Tender For Supply Installation Testing Commissioning Of Medical Gas Piping System (Mgps) For Taluk Hospital Kundara, kollam-Kerala

Kerala State Electricity Board-KSEB has published Tender For Supply Installation Testing Commissioning Of Medical Gas Piping System (Mgps) For Taluk Hospital Kundara. Submission Date for this Tender is 31-07-2023. Medical Gas Tenders in kollam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

38565490
Corrigendum : Tender For Supply Installation Testing Commissioning Of Medical Gas Piping System (Mgps) For Taluk Hospital Kundara
Open Tender
Indian
Kerala
kollam
31-07-2023

Tender Details

Supply Installation Testing Commissioning Of Medical Gas Piping System ( Mgps ) For Taluk Hospital Kundara

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jul-2023 Corrigendum 1 Technical Bid 31-07-2023
2 29-Jul-2023 Corrigendum 2 Technical Bid 31-07-2023

Key Value

Document Fees
INR 5900 /-
EMD
INR 50000.0 /-
Tender Value
INR 1.08 Crore /-

BOQ Items

Work Name : Supply, Installation, Testing & Commissioning of Medical Gas Piping System (MGPS) for Taluk Hospital, Kundara
Sl. No. Item Description
1MANIFOLD AND PLANT ROOM - OXYGEN SYSTEM
2od68094/2023_2024 : Supply, installation testing and commissioningof AutomaticOxygen Control Panel with minimum flow rate of 1600 LPM with liquid oxygen connectivity, suitable for 2x10 manifold system Fully complyingwith ISO 10524-2, ISO 7396-1:2007/HTM02-01 as per technical specifications. The cylinders shall not be included in the quoted price.
3od68115/2023_2024 : Supply,testing and commissioningof Oxygen Manifold- 2 banks x10 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.
4od68120/2023_2024 : Supply,testing and commissioningof Cylinder EmergencyOxygen<br>Manifoldwith high flow regulator- 1 Bank X5 Cylinders
5od69963/2023_2024 : Supply,testing and commissioningof Oxygen Manifold- 2 banks x10 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.
6Nitrous oxide system
7od68252/2023_2024 : NITROUS OXIDE SYSTEM: Supply,testing and commissioningof automaticN2O control panel complete set with inlet and outlet connectors suitable for 2x2 manifold system with minimum flow rate of 600 LPM, fully automatic control panel for both sides with brass hosing and suitable connectors. ½” BSP (M) thread.
8od68494/2023_2024 : Supply,testing and commissioningof Cylinder EmergencyNitrous oxide Manifoldwith nesessary regulating system - 1 bank x 2 cylinders as per technical specifications.
9od68495/2023_2024 : Supply,testing and commissioningof Nitrous Oxide Manifold- 2 banks x 2 cylinders.as per technical specifications. The cylinders shall not be included in the quoted price.
10CARBON DIOXIDE SYSTEM
11od68505/2023_2024 : Supply,testing and commissioningof Cylinder CO2 Manifold- 1 bank x 2 cylinder with a high flow regulator with gauges and safety valves complete with all accessoriesetc. as required complete as per specification
12od68506/2023_2024 : CARBON DIOXIDE SYSTEM: Supply,testing and commissioningof semi automaticCO2 control panel complete set with inlet and outlet connectors for automatic for both sides with brass housing and suitable connectors.½” BSP (M) thread.
13MEDICAL AIR SYSTEM
14od68563/2023_2024 : MEDICAL AIR SYSTEM: Supply,testing and commissioningof Compressed air plant complete with - 2 compressors, each compressorshould have minimum free air delivery of 1600 LPM @10bars, 1 air receiver tank of minimum 1500 ltr capacity, filtration and dryersystem to ensure medical air quality as per HTM standards (each compressor module should include an inline filter with particle retention of 10 microns), NRV, pressure reducing station,automatic drain valves,pressure guages,ball valves, electrical control panel including circuit breakers, starters, pressure switches, timers, as per technical specifications
15VACCUM PLANT
16od68766/2023_2024 : VACUUM PLANT: Supply,testing and commissioningof Vacuum plant complete with 1 vacuum pump and one as standby, each vacuumpump should have minimum free air aspiratedof 2000 LPMbetwen 570 mmHg and 720 mm Hg.min, vaccum receiver tank of minimum 1500 ltr capacity,bacteria double filter, valves,pressure guages,NRV, electrical control panel including circuit breakers,pressure switches, timers,ball valves etc as per technical specifications.
17Motor control
18od68795/2023_2024 : Supply, Installation , testing and commissioning of motor control center consisting of 125 Amp 4P isolator incomer, phase indicators ,outgoing of 5 nos 63 TP D curve MCB ,starters, push button, motor protection devices, instrumentation, control cabling for Air compressor & vaccum Pump systemetc as per technical specification
19PIPE LINE SYSTEM
20od68799/2023_2024 : Supply,installation testing and commissioningof Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specifications.42 mm x 1.2 mm thick Copper pipe
21od68800/2023_2024 : Supply, installation testing and commissioningof Copper pipe: as per standard BS:EN13348:2008 /astm B819 standards, solid drawn, seamless, deoxidized, non-arsenical, half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards .All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specification -12mm x 1 mm thick copper pipe
22od68801/2023_2024 : Supply, installation testing and commissioningof Copper pipe: as per standard BS:EN13348:2008 /astm B819 standards, solid drawn, seamless, deoxidized, non-arsenical, half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards. All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specifications.54 mm x 1.2 mm thick Copper pipe
23od68802/2023_2024 : Supply, installation testing and commissioningof Copper pipe: as per standard BS:EN13348:2008 /astm B819 standards, solid drawn, seamless, deoxidized, non-arsenical, half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards. All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specifications.28 mm x 0.9 mm thick Copper pipe
24od72593/2023_2024 : Supply,installation testing and commissioningof Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications. 22 mmx 0.9 mm thick Copper pipe
25od74352/2023_2024 : <br>Supplyof Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards. All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specification15 mm x 0.9 mm thick copper pipe
26GAS OUTLETS
27od68806/2023_2024 : Supply,Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. Venturi type AGSS outlets conformingto EN ISO 9170-2
28od68807/2023_2024 : Supply,Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. CO2 Outlets with Probes
29od68808/2023_2024 : Supply,Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. Vac Outlets with Probes
30od68809/2023_2024 : Supply,Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. Air (7 bar) Outlets with Probes
31od68810/2023_2024 : Supply,Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (4 bar) Outlets with Probes
32od68894/2023_2024 : Supply, Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. N2O Outlets with Probes
33od68895/2023_2024 : Supply,Installation , testing and commissioningof Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications.O2 Outlets with Probes
34Master Alarm panel
35od68907/2023_2024 : Supply,testing and commissioningof Master Plant Alarm Panel ,Complies with HTM 02-01/ISO<br>7396-1 Standards. Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 25 point. Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red-light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is created, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with EMC standards. Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. Each panel shall display and/or input of multi point alarms,including all necessary cabling between mater alarm and floor panels. The master alarm must be able to monitor the following source alarm conditions. as per technical specifications.Master Plant Alarm Panel ,Complies with HTM 02-01/ISO
36Area valve +alarm unit
37od68925/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications.7 gas- 2 O2,IM air,1 N2O, 1 CO2, 1 s air, 1 vac
38od68926/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications.5 gas - 2 O2, 1M air, 2 Vac
39od68927/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications.3 gas - 1 O2, 1M air, 1 Vac
40od68928/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications.2 gas - 1 O2, 1 Vac-
41BALL VALVES
42od71043/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complyingwith HTM 02-01/DIN, as per technical Specifications-42mm
43od71184/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complyingwith HTM 02-01/DIN, as per technical Specifications 54 mm
44od68961/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complyingwith HTM 02-01/DIN, as per technical Specifications28mm
45od68962/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complyingwith HTM 02-01/DIN, as per technical Specifications
46od68963/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complyingwith HTM 02-01/DIN, as per technical Specifications-15 mm
47OXYGEN GAS CYLINDER
48od69249/2023_2024 : Supply,testing and commissioningof D type CO2 Gas filled Cylinder having as per technical specification.D type CO2 Gas filled Cylinder
49od69250/2023_2024 : Supply,testing and commissioningof D type Nitrous Oxide Gas filled Cylinder as per technical specification.D type Nitrous Oxide Gas filled Cylinder
50od68959/2023_2024 : Supply, testing and commissioningof class D type Oxygen Gas filled Cylinder etc in complete as per technical specification.
51BED HEAD PANELS
52od69297/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be divided into different sections to segregate power, data and medical gas chamber suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge.-Bed head panel as above with 5 Gas outlet
53od69298/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be divided into different sections to segregate power, data and medical gas chamber suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge. Bed head panel as above with 2 Gas outlet
54BPC
55od69355/2023_2024 : Supply, Installation, testing and commissioning of High Pressure Antistatic Hose with color coded.
56od69356/2023_2024 : Supply Installation of Theatre Vacuum unit with trolly and 2000 ml collection jar as per technical.
57od69357/2023_2024 : Supply Installation of Ward vacuum unit with 600 ml collection jar asper technical specification.
58od69358/2023_2024 : Supply Installation of BPC Oxygen Flow meter as per technical specification.