Tender For Spl Repair To Bldg No P-19, Replacement Of Asbestos Sheets With Galvalume Sheet And Other Rev Works At Naa Under Ge (North) Tezpur, tezpur-Assam

Military Engineer Services-MES has published Tender For Spl Repair To Bldg No P-19, Replacement Of Asbestos Sheets With Galvalume Sheet And Other Rev Works At Naa Under Ge (North) Tezpur. Submission Date for this Tender is 05-08-2023. Building Work Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

38550321
Corrigendum : Tender For Spl Repair To Bldg No P-19, Replacement Of Asbestos Sheets With Galvalume Sheet And Other Rev Works At Naa Under Ge (North) Tezpur
Open Tender
Indian
Assam
tezpur
05-08-2023

Tender Details

Spl Repair To Bldg No P-19, Replacement Of Asbestos Sheets With Galvalume Sheet And Other Rev Works At Naa Under Ge ( North ) Tezpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 89000.0 /-
Tender Value
INR 44.50 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO BLDG NO P-19, REPLACEMENT OF ASBESTOS SHEETS WITH GALVALUME SHEET AND OTHER REV WORKS AT NAA UNDER GE (NORTH) TEZPUR.
Sl. No. Item Description
1Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and as directed.
2M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
3S&F pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet 0.50 mm thick of and colour having tensile strengh of 550 Mpa as in ridge, eaves sheet/board covering, valley gutter or of similar type, fixed with self tapping screws with bitumen washer to truss members of any material, complete all as specified and as directed.
4M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
5S & F second class hard wood plain fillets square, rectangular or triangular in section, clean sawn secured with nails, cross sectional area exceeding 13Sq.cm but not exceeding 25 Sq.cm complete all as specified and as directed.
6S&F 2nd class Hard wood scanttlings, wrought in any position for framed work jointing wirh nails, screws, nut bolt etc. including necessary supports to existing truss including Dismantling of timber scanttlings 40 Sqcm & over in section, in any position for framed workcomplete all as specified and directed.
7Supply and Fix exposed GI powder coated snap grid frame work for false ceiling in flat or in sloping , of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with 4mm dia GI wire as suspender and including 4mm thick decorative pre -painted non asbestos board (E-Board) in false ceiling including fixing arrangement from steel/wooden truss of any type including dismantalling of existing false ceiling complete all as specified and directed. (Make: Eternit, Everest or equivalent)
8S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality "A") complete all as specified and directed.
9M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote complete all as specified and as directed.
10Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
11Preparation of old or previously untreated steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
12Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
13Taking down and refixing in same opening wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
14Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
15Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
16Material and labour for brick work with sub-class "B" old size bricks of class designation 75, straight or curved on plan exceeding 6m mean radiusbuilt in cement mortar (1:6) including dismantling of existing brick work built in cement mortar complete in all respect as specified and directed.
17M & L for brick work with sub class "B" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
18M & L for plain, solid, straight chowkhats and frames made out of 2nd class timber species of group I and durability class II as per IS 12896: 1990 and first grade as per IS 4021: 1995, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
19M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer-in-charge.
20S&F framed work such as grills, gratings,etc with ends of bars shouldered and /or riveted, or forged into spikes framed guard bars barred iron doors , laddersand similar work conforming to Fe 410-0 or FE310-0 complete all as specified and directed.
21M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate as in floor 25 mm thick finished even and fair complete all as specified and directed.
22M & L for coloured non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour laid over and included 15 mm thick screed bed in cement mortar (CM) 1 :6, complete all as specified and as directed.
23M&L for coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile colour complete in all respect as specified and directed.
24M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed.
25S&F for  coloured glazed pre coated chequered cement concrete tiles of any shape and size,20-25mm thick with grey cement with pigment,; set jointed and pointed in neat cement slurry with pigment in floors including over 15mm thick screed bed in CM 1:4 and dismantalling of existing tiling with screed bedding complete in all respect as specified and directed.
