|
| 1 | Earth work excavation in all kinds of soil except hsr rock requiring blasting inclusding of shoring strutting and bailing out of water whenever necessary etc., complete |
| 2 | Supplying and filling in foundation and basement with quary dustin layers of not more than 15cm thick well rammed and consolidated including watering complying with standard specification etc.complete. |
| 3 | Plain Cement Concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, lating and labour charges and all incidental charges such as water providing etc., complete as per standard specification |
| 4 | Plain Cement Concrete 1:2:4 (one cement Two sand and four aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, lating and labour charges and all incidental charges such as water providing etc., complete as per standard specification |
| 5 | Supplying and Filling Well Gravel in layers of 25cm thick including cost of gravel stacking for premeasurements watering and consolidation by power roller rolling using 12.50 cum ofgravel for 10 m3 for finished work etc. Complete |
| 6 | Supplying and erecting shuttering with necessary supports for plain surface such as RCC boxing side slab, and similar, RCC Slab with all cross bracings etc., complete in all floors of any height (The retrieved materials should be taken back by the contractor).The payment for centering shall be given after the concrete is laid. (Vertical Portion Only) using steel plates10m2. |
| 7 | Supplying and erecting shuttering with necessary supports for plith beam with all cross brancings etc.., complete (Rcc coloumn footing plinth beam and lintel sides) |
| 8 | Supplying and erecting shuttering with necessary supports for plain surface such as RCC boxing side slab, and similar, RCC Slab with all cross bracings etc., complete in all floors of any height (The retrieved materials should be taken back by the contractor).The payment for centering shall be given after the concrete is laid. (Bottom Only) using steel plates10m2. |
| 9 | Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken / and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherevernecessary as directed by departmental officer etc., complete. |
| 10 | Supplying fabricating and placing in position of MS grills for reinforcement rate inc. the cost of steel for all works (the rate to include cost of binding wire also). |
| 11 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT Ground Floor Super Structure |
| 12 | Supplying and Fixing of Cuddapah Slab 38 / 40mm Thick. MDU-CORP-BUILDING DATA-P-14 |
| 13 | Plastering with CM 1:5 (one cement and five sand) 12mm thick10m2. |
| 14 | Plastering with CM 1:3 (one cement and Three sand) 10mm thick10m2. Ceiling |
| 15 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m |
| 16 | Painting two coats with Oil bound Distember over one coat of wall primer |
| 17 | Painting wall surface with two coat of Synthetic Enamal paint oapproved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m |
| 18 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved byMunicipal Engineer before use on work |
| 19 | Dadooring the colour glazed wall tiles of size 300mmx200x6mm pardon cement morter 1:2:10mm thick and pointing with white cement using 0.40kg/m2 including finishing the joints and pointing flesh with total surface etc., complete |
| 20 | Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with G1/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packingwith screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work TWAD P.No : 177 |
| 21 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. B.Data P.no : 43 |
| 22 | UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work PWD SOR Pg. No. 66 |
| 23 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steelreinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lamInstallation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. PWD P.no : 74 |
| 24 | Wiring with 2x2.50 sq.mm PVC unheated SC Aluminium cable of 650 V grade in suitable PVC rigid pipes in wall or ceiling with PVC accessories with TW switch box in flush with wall covered by hylum sheet3mm thick and painting with suitable colour of 14 SWG TC wire for light point. and Fan Point TWAD-DATA-P--SL No: |
| 25 | Supplying and fixing of 48” AC ceiling fan with 300mm down rod on the existing clamp with regulator with complete set |
| 26 | Supply and fixing of single box type18\"W 4Feet LED flu Fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu.Tube with PVC unsheated leads from terminals to the fitting. TWAD-DATA-P--SL No: |
| 27 | Weathering Course with Concrete Broken Brick Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete.-1 m 3 MDU-CORP-BUILDING DATA-P-36-SL No:46 |
