Tender For Special Repair/Addition/Alteration Of Kendriya Vidhyalaya (Kv) No 1 Patiala Cantt Building At Patiala Military Station Under Ge (N) Patiala, patiala-Punjab

Military Engineer Services-MES has published Tender For Special Repair/Addition/Alteration Of Kendriya Vidhyalaya (Kv) No 1 Patiala Cantt Building At Patiala Military Station Under Ge (N) Patiala. Submission Date for this Tender is 09-08-2023. Building Work Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38745237
Tender For Special Repair/Addition/Alteration Of Kendriya Vidhyalaya (Kv) No 1 Patiala Cantt Building At Patiala Military Station Under Ge (N) Patiala
Open Tender
Indian
Punjab
patiala
09-08-2023

Tender Details

Special Repair / Addition / Alteration Of Kendriya Vidhyalaya ( Kv ) No 1 Patiala Cantt Building At Patiala Military Station Under Ge ( N ) Patiala

Key Value

Document Fees
INR 2000 /-
EMD
INR 318000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIR/ADDITION/ALTRATION OF KENDRIYA VIDHYALAYA (KV) NO 1 PATIALA CANTT BUILDING AT PATIALA MILITARY STATION UNDER GE (N) PATIALA
Sl. No. Item Description
1Taking down cement plaster on brick Walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
2Rendering 15mm thick i in cement mortar 1:4including mixing of liquid water proofingcompound of approved makeas per manufacturer"s instructions on fair faces of brick work or concretesurfacesor in chajjas / parapet walls etc finished even and fair without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately.
3Supply only liquid water proofing compound complete all as specified and directed
410mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
55mm thick cement plastering in CM 1:3 on fair faces of concrete ceiling surfaces finished even & smooth wihtout using extra cement complete all as specified and directed.
6Material & Labour for preparation of newly plastered or unplastered surfaces of wall applying two coat of distemper oil emulsion white/tinted with 1mm thick wall care putty finished surface complete all as specified and directed by Engr -in - charge.
7Material & Labour forpreparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed by Engr -in - charge.
8Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engr -in - charge.
9Material and Labourfor 20mm thick screed bed in CM 1:6 for laying floor finish all complete all as specified and as directed.
10Material and Labourfor 25mm thick, PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate), as in floor, sub basefinished fair & even without using extra cement complete all as specified and directed .
11Material and Labourfor full body, vitrified, stain & scratch resistant, joint free, premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors/skirting etc. in any pattern of light & dark tiles as approved, set and jointed with adhesive of Sika (Ceram Grey) @ 5 Kg/sq.m or equivalent as approved by GE and pointed in white or coloured cement to match, in floors etc. complete all as specified and directed.
12Dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tile to store and rubbish off the premisescomplete all as specified and directed.
13Material and Labourfor Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, complete all as specified as directed by Engr-in- Charge
14Material and Labourfor Virified Ceramic tiles 8-10 mm thick dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with pigment to match the colour of tiles complete all as specified.
15Material and Labourfor Virified Ceramic tiles light shade 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colour of cement to match the coloured of tiles complete all as specified.
16Material and Labourfor Vitrified ceramic coloured (colour & shade as approved ) tile of size 600x100x10 mm thick ason vertical surfaces such as skirting/ dado etc length of each tile not less than 600 mm , set and jointed in cement slurry over and including 10 mm thick rendering in cement mortar(1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified.
17Material and Labourfor Glazed ceramic tiles (coloured tiles) in vertical surface 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4on other than fair face of brick work all as specified and directed.
18Dismantling loose/disintegrated portion of RCC Chajjas, bands, shelves, beams, column or slab and similar work including support if required and stitching of cracks with MS U clamps of 8mm dia @ 150mm c/c with inserting concrete block strengthed with cement mortar 1:3 mixed with adhesive chemical (polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with 10mm thick plastering in CM 1:4 finished even & smooth without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
19Taking down chowkhats or frames of any description exc 1.5 Sqm but n. exc. 4 sqm each (without taking off shutters from the frame) including cutting hole to size for receive fresh PCC of hold fast and making good the disturbed surface complete all as specified and directed.
20Taking down chowkhats or frames (without taking off shutters from the frame) not exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified.
21Supply & Fix Solid PVC Double door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification complete all as specified.
22Supply & Fix Factory made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Wood grain laminated & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification all as specified and directed
23Material and Labourfor Powder coated (Minimum thickness of powder coating 50 micron) Anodised aluminium frame, shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
24Supply & Fix 12 mm thick high density fibre board pre-laminated in both sides (water proof) below & above middle/lock rail in powder coated aluminium doors and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc aluminium beads 20mm size with and complete all as specified and directed by Engr-in-Charge.
25Supply & Fix 4mm thick tinted glass fixing in aluminium door/ window including rubber gasket & beading complete all as specified and directed.
