Tender For Renovation Of Arts Block C Building At Ranchi University In The Campus Of Morabadi Ranchi, Jharkhand ., ranchi-Jharkhand

Building Construction Department-BCD has published Tender For Renovation Of Arts Block C Building At Ranchi University In The Campus Of Morabadi Ranchi, Jharkhand .. Submission Date for this Tender is 10-07-2023. Building Repair Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

38407616
Tender For Renovation Of Arts Block C Building At Ranchi University In The Campus Of Morabadi Ranchi, Jharkhand .
Open Tender
Indian
Jharkhand
ranchi
10-07-2023

Tender Details

Renovation Of Arts Block C Building At Ranchi University In The Campus Of Morabadi Ranchi, Jharkhand .

Key Value

Document Fees
INR 10000 /-
EMD
INR 274000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Renovation of Arts Block ”C”Building at Ranchi University in the Campus of Morabadi Ranchi, Jharkhand .
Sl. No. Item Description
1Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
2Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
3Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
4Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
5Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
6Easing and adjusting door and window shutters with chaukhats in old work complete as per specification and direction of E/I.
7Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
8Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
9Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
10Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
11Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
13Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
14Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
15Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
16Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
18Supplying, fitting and fixing 32mm , thick good quality well dressed and well seasoned sal wood fully glazed shutter in windows with oxidised iron fitting 3mm. thick plain glass fitted with sal wood beads, taxes all complete as per building specification and direction of Engineer - in - charge.
19Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windowswith black board core blended with high qualityphenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
20Providing Toe steel reinforcement of following dia rods as approved design and drawing including carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)
218mm
2210mm
2312mm
24Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled "Z" and mullion steel sections and size as per IS-1038 jointsmet and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I.
25Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
26Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. 600 x 600mm size
27Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
28Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With "A" grade white 15X15cm Tiles.
29Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
30Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
31Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
32Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
33Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
34Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
35Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
36Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red - Area of slab upto 0.50 sqm
37Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
38Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conformingto IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sq.m including pointing the joints with white cement and matchingpigments etc., complete.
39Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size - Size of Tile600 x 1200 mm
40Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.
41Providing and fixing double scaffolding system (cup lock type) onthe exterior side, up to seven story height made with 40 mm diaM.S. tube 1.5 m centre to centre, horizontal & vertical tubes joiningwith cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for workingplatform etc. and maintaining it in a serviceable condition for therequired duration as approved and removing it there after .Thescaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection ofwork at required locations with essential safety features for theworkmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measuredfor payment purpose .The payment will be made once irrespective ofduration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
42Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
43Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of alljoints, corners, junctions of pipes and masonry with polymer mixedslurry.
44Providing & Applying polymer modified, flexible cementatious negativeside waterproofing coating with elastic waterproofing polymers oninterior wall plaster surface in three coats @14.35 kg /10 sqm. onecoat of self priming of cementatious waterproofing polymer(dilutionwith water in the ratio of 1:1) and two coats of cementatiouswaterproofing polymer(dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existingpaint film & loose particles till plaster is visible, complete in all respectas per the direction of Engineer-in-Charge.
45Providing & Applying high quality acrylic modified resin based textureof Dholpur/Red sand stonePattern with anti algae and UV resistanceproperties to be applied as intermediate finish in desired pattern @43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrappingand properly cleaning the surface to remove loose particles from theplaster surface, followed by top coating with Premium Acrylic Smoothexterior paint with Silicone additives of required shade by two ormore coats @ 1.43 litres/10 sqm, complete as the direction ofEngineer -in-Charge.
46Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. Mirrors of 6mm thick glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 600mm x 450mm size
47Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. "P" trap 15 liters C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware ware footrest to be fixed than 50 gms, 15mm PVC connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. 580mm long - With 12.5 lit. low level PVC cistern
48Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan "Parry" or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. Flat back or standard corner (600mm x 350mm)
49Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
50Supplying, amterials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. cover with frame (weight not less than 36kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per soecification and direction of E/I.
51Special type C.P. Bath roomFitting for V.I.P.Buildings(JAL, Jaquar, Mark or Equivalent)
52Pillar cock (Long neck)
53Bib cock (Long Thread)
54Angular stop cock
55Towel Rail 24"
56Soap dish
57Glass Shelf 22"
58Supply C.P. & PVC fittings 100mm dia steel Jali
59Polythene water storage tank of mark with cover and suitable locking system in double layer confirming to IS : 12701-1996 with latest revision
60Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
6175 mm diameter
62110 mm diameter
63Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
64Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes
65Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
6625 mm nominal dia Pipes
6732 mm nominal dia Pipes
68Carriage of materials by mechnical mean including loading at source ,unloading at works site and stacking properly ,labour, POL, etc all complete as per direction of E/I.
69BRICKS
70SAND
71STONE CHIPS
72STONE METAL
73LOCAL SAND
74Point wiring in PVC conduit, with modular type switch :- Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI boxetc as required. Group A
75Twin Control point wiring in PVC conduit, with modular type switch :- Wiring for twin control point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 waywith modular switch, modular plate suitable GI boxetc as required
76Circuit/ submain wiring in PVC conduit :- Wiring forcircuit/ submain wiring along with earh wire with the following sizes ofFR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required
772x1.5 sq.mm.+1x 1.5 sq mm(for toilet switch board +6A socket)
782x2.5 sq.mm.+1x 2.5 sq mm(for switch board & 6A socket)
792x4 sq.mm.+1x 4 sq mm(for AC &16A socket)
80Wiring in existing conduit :- Supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as required 3x1.5 sq mm
81S/F PVC conduit :- Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
8220 mm PVC coduit.
8325 mm PVC coduit.
84S/F Modular type switch/ socket :- Supplying and fixing of following modularswitch / soket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
855/6 amps, one way switch
8615/ 16 amps, one way switch
875/6 amps, 3 pin socket outlet
8815/16 amps, 6 pin socket outlet
89S/F Modular type blankingplate :- Supplying and fixing modular blankingplate on the existing modular plate & switch box excluding modular plate as required.
90S/F Modular boxes, base & cover plate :- Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (78mm x 78mm x 45mm)
91S/F light plug point with modulartype accessories :- Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
92S/F power plug point with modular type accessories :- Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 6 pin 15/16amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
93S/F ceiling rose :- Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/ wooen block including connection etc. as required .
94Erection on incandescent light fitting :- Erection of wall bracket / ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting complete with all accessories including connection etc.as required
95ITC ceiling fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
96S/F T.P. MCB DB :- Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door, Horizontal type
97S/F"C" series,MCB :- Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
986/32 amps, Single pole
9940 amps, TPN
10050/63 amps, TPN
101S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminariewith pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required.
1026/7W LED Round Down light
10318/20W LED Round Down light
104Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1051 run of cable
1062 run of cable
1073 run of cable
108Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade.of following size on wall surface asrequired.
109upto 35sq.mm.(clamped with 1 mm thick saddle)
110Above 35 sq mm and upto 95 sq mm (clamped with MS flat clamp)
111Recess Mounting LED Panel Light 2 x2 (36W)
11216" (400mm)wall mounted fan
113Providing & fitting of LED strip light24 volt DC with IP ;65 RATED IN DIFFERENT COLOURS OF LENGTH 5 MTR AND POWER5w per mtr including driver is 10322part 5 section 7
114NON-SCHEDULE ITEMS Supply, Installation, Testing and commissioning of 1 Elevator(s) Basic elevator dataElevator Type Passenger elevator PWU13/10-19 Product KONE U MonoSpaceNo of Units 1Load & Capacity 884 kg or 13 persons Speed 1 m/sStops & Openings 3 stops & 3 openings, Single entrance car Travel height 7.2 mElevator Grouping SimplexFull Collective Control Well Dimension 2205 mm width and 1800 mm depth (required) Head Room height 4000 mm (required)Pit Height 1525 mm (required) MAP Floor Position Topmost floor (TOP)Car dimensions 1600 mm wide x 1350 mm deep x 2300 mm high Door dimensions 900 mm wide x 2100 mm internal heightDoor type Two-panel centre opening Plain PanelFinishes Car design Midrange Basic SL10Car Panel Finish Brushed stainless SUS304 Handrail Tube D38 (HR61) Silver brushed stainless steel (ST4) at Rear Wall Ceiling & Lighting Square spot, LED Brushed
115stainless steel SUS304 (ST4) Square Spot Light LED STN LCD size [Inch] 5.7Flooring 3 mm Pattern (PVC) Cloud Silver brushed stainless steel AISI304 finishing (ST4) Car Door Finish Brushed stainless steel SUS304 (ST4) Floor number Floor Mark Interfloor distance Landing door material 1-3 0, 1, 2 3600 mm Silver (ST4)Car operating panel 1 Full Height Silver brushed stainless steel ST4AFP with anti-fingerprint coating (ST4) Temperingglass STN LCD black Round surface mounted KDS93Landing Signalization Stainless Steel Segmented LCD display Flush Mounted Tempered glass Round,surface mountedKDS93FeaturesStandard Car Emergency Light Fireman DriveCurtain of Light 169 BeamsAccurate Relevelling, Automatic, Closed Door Additional Emergency Rescue Device with audio announcer2 Way Dedicated Intercom Nudging serviceAttendant ServiceSquare Spot Light LED
116Add 18 % GST
117Add 1% Labour Cess
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail