Tender For Special Repair Against Ber Ac Plant Under Ge (A) Jaisalmer (Job No 01/Srw/Bldg/Adgsi/12 Rapid/Jaisalmer/2022-23), jaisalmer-Rajasthan

Military Engineer Services-MES has published Tender For Special Repair Against Ber Ac Plant Under Ge (A) Jaisalmer (Job No 01/Srw/Bldg/Adgsi/12 Rapid/Jaisalmer/2022-23). Submission Date for this Tender is 23-08-2023. HVAC Tenders in jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38799160
Corrigendum : Tender For Special Repair Against Ber Ac Plant Under Ge (A) Jaisalmer (Job No 01/Srw/Bldg/Adgsi/12 Rapid/Jaisalmer/2022-23)
Open Tender
Indian
Rajasthan
jaisalmer
23-08-2023

Tender Details

Special Repair Against Ber Ac Plant Under Ge (A) Jaisalmer (Job No 01/Srw/Bldg/Adgsi/12 Rapid/Jaisalmer/2022-23)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-08-2023
2 17-Aug-2023 Corrigendum No 01 Other 23-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 55500.0 /-
Tender Value
INR 27.51 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR AGAINST BER AC PLANT UNDER GE (A) JAISALMER (JOB NO 01/SRW/BLDG/ADGSI/12 RAPID/JAISALMER/2022-23)
Sl. No. Item Description
1Supply, install, test and commissioning of water cooled package type air conditioning plant not less than 2X14TR (1x14TR will be working tonnage and 1X14TR will be standby) Capacity complete to achieve the inside temprature 22ºC± 2ºC with RH of 55 ± 5% with following equipment and accessories:-
2(a) Water cooled package comprising of scroll compressors with capacity control suitable for not less than 2X 14 TR (1X14 TR working , 1X14 TR standby) capacity water cooled condensers having independent circuit for each compressor and chillers, with inbuilt control panel having microprocessor conttrol for operation of compressor, condensor, bolwer motor having features of automatic selection of compressor, run time equalisation , memory back up, auto restart after power failure, built in time delay, fuzzy logic, fault diagnostics including all safety controls complete with suitable capacity contactors duly prewired and inter connected -1 unit. (b) Supply, install, testing & commissioning of energy efficient monoblock centrifugal pumpset with GM impeller capable of discharging not less than 6 lps at 24 mt head drivenwith electric motor of suitable capacity, 3 ph, 415, 2900RPM for water circulation of condensors including pressure gauge at both suction and discharge sie of pumps, strainer at suction side - 02 Nos (100% capacity including one standby) (c) Suuply, install , test & commissioning of split pumpset capable of discharging 20 lps at 30mt head drivenwith electric motor of suitable capacity (appr 7.5HP), 3ph,415V,2900 RPM for chiller water circulation including butter fly valves, flanged type, non return valve of suitable capacity, pressure gauges at both suction and discharge side of pumps, Y type strainer at suction side - 1 No for each pump - 02 Nos (1 working +1 standby)
3(d) Double skin construction air hanling unit (AHU) suitable for chilled water system made out of extruded aluminium structural frame/ aluminium conrners and intermediate connecting pieces and panels of 0.5mm galvansied steel sheet on both sides with 25mm thick PUF of density (38+2)kg/cum injected panels having scratch free plastisolcoating on outer side. The fan section should be mounted on anti vibratio spring isolators and free from main structure.Thefan should be back ward curved centrifygal fan with air discharge upblast, belt driven with TEFC induction motor of suitable capacity.The coil section consist of 6 row deep coil with min 12 fins/inch duly coated with hydrolic coat.The filter section consist of prefilter with 10micron 90% efficiency.The other accessories are view port, limitswitch, stainless steel drain pan, volume control damper, mixing chamber for 28TR plant with min air flow of not less than 8000/11000 CFM at 40 mm TSP with energy efficient motor of suitable capacity and specified makes. AHU shall be provided UVC emitters & fixtures in sufficient quality so as to provide equal distribution of UVC energy on the coil and in the drain pan all as specified - 1 No. (e) Pan type humidifier comprising of stainless steel pan with 3 KW heater, wiring,water piping GI pipe medium grade 15mm. (f) Strip type heater bank not less than 6KW (in two banks of 3 KW each) with necessery copper conductor wiring for banking complete - 1 set. (g) Humidistats and thermostats in AHU room
4(h) Electrical panel cubicle type, fabricated by CPRI approved manufacturer, floormounted, indoor type made out of 2mm thick CRCA sheet for the intermal compatments along with doors with 1.6 mm thick sheet, dust and vermin proof duly powdercoated with copper bus bars 200A capacity-1 No, set of three LED indication lamps with base and PCC foundation included comprising of the following :- (i) MCCB 4 pole 160A, 25 KA breaking capacity - 1 No (incoming) (ii) MCCB 4 pole 63A, 10 KA braking capacity - 3 No (for chiller units and for one AHU) (iii) MCB 3 pole upto 32A, 10, KA breaking capacity- 06 Nos.(for pumps 4 Nos, Strip type heaters- 01 No& spare -01) (iv) MCB SPN 16A, 10KA breaking capacity - 1 No (for UVC emitter) (v) Digital ammeter with built-in selector switch and set of CTs - 10 No (vi) Digital voltmeter with builtin selector switch - 01 No (vii) Fuse base with HRC fuses- 01 lot for meters and lamps (viii) DOL starter of suitable capacity comprising of main contractor with OLP, star contactor with electronic timer, aixillary contractor for auto start with relay complete wiring with multi stranded copper conductor 4 Nos (for chiller and condenser pump motors) Internal wiring with multi stranded copper conductor PVC insulated single core 2.5 sqmm complete (ix) Star delta starter of suitable capacity comprising of main contactor with OLP, star contractor, delta contractor with electrinic timer, auxillary contractor for auto start with relay complete wiring with multi stranded copper conductor-1 no (for AHU BLOWER MOTOR) (x) Single phasing preventors with phase reversal protection working on negative srquence current-1 Nos for AHU motor.
5(j) Electrical panel cubicle type fabricated by CPRI approved manufacturer, floomounted, indoor type made out of 2mm thick CRCA sheet and the internal compatments along with doors with 1.6mm thick sheet, dust and vermin proof duly powdercoated with copper bus bars 200 A capacity, set of three LED indication lamps with base and PCC foundation including comprising of the following :- (i) MCCB 4 pole 160A, 25 KA braking capacity -1 No (incoming) (ii) MCB 3 pole upto 32A, 10, KA breaking capacity- 06 Nos (3 Nos for strip type heater, 01 for humidifier, 01 for lightingand one spare). (iii) Power contactor 3 pole, 16 A, AC1 rating with 415 V coil - 2 Nos. (iv) Digital ammeter with buil-in selector switch and set of CTs - 1 No. (v) Digital ammeter with built-in selector switch and set of CTs - 2 No ( for package units) (vi) Digital voltmeter with builtin selector switch - 01 No (vii) Fuse base with HRC fuses- 01 lot for meters and lamps (viii) Internal wiring with multi stranded copper conductor PVC insulated single core 2.5 sqmm complete
6(k) Water flow (Pressure) switch with necessary connection to condensor pipe all as directed. (l) Refrigeration control wiring with copper conductor, PVC insulated, unsheathed, multistranded. 1100V grade, single core of size 1.5 sqmm draw in and including PVC conduit of suitable size for interlocking arrangement as per standard practice with thermostat, humidstat, three way valve, heater bank, etc, all as directed for each AHU. (m) Non chemical type on line scale preventor suitable for fixing on the common header of condenser of suitable dia pipe, working on principle of magnetic fields all as directed. (n) Accoustic insulation with 19mm thick nitrile rubberand finished with RP tissue paper and 28mm gauge aluminium preforated sheet upto 5 Mtr from AHU Canvas connection all as specified and directed. (o) Expansion water tank, double layered rotational moulded polethelene 100 lts capacity duly insulated with fibre glass of 75mm thick wrapped around the tank, providing hassoin cloth above it and cladding with aluminium sheet of 24 gauge complete including MS ERW pipe line connection 25mm dia duly insulated with glasswool 25mm thick and overall cladding with 28G aluminium sheet all as directed.Density of fibre glass be 48 kg/m3.
7Notes for item No 1.00 :-1. The following works are deemed to be included in the rates of above mentioned item. (a) Civil work such as modification to existing foundation or provision of new foundation in PCC 1:3:6, making good the disturbed surfaces etc. (b) Perforated GI sheet cable tray 300mm width fixed on angle iron supports grouted in wall for carrying all cables. (c) pressure gauge, thermo meters on suction and discharge sides at pumps. (d) Miscelleneous items required for entire completion of work such as flexible canvass connection atunit, smallcontrol valves as directed and asper stanard engineering practice. 2. The following items are measured and paid seperatly (a) Main cables for heaters, package units, AHU, pantype humidifier, pumps, condensor. (b) MS pipes, butter fly valves for condensor water and chill water. (c) Any modification required for existing ducting and replacement of defective. (d) Fire dampers. (e) Earthinh and earth continuity conductor (f) Dismantling of existing AC plant. (g) High efficiency 5 micron filters. (h) Girlls/Diffusers
8Supply and lay MS Pipes heavy grade with all fittings laid on supports including painting with one coat of red oxide primer and two coats of synyhetic enamelpaint all as specifeid and directed of the following sizes:-
950 mm bore
1040 mm bore
11All as per item No 2.00 hereinbefore but including pipe insulatin with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI Sheet complete offairly finished laid in trenches/fixed to walls when laid exposed.
1250 mm bore
1340 mm bore
14Note for item No 3.00:- Exposed pipe shall be painted with 02 coats of cement based paint of approved colour all as directed and the cost of the same deemed to be included in the quoted rate.
15All as per above item 2.00 hereinbefore but steel tubing shall be painted with one coat of red oxided primer only but including pipe insulation with fibre glas preformed pipe section with factory laiminated aluminium foil to mm thick of density 80 Kg/m3 with suports from walls. ceiling inside the rooms when laid indoor size 40/50 mm bore complete all as specified and directed.
16S&F Butterfly valve both end flanged and drilled with Disc of DI with epoxy coating or CI with nylon coating and seal with neoprene rubber/EPDM of class PN-16 confirmming to IS and ISI marked of size 40/50 mm bore complete all as specified and directed.
17S&F of non return valves of sizes 40/ 50mm dia complete all as specified and directed.
18S&F of Y stainer of 50 mm dia complete all as specified and directed.
19S&F of balancing valves of sizes 40/50 mm dia complete all as specified and directed.
20S&F of 3 way motor rised valves with actuator ofsizes 40/50mm dia complete all as specified and directed.
21S&F of rubber expansion joint ofdiasizes 40/50 mm complete all as specified and directed.
22Supply, assembly and erection of GI sheet with C & SS rectangular / square duct made out of L shaped hollow profile, duty factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 24 guage sheet including 25 mm x 4 mm angle iron supports 10 mm dia rods, anchor fastners etc fittings joints for plenum and joining exsting ducting all as per IS specification complete all as specified and directed.
23S&F of GI duct dampers with extruded aluminium sections for volume control complete all as specified and directed.
24M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier size 50mm and inner side thermol insulation with 13mm thick nitrile rubberwith aluminium foil complete of insulation as specified and including the following:-
25(a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreigen materials,taking special care so that all duct joints are sealed against any leakage. (b) M&L for appling rubber based adhesive CPRX compound. (c) M & L for sealing of all logitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50mm at maximum intervals of 1.2 mtr.
26S&F of fire damper made out of GI section and 16 SWG GI sheet with UL stamped fusible link duly operated with stainless steel spring and tob e provided in main supply dict interlocked with AHU motor to cut off in case of fire complete all as specified and directed.
27S&F supply air slot lineat grills made out of powser coated extruded aluminium sections with volume control adjustment and having 6 slots complete all as specified and directed.
28Supply, laying and testing of earthing complete with galvanisedearth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level connected to galvanised earth strip of size 32 x 6 mm by means of bolts,, nuts washers of GI all as shoen in electrical plate no 5 of SR part VI connected to earth test point including test point complete incoluding earth work excavation in any tyype of soil PCC (1:3:6) type ci bed and chamber RCC (1:2:4) type B1 cover 40 mm thick including 6 mm dia reinforcement and funnel watering pipe etc complete all as specified and directed.
29S&F of GI Strip 32 x 6 mm earth continuity conductor and connecting complete all as specified and directed.
30Supply & laying of LT UG cable 1100 V grade, aluminium conductor XLPE insualted, sheathed and armoureed of the following sizes :-
3170 Sqmm 3.5 core
3225 Sqmm 3.5 core
3316 sqmm 4 core
34S&F Rubber matting 19 mm thick LT 1100 V grade of size 0.9 x 1.8 mtrs complete all as specified and directed.
35Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth or laying of cable etc and getting out in soft/loose soil
36Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth or laying of cable etc and getting out in hard/dense soil
37Returning filling in soil including spreading leveling watering and wellrammingin layers not exceeding 25 cm thick complete all as specified and directed.
38Removing excavated soil to a distancenotexc 50 m and depositing where directed at a level not exceeding 1.5 mabobe the starting point complete all as specified and directed.
39Supply & Laying of dry clean river sand for cable cushioning to underground cable including sperading leveling hard punning complete all as specified in MES schedule Part I. Note : for the purpose of payment punned thickness will only be measured
40Supply & laying of Burnt bricks sub class "B" for cable protection complete all as specified and directed.
41Dismantling and removing of the old existig unserviceabe AC plant including compressor, condensors chillers AHUs cooling tower pumps LT panel cablecondensor/chilled wate pipes in plant room only excludingduct chilled water pipe lines from plant to AHUs of following capacities from the site and handlingover to MES store yard :-
423 x 7.5 TR Central type AC palnt
43Supply, installation commissioning and testing of counter flow inducted draft top discharge, bottle type 25 TR FRP cooling tower with FRP body and base, water spray headers, cooling tower fills, fan with motor supporting base frames. fan assembly, motor drive with necessary accessories and suitable foundation, ladder etc complete all as specified and directed. Note :- Inlet and outlet pipes with control valves for cooling tower will be measured and paidseperately.