCE MULTIFUNCTION METER FROM TRINITY- MODEL- "POWER CUBE".The relay will have different set points for the mains supply & generator supply.
288LT Power Capacitor Banks along with contactors and HRC fuses as detailed below:
2892 number TP Contactors of 63 A Capacity with MCB – 25 kVAR
2901 number TP Contactors of 63 A Capacity with MCB – 20 kVAR
2914 number TP Contactors of 40 A Capacity with MCCB – 10 kVAR
2923 number TP Contactors of 32 A Capacity with MCCB – 5 kVAR
293GROUND FLOOR PANEL
294INCOMER FROM MAIN LT PANEL
295125A TPN ,50KA, MCCB
296METERING & INDICATION
2971 sets of phase indicating lamps
2981 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
2991 Sets of Breaker ON-OFF-TRIP,
300BUS BAR as per SLD:-
3011 Sets of 150A, TPN Aluminum bus bars with colour coded sleeves.
302OUTGOINGS
303- 63 A, TPN,10KA, MCB – 2 N.o.
304- 40 A, TPN,10KA, MCB – 3 N.o.
305- 32 A, TPN,10KA, MCB – 4 N.o.
306FIRST FLOOR PANEL
307INCOMER FROM MAIN LT PANEL
308125A TPN ,50KA, MCCB
309METERING & INDICATION
3101 sets of phase indicating lamps
3111 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
3121 Sets of Breaker ON-OFF-TRIP,
313BUS BAR as per SLD:-
3141 Sets of 150A, TPN Aluminum bus bars with colour coded sleeves.
315OUTGOINGS
316- 63 A, TPN,10KA, MCB – 3 N.o.
317- 40 A, TPN,10KA, MCB – 3 N.o.
318- 32 A, TPN,10KA, MCB – 3 N.o.
319SECOND FLOOR PANEL
320INCOMER FROM MAIN LT PANEL
321125A TPN ,50KA, MCCB
322METERING & INDICATION
3231 sets of phase indicating lamps
3241 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
3251 Sets of Breaker ON-OFF-TRIP,
326BUS BAR as per SLD:-
3271 Sets of 150A, TPN Aluminum bus bars with colour coded sleeves.
328OUTGOINGS
329- 63 A, TPN,10KA, MCB – 2 N.o.
330- 40 A, TPN,10KA, MCB – 5 N.o.
331- 32 A, TPN,10KA, MCB – 3 N.o.
332THIRD FLOOR PANEL
333INCOMER FROM MAIN LT PANEL
334125A TPN ,50KA, MCCB
335METERING & INDICATION
3361 sets of phase indicating lamps
3371 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
3381 Sets of Breaker ON-OFF-TRIP,
339BUS BAR as per SLD:-
3401 Sets of 150A, TPN Aluminum bus bars with colour coded sleeves.
341OUTGOINGS
342- 63 A, TPN,10KA, MCB – 5 N.o.
343- 40 A, TPN,10KA, MCB – 2 N.o.
344- 32 A,DP,10KA, MCB – 2 N.o.
345MAIN UPS PANEL
346INCOMER FROM MAIN LT PANEL
3472*63A TPN ,50KA, MCCB
348METERING & INDICATION
3491 sets of phase indicating lamps
3501 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
3511 Sets of Breaker ON-OFF-TRIP,
352BUS BAR as per SLD:-
3531 Sets of 150A, TPN Aluminum bus bars with colour coded sleeves.
354OUTGOINGS
355- 63 A, TPN,10KA, MCB – 4 N.o.
356- 40 A, TPN,10KA, MCB – 10 N.o.
357- 40 A,DP,10KA, MCB – 4 N.o.
358EXTERNAL LIGHTING PILLAR- OUTDOOR TYPE -Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & outdoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or eqivalent as per approved make list and as direction by engneer in charge. PTTA Panel
359INCOMER FROM MAIN LT PANEL
3601*63A TPN ,10KA,MCCB
361METERING & INDICATION
3621 sets of phase indicating lamps
3631 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
3641 Sets of Breaker ON-OFF-TRIP,
365BUS BAR as per SLD:-
3661 Sets of 100A, TPN Aluminum bus bars with colour coded sleeves.
367OUTGOINGS as per SLD
36840 A,TP,10KA, Contactor -1 outgoings
369Timer
37010/16/25 A,SP,10KA, MCB,- 18outgoings
371NOTE:
372Any Item necessary for the completion of the systembut not mentioned in the BOQ shall be included by the supplier
373HT SUB STATION WORKS
374SITC of 11 KV, 630 Amp Outdoor type HT RMU. The RMU Should consist on one no of Load break switch (LBS) as incomer and one VCB as outgoing. The RMU should be type tested according to IEC 62271-100, 200 & 102, IACAFL, 21 kA for 1 sec, IP class 54, IP 67 for Tank. The rated voltage should be 12 kV, impulse withstand voltage of 75 kVp, Power frequency withstand voltage of 28 kV, rated short time current of 21 kA for 3 sec. The RMU should have SF6 gas insulation, robotic welding of gas tank. The RMU should be suitable for outdoor application. Themanufacturer should have service centre in the state of uttarakhand.
375Supply,Installation, testing & Commissioning of double pole structure suitable for 11 KV HT system as per CEA & UPCL norms & comprising of the following ,but not limited to it for completion of works . RSJ pole of 9 mtrs length of size 175 X 90 mm complete with suitable MS base plate welded at bottom base plate - 2 nos.MS channel of size 100 X 50 mm , length 4 mtrs (approx.)11 KV AB switch - 1 set , 11 KV Horn gap fuse unit - 1 set , 11 KV Lightning Arrestor , 11 KV Disc Insulator , 11 KV pin insulator 6 swg copper wire for jumperingSupply and erection of stay set complete with necessary foundation , excavation, and refilling of earth etc. as required. Concrete foundation for RJS poles burried upto a depth of 1830mm in ground in a pit of size 450 X 450 mm in CC 1:3:6 along with 200 mm copping above ground inclusive of earth work.Necessary Nut , Bolts, Clamps, operating handle for AB switch , clampingwelding etc. complete as required. Painting the RSJ poles complete with two coat of red oxide and two coats of GI enamel paints complete as required.
376Supply, installation, testing and commissioning ofoutdoor TYPE, OIL type transformer with copper winding having a continuous rating of 200 kVA, 11kV/415 +/- 1% V, 3 phase, 50 Hz, DY-11 vector group,The transformer shall have cable end box for indoor termination of HT cable on HT side and Cable Box for indoor terminationon LT side, complete in all respects including standard accessories. It is To be installed on Top of two pole structure with proper iron angle channel support as required.Compliance to BEE Standards AND BIS Standards (IS 1180). SERVOKON DISTRIBUTION TRANSFORMER
377Supply OF UNDERGROUNDHT CABLES
378Supply of HT (UE)AL XLPE Cable of size 3 C X 120 sq mm havells make
379Bullet cameras-PRIZOR 5MP
380Supply, installation, testing and commissioning of IP based, 4 MP, FULL HD WDR IR bullet CAMERA - 40 MTRS, colour indoor verifical dome camera, 3.6 MM FIXED LENS, 1/3 ", 4 Mega Pixel PS CMOS Image Sensor, WDR (120 dB), Day/ Night (ICR), IR Range of 40 Mtrs, IP67 and all ancillary equipments and all accessories.
381CP PLUS MAKE -
382Network Video Recorder
383Supply, Installation, Testing and Commisioning of 32 CHANNEL NETWORK VIDEO RECORDER, H.264/MJPEG dual codec decoding,Max 256 Mbps incoming bandwidth, HDMI/ VGA simulation video output, support 8 SATA HDD"s upto 32 TB, 1 ESATA up to 16 TB, supports multi brand network cameras.Each NVR shall have a storage capacity so as to recorda backup for 15 days at 4 CIF @ 25FPS.NVR should have system expandibility feature of at least 20% of current requirement, redundant fan and power supplies, outputs TCPIP network feature & server software monitor outputs. The NVR should be networkable via IP protocol & should be able to connect to a web based system for remote viewingvia web system. Vendor should submit the storage / HDD Calculation.
384CP PLUS MAKE -CCTV BUNDLE TOOLKIT
385Supply, Installation, Testing and commisioning of32" inches LCD monitor PRIZOR BASIC
386Design, supply, Installation, testing & commissioning of the following: 20 KVA/16KW UPS System, 415V, 50Hz. Input and 3Ph.+ N, 50Hz. Output, High performance industrial grade UPS, Advance IGBT rectifier and IGBT PWM Inverter fully digital signal processor (DSP) base with following key features – NUMAX ONLINE UPS
387Ø      Input Performance of UPS
388·    “ ZERO Impact on Source (SEB/DG)”
389·    IGBT PWM Rectifier
390·    Current harmonics - < 3% (iTHD)
391·    Input PF – 0.99
392·    Sequential Start up of UPS Systems (smooth change over to DG set)
393·    Wide voltage & frequency Tolerance (320V -480V & 45hz. To 55Hz.)
394·    Normal UPS operation during Input Phase sequence change
395Ø     Output Performance of UPS
396·    IGBT PWM Inverter, Short circuit proof.
397·    More output active power (rated @ 0.9 PF,20KVA = 16KW)
398·    Delta-Star Isolation Transformer
399·    Thermal over rated inverter design, more over load capacities, suitable for industrial loads. (110%, 125% & 150% - 60/10/1 Minute)
400·    Output Voltage 415V +/- 1% (Regulation)
401·    Out put Voltage wave form distortion at 100% non-linear loads (distorting Industrial loads)-< 3%(,1% at Linear Loads)
402·    Inbuilt Static bypass and manual maintenance bypass.
403·    On-line battery health monitoring (batteries always ready to work)
404·    Emergency Power Off (EPO), Energy back feed protection.
405·    Communication Options – UPS/ Power status can be monitored through user friendly software.
406·    Interface through – 2 Nos. RS232 Ports, SNMP, Potential Free contacts.
407Sealed Maintenance Free (SMF) for minimum 15 Minute back up with each 20KVA UPS at full load complete with powder quoted battery racks, interconnecting links.
408DG set
409Supply,Installation, testing & Commissioning of 200 KVA Silent DG set comprising of SuitableEngine coupled to 415V200 KVA Stamford make alternator both mounted on common Base frame with AMF PANEL and other standard accessories i.e. Fuel tank, Batteries with leads complete in all respects and as per details mentioned below: RISHABH POWER GENERATOR DG SET
410DETAILED SPECIFICATIONS
411DIESEL ENGINE:
41212 cylinder, 4 stroke cycle, Water cooled developing REQUIRED BHP at 1500 RPM under NTP conditions of BS:5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output of 200 KVA/ 160 KW at 0.8 power factor, 415 V at the alternator terminal.
413Other accessories of the engine would be as under:
414COOLING SYSTEM
415ù  Radiator/ HE Cooled
416ù  Engine mounted Water pump
417ù  Thermostats
418ù  Corrosion Inhibitor
419ù  Self contained piping
420ù  Outboard after coolers
421FUEL SYSTEM
422ù  PT fuel pump
423ù  Injectors
424ù  Fuel filters – Paper element type
425ù  Self contained piping
426LUBRICATING SYSTEM
427ù  Oil pump
428ù  Strainer
429ù  Lub oil cooler-Plate type
430ù  Oil filter – Paper element type
431ù  Bypass filter
432ù  Self contained piping
433AIR INTAKE SYSTEM
434ù  Dry type Paper Element filters
435ù  Air intake manifold with necessary connections
436ù  Turbo charged after cooled
437ù  Restriction Indicator
438EXHAUST SYSTEM
439ù  Exhaust manifold
440ù  Stainless steel flexible connections suitably optimized to reduce noise.
441ù  Silencers – Hospital Grade
442GOVERNING SYSTEM
443ù  Electronic Digital Governor
444STARTING SYSTEM
445ù  Starter, 24V,DC
446ù  Battery charging Alternator
447ù  With in-built Regulator
448SAFETY SYSTEM(Engine Protection – Trip)
449ù  Low lub oil pressure
450ù  High water temperature
451ù  Over speed
452ù  Low Coolant oil level (alarm)
453OTHER SYSTEM
454ù  Flywheel
455ù  Flywheel housing
456POWER COMMAND GENSET CONTROLS
457The controller should be a microprocessor based with following features.
458·         Digital AVR – Digital voltage regulation.
459·         Digital Electronic Governing and Smart Starting.
460·         Genset Monitoring – Monitors status of all critical engine & alternator functions
461·         Engine Metering
462·         AC Alternator Metering.
463·         AC Bus/ Utility Metering.
464·         Engine Protection.
465·         AC Alternator Protection.
466·         AC Utility Protection.
467·         Fault Codes & Description on HMI.
468·         Data Logging
469·         Configurable inputs and outputs.
470·         Modbus Interface (RS485RTU).
471·         AmpSentryprotection – for true alternator overcurrent protection. .
472·         Digital frequency synchronization & voltage matching.
473·         Isochronous load share.
474·         Digital Power Transfer Control.
475ALTERNATOR:
476Output- 200 KVA
477Power factor -0.8
478Rated Generating Voltage -415 Volts
479Voltage regulation +/- 0.5 % all load between no load to full load
480factor0.8 to unity
481Frequency 50 Hz
482Speed 1500 RPM
483Class of insulation - H type
484Winding connection -Star connection (all six leads will be brought out of stator frame)
485Overload capacity - 10% for one hour in any 12 hours of operationwithout exceeding temperature rise limits
486Bearings -Single bearing
487Enclosures - Drip proof & screen protected IP-23
488The alternator shall be of self-excited, self regulated, self ventilated in brushless design, provided with suitable automatic voltage regulator and shall conform to BS:2613 or BS : 5000 and shall give rated output at NTP conditions.
489ESSENTIAL ACCESSORIES:
490BASE FRAME:
491One no. MS Fabricated adequately machine Channel Common Base Frame with lifting facility, pre-drilled foundation holes suitable for permanent installation on concrete foundation for direct grouting or on anti-vibration mountings which will be suitable to receive the offered engine and alternator duly coupled through a flexible coupling.
492FUEL TANK:
493One no. Daily fuel tank of Standard capacity for each DG set made out of 2 mm thick MS sheet
494BATTERIES:
495For electrical control circuit of 24 volt DC, 2 Nos. batteries of 12 volts 160 Ah each with battery leads for electrical starting of each DG Set.
496SOUND ATTENUATED SYSTEM
497THICKNESS OF SHEET - 16-G
498High class sheet metal fabricated enclosure for reducing the noise level of DG set & also acts as a weather proof housing. Genset will be a integral part of acoustic enclosure and whole construction will be on multi-fold sheet channels & ISMC sections. Enclosure construction is fully bolted keeping in view the major service requirements all doors are provided with specially designed hinges and lockable handles, Battery, Fuel tank is housed inside the enclosure.
499ACOUSTIC MATERIALS
500Rock wool in the form of slabs of 100 mm thickness and 64 KG/Metric cube density (Specification of Rock wool conforms to IS 8183).
501Further to increase the life of Acoustic material resin coated fibre glass cloth is provided on exposed surface of Rock wool slabs and the panels are supported by perforated sheets.
502VENTILATION
503Acoustic enclosure is designed in such a way that there are no hot pockets around engine and it is provided with suitable designed engine radiator which does not allow the temperature to rise more than 70C above ambient temperature.
504To achieve optimal output and minimum sound level from the DG set, suitable openings with acoustic hoods are provide for increasing the inflow of air required for combustion & forced ventilation. Air intake system as per the recommendations and engine requirement are provided.
505ù   Acoustic hoods with noise splitters provided to block and reduce the sound leakage.
506ù   The sound control system designed to suppress the sound level to 75 db maximum at 1 metres distance in open free field environment as per ISO 8528 part 10.
507SILENCER
508Specially designed Critical Grade silencer is provided. Silencer & engine exhaust outlet, Connected with flexible SS below.
509VIBRATION ISOLATION
510To avoid transfer of vibration from genset to enclosure & surrounding specially designed vibration isolators to be used.
511Providing and fixingFire Extinguishers completewith all accessories aspermanufacturer"s specifications.
512a) Water CO2 nozzle type.(IS:15683), 2018 version-2
513b) Mechanical Foam (AFFF) complete as required capacity - 9 ltr , 15683- 2006 & ISO - 9001