26Supply & Fix 125 mm long butt hinges, medium weight, cold rolled, mild steel and fixed all as specified
27Supply & Fix 150 mm long Aluminium handles cast type anodisedall as specified
28Supply & Fix 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed all as specified
29Supply & Fix Mild steelsliding door bolt 300 mm longplate type stove enamelled black with bright bolt not less than 12mm diawith & including a minimun of 6 bolt nuts four on bolt plate and two on staple plate fixed complete all as specified & directedby Engineer-in-Charge.
30Supply & Fix floor door stopperof aluminium body overall length of cover plate 40mm fixed all as specified & directed
31Material and Labourfor taking down Shutter of any description exc 1.0 sqm but nexc 2.0 Sqm each all as specified
32Supply & FixPressed steel frames made of MS sheet of 1.20mm thickness of size 105 x 60 mm for doors with single or double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts etc complete all as specified. (Note :- Distrubed portion of existing floor/ wall/ tile/ plaster etc during fixing of chowkhats shall be repaired to match with exisitng finish.Cost of the same will be included in this items).
33Material and LabourforPCC 1:3:6 type C-0 using 12.5 mm graded stone aggregates as in padding over roof/hold fast filling inside frame & hold fasts etc complete all as specified
34Material and Labourfor preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
35Supply & Fix Flush shutters 30mm thick, solid core construction, with particle board core and plywood face panels, commercial type on both sides all as specified & directed.
36Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified & directed.
37Demolition of Cement Concrete as in ground floor & paving n. exc. 15cm thick (above or below G.L.) all as specified & directed.
38Plain cement concrete 1:7:12 mix, type E-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed.
39Rendering 15 mm thick in cement mortar 1:3 , mixed with water proofing compound, on brick or concrete surfaces of wall of sunken portion , trowelled to even and fair finish with WPC paid and measered seprately complete all as specified.
40Providing 40 mm dia GI pipe medium grade spouts 60 cm long complete all as specified and directed.
41Supply & Fix stainlesssteel tubing of 25 mm dia chromium plated mininum 1.0 mm wall thickness as in curtain rod complete including Supply & Fix 02 Nos stainless steel brackets/finials fancy type, stops fixed with stainless screws etc all as specified & directed as in repair . Note : For the purpose of measurement and payment running length of curtain rod only shall be considered.
42Supply & Fix Vitreous china squatting pan, "Orissa" pattern, size 580x440 mm white, with integral foot rests, CI "P" or "S" traps 100mm & PVC flush pipes 32mm diaincluding connecting to trap and to flushing pipe, anti-syphonage pipe etc including all joints and making good to floor all as specified
43Supply & Fix vitreous china premium/1st quality wash down water closet wall hung EWC P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, anti syphonagee pipe etc.with flushing pipe PVC 32mm dia and including plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc. and including all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing including 100mm dia cast iron sanitary connections, short connections pipe of length upto 600 mmand Cutting holes in or through walls, packing with PCC 1 : 2 :4 complete and taking down existing of any description/size complete in all respect all as specified.
44Supply & Fix in repairPVC 10 litre capacity valve less syphonic action type, flushing cistern, low level, white/coloured with inlet ball valve, float, PVC bend and handle including brackets, etc. complete all as specified by Engineer in Charge.
45Supply & Fix Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including flat back ,white (min) with grating and union for discharge pipe including waste pipe etc. complete all as specified and directed
46Supplying and fixing in repairs 15mm dia chromium plated brass, auto closing urinal valve complete all as specified and directed by Engineer-in-Charge.
47Supplying and fixing in repairs Vitreous china urinal partition white of size 310x700mm, complete all as specified and directed by Engineer-in-Charge
48Supply & Fix vitreous china premium/1st quality wash basin (counter top), white/ivory/off white, size 580x430 mm including Supply & Fix all accessories as recommended by manufacturer incl. CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union andincl 32mm brass CP waste coupling and complete fixed in position in all respect as per manufacturer"s instructions and taking down existing WHB of any description/size all as specified. Note : The items for counter will be measured and paid separately.
49Formwork to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work, not exceeding 200 mm thickall as specified
50Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed
51Material & Labour for nominal mix 1:2:4 type B0 using 12.5mm stone aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
52Supply& Fix in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer in Charge.
53Supply& Fix sinks with drainage board made of stainless steel 0.80 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified.
54Supply & Fix in repair white ceramic laboratory sink of size 600x450x250mm including waste fittings and all accessories as specified and directed by Engineer-in-Charge
55Dismantling old unserviceable cement concrete/PVC water tanks of capacity exc 500 ltrs & n.exc 1000 Ltrs including supplying & fixing of PVC water storage tank 1000 ltr capacity HDPE triple layered ,white colourcylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight20 mm - 210 gms ) fixed as in repairs.Note :(i) Inlet, outlet & wash out pipe will be measured paid for separately.
