Tender For Extension Of Existing Including Complete Earthwork ( Excavation, Backfilling Etc.) For The Entire Buried Piping For Hvw Spray System Fire Fighting System And Hydrant System, Valve Pits And Pipe Supports For Buried, Entrenched And Over Grou, Chittorgarh-Rajasthan

Rajasthan Rajya Vidyut Prasaran Nigam Ltd-RRVPN has published Tender For Extension Of Existing Including Complete Earthwork ( Excavation, Backfilling Etc.) For The Entire Buried Piping For Hvw Spray System Fire Fighting System And Hydrant System, Valve Pits And Pipe Supports For Buried, Entrenched And Over Grou. Submission Date for this Tender is 07-08-2023. Fire Fighting Consumable Tenders in Chittorgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38860191
Tender For Extension Of Existing Including Complete Earthwork ( Excavation, Backfilling Etc.) For The Entire Buried Piping For Hvw Spray System Fire Fighting System And Hydrant System, Valve Pits And Pipe Supports For Buried, Entrenched And Over Grou
Open Tender
Indian
Rajasthan
Chittorgarh
07-08-2023

Tender Details

Extension Of Existing Including Complete Earthwork ( Excavation, Backfilling Etc.) For The Entire Buried Piping For Hvw Spray System Fire Fighting System And Hydrant System, Valve Pits And Pipe Supports For Buried, Entrenched And Over Ground Piping

Key Value

Document Fees
INR 2950 /-
EMD
INR 54930.0 /-
Tender Value
INR 27.46 Lakhs /-

BOQ Items

Name of Work:Extension of existing including complete earthwork (i.e. excavation, backfilling etc.) for the entire buried piping for HVW spray system Fire Fighting system & Hydrant system, valve pits and pipe supports for buried, entrenched and over ground piping along with supply of material required for the newly installed 400/220/33 kV 315 MVA Auto Power transformer at 400 kV GSS, Chittorgarh
Sl. No. Item Description
1FIRE FIGHTING SYSTEM ( AS PER TECHNICAL SPECIFICATION)
2Mulsifyre System
3M.S. pipes suitable for overground and under ground as per relevant BIS & Mulsifyre Strainer
4Mulsifyre Strainer
5G.I. piping with fittings
6(a) G.I. pipe 25 mm dia
7(b) Fittings for 25 mm dia pipe
8(a)250 mm dia pipe.
9(b)Fittings for 250 mm dia pipe
10(c)200 mm dia pipe.
11(d) Fitting for 200 mm diapipe
12(e) 150 mm dia pipe.
13(f) Fittings for 150 mm dia pipe
14(g) 100 mm diapipe.
15(h) Fittings for 100 mm dia pipe.
16Set of Deluge valve (including solenoid valve) stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection
17(a) Mulsifyre projectors
18(b) Quartzoid bulb Detectors
19(c) 150 mm dia Deluge valve
20(d) 250 mm dia Drain valve
21(e) 150 mm dia GI pipe
22(f) 100 mm dia GI Pipe
23(g) 80 mm dia GI Pipe
24(h) 50 mm dia GI Pipe
25(i) Alarm Motor & Gonge
26(j) D.A. Switches & local control Panel
27(k) 150 mm dia Strainer
28(l) Elbow & Tee & Socket & Reducer & Bend & Union & Flange ofall required sizes
29(m) NRV & Sizes
30(n) Pressure Meter & Pressure Switch, Solenoid valve & sizes
31Power and control cable (required for deluge local control panel and integrate alarm in 32 sec. Annunciation panelin FF room , LT Room and in scada. (alsthom) & earthing
32Alarm in32 section Annunciation panel for complete installation both area (firefighting room & LT Room) with integration in existing SCADA (ALSTOM) System.
33Any other specified item for completion of Musifyre system ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
34Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
35Hydrant System
36Gate valve & size
37Ring main with pipes and fittings
38150mm dia CITJ pipe / MS pipe
39Fittings of 150mm dia pipe
40100 mm dia CITJ pipe / MS pipe
41Fittings of 100mm dia pipe
42Elbow , Tee & Socket, Reducer , Bend & Union & Flange ofall required sizes
43Hydrant Female Oblique type with stand pipe
44Single headed stand pipe
45Double Headed stand pipe
46Gun metal landing valve
47150mm dia Isolator valves
4863mm dia 15M long hose pipe
49Hose cabinets
50Branch pipe & jets
51Fog type Nozzle
52Any other specified item for completion of Hydrant system ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
53Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
54HAND APPLIANCES
55foam typeportable fire extingusher of 9 litre capacity complete with fill
56Dry chemical powder type portable fire extingusher of 5 Kg. capacity complete with fill
57High pressure foam typeportable fire extinguisher of 50 Ltr capacity complete with fill
58Carbon di-oxide type portable fire extinguisher of 9 Kg. capacity complete with fill.
59Fire Bucket with Stand
60NOTE :- Quantities of each item shall be finalized during approval ofdetailed engineering. Capacity ofmay vary as per IS.
61SPARES FOR MULSIFYRE / HYDRANTSYSTEM
62Fog Nozzles
63Quartzoil Detectors
64Level Switch
65Pressure Switch
66Hydrant Valve