Tender For Addition / Alteration To Mt Section Bldgs In Tech Area At Af Stn Adampur, adampur-Punjab

Military Engineer Services-MES has published Tender For Addition / Alteration To Mt Section Bldgs In Tech Area At Af Stn Adampur. Submission Date for this Tender is 31-07-2023. Building Work Tenders in adampur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38476619
Corrigendum : Tender For Addition / Alteration To Mt Section Bldgs In Tech Area At Af Stn Adampur
Open Tender
Indian
Punjab
adampur
31-07-2023

Tender Details

Addition / Alteration To Mt Section Bldgs In Tech Area At Af Stn Adampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jul-2023 BoQ and Schedule of credit BOQ 24-07-2023
2 24-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 85800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: ADDITION / ALTERATION TO MT SECTION BUILDING AT AF STN ADAMPUR
Sl. No. Item Description
1BR WORKS
2Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting outin SOFT/LOOSE soil complete, all as specified.
3Excavation over areas in SOFT/LOOSE soil not exceeding 1.50 metre deep and getting out complete, all as specified.
4Excavation over areas in SOFT/LOOSE soil exceeding 1.50 metre but not exceeding 3.00 metre deep and getting out complete, all as specified.
5Excavation in trenches n. exc 1.5 m wide for foundations, laying cables / pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soilcomplete, all as specified. (B/R:- 10 Cu.m, E/M:- 50 Cu.m)
6Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete, all as specified. (B/R:- 34 Cu.m, E/M:- 41 Cu.m)
7Removal of excavated surplus spoil to a distance exceeding 250 metre but n. exc. 1 km and depositing where directed at level not exceeding 1.5 m above the starting point complete, all as specified.(B/R:- 40 Cu.m, E/M:- 9 Cu.m)
8Broken stone hardcore of gauge exc. 63 mm but not exc 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified.
9Providingand injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and roddingetc. complete all as specified.
10Post construction anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified.
11PCC type B-2 (1:2:4), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
12PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
13Cement concrete, type B-1 (1:2:4), using 12.5 mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified.
14Reinforced cement concrete,M-25 (Design Mix), as in in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified.
15Reinforced cement concrete, M-25 (Design Mix), as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
16Reinforced cement concrete, M-25 (Design Mix), as in chajjas, and the like complete all as specified.
17Reinforced cement concrete,M-25 (Design Mix), as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified.
18Reinforced cement concrete,M-25 (Design Mix), as in columns, pillars, piers, posts and struts complete all as specified.
19Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
20Brick work in half brick thick wall using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
21Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends, or edges of landings etc. and cutting chases for concealed water tubing, concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, in brick walls, complete all as specified.
22Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified.
23Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified.
24Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified.
25Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchionswith rough finished surfaces of concrete, complete all as specified.
26Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete, all as specified.
27Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded wood grain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and wood grain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified.
28Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforcedwith mild steel square tube, suppling & fixing in opening, complete all as specified.
29Aluminium anodised barrel tower bolt of extruded section 200 mm long, ISI marked, complete all as specified.
30Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extrudedsections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long,complete all as specified.
31Stainless steel butt hinges 100 mm long, ISI marked, complete all as specified.
32Extruded aluminium anodised handles fabricated type with plate 125 mm long, ISI marked complete all as specified.
33Door closer hydraulically regulated, aluminium die cast body, designation No. 2 universal type, suitable for door shutters up to 701 to 850 mm in width and of weight between 36 to 60 kg, ISI marked, complete all as specified.
34Stainless steel conduit 20 mm bore, cut to size and erected in position as curtain rod on backets, with & including SS decorative finials & brackets, PVC rings @ 10 nos. per metre, fixed to walls with PVC rawl plugs & SS screws,complete.
35Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanized wire staples, all as specified.
36Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified.
37Mild steel bands, straps, supports, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; chains; hand made sliding bolts; clamps; hold fasts; wall ties;plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles confirming to Fe-290-Gde E-165, complete all as specified.
38Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
39Mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
40Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.
41Powder coatedaluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
42Powder coated aluminium door shutters with styles & rails made out of section size83-85 mm x 44-45 mm (wall thickness not less than 2 mm) , anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats &screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
43Powder coated aluminium window and ventilator shutters side hung type with styles & rails made out of section size47-48 mm x 44-45 mm (wall thickness not less than 1.58 mm), anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats &screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
44Powder coated aluminium grilltype DG-117 including necessary "U" clip &screws etc as per manufacturers instructions, complete all as specified.
45Powder coated aluminium frame for doors, windows, ventilators, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc., (aluminium section not less than 2 mm) complete all as specified.