56Supply & Fix stainless steel plate rack of size 900x750x250mm made out of 1.0mm thick stainless steel sheet of first quality fixed in wall using stainless screws complete all as specified and directed by Engr-in-charge
57Supply & Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified
58Supply & Fix Roof trusses (framed),(Fe 410-W (Gde-E-250 quality -A) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.all as specified.
59Preparation of new surface of steel and applying two coats of synthetic enamel paint over a coat of red oxide on surfaces of any description, over 10 cm in width or girth not otherwise described as in truss complete all as specified and as directed.
60Material & Labour for preparation old painted steel surface any description over 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint complete all as specified.
61Material & Labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 all as specified
62Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified.
63Demolition of mud phuska on roof any thicknessincl plastering and leeping all asspecified and directed.
64Material & Labour for wire brushing, cleaning top surface ,Scarping surfaces of roof by wire brushing and removing all loose dust and cleaning and washing down the surfaces with water complete all as directed.
65Providing and laying3mm thick APP (Atactic Polyproplene Polymer) modifiedprefabricated five layer, weightnot less than 3.0 Kg/Sqm water proofingmembrane black finished, reinforced with non-woven polyster matt make as approved including on a coat of bitumen primer @ 0.40 ltr/sq.m by the samemembrane manufacturer ofdensity 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm thick 5 layered APP membrane shall be laid using butane torch and sealing alljoints etc after the surface complete as per standard practice as per manufacturers instructions.The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength in longitudinal and transverse direction at 23 degree C as 650/450N/5cms(ii) Tear strength in longitudinal and transverse direction as 300 / 250 N.Softening point of membrane not less than 150 degreeC Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147)
66Material & Labour for 15 mm thick screed bed in CM 1:4 for laying floor finishes with WPC (paid and measered sepretaly) complete all as specified and directed by Engr-in-Charge.
67Supply & Fix factory made, un-reinforced precast cement concrete tiles of area exe 0.06 but not exc 0.09 sqm each, 22mm thick with grey cement and no pigment ofmachine pressed, as on roof surface, confirming to IS 1237-1980, incl set, jointedand pointed with grey cement and no pigmentslurry complete all as specified and directed.
68Material & Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in roof kerbs, benches and water troughs etc. including necessary moulding complete all as specified & directed.
69Taking upor down 15mm dia GI Tubing and connection or removal to storecomplete all as specified..
70Taking upor down 20mm dia GI Tubing and connection or removal to storecomplete all as specified..
71Supply & Fix 15mm bore GI tubing medium grade with all fittings fixed to walls or laid in floorscomplete all as specified.
72Supply & Fix 20mm bore GI tubing medium grade with all fittings fixed to walls or laid in floorscomplete all as specified.
73Supply & Fix 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as specified
74Supply & Fix 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as specified & directed
75Supply & Fix in repair 15mm angle cock/ stop cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed by Engineer in Charge.
76Supply & Fix in repair 15mm bib taps, fancy type cast copper alloy CP with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified by Engineer in Charge.
77Supply and fix WHB Mixer valve for mixing hot and cold water of Brass Chromium Plated screwed down for 15mm dia iron pipe including taking down complete all as specified and directd by Engineer-in-Charge.Note: The quoted rate shall include the long braided hoses 450mm long for connection to mixer complete.
78Dismantling CI/PVC pipe alongwith fittings of 75/100mm dia,below or above GL, laid in floors or fixed to walls jointed in cement mortar and taking out complete all as specified
79Supply & Fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors as specified and directed
80Supply & Fix PVC (SWR) bend any radius 110 mm bore as specified and directed
81Supply & Fix 100mm dia cast iron soil, sand cast pipes, waste and vent pipe, in any length with or without ears with cement joints laid in trenches, in floors or fixed to walls as specified and directed
82All as per Item No 81 here in before but 75mm bore pipe complete all as specified.
83Supply & Fix in 100 dia CI bends, diminishing pieces or tapers all as specified
84All as per Item No 83 here in before but 75mm dia all as specified.
85Supply & Fix in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc fixed in repairs.as specified and directed
86Supply & Fix branch pieces, 100mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches as specified and directed
87Supply & Fix branch pieces, 75mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches as specified and directed
88Supply & Fix 75mm cast iron vent cowls as specified and directed
89Supply & Fix in repairs CI Floor trap long neck 100 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc fixed in repairs.as specified and directed
90Supply & Fix 6mm thick looking mirror with smooth finish bevelled edges/sidesfixed to wall with stainless steel brackets/plugs/connecter/spacers/ screws etc. chrome finish with PVC back 5mm thickcomplete fixed in position all as specified and directed.
91Supply & Fix in repair Towel Rail 450mm long of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) as specified and directed
92Supply & Fix gypsum board 8-10mm thick in ceiling fixed with screws as per manufacturer instructions plain/ colour fixed with steel snap grid (powder coated bottom side) with T and L (25mm*30mm*1mm thick)section of size 600mmx600mm placed in ceiling L section fixed with wall with PVC rawal plugs and steel screws @600mm centre to centre and suspended/provided 5mm dia galvanised bar @1 sqm hanging arrangement and levels incl adjustable clips, complete all as specified in clause 10.38 of schedule part-1 complete all as specified (Note- if any minor electrifical and fixtures distributed there in will be match and fixed as existing) as specified and directed
93Supply & Fix false ceiling of 12.5mm thick gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer"s instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by Accepting Officer and including supply and fixing of items all as specified as below :- (a) Suspended Plain Ceiling includes Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres. (b) Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid.(c) Intermediate channel {Material-GI(IS513),YS-260Mpa, Finish-Galvanised 150GSM(IS277) } is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} (d) Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c.(e) Single layer of 12.5mm tapered edgePlain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. (f) Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing withPro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape and applying 02 coats of interior emulsion over a coat of wall care putty including a coat of primer all as specified. Note : Thecomplete item shall be gotexecuted through the authorised applicator of manufacturer only all as specified and directed.
94Supply & Fix PVC hollow Wall panelling of section sizes 150x10 mm (colour/pattern as approved by Accepting Officer) complete fixed in position in all respect including supply and fixing of all accessories like fasteners/screws/solvent etc all as recommended by manufacturer all as specified.
95Material & Labour for Granite16-18 mm thick work (of any type)(table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including nosing edges and chamfered complete all as specified
96Excavation over areas, n exc 1.5 m deep and getting out all as specified & directed
97Excavation in trenches, n exc 1.5 m wide depth & getting out all as specified & directed
98PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations all as specified & directed
99Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter all as specified & directed
100Formwork to sides of pillars, posts, struts, piers, columns and stanchions for Rough finished for concrete surfacesall as specified & directed
101Mild steel (TMT bars) bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips alla as specified & directed
102Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed
103Material & Labour for nominal mix 1:2:4 type B0 using 12.5mm stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified & directed
104Material & Labour for nominal mix 1:2:4 type B0 using 12.5mm stone aggregate for Columns, pillars, piers, posts and struts all as specified and directed
105Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of floor or the side of waist slab with suitable arrangement including name of any size of boardall as specified & directed
106Material & Labour for 20 mm thickMarble, white colourmachine cut,in skirting, riser of stair in screedbedded jointed and pointed with white cement slurry including cutting and polishing,types all as specified & directed
107Material & Labour for 16-18mm thick Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.5 sqm area fixedin vertical wall or column with and including one number SS clamps (grade - 202) of flat-30mm X 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment all as specified and directed
108Material & Labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and ornamental type(exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeFe 410W (Gde- E- 250) quality-A Fe- all as specified & directed.
109Material & Labour for ACP sheet of 4 mm thickness of approved plain colour/ shade for chajjas/ sunshades/ cladding and the like works etc. fixedto frame work of MS/ Aluminium/ Hollow sections of any size description including finishing all the joints with silicon or as per manufacturers instructions complete in all respect and complete fixed in position incl scaffolding/ ladders etc as required and also making the joint between all as specified and directed. Note : Frame work shall be measured and paid separately
110Material & Labour for 4 mm thick exc 0.05 sqm in each pane Sheet glass , ordinary quality and glazing with oil putty in squarefixed in repairs all as specified & directed
111Complete removal of existing treatment of any type/ description such as distempering work, internal surfaces of old walls & ceiling with mechanical means/ dust free grinder complete all specified and directed
112Applying 02 coats of interior emulsion paint (white shade) @10 sq.m/litre/2coats by using roller to wall surfaces over & including a coat of interior wall primer @10 sq.m/litre/1 coats as recommended for under coat by manufacturer of interior emulsion including acrylic thick wall care putty 1.5 to 2.5 mm thick complete all as specified and directed.
113Applying 02 coats of interior emulsion paint (white shade) @10 sq.m/litre/2coats to ceiling surfaces over& including a coat of interior wall primer @10 sq.m/litre/1 coats as recommended for under coat by manufacturer of interior emulsion by usingincluding acrylic thick wall care putty 1.5 to 2.5 mm thick complete all as specified and directed.
114Material & Labour for 18 mm thick with minimum density 600 Kg/cu.m LEAD FREE PVC Celuka ply of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed.
11518 mm thick with minimum density 600 Kg/cu.mLEAD FREE PVC Celuka ply of single rigid laminated of approved colour and other side plain white colour fixed withscrews andsolvent cement/ adhesive to make kitchen cabinet shutter and shelvescomplete as per manufacturer’s specifications complete all as specified and as directed.
116Material & Labour for piano/ contineous hinge of size 19 mm stainless steel bright finish complete in all respect and fixed in position all as specified.
117Material & Labour for D-type cabinet handles premium quality, stainless steel 304/ gloss chrome/ SN finished200mm long matt finished complete fixed in position all as specified.
118Material & Labour for coloured chequred cement concrete tiles 30 cm x 30 cm x 20mm thick, made of grey cement set and jointed inneat cement slurry with grey cement and pigments as infloors to match the shade over screed bedor bedding layer or mortar 15mm thick in cement mortar 1:4 for laying floor finished, complete all as spcified and directed. .
119Material & Labour for washed stone grit plaster on exterior walls in two layers, under layer 12mm thick in cement plaster 1:4 (1 cement: 4 coarse sand) over and including binding of chicken wire mesh with existing reinforcement after furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3Kg of cement plaster 1:1/2:2(1 cement : 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chipping including taking down existing cement plaster complete all as specified and directed.
120Taking down carefully existing points wiring on surface conduit/concealed conduit forlight/ fan/ socket/ power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
121Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 1.6mm thick sheet, Min 60mm deep, suitable size) concealed in wall, including 3mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. (switches, socket shall be measured and paid separately under appropriate item of BOQ/Sch "A") (Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular switches: Modular cover plate and metal flush boxes included in Point wiring)
122All as Ser Item No 121 here-in-before but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathedcable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
123All as Ser Item No 121 here-in-before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
124All as Ser Item No 121 here-in-before but one 5Amp socket point on independent board but with other switches complete all as specified and directed..
125Material & Labour for modular switch 1 way 6 A, 1 module complete all as specified and directed.
126Material & Labour for modular socket, 6A-2/3 pin combined, 2 module.complete all as specified and directed.
127Material & Labour for modular switch16 Amps, 1 module with indicator complete all as specified and directed.
128Material & Labour for modular socket16 Amps, 6 pin, 2 module complete all as specified and directed.
129Material & Labour for fan regulator electronic type 5 speed modular type 2 module complete all as specified and directed. complete all as specified.
130Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, complete all as specified and as directed by Engineer-in-Charge.
131Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting with old bracket any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
132Supply and fixing recessed LED ceiling mounted with wide light window for maximised glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling finishes complete fitting with separate electronic driver and high brightness LED 36 Watt, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from connector/ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95(e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Minimum 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 3 kV. (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
133Supply and fixing LED batten fitting complete tube polycarbonate housing 1 x 20Watt, appx 4 feet long, with decorative box linear LED lighting fixture with CRCA housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g) CRCA pre coated housing with coloured plastic end cap.(h) LED Driver of the same make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K(m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
134Supply & Fix MCCB DB TPN 4 Way vertical type bus bar capacity 125 Amp factory made 415 volts IP 43 protection class metal double doorwith Shrouded Neutral Bar & Pan assembly with connecting link complete including one MCCB upto 125Aafter dismantling old one complete all as specified and directed.
135Supply & Fix MCCB DB TPN 4 Way vertical type bus bar capacity 200 Amp factory made IP 54 protection class metal double doorwith Shrouded Neutral Bar & Pan assembly with connecting link complete including one MCCB upto 125A 415 volts after dismantling old one complete all as specified and directed.
136Supply & Fix MCCB 63 Amp 16 KA 4 pole or fixing in DB complete all as specified and directed.
137Supply & Fix MCCB 125 Amp 25 KA 4 pole for fixing in DB complete all as specified and directed.
138Supply & Fix Single pole & neutral 8 waydoor closer DB with 200 amps rated bus bar.compelete all as specified and as directed.
139Supply & Fix MCBs240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB. (DB will be measured and paid separately under respective items of BOQ):- (a) MCB SPN 40 Amps.
140(b) MCB SP 6 to 32 Amps
141(c) MCB SP 40 to 63 Amps
142Supply and fixing for sub main wiring Four single core PVC insulatedand unsheathedFRLSH cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit of suitable size with 10 Sqmm2 single core PVC copper conductor cable as in earth wire system, including taking out old wiringcomplete all as directed.Note 1: Neccessary cutting chasing wherever requiredand making good the disturbed surface shall be part of job at no extra cost 2. Allcopper wires must be connected to DB"s WITH PROPER SIZE COPPER THIMBLES.
143Supply and fixing for sub main wiring with two single core 6 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia incl 6.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. Note 1: Neccessary cutting chasing wherever requiredand making good the disturbed surface shall be part of job at no extra cost.2. Allcopper wires must connected to DB"s WITH PROPER SIZE COPPER THIMBLES.
144Supply and fixing for sub main wiring two single core PVC insulatedand unsheathedFRLSH cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system, including taking out old wiringcomplete all as directed. Note 1: Neccessary cutting chasing wherever requiredand making good the disturbed surface shall be part of job at no extra cost. 2. Allcopper wires must connected to DB"s WITH PROPER SIZE COPPER THIMBLES.
145Supply and fixing earth metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall all as directed by Engineer-in-charge.
146Supply and fixing Earth continuity conductor 4 mm dia main lead fixing to wall on batten or recced or chase or buited in ground or drawing in coduit/pipe or fixed to poles or any other indicated situations for loop earthingcomplete all as specified and directed.
147Taking down ceiling fan and refixing after neccery cleaning complete all as specified and directed.
148Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V, min air delivery 220 CFM), with 5 star service value, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum, with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
149Taking down Exhaust fan and refixing after neccassery cleaning complete all as specified and directed.
150Supply and fixing Ceilingfan down rod3/4 feet of suitable dia compelete all as specified and as directed.
151Taking down LED tube light fitting 18/20watt and refixing after neccassery cleaning complete all as specified and directed.
152Dismantling/taking down window type AC 1.5/2 Ton from site, opening and reinstalling AC in thesame Location after repair work complete all as specified and as directed.
153Dismantling/ taking down Split type AC 1.5/2 Ton from site, opening, cleaningand reinstalling AC in the same location including gas charging fitting with suitable size copper pipe line and flair nuts of same sizeboth unit outdoor/indoor unit complete and testing on full load etc after repair work complete all as specified and as directed.
154Supply & Fix Prestressed concrete pole, 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom class 9 for making two pole structure complying with requirement ofrelevant IS and including marking alternate RED and BLACK strips 30 cm high each , total of 8 Nos , commencing from the top of PCC coping with two coats of synthetic enamel paint over a coat of primer and writing pole Nos (letters and figures) (Block, Roman, Italic or Indian) of size as directed with synthetic enamel paint complete all as specified and directed. Note:Earth work, PCC, GOD, MS work etc shall be measured and paid seperately under relevant items.
155Plain Cement concrete 1:4:8 type D-2 using 40 mm graded crushedstoneaggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
156Plain Cement concrete 1:3:6 type C-2 using 40 mm graded crushedstoneaggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortarapplying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
157Plain Cement concrete 1:2:4 type B-1 using 20 mm graded crushedstoneaggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
158Supply and replaceswitch gang operated, triple polewith drop out fuses, mechanically operated, mounted on fifteen (15) insulatorsand steel framewith operatingmechanismand operating rod of GI tubing25 mm boremedium gradewith necessary clamps, tobe operatedfrom ground level 11000 volts grade working pressureand current rating up to 200 ampscomplete all as specified and directed.
159Material & Labour for Cross arms, bracing, supports, clamps and back plates fabricated from structuralsteel sections incl nuts, bolts, washers, welding, bending cold or hot,, drilling holes for bolts in any shape or size as indicated or directed and inclusive or one primer coat, one under coat and one finishing coat of super enamel paint complete all as specified and directed.
160Supply and fix lightning arrestor11 KV(rms) havingdischarge capacity 65 KA, “POLYMERIC HOUSING” including necessary connections with HT over head lines complete all as specified and directed.
161Supply , installing, testing and commissioning of outdoor type step down transformer 11000/433 volts (at no load), AC, 3 phase 50 Hz, copper wound type complete with standard fittings, 11 KV 3 phase , LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS: 1180 (with latest amendments) of capactiy 400 KVA, core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes/ fins delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol DYN-11(Vector group) with neutral brought out on secondary side (LV side ) and having tapping at ±5%HV side to be changed by means of hand operated off load tap changer gear. The maximum temparature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temparature of 40 degree celsius. The transformer shall be IS 1180 marked energy efficient level 2 and shall comprise of the following :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing,copper rods, nut and washers. (b) One cable box on LT side (secondary side ) consisting of 04 No of porcelain bushing with copper rod, complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fills dehydrating agents (silica gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g)One number 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsious wth metal guard having max perimeter reading tempreture indicator with resisting device for transformer (h)Two earthing terminal on tank cover to facilitate fixing of 32x6 mm GI earth strip for earhting of neutral and body
162(j)Rating plate and terminal marking plate (k) Oil level gauge (l)Oil drain filter valve (m) Lifting lugs (n)Oil filling holes with cap/ plug with connecting plate complete (o)Air release plug (p)Four plain solid cast steel detachable rollers (q)Extra bushing for neutral, outside LT cable box for proving independent earthig for neutral (r)First filling new and unused transformer oil IS-335/93 (forth version) marked (make -HP/power oil or equivalent as approved by GE) filtered and tested dielectric strength at 2.5 mm air gap between testing electrode asper IS 335. Note: Certification of di electric strength shallbe submitted by the cotractor after filling the oil. The transformer shall be got tested from SEI before commissioning. the cost of all tghe above provisions is deemed to be included in the unit rate quoted by the contractor.
163Supply and laying or fixing or laid in trenches/ ducts / underroads/ hard standing /along poles and testing HT cable XLPE, insulated and PVC sheathed screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 11000 (E) volt gradewith stranded aluminium conductor having cross sectional area 95 Sqmm3 core conforming to IS-7098 (Part-II -2011) with upto date Amendments complete all as specified and as directed. Note ;- Excavation and earth work, sand cushioning, Protection cover & protection pipe shall be measured and paid separately under respective item of BOQ.
164Material and Labour for fixing Steel tubular swaged polestype 410 SP-31 (9.00mtr long)complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified includinginternal surface of steel tubular polethrough out and external surface up to planting depth shall bepainted with bituminous paint andremaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in BOQ items.
