Tender For Provision Of Electric Operated Boom Barrier, Flag Mast, 16 Amps Switch And Sockets Alongwith Certain Misc Works And 10 Nos Air Conditioners At Otm Complexes At Cg Land, Panvel, panvel-Maharashtra

Military Engineer Services-MES has published Tender For Provision Of Electric Operated Boom Barrier, Flag Mast, 16 Amps Switch And Sockets Alongwith Certain Misc Works And 10 Nos Air Conditioners At Otm Complexes At Cg Land, Panvel. Submission Date for this Tender is 17-08-2023. Gate Barrier Systems Tenders in panvel Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

38839610
Tender For Provision Of Electric Operated Boom Barrier, Flag Mast, 16 Amps Switch And Sockets Alongwith Certain Misc Works And 10 Nos Air Conditioners At Otm Complexes At Cg Land, Panvel
Open Tender
Indian
Maharashtra
panvel
17-08-2023

Tender Details

Provision Of Electric Operated Boom Barrier, Flag Mast, 16 Amps Switch And Sockets Alongwith Certain Misc Works And 10 Nos Air Conditioners At Otm Complexes At Cg Land, Panvel

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work: PROVISION OF ELECTRIC OPERATED BOOM BARRIER, FLAG MAST, 16 AMPS SWITCH AND SOCKETS ALONGWITH CERTAIN MISC WORKSAND 10 NOS AIR CONDITIONERS AT OTM COMPLEXES AT CG LAND, PANVEL
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes, laying of pipes and cables etc not exceeding 10 sqm on plan and getting out in hard/dense soil all as specifed and as directed.
2Surface dressing n exc 15 cm deep in hard/dense soil all as specifed and as directed.
3Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specifed and as directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. all as specifed and as directed.
5M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass complete all as specified and as directed.
6M&L 75 mm thick cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate as sub base complete all as specified and as directed.
7M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment over and including 50mm thick crushed stone sand cushioning all as specified and as directed.
8M&L for Pre-cast cement concrete block masonry with solid blocks, type C1 (1:3:6) (using 20mm graded stone aggreaget) exc. 10cm in width and setting in mortar (1:4), complete complete all as specified and directed.
9M&L for rendering 15 mm thick CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified ans as directed.
10M&L for preparation of new plastered surface of wall, chajja, parapet etc and applying two coats of weather proof acrylic emulsion paint over a coat of acrylic primer etc complete all as specified and as directed.
11M & L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and as directed.
12M & L for vitrified coloured tiles of 9-10 mm thick (square / rectangular) area of each tiles not exc 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured to match coloured tiles over 15 mm screed bedding in cement mortar 1:4 complete all as specified and as directed.
13All as per item 12 above but on vertical surfacessuch as skirting / dadosincluding 15 mm thick rendering in CM (1:4) as in backing coat complete all as specified and directed. complete all as specified and as directed.
14M & L for 6 meter stainless steel Flag Mast to be erected on stainless steel plate with SS nuts and bolts in the center of the mast base complete all as specified and as directed.
15Supplying, installation,commissioning and testing automatic boom barrier with boom length 4 meters suitable to operate on 240 V , 50 Hz AC supply, Dual speed for quick opeaning and closing of the barrier with safe landing and adjustable opening time 4 to 10 sec with single touch push button and remote control with electronic control panel complete in all respects including control wire all as required of approved makeall as required at site or directed by manufacturure or Engineer-in-charge.
16Supply and laying or fixing or passing through pipe 1100 Volts grade heavy duty cable with PVC insulated multistranded aluminium conductor of 25 sqmm 2 core , armoured cable with galvanised steel strip or wire all as required and directed.Note- rate of cable includes earthwork, sand coushioning, brick or PCC covering, light Grade GI tubing where necessary, testing etc in quoted rates.
17M&L for sheet metal enclosure MCB distribution board double door with IP-42 protection without bus bar one neutral link 2 way 240 volts with and including MCB SPN 240 volts 32 Amps rating all as specified and as directed.
18Supply and fix, installation and commissioning of voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designated for input variation between 300 V to 480 V with output voltage stabilizer at 415 with accuracy +/- 2.5 % and speed of correction 8 Volts per second and of capacity 500 KVA including all civil works such as plinth protection, fencing if necessary and all PCC works as required by OEM.
19Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6.3 mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron strip of size 32x6 mmfrom earth electrodeto test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value, completeall as specified and directed.
20Supply, laying and testing cable XLPE insulated, screened, PVC beded galvanised steel strip or wire armoured electric power cable heavy duty 1100 Volts grade with stranded aluminium conductor of size 400 sqmm 3.5 core fixed on wall/ laid in trenchesin complete manner complete all as specified and directed .Note- Rate of cable includes earthwork, sand coushioning, brick or PCC covering, light Grade GI tubing where necessary, testing etc in quoted rates.
21S & F cable tray 250 mm wide x 50 mm deep, hot dip galvanised with standard slot pattern manufactured from cold rolled sheet min thickness 2 mm , perforated type including provision of fixing arrangement, all bend and fittings, nuts and bolts, cable tray cover etc for proper securing to beams or suspended from ceiling, complete all as specified and directed.
22S & F cable tray 150 mm wide x 50 mm deep , hot dip galvanised with standard slot pattern manufactured from cold rolled sheet min thickness 2 mm , perforated type including provision of fixing arrangement, all bend and fittings, nuts and boalts, cable tray cover etc for proper securing to beams or suspended from ceiling, complete all as specified and directed.
23M&L submain wiring with 2.5 sqmm (nominal dia ) PVC insulated and PVC unsheathed FRLSH cable stranded copper conductor including 1.5 sqmm earth wire form Submain distribution box to switch board with and including casing and caping complete in all manner all as specified by Engineer-in-Charge.Note- Removal and refixing of false ceiling and drilling holes in wallsis deemed to be included in above quoted rates. Make for copper cable -Plolycab, KIE, finolex, Universal cables.Make for casing capping -Pressfit or equivalent
24M & L for circuit/ submain wiring alongwith earthwire with the sizes of 2x4.0 sqmm and 1x2.5 sqmm earthwire for submain Distribution box to switch board with and including casing cappping complete in all manner all as specified by Engineer-in-Charge. Note- Removal and refixing of false ceiling and drilling holes in walls if any is deemed to be included in above quoted rates. Make for copper cable -Plolycab, KIE, finolex ,Universal cables.Make for casing capping -Pressfit or equivalent
25M & L for circuit/ submain wiring alongwith earthwire with the sizes of 2x6.0 sqmm and 1x4.0 sqmm earthwire for submain Distribution box to switch board with and including casing cappping complete in all manner all as specified by engineer-in-charge. Note- Removal and refixing of false ceiling and drilling holes in walls if any is deemed to be included in above quoted rates. Make for copper cable -Plolycab, KIE, finolex ,Universal cables.Make for casing capping -Pressfit or equivalent
26M & L for circuit/ submain wiring alongwith earthwire with the sizes of 2x6.0 sqmm and 1x4.0 sqmm earthwire for submain Distribution box to switch board with and includingPVC conduit fixed on wall with saddlescomplete in all manner all as specified by engineer-in-charge. Note- Removal and refixing of false ceiling and drilling holes in walls if any is deemed to be included in above quoted rates. Make for copper cable -Plolycab, KIE, finolex ,Universal cables.
27S & Fmodular switch 15 amps ,ISI marked, flush type, multipurpose1way, 1module, completeall as specified and directed.
28S & Fmodular socket 6/15 Amps ,2/3 pin combined 2 module ISI marked, flush type, completeall as specified and directed.
29Supply and fix in repairs MCB distribution board SPN 8 way 240 volts, double door withIP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete all as specified and as directed.Make:-Standard/ Legrand/Schneider/Havells/Siemens
30Supply and fix 63 Amp rating , 240 V ,10 KA , "C" curve MCB SPN 63 Amps in the MCB DB complete with connection testing and commissioning etc all as specified and directed by engineer-in-charge.
31Supply and fix 32 Amp rating , 240 V ,10 KA , "C" curve MCB SPN 32 Amps in the MCB DB complete with connection testing and commissioning etc all as specified and directed by engineer-in-charge.
32M&L for point wiring complete with proper colour coding using 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking inand including PVC cassing capping , ISI marked , with all accessories concealed in wall/ceiling/floor/roof etc with modular metal flush boxes with modular white cover plate and frame of module suitable for mounting switches, sockets, fan regulators including 1.5 Sqmm PVC insulated FRLS unsheathed1100 Volts multistranded copper conductor green colour conforming to IS:694:1990with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed.Note:- all circuit wiring from MCB DB to switch board shall be of 3x2.5 sqmm for (P+N+E) .The difference in cost deemed to be inclusive in point wiring.
33S&F in repair ceiling rose, 3 phase/PVC/polycarbonate isolated body, ISI marked , complete all as specified and directed.
34S & Fmodularswitch, single pole, ISI marked, one way 6 Amps 1 module 250 volts , completeall as specified and directed.
35Supply and fixing round shape 15 watt, 220 Volts AC recess type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
36Supply and fixing low density 32 mm PVC pipe of pressure rating 6 kg/ Sqcm to walls /trenches/ceiling or floors for inclusion of split airconditioner water pipes in to it and including all fittings, bends, knees etcfor provision of connecting ofwater AC ODU pipes to PVC pipe with fixing arrangement and connecting the pipe such that all water should reach to ground floor earthing area complete all as specified and directed.
37Supply and install testing and commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height,intial filling of refrigerant gas inculding making round hole on existing wall for taking up refrigerant tubing, drain pipe, cables etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed. .Make :- VOLTAS/BLUESTAR/LG/GODREJ/DaikinNote:- AC"s to be installed at various heights and locations at G+6 building.
38Supply and fixVoltage stabilizer for automatic operation, single phase naturally air cooled indoor type , Wall mounted type & designed for input variation between 130 V to 300 V with output voltage stabilized at230 V with accuracy of ± 2.5%and of capacity 3800 VA suitable for 2 Ton AC.Make- V Guard VGB 500 or equivalent.
39Supply and fix of metal clad plug and socket with MCB SP 6 to 32 Amps, 10 KA "B" series, 415 V
40Material and labour for submain wiring along with earth wire using 2x 6.0 sq mm (colour coading) + 1x 4 sq mm earth wire (green colour) of single core PVC insulated multistrand copper conductor 1100 Volts grade FRLS type in and including PVC casing capping of size not less than 25 mm dia (ISI marked) with all accessories suchas bend, junction boxes, short pipes of suitable size complete all as specified. Note: Two run of 6.0 sqmm cable and one run of 4.0 sqmm cable and one run of PVC casing capping will be measured as one unit.
41Supply and fix factory fabricated mild steel stand suitable for installation of out door unit of split type air conditioner fixing arrangement with anchoring bolts on wall surface at suitable height as per site condition.