Tender For Periodical Maint Of Dehumidifier,Fire Alarm System,Eot Cranes And Other Misc Items At 19 Wing Af And 14Brd Af Under Ge(Af) Borjhar., borjhar-Assam

Military Engineer Services-MES has published Tender For Periodical Maint Of Dehumidifier,Fire Alarm System,Eot Cranes And Other Misc Items At 19 Wing Af And 14Brd Af Under Ge(Af) Borjhar.. Submission Date for this Tender is 17-07-2023. Alarm Systems Tenders in borjhar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

38476759
Tender For Periodical Maint Of Dehumidifier,Fire Alarm System,Eot Cranes And Other Misc Items At 19 Wing Af And 14Brd Af Under Ge(Af) Borjhar.
Open Tender
Indian
Assam
borjhar
17-07-2023

Tender Details

Periodical Maint Of Dehumidifier,Fire Alarm System,Eot Cranes And Other Misc Items At 19 Wing Af And 14Brd Af Under Ge(Af) Borjhar.

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: Periodical maint of dehumidifier,fire alarm system,EOT cranes and other misc items at 19 Wing AF and 14BRD AF under GE(AF) Borjhar.
Sl. No. Item Description
1COMPREHENCIVE REPAIR / SERVICE / MAINTENANCEof Electric Operated Over Head Travelling Cranes ( EOT Cranes ) of following capacities installed at various work shops at Ordnance depotand EME Work shops and keep the EOT cranes operational round -the -clock . EOT cranes are double girder type , electric motor driven , for longitudinal traverse , Cross traverse , hoists ,micro speed , in all motions . The details of the maintenace required to be carried out is as given below :-
22 Ton Capacity
33 Ton Capacity
45 Ton Capacity
510 Ton Capacity
6NOTE :- The scope of above works covers the following :- (i) The repair / servicing / maintenance works on the EOT cranes shall be carried out by the trained / skilled technicians and shall conform to the standard engineering practice / code and as per the standard code/ norms of Government . (ii) The Cranes shall be inspected and serviced at the rate of minimum of one service per month. (iii) Attending to any break down within 24 Hours and restoring the service (iv) The services shallinclude periodical cleaning, greasing , oiling and thorough inspection of various system / parts, brakes , hoist wires ropes , rail align ment , DSL cuurent collectors , bus bars , tightening of bolts, nuts , electrical terminals etc.,and ensuretheir serviceability and proper function and safety . (v) Replacement of unserviceable electrical and mechanical spares/ parts, cables , Pendant type controls ,oil , grease ,Electric control panels, Gantry rails, steel wire ropes , drums , brake system , brake liners & control switches , bus bars , bus collectors etc.,as and when become unserviceable and ensure trouble free smooth operation
7(vi) Replacement of gear oil grade 90 / 140 once in a year (v) Cleaning the entire crane and painting once in a contract period. (vi) Carrying out the load test once in a year or as and when required after a major repair work . Loads will be arranged by the Dept. (vii) Rewinding of Electrical motors , replacement of bearings etc.,as and when required (viii) Arranging thorough Inspection by authorised Govt Licensed Inspector and sumission of Inspection report in triplicate.
8(ix) Insurance coverage for all technicians , workers involved in the works. (x) Record / maintain register of all maintenance carried out , spares replaced etc., all as specified and as directed by in charge. (xi) Adherence to safety rules and regulations in respect of EOT Cranes (xii) Adherence to Security rules and regulations of the Ordnance depot. (xiii) A list of Makes / brands of spares / materials to be incorporated in the works shall be got approved immediately after getting the work order. (xix) All tools , instruments and plants requirted for carrying out the above works shall be provided by the contractor.
9M&L Dismantling existing unserviceable wodden platforms of any size / type from cranes / platfoms / walk ways etc., for replacing with MSChequerred plates. all as specified and as directed .
10M&L forMS Chequerred plate of thickness 6 mm with stiffners as required including necessary cutting to sizes ,, drilling of holes , welding , finishing , fixing on cranes platforms / walkways etc.,, applying two coats of synthetic enamel paint over one coat of red oxide primer ,all as specified and as directed .
11Dismantling existing MS Bus bars100 Amps capacity 4 Nos each 50 RM from the bus duct including insulators with rod - 100 Nos , DSL pushing arms 4 Nos, disconnection of travelling cables ,for replacement with copper wire bus bars.all as specified and as directed .
12M&L fixing Bare copper conductor Buswiresof size6 mm dia fixed as bus conductor in the existing bus duct.
13M&L for fixing insulators pin type with rod and hylam washers etc., for fixing bus conductors.
14M&L forMS angle section any size as required fixed inside bus duct for fixing insulators including necessary cutting , welding drilling holes etc. all as required at site and directed by Engineer - in - charge.
15M & L for fabrication work with MS Angle / MS plate /MS Channel/MS nut bolt washer of suitable sizes and thick including painting with two coat of synthetic enamal paint over a coat of Red oxide primer complete for HOT/EOT crane rail or any other works all as specified and as directed.
16Disconnecting all electrical connection taking down following items for replacement with new oneand testing checking etc complete of dehumidifier (from manufactuerer authorised service person) for model Sl No- 2013-BAC-18952. (a) Heaters 4 KW complete. Nos -03(b)Air Pressure Switch complete. No-.01 (c) Contactor complete Nos- 02 (d)Thermostate complete. Nos-02
17S&F following spare parts for above mentioned item no 9 :-
18(a)Heaters 4 KW complete.
19(b)Air Pressure Switch complete .
20(c)Contactor complete.
21(d)Thermostat complete.
22(e)Filter,460x510x50,BOX,EU-3,HT
23(f) Filter,305x910x50,BOX,EU-4
24Comprehensive Service/Repair/maintenance and monthly visit for regular maintenance for the Automation of intelligent addressable fire alarm control panelat 118HU hanger, 59 SQN hanger, CNGO Complex Hanger , BCR Building, AFNET site -2, and EE hall, Logistic Section,Base Ops including checking testing and cleaning of Loop card ,Main board, LCD display, Multisensor, sounder, MCP, , Repeater Panel, Zone monitor Module, UV&IR detector, Remote Response indicator, Loop Isolator, Amplifier andLoud speakers carrying out normal repairs for the trouble free and efficient functioning of the entire fire alarm system by providing one engineer for Monthly visit all as directed AND AS PER SPECIFIED NFPA 72 andGuidelines. Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule "A" (ii) Contractor"s rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the user.
25Dismantling, Servicing of multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer"s instructions and testing for exact fault locations including cleaning through air blower then reinstalling every six month complete all as specified and as directed.
26Serviceabilityand Testing ofUV & IR flame detector and its alignment to detect flame with Testing Kit and when directed complete all as specified and as directed.
27Supply & fix in repairs 12 V, 7 AH battery for Inverter supply for back up to all FACP panel complete all as specified and as directed. Make: EXIDE/AMAR RAJA/AMCO/AMARON
28Supply and Fixing in repair or replacement of Indoor addressable detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence complete all as specified and as directed. Make:- GST/COOPER/BOSCH/SEIMENS
29Supply only of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, = 0.6 mA (Standby Current) =1.8mA (Alarm Current) b) Class A , c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key, d) Ingress ProtectionIP-43 & Material-ABS Make:- GST/COOPER/BOSCH/SEIMENS
30Supply only of the annunciating device Remote response indicator complete all as specified and directed. Make:- GST/BOSCH/SEIMENS
31Supply only of fire alarm sounder/sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range complete all as specified and directed. Make:- GST/COOPER/BOSCH/SEIMENS
32Supply only oftheindoordetectorcomplyingwithandtypecertifiedtoEN -54AddressabletypeflamedetectorswithUVandIRdetectioncapacity(addupcostofmoduleto beacompleteset,thetypeofmoduleshallberelaytypemodule)withselfbuiltintelligencecompleteallasspecifiedanddirected. Make: SIEMENS/AGNI/GST/HONEYWELL
33Supply only of Zone Monitor Module compatible with Fire Alarm Control Panel complete all as specified and as directed. Make: GST/COOPER/BOSCH/SEIMENS
34Supply onlyofGST200 Rubber Keypad F7.843.249for FACP complete all as specified and as directed.
35Supply only of GST200 Loop Interface Board F2.908.828 (RoHS)for FACP complete all as specified and as directed.
36Supply onlyofGST200 Power Supply Unit F2.932.069 (20100682)for FACP complete all as specified and as directed.
37Supply only of Transformer 220V/27V-100W-R for FACP complete all as specified and as directed.
38Supply only of two core copper conductor of size 1.5sqmm FRLSH flexible shielded cable complete all as specified and directed. Make: HAVELLS INDIA LTD/INDIA LTD INDO AMERICAN ELECTRICALS FINOLEX/ NICCO/KEI/POLYCAB/RR KABLE LTD
39Supply and fixing ofSMPS Adapter 24 Volt 2.0 Amp Make- protek
40Supply And Fixing RS 485 Network Card for fire alarm control Panel Make- GST
41Supply and Fixing Media Convertorfor RS 485 toFiber Optic convertor Make-GST
42M&L for detection of OFC cable fault through OFC cable fault locator all as specified and directed.
43M&L for jointing the damage OFC cable through OFC cable Jointing Kit complete all as specified and directed. Note:- Any earth work, sand cushioning & brick protection for OFC cable shall be measured & paid separately.
44Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through maually.
45Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
46Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
47M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
48M & L brick protection with old size sub class ‘B’brick for PVC underground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
49M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
50Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 25 sqmm 3.5 core (heavy duty), aluminium strandedconductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
51Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 35 sqmm 3.5 core (heavy duty), aluminium strandedconductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
52Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 70 sqmm 3.5 core (heavy duty), aluminium strandedconductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
53M&L 40 mm bore GI tubing“light grade” in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge.
54S&F PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 2 Core.
55S&F PVC insulated, Unarmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 2.5 sq. mm 3 Core.
56S&F Rigid non-metallic PVC conduit of external dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
57S&F Auto fire offABC Dry powder type fire extinguisher plastic ball for direct on flame with minimum capacity 1.5 kg.