Major Repair-Imp. And Major Repair Of Puhc Dispensary Naraina In Ward No.139 Naraina / Kbz, Dsr 2018 And Approved Items. 1 Rmc Work 2 1.1.1_22:Disposal Of Materials By Mechanical Transportincluding Loading , Unloading And Stacking Lime , Moorum, Buildingrubbish For Lead 22 Km 3 15.3:Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. 4 15.5:Extra For Cutting Reinforcement Bars Manually / By Mechanical Means In R.C.C. Or R.B. Work ( Payment Shall Be Made On The Cross Sectional Area Of R.C.C. Or R.B Work ) As Per Direction Of Engineer-In-Charge. 5 15.26:Demolishing Brick Tile Covering In Terracing Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. 6 15.56:Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 7 14.5.1:Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty :Float Glass Panes Of Nominal Thickness 4 Mm ( Weight Not Less Than 10Kg / Sqm ) 8 14.54.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To An Give Even Shade:One Or More Coats On Old Work 9 14.72:Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side, Upto Seven Story Hight Made With 40 Mm Dia. M.S. Tube 1.5 M Centre To Centre, Horizontal & Vertical Tubes Joining With Cup & Lock System With M.S. Tubes, M.S. Tube Challies, M.S. Clamps And M.S. Staricase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For The Required Duration As Approved And Removing It There After. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connection With The Building Etc Wherever Required For Inspection Of Work At Required Location With Essential Safety Features For The Workmen Etc. Complete As Per Directions And Approval Of Engineer- In Charge.The Elevational Area Of The Scaffolding Shall Be Measured For Payment Purpose.The Payment Will Be Made Once Irrespective Of Duration Of Scaffolding. Note:- This Item To Be Used For Maintenance Work Judicially, Necessary Deduction For Scaffolding In The Existing Item To Be Done . 10 14.75:Repair To Plaster Of Thickness 12Mm To 20 Mm In Patches Of Area 2.5 Sqm And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing Plastering The Wall Surface With White Cement Based Polymer Modified Self Curing Mortar, Including Disposal Of Rubbish, All Complete As Per The Direction Of Engineer-In-Charge. 11 5.1.2:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 12 5.9.3:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 13 5.22.1:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars 14 13.4.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand ) 15 11.41A.1.1:Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Size Of Tile 600 X 600 Mm 16 13.21:Extra For Providing And Mixing Water Proofing Material In Cement Plaster Work In Proportion Recommended By The Manufacturers. 17 13.72:Washed Stone Grit Plaster On Exterior Walls Height Upto 10 Metre Above Ground Level, In Two Layers, Under Layer 12 Mm Cement Plaster 1:4 ( 1 Cement : 4 Coarse Sand ) , Furrowing The Under Layer With Scratching Tool, Applying Cement Slurry On The Under Layer @ 2 Kg Of Cement Per Square Metre, Top Layer 15 Mm Cement Plaster 1:1 / 2:2 ( 1 Cement : 1 / 2 Coarse Sand : 2 Stone Chipping 10 Mm Nominal Size ) , In Panels With Groove All Around As Per Approved Pattern Including Scrubbing And Washing The Top Layer With Brushes And Water To Expose The Stone Chippings, Complete As Per Specification And Direction Of Engineer-In-Charge ( Payment For Providing Grooves Shall Be Made Separately ) . 18 13.26:Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 19 13.85.3:Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Walls Surface Having Voc Content Less Than 50 Grams / Litre 20 10.25.2:Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 21 13.86:6 Mm Plaster On Cement Concrete Or Reinforced Cement Concrete Work With White Cement Based Polymer Modified Self Curing Mortar Of Approved Make As Per The Direction Of Engineer-In-Charge. 22 6.4.1:Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In:Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 23 8.31:Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By EngineerIn-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 24 11.15.1:Crazy Marble Stone Flooring, Including Filling The Gaps With Light Shade Pigment With White Cement Marble Powder Mixture ( 3 Parts Of White Cement : 1 Part Of Marble Powder ) By Weight In Proportion Of 4:7 ( 4 Cement Marble Powder Mix : 7 White, Black Or White And Black Marble Chips Of Sizes From 1 Mm To 4 Mm Nominal Size By Volume ) , With Under Layer 25 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) , Including Rubbing, Polishing And Cement Slurry Etc. Complete:18 Mm Thick Crazy Marble Stone White, Black Or As Specified 25 18.9.7:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching , Refilling & Testing Of Joints Complete As Per Direction Of Engineer- In-Charge.External Work65 Mm Nominal Dia Pipes 26 18.10.1:Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work- Exposed On Wall15 Mm Dia Nominal Bore 27 18.7.1:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge.Internal Work - Exposed On Wall15 Mm Nominal Dia Pipes 28 18.7.2:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge.Internal Work - Exposed On Wall20 Mm Nominal Dia Pipes 29 18.8.1:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15 Mm Nominal Dia Pipes 30 18.9.2:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching , Refilling & Testing Of Joints Complete As Per Direction Of Engineer- In-Charge.External Work20 Mm Nominal Dia Pipes 31 18.15.1:Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore 32 18.15.2:Providing And Fixing Brass Bib Cock Of Approved Quality :20 Mm Nominal Bore 33 18.16.1:Providing And Fixing Brass Stop Cock Of Approved Quality :15 Mm Nominal Bore 34 18.16.2:Providing And Fixing Brass Stop Cock Of Approved Quality :20 Mm Nominal Bore 35 17.2.1:Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 36 17.4.1:Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I. Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required:One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern 37 17.7.4:Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap