Public Works Department-PWD has published Tender For Vertical Extension Of Food Processing Building At Tit Campus For Proposed National Law University, Tripura/Sh. Building Portion Including Water Supply And Sanitary Installation.. Submission Date for this Tender is 05-08-2023. Building Work Tenders in mohanpur Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SUB-HEAD : EARTH WORK |
2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. - All kinds of soil |
3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
4 | SUB-HEAD : CEMENT CONCRETE WORK |
5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level:(i) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size) |
6 | SUB-HEAD : RCC WORK |
7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
9 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.(i) Thermo-Mechanically Treated bars of grade Fe-500D or more |
10 | Centering shuttering including struttings, propping etc. and removal of form work for: (iii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
11 | Centering shuttering including struttings, propping etc. and removal of form work for:(iv) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
12 | Centering shuttering including struttings, propping etc. and removal of form work for:(v) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
13 | Centering shuttering including struttings, propping etc. and removal of form work for: (vi) Stairs (excluding landings) except spiral-staircases with wooden plank |
14 | Centering shuttering including struttings, propping etc. and removal of form work for:(viii) Edges of slabs and breaks in floors and walls under 20 cm. wide |
15 | Centering shuttering including struttings, propping etc. and removal of form work for:(ix) Weather shade, Chajjas, corbels etc., including edges. |
16 | SUB-HEAD : BRICK WORK |
17 | First class brick work in foundation and plinth including cost of all materials as required complete. (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
18 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete. (i) In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
19 | Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
20 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-(i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
21 | SUB-HEAD : WOOD WORK |
22 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : (i) Local Teak wood |
23 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters.(i) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. (i) Fixed to openings /wooden frames with rawl plugs screws etc. |
25 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
26 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(ii) 250 x 16 mm |
27 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :(ii) 250 x 10 mm |
28 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :(i) 125 mm |
29 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. (i) Single rubber stopper |
30 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
31 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in- charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
32 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
33 | Providing and fixingfan clamp type-Iof 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete. |
34 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
35 | SUB-HEAD: ALUMINIUM WORK |
36 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-(i) For fixed portion of approved quality:- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
37 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-(ii) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
38 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- (i) With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
39 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- (ii) With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm ) |
40 | Providing and fixing stainless steel (SS 304 grade) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:- (i) 255 x 19 mm |
41 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality completeas per direction of Engineer-in-charge:-(i) Anodised aluminium of grade AC 15. |
42 | Providing and fixing 100 mm brass locks ( best make of approved quality ) with 6 levers without pair of handles for aluminium doors including necessary cutting and making good etc. completeas per direction of Engineer-in-charge. |
43 | SUB-HEAD : FLOORING AND SKIRTING WORK |
44 | Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishingcomplete.(i) 18mm thick Marble Stone - Raj Nagar Plain marble |
45 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. (i) 8mm thick Rajnagar marble tiles (polished) |
46 | Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) ofapproved make in all colours, shades of any size asapproved by Engineer-in-charge in skirting, risers ofsteps and dados, laid over 12 mm thick bed of cementmortar 1 : 3 (1 cement : 3 fine sand) jointed withordinary cement slurry including pointing with whitecement mixed with pigment of matching shade complete. |
47 | Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete.(i) Mat Finish Tiles - Ceramic Tiles 1st quality 400 x 400mm in all shades and designs |
48 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (i) Double charged Stainfree vitrified tiles - Size of tile 60 x 60 cm |
49 | SUB-HEAD : ROOFING AND CEILING WORK |
50 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes (working pressure 4 kg/cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion: (i) Single socketed pipe - 110 mm OD |
51 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS:13592TypeAincludingjointingwith sealringconformingtoIS: 5382 leaving 10 mm gap forthermalexpansion: (i) Coupler - 110mm |
52 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS:13592TypeAincludingjointingwith sealringconformingtoIS: 5382 leaving 10 mm gap forthermalexpansion: (ii) Single equal tee without door - 110 x 110 x 110 mm |
53 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS:13592TypeAincludingjointingwith sealringconformingtoIS: 5382 leaving 10 mm gap forthermalexpansion: (iii) Single equal tee with door - 110 x 110 x 110 mm |
54 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS:13592TypeAincludingjointingwith sealringconformingtoIS: 5382 leaving 10 mm gap forthermalexpansion: (iv) Bend 87.5 - 110mm |
55 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS:13592TypeAincludingjointingwith sealringconformingtoIS: 5382 leaving 10 mm gap forthermalexpansion: (v) Plain shoe - 110 mm |
56 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete. (i) 110mm |
57 | Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete. (i)110 mm |
58 | Supply & installation of pre-painted Galvalume sheets forroofing/ cladding (size,shape andpitch of corrugationas approved by Engineer-in-charge) in 550mpasteelgrade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Aland 1.5%Siliconconfirming to ASTM A792/ A792Mand AS1397, Alloy coating AZ150/ AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25micronsminimumto avoid scratcheswhile transportation and shouldbe supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.60 mm thickness |
59 | Supply & installation roofing accessories in of pre-painted Galvalume sheets 550mpa steel steel grade, made out of Cold rolled steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to AASTM A792/ A792M and AS1397, Alloy coating AZ150/ AZ70, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protectiveguardfilmof 25 micronsminimumto avoid scratches whiletransportation. Sheet should have protective guard film of 25 microns minimum to avoid scratches whiletransportation. The sheet shall be fixed using self drilling / self tapping screws withEPDMwasherscomplete for Ridges/ Valley/ Gutter/ Flashing of width 610mm: 0.6 mm thickness |
60 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Gridof hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
61 | SUB-HEAD : STEEL WORK |
62 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
63 | Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- i) In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete. |
64 | SUB-HEAD : FINISHING WORK |
65 | 12 mm cement plaster of mix. (ii) In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
66 | 15 mm cement plaster on the rough side of single or half brick wall of mix:(i) In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
67 | 6 mm cement plaster of mix:(i) In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) |
68 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
69 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : Two or more coats on new work |
70 | Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : (i) New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
71 | Applying priming coat: [Payment shall be made after submission of Test Certificate issued by the Manufacturer](i) With ready mixed pink primer of approved brand and manufacture on wood work ( hard & soft wood ). |
72 | Applying priming coat: [Payment shall be made after submission of Test Certificate issued by the Manufacturer](ii) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
73 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: (i) Two or more coats on new work |
74 | SUB-HEAD:WATER PROOFING WORK |
75 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :(i) Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
76 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with(ii) Cement mortar 1:4 (1 cement : 4 fine sand ) |
77 | SUB-HEAD : SANITARY WORKS |
78 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : (i) White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
79 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :(i) Range of four urinal basins with 10 litre white P.V.C automatic flushing cistern. |
80 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
81 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively. |
82 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:(i) Flat back wash basin of size 550x400mm. |
83 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (i) Semi rigid pipe - 32 mm dia |
84 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (ii) Flexible pipe - 32 mm dia |
85 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
86 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
87 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms |
88 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.(i) 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms |
89 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
90 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand): (i) 100 mm dia. |
91 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382leaving10mmgapforthermalexpansion: (i) Single socketed pipe - 110 mm OD |
92 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: (i) Coupler - 110mm |
93 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: (ii) Single pushfit Coupler - 110mm |
94 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: (iii) Single equal tee without door - 110 x 110 x 110 mm |
95 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: (iv) Single equal tee with door - 110 x 110 x 110 mm |
96 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: (v) Doubleequal junction of required degreewithout door - 110 x 110 x 110 mm |
97 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: (vi) Doubleequal junction of required degreewith door - 110 x 110 x 110 mm |
98 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion:(vii) Bend 87.5 - 110mm |
99 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion:(viii) Plain shoe - 110 mm |
100 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVCrainwater, soil, waste & vent pipesbymeansof50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work andfixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete. (i) 110 mm |
101 | SUB-HEAD : WATER SUPPLY |
102 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall(i) 15 mm nominal outer dia .Pipes. |
103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall(ii) 20mm nominal outer dia .Pipes. |
104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall(iii) 25mm nominal outer dia .Pipes. |
105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall(iv) 32mm nominal outer dia .Pipes. |
106 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall(v) 40mm nominal outer dia .Pipes. |
107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall(vi) 50mm nominal outer dia .Pipes. |
108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. - Concealed work including cutting chases and making good the walls etc.(i) 15 mm nominal outer dia .Pipes. |
109 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. - Concealed work including cutting chases and making good the walls etc.(ii) 20mm nominal outer dia .Pipes. |
110 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. - Concealed work including cutting chases and making good the walls etc.(iii) 25mm nominal outer dia .Pipes. |
111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. - Concealed work including cutting chases and making good the walls etc. (iv) 32 mm nominal outer dia .Pipes. |
112 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work (i) 15 mm nominal outer dia .Pipes. |
113 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work (ii) 20mm nominal outer dia .Pipes. |
114 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work (iii) 25 mm nominal outer dia .Pipes. |
115 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work (iv)32 mm nominal outer dia .Pipes. |
116 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work (v)40mm nominal outer dia .Pipes. |
117 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work (vi)50mm nominal outer dia .Pipes. |
118 | Providing and fixing brass bib cock of approved quality :(i) 15 mm nominal bore |
119 | Providing and fixing brass stop cock of approved quality :(i) 15 mm dia nominal bore |
120 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):(i) 25 mm nominal bore |
121 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):(ii) 40 mm nominal bore |
122 | Providing and fixing gun metal non-return valve of approved quality (screwed end): (i) 25 mm nominal bore - Vertical |
123 | Providing and fixing gun metal non-return valve of approved quality (screwed end): (ii) 40 mm nominal bore - Vertical |
124 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
125 | Constructing masonry Chamber 30x30x50 cm, inside , in brick work in cement mortar 1:4 (1 cement :4 fine sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neatcementcompleteasper standard design :(i) With Second Class bricks |
126 | SEWAGE AND DRAINAGE WORKS |
127 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :(i) 150 mm diameter |
128 | Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design:(i) 150 mm diameter S.W, pipe |
129 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
130 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :(i) Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
131 | Extra for depth beyond 450 mm of brick masonry chamber for underground C.I. inspection chamber with same specification as mentioned in item no 20.330 complete as per standard design : (i) For 500x700 mm size |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy