| 1 | Earthwork in excavation in trenches for foundation pipes cable etc in ordinary soil (Loam clay or sand) including lift upto 1.5m & lead upto 50m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer I/C within a lead of 50m. (SOR : 251) |
| 2 | Preconstruction Antitermite treatment of soil under floors using chemical emulsion (Sch No. 8.01) |
| 3 | Sand filling in plinth under floors including watering and ramming including lead upto 50 m and lift upto 1.5 m.etc all complete. (Kanpur SOR Chapter No. 2 item 7 DAR ref to 2.27) |
| 4 | Providing and laying cement concrete 8:4:1 [stone ballast 8 (40mm normal size) : 4 sand : 1 cement] and curing etc all complete. (SI No. 281) |
| 5 | RCC with 1:2:4 with cement, coarse sand and 20mm stone grit in Raft foundation and footings including all materials, labours, T&P etc all complete. (Sch 283) |
| 6 | RCC with 1:1.5:3 with cement, coarse sand and 20mm stone grit in columns, roof/T beams & slabs including all materials, labours, T&P etc all complete. (Sch 289) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | M-150 brick work in 1:4 one cement and 4 coarse sandmortar in foundationincluding supply of all materials, labour and tools and plants etc. required for proper completion of the work. (PWD SI No. 305a) |
| 9 | M-150 brick work in 1:4 one cement and four coarse sand mortar in Superstructure including supply of all materials, labour and tools and plants etc. required for proper completion of the work.(PWD Sch 305a+309+310) |
| 10 | M-150 brick work in 1:4 cement and coarse sand mortar in Superstructure but for wall thickness 12cm including supply of all materials, labour and tools and plants etc. required for proper completion of the work. (PWD Sch 305a+309+310A) |
| 11 | MS or iron work in angle Iron door and window frame including cutting, welding & wastage including supply of all materials, labours, T&P etc required foroper completion of the work. (Sch No. 503 A) |
| 12 | MS of iron work of small sizes and section such as MS Grills & staircase railings including supply of all materials, labours, T&P etc required for proper completion of the work. (Sch No 502 A) |
| 13 | MS of iron work of small sizes and section such as Z-section including supply of all materials, labours, T&P etc required for proper completion of the work. (Sch No 502 B) |
| 14 | 12 mm thick cement plaster in single coat of fair side wall with 1 : 4 cement & coarse sand including all labours, materials, T&P etc all complete. (PWD SI No. 13.11 C) |
| 15 | Add extra for plaster over roughface of one brick thick wall. (Sch No. 13.13 E) |
| 16 | 2 cm thick cement plaster in dado or skirting in 1:2 consisting of one part of cement & two parts of aproved coarse sand laid in panels finished with 3mm floating coat of neat cement including supply of all materials, labours, T&P etc all complete. (Sch No 13.08) |
| 17 | Cutting groove in plaster 1 cm wide & 1 deep by using special tools including supply of all tools and plants complete. (PWD sch. 18.18) |
| 18 | Making drip course in sunshade or facia as per direction of Engineer in-charge including all materials, labours, T&P etc all complete. (Pwd Sch 598) |
| 19 | Supply and fixing of 35mm thick flush door commercial quality confirming to IS 2202 Part I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles sprngs fitting with necessary screws complete. (SI No 470) |
| 20 | Approximate cost of ISI Marked oxidized iron fittings with screws for door and windows etc. (SI No. 473) |
| 21 | Providing and fixing of 5mm thick glass panes with putty etc all complete. (Pwd Sch 18.03) |
| 22 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (Kanpur SOR Chapter No. 27 item 3 DAR ref to 22.7.1) |
| 23 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 24 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 25 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 an |
| 26 | d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 27 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. |
| 28 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1.2.4 (1 cement . 2 coarse sand . 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1.3 (1 cement . 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (Pwd Sch 18.24) |
| 29 | Supply & fixing of Kota stone in flooring 20mm thick and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given and even shade with 12mm base coat of 1:2 cement and coarse sand mortor and polished by hand or machine and finally finished wihench manson polish or other approved polish including supply of all materials, labours, T&P etc required for proper completion of the work. (Pwd Sch 14.24) |
| 30 | Same as above item No. 24 but 10 to 12 mm thick Kota stone tiles in skirting or dado etc all complete. (Pwd Sch 14.25) |
| 31 | 40 mm thick Cement concrete flooring with 1:2:4 of 1 cement 2 coarse sand & 4 stone grit of 10-20 mm size (SI No. 605) |
| 32 | Providing and applying white cement based putty of average thickness of 1 mm of approved brand and manufacturer over the wall surface to prepare the surface even and smooth including cost of materials, labours T&P etc all complete. (Kanpur PWD SchChapter-16 item 13) |
| 33 | Distempering with 2 coat with oil bound distemper of approved brand and manufacturer of required shade including a priming coat with cement primer of approved brand and manufacturer such as Burger, asian etc (PWD S N 649+651) |
| 34 | Wall painting (two coat)with plastic Emulsion paint of approved brand and manufacture on wall surface to give an even shade including thoroughly brusing, clean all dirt, grease, loose pieces and prepaired smooth. (Sch No.15.15+15.16) |
| 35 | Painting on new iron work with one coat of ready mixed primer and two coats of approved superior quality ready mixed paint including all materials, labours, T&P etc all complete (Pwd Sch 641+642) |
| 36 | Supply and fixing of 100mm dia PVC Rain water pipe fix with MS clamp on wall including all materials, labours, T&P etc all complete. (Kanpur SOR Ch. 19 item No 3) |
| 37 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 8 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (AR) |
| 38 | Electrification : |
| 39 | Wiring Point for light 1.5 Sqmm FR PVC insulated multistrand single core copper conductor cable in heavy gauge PVC conduit with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit (Sch. 131-C & 187-A) |
| 40 | Wiring Point for fan/fresh air Fan (Light duty exhaust Fan) with 1.5 sqmm FR PVC conduit with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit (Sch. Nos.. 133-C & 187-A) |
| 41 | Wiring Point for plug 1.5 sqmm FR PVC insulated multistrand single wire copper conductor cable but in PCV conduit with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit (Sch. Nos.. 134-C & 187-C) |
| 42 | S/F of Power Plug with 15 amp/250 Vatt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mmx 100 mmx 50 mm size with pheNos.lic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washe Sch no 1139-A |
| 43 | Supply and wiring of sub main with two Nos.. FR PVC insulated 1100 v. grade multistrand single core copper conductor cable in 20mm dia |
| 44 | a)2.5 sqmm (1304-C) |
| 45 | b)4.0 sqmm (216-C) |
| 46 | c)10.00 sqmm (273 -C) |
| 47 | S/F of 6 amp to 32 amp MCB (10 KA) (Sch. Nos.. 1002) |
| 48 | S/F of Electronic fan dimmer, 300/400 w ISI marked… complete(Sch. No. 1203-B) |
| 49 | S/F of 36 watt to 46 watt LED square fitting ….. Completed (Sch no 1406) cat AAA |
| 50 | S/F of 1200 mm Sweep Ceiling Fan made with double ball bearing…complete item (Make Khaitan, Polar, Bajaj etc.) |
| 51 | S/F of LED Tube light with battern suitable for up to 1x22 watt LED tube light fitting including tube on surface complete in all respect …. Completed (Sch No. 1413) |
| 52 | S/F of 63 amp 4 pole Isolator...... Complate Sch no-1007-B CAT-A |
| 53 | S/F of surface/Flush mountingSPN DB Box (Cosumer Unit ) Withadditional metal doorfor incomming butwithout MCB completed in all respect |
| 54 | a) 12 way (sch. No. 1025-A) |
| 55 | S/f of 400 mm wall fan …..completed(Make Khaitan, Polar, Bajaj etc.) |
| 56 | S/F of 300 mm Fresh air fan .. Complete Make Bajaj, Khaitan, Polar. |
| 57 | Wiring point for HP MV/SV lamp in PVC conduit 1.5 sqmm FRPVC multistrand copper conductor cable… complete (Sch. 136-C) |
| 58 | supply &fixing of 75 watt to 90 watt LED Street light fitting …complate sch no- 1425 |
| 59 | Laaabour cess 1%` |