165Supply and fixing energy efficient LED street light fitting of 60W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, including electric connection, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type with old bracket complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : Minimum IP65. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily).
166Supply & Fix PVC insulated and sheated copper conductor of size 1.5 Sqmm 3 core from junction box to street light fittings complete all as specified and directed.
167Supply & Fix Cable jointing kit for 11 KV (Earthed) grade cable for OUTdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70- 120 sqmm complete all as specified.
168Material & Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32X6 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3.5:6 type c1 with PCC cover and, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
169Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
170Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.
171Supply and fixing of GI tubing light grade of 50 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.
172Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 300 Sq mm 3.5 Core complete all as directed.
173Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 240 Sq mm 3.5 Core complete all as directed.
174Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150Sq mm 3.5 Core complete all as directed.
175Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70Sq mm 3.5 Core complete all as directed.
176Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50Sq mm 3.5 Core complete all as directed.
177Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 4 Core complete all as directed.
178Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core complete all as directed.
179Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 2 Core complete all as directed.
180Supply and fixing in replacement of Three-Phase load of 5 KW for automatic Street Light control Switch using Infrared Sensor based NATURAL SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level, required illuminance Level for Switching ON is = 30 Lux and for Switching OFF = 10 Lux. The Sensor should have part night operation facility of minimum 4 hrs. to max. 12 hrs. The Sensor along with 3 Nos suitable Contactor each 20 to 25 Amp current rating incoming MCBs & Outgoing MCBs of 20-25 Amps (03 Nos) and circuit should also have provision for manual operation (i.e. Sensor Bye-pass option). circuit should be multistrand FRLSH min size ofminmum 10 sq.mm copper cable. Selection operation should be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof termite proof and FR grade special mounting compound (sintex made SMC junction box) confirming to IP 54 including taking down old unserviceable timer any type complete all as specified and as directed by Engineer-in-Charge. .
181Supply and fixing gun metal test point terninal block of size 75 x 75 x 25 mmdrilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
182Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel board in replacement of old unservicable panelsuitable for 3 phase,4 wire 415 volt 50 HZ factory fabricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for natural flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 1200 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all control PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, ferruled for proper indication, fixed on PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate complete with following accessories:-NOTE:-All MCCB"s used shall be thermal magnetic overload and short-circuit protection class with adjustable thermal and magnetic levels. (a) ACB Microprossessor relaese based type 50Hz, 4 Pole 800Amp 50 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION - 1 No (As incoming)(b) MCCB 4 Pole 400Amp 50 KA -2 No (As out going) (c)MCCB Microprocessor released based 50Hz, 4 Pole 125 Amp 25 KA - 1 No(As out going) (f)Digital voltmeter (0-500V ) (g) Digital Ammeter suitable rating(h)CTS(j) Selector switches and RYB LED indicator Lamp (set of three)
183Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 40x40x6 mm frame bottom of the panel board, grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland and with alluminium bus bar three phase and neutral of capacity of 1.5 time from themain incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material:- NOTE:-All MCCB"s used shall be thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. MCCB 4 pole 320 amps 50 KA- 01 No (incoming) MCCB 4 pole 250 amps 36 KA- 02No (To wall mounted panel) MCCB 4 pole 125amps 25 KA- 01No (TO TPN DB FOR AC LOAD) MCCB 4 pole 125amps 16 KA- 01No (to road sec light panel) change over switch 4 pole 315 amp 415 Voltsuse fitted onthe panel boardAmpere meter (digital type) 0-500 amps with selector switch - 01 No Volt meter (digital type) 0-500 volts with selector switch - 01 No Indicator lamp RYB (3 Nos) - 01 Set
184Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 40x40x6 mm frame bottom of the panel board, grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland and with aluminium bus bar three phase and neutral of capacity of 1.5 time from themain incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material:- NOTE:-All MCCB"s used are thermal magnetic overload and short-circuit protection class with adjustable thermal and magnetic levels.MCCB 4 pole 320 amps 50 KA- 01 No (incoming)MCCB 4 pole 250 amps 25 KA- 02No (To LT PANELS of qtr blocks) MCCB 4 pole 63amps 25 KA- 03No (01 outgoing to sec light TIMER panel AND 02 for qtr DBs block no 6&7) Ampere meter (digital type) 0-500 amps with selector switch - 01 NoVolt meter (digital type) 0-500 volts with selector switch - 01 NoIndicator lamp RYB (3 Nos) - 01 Set
185Supply, Install , testing and commissioning of Wall Mounted LT panel in replacement of old unservicable panelof suitable size for 3 Phase 415 Volts Indoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted onangle iron 40x40x6 mm frame of the panel board , fitted on wall by proper cementong work, thimbling and cable entry boxes with cable gland and thecopper bus bar should be 1.5 time from themain incoming.covered with protection mesh of 6mm iron wire square mesh having proper opening and closing arrengement with locking arrengement andstandard danger sign board plateNOTE:-All MCCB"s used shall be thermal magnetic overload and short-circuit protection class with adjustable thermal and magnetic levels. MCCB 4 pole 200 amps 25 KA- 01 No (incoming)MCCB 4 POLE 100 amps 25 KA- 04No (outgoing to V TPN DB for ligght/fan/socket point) Ampere meter (digital type) 0-100 amps with selector switch - 01 NoVolt meter (digital type) 0-500 volts with selector switch - 01 NoIndicator lamp RYB (3 Nos) - 01 Set
186Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 40x40x6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland and with alluminium bus bar three phase and neutral of capacity of 1.5 time from themain incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material :- NOTE:-All MCCB"s used are thermal magnetic overload and short-circuit protection class with adjustable thermal and magnetic levels.MCCB 4 pole 250 amps 25 KA- 01No (incoming)MCB TPN100 Amp 16 KA -03(03 for qtr TPN DBs ) MCB TPN63 Amp 16 KA -01(01outgoing to road sec light TIMER panel ) Ampere meter (digital type) 0-100 amps with selector switch - 01 NoVolt meter (digital type) 0-500 volts with selector switch - 01 No Indicator lamp RYB (3 Nos) - 01 Set
187Material & Labour for taking out concrete poles/struts, any sizeand taking safe custody of MES store yard complete all as specified & directed by Engr-in-charge.
188Material & Labour for taking out concrete poles/struts, any size including taking down of OLD/US LED street light from the PCC poles and taking safe custody of MES store yard complete all as specified & directed by Engr-in-charge.
189Dismantling/Taking down old ACSR conductor from LT pole by opening all connectionscomplete all as specified & directed by Engr-in-charge
190Material & Labour for taking out concrete TWO pole structure of GOD system, any size including taking down of all insulators and switching system from the PCC poles and taking safe custody of MES store yard complete all as specified & directed by Engr-in-charge.
191Supply & Fix 120 watt LED Flood light luminaire of epoxy powder coated CRCA MShousing with epoxy powder coated aluminium heat sink with system wattage, with 120 degree view angle,>100 lumen/watt,luman maintenance>90% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of same manufacturer.
192Excavation in trenches soft/loose soil n.exe 1.5 mtr wide and not exc 1.5 mtr deep for laying of cables including taking down complete all as specefied and directed.
193Returning filling in of layers including spreading, levelingcomplete all as specefied and directed.
194Removing surplus spoil to a distance not exceeding 50 m and depositing where it is directed complete all as specefied and directed.
195Material and labour for precast concrete cable covers class class HV, type 1 with peak, size 300mm x 180mm x 40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
196Material and labour for precast concrete cable covers class class LV, type 1 with peak, size 250mm x 150mm x 40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
197Material and labour for sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed. (Note:- Punned thickness shall be considered for payment purpose)
198Boring of horizontal holes by manually without disturbing the top surface (trenchless) under road, pavement, hardstanding suitable for inserting GI pipe any dia upto 80mm including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
199Material & Labour for providing platform for placing of Transformer size of 3.0 x 2.5 mtr with height of 900mm above GL and 300mm below GL with PCC 1:2:4 type B1 using 20mm stone aggregate as in foundation and platform including necessary flat angle iron 40x6 mm and XPM for fencingaround the transformer for safety.all as specified and directed by Engineer in Charge.
200Supply, Install, testing and commissioningLT feeder pillar BUS BAR BOXof suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board IP 54, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted onangle iron 25x25x6 mm frame of the panel board, thimbling and cable entry boxes with cable gland and thecopper bus bar should be 400AMP Capacity all as specified and directed by Engineer in Charge.
201Supply and Fix Standalone All -in-One LEDSolar Street Light Fittings 36 Watt, high efficacy LEDs 120 lm/watt, Silicon encapulated high efficiency MPPT Charge controller with dusk down sensor, uniquely designed extruded aluminium housing with IP-66 protection for better heat dissipation & strategically placed perforations allowing natural air passive circulation within & into the housing for improved thermal management of internal components, including mounting brackets for fixing complete all as specified and directed comprising :- (a)Mono Crystalline SPV Module 150 Wp. (b) VRLA, Solar Gel tubular Battery 12 v, 150 AH (13.6V - 14.4V)with 03 days backup and 05 years warranty.(Li Ion battery 150 mh) (c) Hot dipped GI tubular pole single arm with base plate, polished finish surface, 6 mtr long above ground, 80 mm dia with wall thickness 3 to 4 mm complete as per manufacturer"s instructions and design by OEM. Note : (i)Excavation and earth work shall bemeasured and paid separately.
202Supply and fixing cable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and grouting lugg of suitable size including gouted in PCC foundation of suitable size complete all as directed.
203Supply and fix PVC Sintex box having aluminium bus bar 4 pole suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper comductor for connection and fixing arrangement to pole all as specified and directed by Engineer-in charge
204Supply and fixing of GI tubing light grade of 100 mm dia for cable protection on pole/wall/floor/or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the distrubed surface of wall, floor or roof etc all as specified and directed.