46Plain tinted sheet glass, 5-6 mm thick, ordinary quality duly sticked with solar control reflective type film, having thickness not less than 25 micron and fixed air tight with neoprene packing & almn glazing clips, for aluminium sections, complete all as specified. NOTE: Almn glazing clips & neoprene packing will be measured & paid for under respective item of aluminium door/windows/partition.
47Aluminium composite panel sheet 4-5 mm thick, of shade approved by GE, cut to shape and fixed in position as almn door shutter panels/partition,complete all as specified.
48Water Proofing Treatment to RCC roofs comprising of : -
49Taking down existing water proofingtreatment (any no. of layers) from RCC roofs includingcleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified.
50PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, complete all as specified.
51Rendering15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fairin cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
52APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified.
5340 mm thick brick tiles are bedded over 15 mm thick cement mortar (1:4),and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified.
54Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE,complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
55NOTE : For Guarantee of Water Proofing Treatmentrefer PS clause 11.5.
56Supply only water proofing compound, ISI marked, complete all as specified.
5725 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
5875 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection,and joints shall be sealed with joint sealing comound grade "A" complete all as specified.
5975 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
60Glazed ceramic coloured tiles 7mm thick,area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified.
61Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m,laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified.
62Non skid dark shade vitrified (double charged) tiles 9-10mm thick (square/ rectangular) area of each tile exc. 0.20 Sq.m but n. exc. 0.36 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified.
63Factory made PCC colured chequered tiles, ISI(IS:13801) marked, 22-25 mm thick, of size 250 mm x 250 mm, in floors, over & including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete, all as specified.
64Endura vitrified paving coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but not exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified.
6560 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete.
6680 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete.
67Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar (1:6)complete all as specified.
68Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
69Two coats of interior acrylic distemper/oil bound distemper on old wall surfaces, including preparation of surfaces, complete all as specified.
70Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer
71Prepration of old plasterd wall surfaces of any descriptionand applying two coats of exterior acrylic emulson in disruptive/camouflaging pattern of four shades complete all as specified.
72Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer in disruptive/camouflaging pattern of four shades complete all as specified.
73NOTES APPLICABLE TO SRL ITEM 64 & 65 HERE-IN-ABOVE: (i) Entire quantity of material for this work shall be procured by the contractor from manufacturer"s Depot & deposit the same with Enginer-in-Charge and same shall be issued to contractor on daily basis as per consumption at site. (ii)RGB value of four shades of disruptive/camouflaging pattern shall be all as shown on Drg No. GE/SK-1/19 sheet 1/2 & 2/2. (iii)The rate quoted by the contractor shall included for scaffolding and necessary formwork.
74Plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.min each pane complete all as specified.
75Figured glass 4mm thick ordinary quality and glazing with oil puttyin squares n. exc. 0.5 Sq.min each pane complete all as specified.
76500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, IN REPAIR, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, IN REPAIR, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type)with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, IN REPAIR, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP, IN REPAIR, complete all as specified.
77Steel tubes 15 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
78Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
79Steel tubes 25 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, (For Urinal flush cock) complete all as speciifed.
80Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6510 or equivalent make mentioned in Appendix "B".
81Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6518 or equivalent make mentioned in Appndix "B".
82Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe,complete. MAKE: PRAYAG Cat No. 6508 or equivalent make mentioned in Appendix "B".
83Pillar tap, cast copper alloy, chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6502 or equivalent make mentioned in Appendix "B".
84125mm size overhead ABS shower with cast copper alloy chromium plated arm 225 mm long with flange andfixed in position, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BS-76 or equivalent make mentioned in Appndix "B".
85Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), 110x125 size uPVC "P" trap & necessary joints, lime concrete IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. 4055 or equivalent make mentioned in Appendix "B"
86Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, including stainless steel body Jet spray (L-bend) with1.50 metre long braded tube tube, IN REPAIRS,complete all as specified MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix "B".
87PVC seat & cover, IN REPAIRS,complete all as specified MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix "B".
88Toilet paper holder, brass chromium plated body IN REPAIRS,complete all as specified MAKE OF EWC: PRAYAG Cat No. BA18 or equivalent make mentioned in Appendix "B".
89Vitreous China wash hand basin, white, flat back, size 550 x 400 mm, ISI marked,including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe,IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appendix "B"
90Vitreous China half stall Urinal pot, white, size 345 x 320 x 560 mm, with & including cast copper alloy, half or full threaded chromium plated waste couplingsuitable for & including 32 mm size PVC waste/discharge pipe, rag bolts,IN REPAIRS, complete. MAKE OF URINAL: PRAYAG Cat No. 4998 or equivalent make mentioned in Appendix "B".
91Health faust with 1 metre SS tube & hook complete. MAKE OF URINAL: PRAYAG Cat No. BEA-97 or equivalent make mentioned in Appendix "B".
92Flush cock (lever type) 25 mm size for urinals complete. MAKE OF URINAL: PRAYAG Cat No. BEA-32 or equivalent make mentioned in Appendix "B".
93PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories,IN REPAIRS, complete. MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appendix "B"
94Looking mirror 600 x 600 mm, selected quality glass 5.5 mm thick, mounted on PVC ply not less than 4 mm thick, and provision of PVC frame alround fixed with chromium plated brass screws and rawl plugs, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 553 or equivalent make mentioned in Appendix "B".
95Glass shelf 500x125 mm with brass brackets and fixed to wall with chromium plated brass screws and rawl plugs, complete. MAKE: PRAYAG Cat No. BEA-45 or equivalent make mentioned in Appendix "B".
96Brass chromium plated towel rail500-600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix "B".
97Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-15S or equivalent make mentioned in Appendix "B".
98Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints,complete all as specified.
99PVC connections 15 mm size of length 600 mm with PTMT nuts,complete all as specified.
100Stainless steelpeg set of six, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BEA-30 or equivalent make mentioned in Appendix "B".
101uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified.
102uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified.
103uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia,IN REPAIRS, complete all as specified.
104uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia,IN REPAIRS, complete all as specified.
105uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified.
106uPVC floor trap,suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified,
107Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified.
108Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.
109Cutting into existing manholes for connecting new drains, of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
110Construction of "SEPTIC TANK"for 100 users complete all as specified and shown on drawing No. CEAF/STD/ST-73/2019 sheet 1/1.
111Construction of "SOAK WELL"of size 3.60 m dia & 3 metre effective depth complete all as specified and shown on drawing No. CEJZ/STD-301/90 sheet 1/4 to 4/4.
112EM WORKS
113Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ socketscomprising the following: -
114One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
115One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
116One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
117One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
118One socket outlet three pin, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
119NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule "A". (b) GI boxes shall be fixed flushto walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
120Switch piano flush button single pole one way, 6 Amp complete all as specified.
121Switch piano,bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified.
122Switch piano flush button single pole one way, 16 Amp complete all as specified.
123Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
124Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
125Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
126Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
127Electric buzzer AC 230 volt, single pole, Ding Dong type complete, all as specified.
128Fan regulator (electronic) suitable for 48”/56” sweep fan, step down type, single phase, complete all as specified.
129Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
1302 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
1312 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
132NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii)For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
133Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
134Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
135SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type.
136SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
137SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.
138TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 63 Amp, 16kA.
139MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, "C" curve type of rating6 to 32 Amp complete all as specified.
140MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, "C" curve type of rating 40-63 Amp complete all as specified.
141Blanking plate to cover unused space in DB"s complete all as specified..
142Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.
143Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.3.3.1 of contract, IN REPAIRS. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit.
144Envirnment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K,complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPCor equivalent in makes mentioned in Appendix "B" here-in-after.
145Surface mounted envirnment friendly decorative ultra slim round profile LED 10 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix "B" here-in-after.
146Surface mounted envirnment friendly decorative ultra slim round profile LED 22 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent in makes mentioned in Appendix "B" here-in-after.
147Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix "B" here-in-after.
148Ceiling fan 1200 mm sweep, 230 V with blades & down rod, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated, brushless direct current motor (BLDC) and connecting up from ceiling rose or connector to fan, complete all as specified.
149Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting upfrom ceiling rose or connector to fan, complete all as specified.
150Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
151Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
152Steel tubes 50 mm bore ‘light grade’, galvanized with all fittings andfixed to poles/ walls/ under floors/ under road etc complete all as speciifed.
153Steel tubes 80 mm bore ‘light grade’, galvanized with all fittings andfixed to poles/ walls/ under floors/ under road etc complete all as speciifed.
154Supply, laying, jointing & testing of LT XLPE insulated cable screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor conforming to IS-7098 (Part-I -1988)laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing including takind down existing cablecomplete all as specified of sectional area 35 Sq. mm, 3.5 core.
155Supply, laying, jointing & testing of LT XLPE insulated cable screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor conforming to IS-7098 (Part-I -1988)laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing including takind down existing cablecomplete all as specified of sectional area 120 Sq. mm, 3.5 core.
156DISMANTLING/DEMOLITION WORKS
157Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
158Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified.
159Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified. .
160Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified. .
161Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
162Demolition of cement concreteof any description and in any position not otherwise specifically provided all as specified.
163Demolition of mud phuska in roofs, of thickness not more than 200 mm including plaster and leeping plaster all as specified.
164Dismantlig brick tiles in roof laid dry and pointed in cement mortar all as specified.
165Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
166Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
167Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc.and making good surface as per existing, complete all as specified.
168Taking down carefully light fitting of any description, complete all as specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail