| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables, pole foundation, etc and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches exceeding 1.5m in depth and not exceeding 3 m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables, pole foundation, etc and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/loose soil, complete all as specified and as directed. |
| 4 | Removing excavated material, soils, n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 5 | M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand,(approved source) as per standard practice with proper compaction complete all as specified and directed. |
| 6 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 7 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 4 sqmm, 2 core including taking out the unserviceable cable complete all as specified and as directed. |
| 8 | S&F 3mm thick aluminum composite panel sheet, high intencity reflective sheet including writing letters fixed with angle iron of size 65mm x 65mm x 6mm including necessary earth work and PCC foundation (type C2, 1:3:6) of minimum 0.35meter height positioned and fixed with suitable nuts, bolts, washers etc.complete all as directed. |
| 9 | S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer, including necessary dismantling the unserviceable MS work complete all as specified and as directed. |
| 10 | Supply, spreading and levelling roung shape 40mm stone aggregate in around E/M installation complete all as directed. |
| 11 | M&L steel tubular swaged poles, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 meter long, inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surfaces and making strip 150mm wide in alternate layer of black and yellow syntheic enamel paint upto 1.5 metre above Coping, including dismanting old unserviceable pole, complete all as specified and as directed.(The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161)NOTE : Earthwork, cement concrete will be measured and paid seperately under appropiate items |
| 12 | M&L for PCC (1:4:8) type-D2withusing 40 mm graded crushed stoneaggregate as in in foundations,filling and mass concrete ete complete all as specified and as directed. |
| 13 | M&L for PCC (1:3:6) type-C2withusing 40 mm graded crushed stoneaggregate as in mass concrete etc complete all as specified and as directed. |
| 14 | M & L Plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate)as in coping of poles including all necessary formwork complete all as specified & as directed. |
| 15 | S&F in repair, LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & as directed. |
| 16 | M&L House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos900 bends. M.S.hook and stay or guy including necessary dismantling the unserviceable service bracket complete all as specified and as directed. |
| 17 | M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, burieddirectlyin ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connectedtoGI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level ofthe Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with commonSalt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6(20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, including necessary dismantling the unserviceable earthing complete all as specified and as directed. |
| 18 | Supply, install, testing and commissioning of LT outdoor typefeeder pillarpanel box(B = 1.25 Mtr, H = 0.85 Mtr, D = 0.60), 3 Phase 4 wire, CPRI approved, floor mounted, totally enclosed, dust and vermin proof, openablefrom both front and rear side, made out of 3.15mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50 X 50 X 6mm angle ironframe work of 95cm long ( 65cm above ground and 30cm below ground) having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts , springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz , 3 phase4 wire system, coloured heat shrinkable sleaving, internal connection should be provided with aluminium strip of suitable size and inxcluding necessary grouting/ foundation (using type C2, 1:3:6), necessary earth work and complete all as required at site and comprising following:-(a) Aluminium Bus-bar 250 Amps, supported on hygroscopic fibre and brass screws for mounting =04 Nos.(b) MCCB 160 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 36 KA-01 Nos(Incomming)(c) MCCB 125 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 25 KA-02 Nos(Outgoing)(d) MCCB 32 Amps, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rapturing capacity 16 KA-01 Nos(Outgoing)(e) 3 Phase digital multi function meter, model A, Class 1, 5 Amps with relay Vega Series: 01 Nos(f) Indicating Lamp 240 Volts LED type: Set of three |
| 19 | Demoliation Brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed |
| 20 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6 complete all as specified and as directed |
| 21 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as directed. |
| 22 | M&L for 15mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm&5mm)seperately mixed with water proofing compound in top layer as per manufacturer\"s instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 23 | Supply only liquid water proofing compound complete allas specified and as directed. |
| 24 | M&L Rendering 10 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 25 | M&Lrendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface fair and evenwithout using extra cement.complete all as specified and as directed. |
| 26 | M&L preparing newly plastered or unplastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed. |
| 27 | M&L preparing newly plastered or unplastered surfaces of wall and applying three coats of white washing complete all as specified and directed. |
| 28 | M&L applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete allas specified and as directed. |
| 29 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as directed. |
| 30 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and as directed. |
| 31 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 32 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, from unframed work complete all as directed.. |
| 33 | S&F Steel work in tubular trusses/purlins/rafter/post etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 34 | M&L preparing new Steelsurfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 35 | Demoliation of cement concrete of any description and in any position not otherwise specifically provided for complete all as directed. |
| 36 | M&L Cement concrete type B0, (1:2:4) (using 12.5 mm graded crushed stone aggregate)as in roof padding,roof kerbs or mud stops, rounded or chamfered on edges for roof surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 37 | M&L water proofing treatment to flat roofs and edges, applying3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.60 Kgs per Sqm reinforced with non-woven polyester febric weight not less than 150gms per Sqm over a coat of bituminousprimer@ 0.3Kg/Sqm, after necessary cleaning the surfaces.Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed. Note : (a) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (b) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction. |
| 38 | M&L for 15mm thick cement mortar plaster (1:4) on green concrete roof surfaces faces mixed with and including liquid water proofing componud as per manufacturers instruction, finishing the surface fair and even without using extra cement complete all as specified and as directed. |
| 39 | M&L One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions complete all as specified and as directed. |
| 40 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each. complete all as directed. |
| 41 | Taking down chowkat with shutter (without taking off shutter from the frame) exc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed. |
| 42 | M&L second class hardwood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed. |
| 43 | S&Fmild steel hold fasts; for securing chowkhats and similar small articles conforming to Fe-290 Gde-E-165 incuding treating hold fast with tar or coal tar black paint, sandingcomplete all as specified and as directed. |
| 44 | M&Lproviding plain cementconcrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings,fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 45 | M&L Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed. |
| 46 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 47 | S&F 150mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 48 | S&F 300 mm aluminium alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy fixed complete all as specified and as directed. |
| 49 | S&F 100 mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed. |
| 50 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified and as directed. |
| 51 | S&F Factory made second class hardwood 30mm thick Glazed and skeleton shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of windows, ventilators, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b) supplied and fitted to chowkats complete all as specified and as directed. |
| 52 | S&F 75 mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed. |
| 53 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads complete all as specified and as directed |
| 54 | S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed |
| 55 | M&L for preparing new wooden surfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 56 | Demoliation Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed. |
| 57 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 58 | M&L for Pre polished coloured chequered cement concrete tiles 25 cm x 25 cm x 25 mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over cement screed 15 mm thick in cement mortar 1:6 complete allas specified and as directed. |
| 59 | M&L Machine cut kota stone slab flooring 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including cement screed 20 mm thick 1:6 complete all as specified and as directed. |
| 60 | M&L Preparation of old decorated plastered/unplasteredsurfaces of walls by using electric sander machine or steel wire brushing, scraping down smoke soot,moulds, moss & efflorescent salts, trading oil or greasy spots and applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqmcomplete all as specified and directed. |
| 61 | M&L Preparation of old decorated plastered/unplasteredsurfaces of walls by using electric sander machine or steel wire brushing, scraping down smoke soot,moulds, moss & efflorescent salts, trading oil or greasy spots and applying one coat of white wash complete all as specified and directed. |
| 62 | M&L Preparation of old decorated plastered/unplasteredsurfaces of celings by using electric sander machine or steel wire brushing, scraping down smoke soot,moulds, moss & efflorescent salts, trading oil or greasy spots and applying one coat of white wash complete all as specified and directed. |
| 63 | M&L for preparation of old painted wooden surfaces of any description,over 10cm in width or girth, not otherwise described,and applying one coats of synthetic enamel paint (1st quality) complete all as specified and directed |
| 64 | M&L for preparation of old painted steel surfaces of any description,over 10cm in width or girth, not otherwise described,and applying one coats of synthetic enamel paint (1st quality) complete all as specified and directed |
| 65 | M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and as directed |
| 66 | Supply, install and testing 5.5KW/7.5HP, 415 VOLTS, 3 PHASE, 50 Hz, electric driven submersible pump set mix flow type with high graded CI bowl, stainless steel shafts, bronze impeller etc of pump outlet dia 80mm capable to deliver 240-471 LPM, clear water at 26-61 meter head, complete including necessary connection including steel chain made out of 6mm dia (size 20mm x 38mm) with PVC coating of lenght eual to the lenght of column pipe for holding submersible pump set/column pipe including necessary MS holding clamps, nuts, bolts etc complete all as specified and directed. |
| 67 | Supply and lowering of 80mm bore GI pipe Heavy duty, flanged end, column pipe(length of each pipe 3 mtrs)including jointing/making with cutting grooves at flange for passing submersible clamp including clamp, bolts nuts, washer and rubber gasket complete all as specified and directed. |
| 68 | S&F CI Reflux/ Non Return valve single door pattern with flanged ends PN-1.6 confirming to IS: 5312, ISI marked of size 80mm dia bore with bypass arrange ment including all fixing accessoriestype Cast iron flanged end with nuts, rubber gasket, bolts (full threaded), nuts & washers complete all as specified and as directed. |
| 69 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sq mm 3.5 core, laid in trenches/fixed on walls/pole, laid in ducts/pipe including suitable size glangs, lugsas required complete all as specified and as directed. |
| 70 | Supply, laying and fixing and testing PVC insulated submersible copper cable 6Sqmm, 3 Core, flat LT 1100 volts grade cable, heavy duty copper conductor and overall served with an outer sheathed,fixed along the column pipeto connect pump set complete all as specified and directed. |
| 71 | M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connectedtoGI Earth Strip 25 x 4 mm drawn through and including GI Pipe 32 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level ofthe Building where Main Switch/DB situatedby means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and directed. |
| 72 | Supply, installing, commissioning and testingof factory made LT Panel board, TPN, 415 Volts, cubical type, floor mounted, outdoor type, suitable for 415 volts AC, CPRI approved factory made, double door, dust and vermin proof IP 65, fabricated out of CRCA sheet of not less than 3.15mm thick with 2mm thick for internal compartment dully powder coatedtand supportedby 50 mm x 50 mm x 6 mm MS angle iron frame with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch andfuse and the panel board shall be provided with proper ventillation including suitable size of cable alloy aluminum busbar suitable with suitable connections from MCCB;s outgoing to main busbar shall be carried out with TPN aluminum busbar of suitable rating and connection from main busbar to out going MCCM;s (intake point) will be carried out with TPN aluminum busbar as per MCCB rating dully insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulatorsincluding necessary earth work and PCC foundation(type C2, 1:3:6) of minimum 0.35meter height positioned and fixed with suitable nuts, bolts, washers etc. to MC pedestal andcomplete all as specified and directed and comprising of the following :-BUS BAR:-(i) Aluminum Bus bar 200 Amps, supported on non hygroscopic fibre and brass screws for mounting: 4 Nos.(ii) INCOMMER:-(a) MCCB 63 Amps, 4 Pole, 50 Hz, 415 Volts with fixed thermal and fixed magnetic setting having rapturing capacity 16 KA -01 Nos(iii) OUTGOING:-(a) MCCB 63 Amps, 4 Pole, 50 Hz, 415 Volts with fixed thermal and fixed magnetic setting having rapturing capacity 16 KA -01 Nos(b) Star Delta Starter suitable for 3 Phase, 7.5 HP Submersible pump: 2 Nos(c) Indicating Lamp 240 Volts LED type, R, Y, B: Set of three (d) Digital Ammeter of size 100mm x 100mm, 0-300 Amps including CT having CTR 200/5, and Voltmeter 0-500 Volts SIF 96: 01 Nos |
| 73 | M&L Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed. |