26M & L for rendering15mm thick cement plaster in cm 1:4 on fair faces brick or concrete surfacesusing water proofing compound of wall (WPC added only 5 mm thick plaster) including finished even and smooth without using extra cement complete all as specified and as directed.(WPC Shall be paid and meassured separately)
27M& L for rendering/plastering 15 mm thick in cement mortar 1:6 on faces of brick or concretesurfaces and finished the surface even and smooth without using extra cement complete in all respect as specifified and directed.
28Supply only integral water proofing compound complete all as specified and as directed.
29M & L second class hardwood 35 mm thick, timber species of super group and durability class II as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, cham104fered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge./*9-6374
30Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
31S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
32S & F flush door shutters, 35 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
33S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
34S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
35S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
36S & F mild steel sliding door bolts, type I (plate type), size 250 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
37S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
38M&L for plinth protection or in foot path of 75 mm thick of cement concrete using type C-1, 1:3:6 (using 20 mm nominal size crushed and graded stone aggregate) in alternate penals and finished fair and even complete in all respect as specified and directed.
39M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, 40 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
40S&F Plastic dividing strips, 1.5mm thick of size 10/38 mm complete all as specified and directed.
41M&L for preparation of old decorated plastered surface of wall after complete removal of existing treatment and applying two coats of weather coat over 2 mm thick wall care putty (in two layers) over a coat of primer including preparation of surface, complete in all respect as specified and directed.
42Material and labour for complete removal of existing treatment on wall and applying two coats of oil bound distemper and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 2mm thick (in two layers), wall care putty complete in all respect as specified and directed.
43M&L for preparation of newly plastered surface of wall and applying two coats of weather coat over 2 mm thick wall care putty over a coat of primer including necessary preparation of surface, complete in all respect as specified and directed.
44Material and labour for preparation of newly undecorated plastered surface of wall and applying two coats of oil bound distemper and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 2mm thick (in two layers), wall care putty complete in all respect as specified and directed.
45M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
46Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
47Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
48M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
49M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
50S&F mild steel work in plates (plain) channels, squares cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment.using Fe 410-W (Gde E-250) quality A complete in all respect as specifified and directed.
51M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
52M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in flooring finished even and smooth without using extra cement complete all as specified and as directed.
53Providing and laying 60 mm thick coloured glazed rubber mould, pre-coated interlocking or without interlocking paver block of any shape and size conforming to IS 15658-2006 with upto date amendments, M-35 Grade with grey cement with pigment laid over river bed fine sand etc complete all as specified and directed. (Note : River bed sand shall be measured and paid seperately) sample shall be approved by GE.
54M & L for brick work with sub class "B" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
55M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair without using extra cement including necessary expansion joint and filling compoundas in plinth protectionall as specified and as directed.
56Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
57Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
58Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
59Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
60M & L for point wiring with 1.5 sqmmFRLSH, PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade (MMS ISI) of size not less than 20 mm dia(or as site requirement) concealed in wall/over ceiling, pressed steel concealed terminal boxes of required size and with top cover 3 mm thick of plastic laminated sheet of reqd colour, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 1.5 sqmm FRLSH PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dollyfor light / fan/ bell point controlled by one switch. Note:- (i) Cost of PVC conduit, steel terminal boxes, plastic laminated sheet cover etc; are deemed to be included in the quoted rate. (ii) M&L for cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.
61All as per item 60 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed.
62All as per item 60 above but for 3 pin 15 Amps switch socket combination on independent board with 4.0 sq mm copper cable complete all as specified and directed.
63S & Fswitch socket combination out let 2 in one/3 pin , 5/6 Amps, flush type 240 volt , AC 50 Hz complete all as specified and directed. (Make :- Havells Cat no/SAP code - AHETOXG202 or equivalent in Legrand / Schneider)”
64S & Fswitch socket combination out let 2 in one/6 pin , 6/16 Amps,flush type 240 volt , AC 50 Hz complete all as specified and directed. (Make :- Havells Cat no/SAP code - AHETOFG202 or equivalent in Legrand / Schneider
65S & F switch piano 5/6A one way ,240 volt , AC , 50 Hz flush type complete all as specified and directed.(Make - Havells Cat no/SAP code:- AHESEXW061 of REO or equivalent in Legrand/schneider
66S & F step type electronic fan regulator , capacitor type , 100/120 watt , 240 watt , 50 Hz , single phase , flush type complete all as specified.(Make :- Havells Cat no/SAP code – AHERFXW002 or equivalent in Legrand / Schneider)
67S & F ceiling rose 6A ,240 volt , surface type , intended to support mechanical load by means of flexible coard having provision for the connectionof switch wiring , polycarbonate typethree terminals complete all as specified and directed.(Make :- Havells Cat no/SAP code – AHEEUXW002 or equivalent in Legrand / Schneider)
68M&L for sheet metal enclosure MCB DBs TPN , 4 way 415 V, with 100 A rated copper bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. (Make:- Legrand series 5076 70 to 76 or equivalent in L & T / Schnieder)
69Supply and draw submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduitincluding 6 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.
70M&L for sheet metal enclosure MCB DBs SPN , 8 way 240 V, with 100 A rated copper bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. (Make:- Legrand series 5076 10 to 15 or equivalent in L & T / Schnieder)
71M & L for MCB SP 6-32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4085 87 to 4085 95 or equivalent in L & T / Schnieder)
72M & L for MCB SPN 32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4086 17 or equivalent in L & T / Schnieder)
73M & L for reparing/rewinding of u/s ceiling fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and painting one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different location and connection complete from ceiling rose with new flexible chord of copper of suitable size, testing commissioning after completion of the work.[Note:- (1) Rewinding of fans included in this quoted rate.(2) U/s fan(ceiling or exhaust) will be issued by department /user].
74M & L for reparing/rewinding of u/s exhaust of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and painting one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different location and connection complete from ceiling rose with new flexible chord of copper of suitable size, testing commissioning after completion of the work.[Note:- (1) Rewinding of fans included in this quoted rate.(2) U/s fan(ceiling or exhaust) will be issued by department /user].
75S&F in replacement LED Tube light luminaires, 22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable offrom connector and ceiling rose, complete all as specified and directed. (Make :- Philips model SmartBright or equivalent in Wipro / Crompton)
76Supply & Fix LEDwall security lights 30 watt new generation energy saving environmental friendly made up of pressure die cast aluminium housing with high efficiency ,IP 66 protectionwith necessary brackets (made out of 20/25mm bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls complete all as specified and directed. (Make:- Philips Cat no-BRP046 LED 30 CW MR S1 PSU GR or Equivalent in Wipro/Crompton)
77S & F in replacement LED recess mounted (2"x2" size flat panel) luminaire which provide soft light and glare free symmertical illumination suitable for armstrong/grid ceiling of 36Watt,(Lumen output not lessthan 3600) complete all as specified and directed.Make Philips Smart Glow(Cat No:- RC383B LED 36S-6500 PSU OD WH PIR).
78Supply and fix 50 Watts LED flood light made up of pressure die cast aluminium housing with toughened glass with efficacy > 110/120 LPW , 10 KV SPD (surge protection device) , IP 66 protection , input voltage 140 - 270 voltAC , mounting/fixing arrengement as required at site etc complete all as specified anddirected by Engineer-in-Charge. (Note:- Rate of GI/iron pipe of suitable length/size as required at site / welding work or fabrication included in quoted rate. (Make:- or Crompton Cat Part No.- CFS-504-50-57-60D-SL-GL-NSG or Philips Cat Part No:- BVP103 LED50 CW FG GR PSU or equivalent in Wipro.
79M & L for Earthingwith galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4 mm dia galvanised iron or steel wire all as shown in Plate No. 2 ( SSR Part-1) to the earthing test point all as specified and indicated , necessary excavation any type of soil, CI chamber cover 10 mm with 6 mm rod , wire mess, funnel, test point, 20 mm dia GI protection pipe medium gradeetc complete and testing on completion all as specified and directed by Engr-in-charge (4 mm wire lead upto 7.5 RM will be included in the item rate .(Note :- Fresh agriculture soil / black dirt or soil with a high organic conten will be used for filling the dug as required when rocky /sandy soil found at site to achieve the desired resistance from out side without any extra cost.