| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FRLSH\" PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/Gloster) partly in 20mm size PVC rigid conduit \"FR\" (Precision /Polycab make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathedcopper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | 8 Mtr. |
| 3 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FRLSH\" PVC insulated & unsheathed single core stranded copper wire (Finolex/ Havells/ Polycab/ Gloster) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (LegrandMyrius/ Schneider Livia/ L&T Englaze) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish |
| 4 | On Board |
| 5 | Average run 4.5 mtr |
| 6 | Average run 7.5 mtr |
| 7 | Cutting channel of 31 mm x 31 mm /40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works(FOR power points, AC, SPNDB, TPNDB) |
| 8 | 13 mm dia 3 mm thick |
| 9 | 19 mm dia 3 mm thick |
| 10 | Supplying and fixing PVC Rigid Conduit \"FRLSH\" [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 11 | 20mm size |
| 12 | 25mm size |
| 13 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. |
| 14 | 150 mm x 100 mm x 65 mm |
| 15 | 175 mm x 100 mm x 65 mm |
| 16 | 200 mm x 150 mm x 65 mm |
| 17 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required |
| 18 | 150 mm x 100 mm x 65 mm |
| 19 | 175 mm x 100 mm x 65 mm |
| 20 | 200 mm x 150 mm x 65 mm |
| 21 | Supplying and Drawing 1.1 KV single core stranded \"FRLSH\" PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. (Finolex/ Havells/ Polycab/ Gloster) |
| 22 | 2 x 22/0.3 (1.5 sqmm) |
| 23 | 3 x 22/0.3 (1.5 sqmm) |
| 24 | 2x(2.5 sqmm)+1x(1.5 sqmm)[ for multiple plug socket ] |
| 25 | 2x (6 sqmm) + 1x (4 sqmm)(SPN DB) |
| 26 | Distribution wiring in 1.1 KV single core stranded \"FRLSH\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" HMS (Precision make) incl. necy. fittings as required.[for 3ph AC out side connection] |
| 27 | 4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC. (For VTPN to AC). |
| 28 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 29 | 2.5sqmm |
| 30 | 4 sqmm |
| 31 | 6 sqmm |
| 32 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. |
| 33 | 2+10 Way[ Legrand /Crabtree/ABB] |
| 34 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(For distribution of HTPNDB, 3 phase AC) |
| 35 | 8Way ( Up to 160 A ) [ Legrand /Siemens/ABB] |
| 36 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment |
| 37 | 8Way VTPN |
| 38 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] |
| 39 | 63 A DP |
| 40 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] |
| 41 | 6-32 SP |
| 42 | 6-32 TP |
| 43 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs/ MCCB enclosure including necessary connection as per GS [ Make - Legrand ]. |
| 44 | 100 A FP (for VTPN) |
| 45 | Supply of4 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Gloster/Polycab] |
| 46 | 4 Core 70 Sq. mm[ for connection ofVTPN from building panel] |
| 47 | Laying of cable 4 core 70 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. |
| 48 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire as per GS |
| 49 | 4 Core70 sqmm |
| 50 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 51 | 4 Core70 sqmm |
| 52 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 53 | 4 Core 70 Sq. mm |
| 54 | Supply & Fixing of perforated GI cable tray ( 18SWG) with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender withangle iron support as per GS. |
| 55 | 150x50x1.25mm |
| 56 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (LegrandMyrius/ Schneider Livia/ L&T Englaze), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. (For computer board from SPNDB) |
| 57 | Supply & Fixing 240 V, 1 no. 6 A, 3 pin Modular type plug socket with 1 no. 6A Modular type switch (Brand approved by EIC) and 1 no 16A, 5 pin Modular type plug socket with 1 no. 16A Modular type switch,without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. (for multipurpose use from PDB) |
| 58 | Supplying & Fixing GI Modular Switch Board (LegrandMyrius/ Schneider Livia/ L&T Englaze) of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 2 Module [ 2-a/E-17 ] (for 3phase AC Control) |
| 59 | Supply & Fixing 240 V 6 A Modular type switch (Legrand Myrius/ Schneider Livia/ L&T Englaze) on existing GI Modular type switch board having top cover plate and making necessary connections as required. [ For AC on/off] |
| 60 | Supply & Fixing 240 VModular type Indicator lamp (Legrand Myrius/ Schneider Livia/ L&T Englaze) on existing GI Modular type switch board having top cover plate and making necessary connections as required.[For AC on/off status indication] |
| 61 | Fixing only full 2ft x2ftGlow light fitting on false ceiling after cutting the false ceiling incl. necessary connection and mending goods the damages to original finish. [NS] |
| 62 | Fixing only Recessed type circular (Dia up to 8 inch) LED down light after cutting the false ceiling incl. necessary connection as required. [NS] |
| 63 | Supply & Delivery of LED Smart Glow High eficiency light fittings( Make-Philips, Cat. No.RC383B LED36S-6500 PSU OD WH PIR / Crompton/ wipro having similar specification ). |
| 64 | Supply & Delivery of LED Full Glow High eficiency light fittings ( Make-Philips, Cat. No.RC380B LED36S-6500G5 L60W60 PSU OD SG / Crompton/ wipro having similar specification ). |
| 65 | Supply of1200Lm output recess mounted LED down light ( Make-Philips, DN193B LED12S-6500 PSU WH S2/ Crompton/ wipro having similar specification ) |
| 66 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 67 | 23 cm (9\") |
| 68 | 30 cm (12\") |
| 69 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x62 mm long) |
| 70 | 9\"/12\" |
| 71 | Supply of Heavy Duty Exhaustfanscomplete with all accessories having the following Model / Cat No.( Make -EPC Electrical Pvt. Ltd. ) |
| 72 | 9\"( 230mm ) Speed 1370 RPM |
| 73 | 12\"( 300mm ) Speed 920 RPM |
| 74 | S& Fixingonly 16\" (400mm) full metal body wallBracket Fan complete with all accessoriesto be fixed on wall inclu. Making necesy. Connection as per direction of the EIC (Make - E.P.C.Electrical Pvt. Ltd., Heavy Duty). |
| 75 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. |
| 76 | Supplying & Fixing of PVC water proof type Loopbox (Make-Sintex GSJB2520 /Hensel)of size [250X200X100]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC |
| 77 | S.I.T.C. of Crono time switch[Make-L&T Cat no 67DDT0 ] |
| 78 | S/F of 3 pole contactors ABB make AX32-30-10 with 240 V operating coil. |
| 79 | Supplying and fixing 240 V, SP MCB on din rail of existing DBs and necessary connection as per GS [Make-Legrand ] |
| 80 | S&F of 12V, 29 A-348W metal SMPS on existing glow sign board.(Make: Meanwell LRS-350-12) |
| 81 | Airconditioning Work: S&D of minimum 13KW nominal cooling capacityceiling suspended [ concealed]Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRY16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F). |
| 82 | Installation testing & commissioning of above AC machines at Research Lab by fixing the indoor with10mm full threaded suspender bolt with double nut & spring washer.Out door unit will be fixed on roof byMS chair made by 50mmX50mmX6mm equal angel & minmum hight of 450mm from floor level & grouting the same, painting as per direction of EIC & carrying the outdoor to the roof of building. And mending good the damages of walls by CC & sand cement plaster. as per instruction of EIC |
| 83 | Supply & Fixing 50x50x6 mm MS Angle with suitable no of holes to be welded on existing roof trass.As per instruction of EIC |
| 84 | Supply & Laying of Refrigerent Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistance nitrile rubber insulationwith double insulating wrapping tape to avoid dripping of condensate water:- |
| 85 | Suction Line 15.88mm dia, min. thickness 0.99mm with 9mm thick nitrile insulation. (Make : Rajco / Royku). |
| 86 | Suction Line 19.05mm dia, min. thickness 0.99mm with 9mm thick nitrile insulation. (Make : Rajco / Royku). |
| 87 | Discharge Line 9.5mm dia, min. thickness 0.8mm with 9mm thick nitrile insulation. (Make : Rajco / Royku). |
| 88 | Wrapping the copper pipe with insulation & electric cable by S/F 26SWG Aluminimum sheet to make it weather & vermin proff. |
| 89 | Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5sq mm coppercable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells) |
| 90 | Supply & laying drain Water piping work with 25 mm dia Schedule 40 pvc pipe/HDPE Pipe (Reputed make) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. thick nitrile rubber tube insulation. |
| 91 | S&F flexible canvas connection for indoor to duct/ air terminal for13KW indoor |
| 92 | SITC ofPowder Coated Al. Grill without VCD suitable size(Make:Systemair / Primier) |
| 93 | S & providingdrop ceiling to cover the indoor units & supply air duct including the cost of3mm thick ACP sheet as per manufacturer\"s specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (2mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (2mm thick) and silicon sealent complete in all respect including making trap door arrangement as per direction of EIC. (Make:Aludecor/Armstrong) |
| 94 | Defect Liabibility Period 1 (One) year |