Tender For Repair / Maintenance Of Certain Misc E/M Equipment Such As Smoke Detector / Fire Alarm System / Window / Split Air Conditioning / Aviation Light Alongwith Connected E/M Work At 901 Su Air Force Station Nathatop Under Ge (Af) Udhampur, udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Certain Misc E/M Equipment Such As Smoke Detector / Fire Alarm System / Window / Split Air Conditioning / Aviation Light Alongwith Connected E/M Work At 901 Su Air Force Station Nathatop Under Ge (Af) Udhampur. Submission Date for this Tender is 21-07-2023. Smoke Detectors Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38424944
Tender For Repair / Maintenance Of Certain Misc E/M Equipment Such As Smoke Detector / Fire Alarm System / Window / Split Air Conditioning / Aviation Light Alongwith Connected E/M Work At 901 Su Air Force Station Nathatop Under Ge (Af) Udhampur
Open Tender
Indian
Jammu And Kashmir
udhampur
21-07-2023

Tender Details

Repair / Maintenance Of Certain Misc E / M Equipment Such As Smoke Detector / Fire Alarm System / Window / Split Air Conditioning / Aviation Light Alongwith Connected E / M Work At 901 Su Air Force Station Nathatop Under Ge ( Af ) Udhampur

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR / MAINTENANCE OF CERTAIN MISC E/M EQUIPMENT SUCH AS SMOKE DETECTOR / FIRE ALARM SYSTEM / WINDOW / SPLIT AIR CONDITIONING / AVIATION LIGHT ALONGWITH CONNECTED E/M WORK AT 901 SU AIR FORCE STATION NATHATOP UNDER GE (AF) UDHAMPUR
Sl. No. Item Description
1Servicingof Fire Alarm control panel complying with adderssable typesingle loop panel /double loop of capacity from 99 detectors & modules upto 200 detector with UV/IR Detection capacityincludingthe followingtechnical specifications and all specified and directedby AGE E/M Note :- (a) Primary power supply : 220v +/- 10% AC, 50Hz (b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries ) (c) Battery charging voltage ; 27.5 +/- 1V (d) Battery caharging current : 500 mA (max) (e) Pragrammable relay contact : 3 Sets. (f) Relay Contact Rating : 2 Amps 30 V DC (g) Operating temp :- 100C to +550C (h) Humidity : 0 to 95% RH (i) Internal wiring complete two core (j) 1000 event history log (k) Built in battery Charger (l) Two level password protection (m) Contamination level alart for maintenance (n) Detection sensitivityadjustments (from panel) (o) Alarm verification feature
2Servicingof Fire Alarm control panel complying with Conventional typepanel /double loop of capacity from 99 detectors & modules upto 200 detector with UV/IR Detection capacityincludingthe followingtechnical specifications and all specified and directedby AGE E/M Note :- (a) Primary power supply : 220v +/- 10% AC, 50Hz (b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries ) (c) Battery charging voltage ; 27.5 +/- 1V (d) Battery caharging current : 500 mA (max) (e) Pragrammable relay contact : 3 Sets. (f) Relay Contact Rating : 2 Amps 30 V DC (g) Operating temp :- 100C to +550C (h) Humidity : 0 to 95% RH (i) Internal wiring complete two core (j) 1000 event history log (k) Built in battery Charger (l) Two level password protection (m) Contamination level alart for maintenance (n) Detection sensitivityadjustments (from panel) (o) Alarm verification feature
3S&F in repair ofAddressable manual call point resttable type fire alarm typepanelthe following technical specifications and all specified and directed Engr-in-Charge.(a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarmflag for fast alarm reporting.
4S&F in repair ofconventional fire alarm panelthe following technical specifications and all specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarmflag for fast alarm reporting.
5Supplyand replacement of Smoke Detectors Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
6Supplyand replacement of Mother board (Addrassable type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360including taking down omplete all as specifeid and as directed.
7Supplyand replacement of Mother board (Conventionaltype) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360complete all as specifeid and as directed.
8Supplyand replacement of Hooter Conventional/addressable type Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360complete all as specifeid and as directed.
9Supplyand replacement of manual call point Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360including taking down complete all as specifeid and as directed.
10Servicing and cleaning of Smoke Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360as per existing and arrangement of ladder of suitable building heightcomplete all as specifeid and as directed.
11S&F in repair ofRemote response indicatorsaddressable typeincludingthe following technical specifications and all specified and directed Engr-in-Charge.(a) Operating voltage : between 15-30 volts DC peak (b) Active average current : Less than 20 mA(c) Operating tem :- 100c to +550c(d) Humidity : 0 to 95% RH(e) Wiring : 2 core (f) Capable of high response (g) Real time response
12Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded copperfire serval cable conductor of size 1.5 sq mm ,2 core, 1100 Volts grade including taking down completeall specified and directed Engr-in-Charge. (Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
13Supply, laying & testing PVC insulated, PVC sheathed FRLSelectric control cables (Heavy duty) with strandedfire serval cable copper conductor of size 1.5 sq mm ,6 core, 1100 Volts grade complete including taking down all specified and directed Engr-in-Charge.(Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
14Supply and repair of Batterysealed accied as per existing sizesuitable for control panel 24 V DC (2 Nos of 12V, 7 SMF batteries )complete all as specified and as directed.
15Maintanence and repair Remote response indicators conventional type includingincludingreplacement of unservisble spare parts and all specified and directed Engr-in-Charge.
16M & L for Servicing and maintanence forIndoor and outdoor unit of split type Air conditioners 1.5/2.00 Ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete withreassembling the same one, inclgood cleaning carefully for out side area used soft cloth with coolin/ shopand testing the same to the entire satisfaction of Engineer-in-Charge, all as directed.
17M & L for Disconnecting, cutting and takingout EvaporatedCoilfor indoor / Condensing coil for outdoor unitfor 1.5/2.0 ton AC Invertor/Non invetor typefind out gas leaking area and brazing work complete and cleaning refitting with testingcomplete all as specified and directed by the Engineer-in-charge.Note :- The cost of itemshall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
18M & L forDisconnecting, cutting and taking out unserviceable compressorinveter type for 1.5 Ton Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make :Highly/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
19M & L for Disconnecting, cutting and taking out unserviceable compressor inverter type for 2 Ton Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make :Highly/ Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
20M & L forDisconnecting, cutting and taking out unserviceable compressornon Inverter typefor 1.5 Ton/ 2.00 TON Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make :Highly /Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
21M & L for in repair (Existing make & size )Panellcontrol Boardof Invrter type including remote and display of 1.5/ 2.0 Ton AC, all as specified and directed.
22M & L for in repair (Existing make & size )Panellcontrol Boardof non Invrter typeof 1.5/ 2.0Ton AC, all as specified and directed.
23M & L for in repair (eixsiting same size ) Indoor unit blower motorfor 1.5 Ton capacity AC, all as specified and directed.
24M & L for in repair (eixsiting same size ) Indoor unit blower of fan and bushes for 1.5 Ton capacity AC, all as specified and directed.
25M & L for in repair (eixsiting same size ) Indoor unit blower motor for 2.0 Ton capacity AC, all as specified and directed.
26M & L for in repair Hot and cold reversivle valve with resistance (eixsiting same model & size ) for 1.5/2.0 Ton capacity AC, all as specified and directed.
27M & L for in repair running capacitor 45 mfd + 3 mfd for 1.5 ton AC (combined unit), all as specified and directed by Engineer-in-Charge.
28M & L for in repair running capacitor 50+4 mfd for 2.0 ton AC (combined unit), all as specified and directed by Engineer-in-Charge.
29M & L for in repair starting capacitor 80 mfd - 100 mfd for 1.5/2.0 ton AC and deep freezer all as specified and directed by Engineer-in-Charge.
30M & L for in repair route pipe (copper tube) of size 3/8" dia complete with insulation all as specified and directed by Engineer-in-Charge.
31M & L for in repair route pipe (copper tube) of size 5/8" dia complete with insulation all as specified and directed by Engineer-in-Charge.
32M & L for in repair route pipe (copper tube) of size 1/4" dia complete with insulation all as specified and directed by Engineer-in-Charge.
33M & L for in repair route pipe (copper tube) of size 1/2" dia complete with insulation all as specified and directed by Engineer-in-Charge.
34Supply and refilling of gas R-22 & 32 in 2 .0 /1.5 Ton AC including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge.
35Supply andrefilling of gas R-410ain 1.5 /2.0 Ton AC including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge.
36M & L for in repair(eixsiting same model & size ) Copper filter for 2.0 ton split AC complete all as specifed and as directed
37M & L for in repair (eixsiting same model & size ) Copper filter for 1.5 Ton split AC.complete all as specifed and as directed
38Supply and replacingElectronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA.(Make : V- Guard model VWR 300 equivalent Micro tech) all as directed.
39Supply and replacingElectronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.(Make : V- Guard model VWR 500 equivalent Micro tech) all as directed.
40M & L in repair for taking out the voltage stabilizer of capacity up to 3 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, all as directed.
41M & L in repair for taking out the voltage stabilizer of capacity 4 to 5 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, all as directed.
42Supply and replacing (eixsiting same model & size ) control card of voltage stabilizer PCB sensor etc.all as specified and directed by Engineer-in-Charge.
43Supply and replacing selector switch for input and output voltage all as specified and directed by Engineer-in-Charge.Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ.
44Supply and replacing Ics and relays completeall as specified and directed by Engineer-in-Charge.
45M & L in repair for taking out the Refrigerator of capacity 280/310 Ltr and replacement of following parts, reassembly of unit and testing the same to the entire satisfaction of the Engineer-in-Charge. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ.
46Supply and in repairof compressor sealed unit including necessary brazing work as required.
47Supply and in repairof Thermostate switch suitable for 280/310 Ltrs caapcity refrigerator.
48Disconnecting and dismantling and transfortation of UPS from system and main supply and making alternate arrangement for smooth functioning of the system at radar room AF Nathatop to workshop for repair.
49Opening the UPS UP TO 5 KVAand repairing the main control card by replacing, trickling ckt, charging ckt, integrated ckt, etc from the manufacture and testing as per manufactured design all as directed by user at site.Note:- All the spare parts aremeasured and paid seperately
50Opening the UPS 6 to 10 KVAand repairing the main control card by replacing, trickling ckt, charging ckt, integrated ckt, etc from the manufacture and testing as per manufactured design all as directed by user at site.Note:- All the spare parts aremeasured and paid seperately
51Replacement of resistance 1.5 OHM 20 Watt as per sample
52Replacement of AC capacitor( 4300/UF/450 Volt) as per sample
53Replacement of DC capacitor( 4300/UF/450 Volt) as per sample
54Replacement of bridge block 3 phase HD 12/12 as per sample
55Replacement of IGBT as per existing size
56Replacement of ae per DC breaker existing size
57Replacement of PCBCards as per existing size
58Replacement of Transformer existing size
59Rerplacement ofCooling Fan as per existing size
60Replacement of capacitor 2MFD 20 Watt as per sample
61Reassembling the UPS after necessary repair and replacement and testing at site including labour and transportation complete at site.
62M&L for replacementof existing unserviceable batteries of, 12 volts, 45 AH all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/Sukam/Microtek.
63M&L for replacementof existing unserviceable batteries of, 12 volts, 26 AH all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/Sukam/Microtek.
64Supply andRefilling of gas in the compressor of refrigerator of any make and capacity with R-134a gas/ carbon free gas.
65M & L in repair for Taking out Deep Freezer 320 Ltr capacity 230 V AC 50HZ , supply and replacement of following unserviceable parts, reassembling the same after repair and testing on load after completionof job, all as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ.
66Supply and in repair of compressor sealed unit including necessary brazing work as required. Make ; Voltas/ blue star/ carrier
67Supply and in repair ofblower motor for any cap/size of deep Freezer complete all as specified and as directed .
68Supply and repairof thermal over load relay. Make :- Renutrol/Indfoss or equivalent as approved by GE.
69M & L in repair for Stands for outdoor unit including drilling hole, nuts bolts , fastners etc complete all as required at site.
70M&L in repair of MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 203 volt AC supply including taking down existing old US including assesories therein & disposing from site complete all as specified
71M & L in repair for MCB DB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB20 amps complete all as specified and directed by the Engineer-in-charge.
72Supply and fixing in repair ofMCB SP 32 amp rating 240V, 10KA "C" curve miniature circuit breaker current carrying capacity in the MCB DB complete with connection testing and commissioning of complete all as specified and as directed.
73Supply and fixing in repair of MCB SPN40 to 63 amp rating 240V, 10KA "C" curve miniature circuit breaker current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
74M&L in repair ofwiring for circuit 2 core 2.5 sqmm copper conductor PVCinsulated PVC sheatedas per is 694 up to date all including drawing through PVC Conduit makingconnection with LED Building security Light/ towerlight /fitting etc complete all as specified and as directed by enginer in charge .
75Supply and fix in repair of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome ofincluding necessary electric connection2.5 sqmm 3 core pvc insulated PVC copper cable as per manufacture"s requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge.Cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips
76Supply and fixed rolled mild steel Joist channel,angle or tee sections fixed independently ,with out connecting plates etcconforming to FE 410-W Quality -Aalonwith welding/ rivetingof specifeid shape and necessary civil /PCC wORK(ie 30cm below ground level and 40 cm above level )etc.complete all as specified and as directd.
77Taking down/ dismentling the old / UNSV duct of central AC plant and M&L to assembly/ eroction of GI sheet with C&SS , rectangular / boxed, incls all accessories such as corner, cleat , carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 26 gauge . In Laid Wool installation not less than 30 mmthick over allsurrounding the duct and 15 mm thick cement randering work over / around the complete duct with chicken wire mess of suitable size all is specified and directed. Note: Theinner size ofduct is not less than existing.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail