| 1 | M&L PCC 1:2:4 type B1 (using 20 MM graded stone aggregate) as in bed plates etc complete all as specified |
| 2 | Demolition of brickworks or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc articles complete all as specified |
| 3 | M&L Brick works with sub class \"B\" Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by EIC &SIC |
| 4 | Boring holes 10 mm dia on existing roof with Hilti and supply and fixing of 10mm dia ultimate performance acchor with hax head (Carbon steel) with adhesive |
| 5 | Demolitio of Existing water proofing treatment complete all as directed and removing rubish exceeding 50 m and cleaned the roof surface complete all as specified and as per directed by SIC & EIC |
| 6 | Taking Down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc. It may be applied till 1st floor outer/inner wall, including Scaffolding all as directed by SIC & EIC. |
| 7 | ( M & L ) Rendering 15 mm thick on fair faces of brick work or concrete surface with cement plaster 1 : 4, finishing even and smooth without using extra cement, all as directed byEIC/SIC, Note- Water proofing compound will paid and measured separately |
| 8 | (M&L) Two coats of oil bound distemper and approved shade as per directed by SIC/EIC. Make: Asian,Berger, Shalimar,Nerolac or equivalent as per approved by SIC/EIC. |
| 9 | (M&L) Two coats of cement base paint on old decorated plastered surfaces of walls as per approved by SIC/EIC. |
| 10 | PVC/ACP Panelling high quality /Wall Lining 4 - 5 mm thick solid , Plain colour PVC sheet fixing at site on PVC frame including all corners, edge covering PVC strip as per specified/directed by SIC & EIC |
| 11 | (M&L) Three coats of W/Wash to ceiling surfaces including preparing surfaces plastered or unplastered surfaces complete as per approved by SIC/EIC. |
| 12 | Supply only water proofing compund |
| 13 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plate (Fe-290 Gde-E-165) |
| 14 | M&L for two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer of any description, over 10 cm in width or girth, not other wise described, including preparation of new surface. |
| 15 | S&F Pre painted galvalume aluminuim zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specific. |
| 16 | Pre-painted galvalume aluminum zinccoating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 17 | S&F , 150mm dia UPVC rain water pipe single socketed with rubber joint, jointed with solvent joint fixed to wall complete all as specified & directed by EIC &SIC |
| 18 | S&F Anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm complete, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete and M&L 4 mm thick Gypsum board self imbosed texture Sqm boards, fixed to aluminium snap grid (size of grid 605mm x 605mm) in ceiling all as specified by EIC & SIC. |
| 19 | S/F of powder coating Aluminum doors/2-Track or 3-Track Aluminium sliding Window,Frame section weighing 0.85 to 1.1 Kg/m and shutters aluminum section weighing o.55Kg/mnot more than 4 sqm , including half part with glazing , 4.8 mm thick first quality glasss necessary and half with Pre laminated board 12mm, interior grade both sides laminated joining cleats glazing clips riber neoprene packing handles 2 nos in each door/window hings, latches,tower bolts, door aldrops, door stopers, powder coating snap beading screws etc. complete all as specified. |
| 20 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth |
| 21 | Removing building materials etc to a distance of 1.0 Km or under, - |
| 22 | use and waste the formwork to sides of pillers, posts, struts, piers, columns and stanchions fair finished surfaces of concrete square, rectangualar, including Scaffolding all as directed by SIC & EIC. |
| 23 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diacomplete all as per specified by SIC & EIC |
| 24 | All as per item above (mild steel TMT bars 5 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diacomplete)but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders |
| 25 | M&L for reinfored cement concrete (nominal mix) type A-1 :1 1/2:3 (20 mm graded stone aggregate) as in collumns and beam upt height of 12.00 m approx. |
| 26 | Dismentatling of loose concrete from RCC, cleaning the reinforcement by using deruster of approved make and painting with rust preventer and then putting the weld mesh 40X40mm of 4mm dia and coating primer and bonding agent over RCC surface then shotcreating/guniting the core of RCCM-25 (Design Mix) min 20 mm to 40mm thick with plaster 10mm thick in CM 1:3 including necessary form work and scaffolding, shoring and struting the roof slab beam by putting necessary support to roof and beam and removal after completion of work completed all as specified and directed. (|Note: Shotcreating/guniting at a height approx upto 12.00m) |
| 27 | Dismentatling of loose concrete from RCC, cleaning the reinforcement by using deruster of approved make and painting with with rust preventer and then putting the wire netting of galvanised steel wire mesh of size 25mm and 1.40mm dia fixed with tinned tacks of wire staples and coating primer and bonding agent over RCC surface then shotcreating/guniting the core of RCCM- 25 (Design Mix) min 20mm to 40mm thick with plaster 10mm thick in CM 1:3 including necessary form work and scaffolding, shoring and struting the roof slab beam by putting necessary support to roof and beam and removal after completion of work completed all as specified and directed (Note: Shotcreating/guniting at a height approx upto 12.00 m) Dismentatling of loose concrete from RCC, cleaning the reinforcement by using deruster of approved make and painting with with rust preventer and then putting the wire netting of galvanised steel wire mesh of size 25mm and 1.40mm dia fixed with tinned tacks of wire staples and coating primer and bonding agent over RCC surface then shotcreating/guniting the core of RCCM- 25 (Design Mix) min 20mm to 40mm thick with plaster 10mm thick in CM 1:3 including necessary form work and scaffolding, shoring and struting the roof slab beam by putting necessary support to roof and beam and removal after completion of work completed all as specified and directed (Note: Shotcreating/guniting at a height approx upto 12.00 m) |