| 74 | Supply, installation, testing and commissioning oif maintenance free chemical earthing station using six spikes 17.2 mm dia, 3000 mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 micrins) meeting the requirements of under writers laboratories (UL) 467-2007 or latest with 250 mm long copper strips of size 50 x 3 mm, exothermally welded on top of elecrode complete including augering (boring) 100-125 mm dia hole as required for electrode in any type of soil and back filling with carbon based ground enhancing compound (GEC) compound (withminimum qty 35 Kg per electrode) conforming to IEEE/BS standrads including pit cover light weight made out of high quality polymer with lid made of HDG steel complete with cover complete all as directed.Note:- (i) The work of earthing shall be carried out by authorised trained rep of OEM.(ii) The acceptable earth resistance at earth busbar/ test point shall not be more than 1 Ohm. (iii) Make : JEF Techno Solution Pvt Ltd/Tercel/McML/Macmet/Erico/Reslow JK earth electrode. (iv)Loop conductors with 32 x 6 mm strip shall be measured and paid seperately. |
| 75 | M&L Earth continuity conductor or main earthing lead fixed to wall/roof with saddles/PVC insulation and fixing screws or any other indicated situation for loop earthing etc. as requiredusing20x3.15mm copper strip complete all as specified and as directed. |
| 76 | M&L Earrth continuity conductor or main earthing lead fixed to wall/roof with saddles/PVC insulation and fixind screws or any other indicated situation for loop earthing etc. as requiredusing32x6mm copper strip complete all as specified and as directed. |
| 77 | M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed. |
| 78 | Surface dressing n exc 15 cm deep, in soft/loose complete all as directed. |
| 79 | Spreading and levelling of soil in layers n exc. 25 cm thick,well ramming including watering as required complete all as directed.Note: (i) Earth obtained from Excavation shall be used in item. (ii) Payment shall be done on the basis of compacted thickness as defined in MES SSR 2010 (Part II) Clause No 3.6. |
| 80 | M&L Hardcore using Broken stone or bouldersof gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 81 | M&L 75mm thick PCC (1:4:8) type D2(40mm graded stone aggregate) as insub base of floor finished even and fair complete all as specified and as directed. |
| 82 | M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.Note:- Reinfocements will be measured and paid seperately under appropiate item |
| 83 | M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and as directed.Note:- Reinfocements will be measured and paid seperately under appropiate item |
| 84 | M&L Reinforced cement concrete (nominal mix)Type B1 1:2:4(20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.Note:- Reinfocements will be measured and paid seperately under appropiate item. |
| 85 | M&L Reinforced cement concrete (nominal mix)Type B1 1:2:4 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.Note:- Reinfocements will be measured and paid seperately under appropiate item |
| 86 | M&L Formworkto sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. flat, roughed finished surfaces, complete all as specified and as directed. |
| 87 | M&L Formwork to sidesto of pillars, posts, struts, piers, columns and stanchionst, roughed finished surfaces, square, rectangular or polygoan complete all as specified and as directed. |
| 88 | M&L Formworkto sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.. flat, roughed finished surfaces, complete all as specified and as directed. |
| 89 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping).. flat, roughed finished surfaces, complete all as specified and as directed. |
| 90 | M&L Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide roughed finished surfaces, complete all as specified and as directed. |
| 91 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed |
| 92 | M&L TMT bar 10 mm diaand over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and as directed. |
| 93 | M<MT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and as directed. |
| 94 | M&L TMT bar 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and as directed. |
| 95 | M&L prepration of new plastered surfaces ofwalls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 96 | M&L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed. |
| 97 | M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed. |
| 98 | M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. |
| 99 | M&L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed. |
| 100 | M&L water proofing treatment to flat roofs and edges, applying3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.60 Kgs per Sqm reinforced with non-woven polyester febric weight not less than 150gms per Sqm over a coat of bituminousprimer@ 0.3Kg/Sqm, after necessary cleaning the surfaces.Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed. Note : (a) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (b) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction. |
| 101 | M&L for 15mm thick screed bed or bedding layer in cement mortar plaster (1:4) for laying of APP membranemixed with liquid water proofing componud as per manufacturers instruction complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 102 | M&L applying Two coats of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions complete all as specified and as directed. |
| 103 | M&L Non skid coloured tiles7 to 8mm thick (square/ rectangular) area of each tiles exc o.11 Sqm but not exc..18 sqm in flooretc set and jointed in neat cement slury over and including cement screed 15 mm thick 1:6 complete all as specified and as directed. |
| 104 | M&L colouredglazed ceramic tiles coloured in vertical surfaces 350x250x7mm/450x350x 7mm thick, set and jointed in neat cement slurry and pointed in white and colour cement to match shade of tiles including cement screed 10 mm thick 1:4 complete all as specified and as directed. |
| 105 | S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, complete allas specified and as directed. |
| 106 | S&F 20mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, complete allas specified and as directed. |
| 107 | S&F Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) (conforming to IS 12701-1996) multi layer hoisted and fixed in position 1000 ltrs capacity complete all as specified in SSR Part I, including writing date of cleaning on tank using stencil in white syntheic paint height not exc 30cm(\"DATE OF FIXING: DATE\") complete all as specified and as directed |
| 108 | S&FSteel ventilator with top hung shutter including hinges,one coat of red oxide, zinc chrome primer, steel peg stay, complete complete all as specified and as directed. |
| 109 | S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed |
| 110 | S&FStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 111 | S&F 200mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 112 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed. |
| 113 | S&F, aluminum anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed |
| 114 | S&F 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 115 | S&F vitreous china wash basin, white, flat back, size550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed. |
| 116 | S&F Vitreous China, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 117 | S&F 10 litres capacity,PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe complete all as specified and directed |
| 118 | S&F 15mm bore chromimum plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed foriron pipe or for brass ferrule and fixed completeall as specified and directed |
| 119 | S&F15mm bore Angular Stop cock with Wall Flange and fixed complete all as specified and as directed. |
| 120 | S&FLiquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/ plastic cleats.(Minimum weight 105gms) complete all as specified and as directed. |
| 121 | S&F PVC connection 15mm size with PTMT nuts, 450mm length complete all as specified and as directed. |
| 122 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 123 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 124 | S&F 75mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 125 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 126 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 127 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilingscomplete all as specified and as directed. |
| 128 | S&F 75mm borePVC (SWR) vent cowl complete all as specified and as directed. |
| 129 | M&L 100mm thick PCC (1:4:8) type D2(40mm graded stone aggregate) as insub base of floor finished even and fair complete all as specified and as directed. |
| 130 | S&F 32mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid in trenches, road crossing, drain crossing, under floor or fixed to iron structures/poles complete all as specified and directed. |
| 131 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 4 sqmm, 2 core complete all as specified and as directed. |
| 132 | M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, burieddirectlyin ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connectedtoGI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level ofthe Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with commonSalt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6(20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion,complete all as specified and as directed. |
| 133 | M&L for concealed point wiring for light/fan points controlled by one, one way switch with two single core 1.5 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, fan regulators, etc. confirmingto IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for Modularboxes & making good to walls, floors etc. complete all as specified & as directed Note:- (i) Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles. |
| 134 | S&F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified anddirected. |
| 135 | S&F LED lights fitting 1x 20 Watt, 220Volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 136 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 137 | S&F ceiling rose, PVC/ polycarbonate, isolated body, three terminals, complete all as specified and directed. |
| 138 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 139 | S&F LED street light fitting 35 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified anddirected. |
| 140 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 protection, doubledoor, Single pole & neutral, complete including blanking plates as required &flush to wall/other surface complete all as specified and directed. |
| 141 | S&F MCB, SPN, C Series 240 Volts, 32 Amps 50 HZ, 10KA complete all as specified and directed. |
| 142 | S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |