|
| 1 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Hot rolled deformed bars |
| 4 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded20mm nominal size stone aggregate) finished with a floating coat ofneat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick |
| 6 | Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. |
| 7 | Brick work with modular bricks of class designation 75 in foundationand plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Brick work with FPS bricks of class designation 75 in superstructureabove plinth level upto two stories in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix 1:6 (1 cement : 6 fine/ coarse sand) |
| 10 | Kota stone slab flooring 25mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed withpigment to match the shade of the slab including rubbing andpolishing complete with base of cement mortar 1 : 4 (1 cement : 4coarse sand) :Area of each slab 900 to 2000 sqcm |
| 11 | Distempering with 1st quality acrylic washable distemper (readymixed) of approved manufacturer and of required shade and colour complete. as per manufacturer\"s specification.Two or more coats on new work. |
| 12 | Wiring of light point/ fan point/ exhaust fan point/ call bell point asper PWD specification for electrical Works with ISI marked 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III )vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.), round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pinceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISImarked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/cadmium plated iron screws 20 mm cup washers etc. all as perpre approved by Engineer in charge, making connections, testingetc. complete as required. For specification of copper Conductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories referChapter E - 04, E - 05 & E - 07 . For additional technical parametersof products/ work , refer Annexure \"A\" attached with this BSR Medium pointLong pointMedium point |
| 13 | Wiring of light point/ fan point/ exhaust fan point/ call bell point asper PWD specification for electrical Works with ISI marked 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III )vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.), round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pinceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISImarked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/cadmium plated iron screws 20 mm cup washers etc. all as perpre approved by Engineer in charge, making connections, testingetc. complete as required. For specification of copper Conductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories referChapter E - 04, E - 05 & E - 07 . For additional technical parametersof products/ work , refer Annexure \"A\" attached with this BSR Medium pointLong pointLong point |
| 14 | Less 10% |