| 28 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete MDU-CORP-BUILDING DATA-P-40-SL No:47 |
| 29 | Providing water closet 580mm size orissa type indian make with (P) Trap including ixing a pair of foot rest over a bed of brick jelly concerete in LM 1:2 using 40mm broken brick jelly 100mm thick and top plastered with CM 1:3 20mm thick etc. cost of water closet foot rest and trap each |
| 30 | Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia \"B\" Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc PWD P.No : 59 |
| 31 | Construction of inspection chambers of following sizes with earth work excavation for foundation , 23cm thick concrete bed using 40mm brick jelly concrete in cm 1:4:8 for foundation , brick work in cm 1:6 for chamber , plastering with cm 1:3 , 12mm thick , benching , channelling , supplying and fixing 45x45cm medium weight L.S cover and frame etc.complete.., (Size 60x60) |
| 32 | Providing Rain Water Harvesting arrangements in corporation building by inserting of 150mm PVC slotted casing pipe, including earth work excavation for 900mm precost cement Ring 5nos filling with One, three, Fifth Rings are 40mm metal and Two and Fourth Rings are Sand providing necessary pipe line arrangements eith std specification etc, complete |
| 33 | Writing Name board and Art painting work in Name Board the rate shall be include the cost of artist, paint scaffolding and all labour charges etc.complete.., |
| 34 | Supply and delivery and fixing of GI Pipes and specialsas per IS Specification110mm PVC Pipe |
| 35 | 32mm PVC Pipe |
| 36 | 25mm PVC Pipe |
| 37 | 110mm PVC Couplker |
| 38 | 110mm PVC Elbow |
| 39 | 32mm PVC Coupler |
| 40 | 32mm PVC Elbow |
| 41 | 32mm PVC TEE |
| 42 | 32mm x 25mm Reducer |
| 43 | 25mm PVC Coupler |
| 44 | 25mm PVC Elbow |
| 45 | 25mm x 15mm TEE |
| 46 | 1/2\" CP Tap |
| 47 | 32mm GI pipe |
| 48 | 32mm GI Coupling |
| 49 | 32mm GI Bend |
| 50 | 32mm GI Elbow |
| 51 | 32mm Gate Valve GM |
| 52 | 32mm NRV Valve GM |
| 53 | 32mm GI Hex Nipple |
| 54 | 32mm GI Union |
| 55 | 32mm GI Tank Nipple |
| 56 | Conducting Geological Survey to fix borewell point |
| 57 | Drilling 150mm dia borewell in all kinds of soils except hard rock by first taking pilot bore and then enlarged to required dia meter to enable inserting the PVC casing pipe by directed rotary mud and circulation method including all labour and water etc.complete. (TWAD data Pg.No: 281 Sl.no:12(a) |
| 58 | Supply of 150mm O.D PVC casing pipe as per Iss.(TWAD data Pg.No: 22 Sl.no:1) |
| 59 | Labour charges for inserting 150mm O.D PVC casing pipes assembly (with slot or without slots) in the drilled bore including jointing the pipesetc complete. (TWAD data Pg.No: 283 Sl.no:13a) |
| 60 | Drilling of 150mm dia vertical bore in hard rock to the required depth including charges for labour, fuel, water required for crilling etc complete. (TWAD data Pg.No: 280 Sl.no:11(a) |
| 61 | Supply of 125mm diaPVC Casing Pipe and Labour charges etc complete. |
| 62 | Developing the borewell with air compressor of 300cfm capacity (min 8 hours) including transporation labour and fuel charges for comperessor as directed by corporation yield test by \"V\" notch method. (TWAD data Pg.No: 284 Sl.no:13b) |
| 63 | THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 150MM DIA-5HP BOREWELL AS PER IS 8034/2002 WITHOUT PANEL BOARD Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor asper IS 9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/-10%, 50HZ +/- 5 %, 50 lpm x 175mtr |
| 64 | THREE PHASE PANEL BOARD- D.O.L. WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to S13947 and IEC 947 suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). - 5HP |
| 65 | Supply and deliveryof PVC insulated and sheathed 4.0sqmm copper cable conforming to IS 694/1990 suitable for submersible pump set. |
| 66 | Labour charges for erection of submersible pump set bore well in cluding fixing and jointing submersible cable with proper clamps pressuregauge up to the exrterior wallof pumproom kisok and erection of panel board consisting of TPCIN switches starter volt meter ammeter thre indicator tamp capaciator single phase preventor ater level guard laying and jointing if cables and earthing complete the pumpset on trial for 3 days. |
| 67 | Supply and delivery of 2000 lit capacity and fixing of HDPE tank as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification. |
| 68 | Labour charges for over head wiring from EB pole to pumproom by fixing 32mm dia GI pipe to the required height over roof slab of pumproom and as directed by EB authorities including fixing M.S. clamp set, U.Kondi, 7/20 GI wire, 7/20 PVC insulated copper wire reels, T.W. meter board, aerial board, earth plate GI Bolt of nuts, PVC Hose fuse wiring etc. complete |
| 69 | Add GST 18% |