Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-07-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-07-2023 |
| 2 | 04-07-2023 | AMDT1 | Date | 18-07-2023 |
| Sl. No. | Item Description |
| 1 | Taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified. |
| 2 | Taking down chowkatswith shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) |
| 3 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and removing from site |
| 4 | Taking down shutters refixing in same openingbut area exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified. |
| 5 | S&F PVC doorframe of size 50x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as perspecification and designs |
| 6 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MStubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC’C’ channel heaving a PVC sheet strip of 20mm width suck inside |
| 7 | S&F Aluminium handle cast type anodized 125 mm long |
| 8 | S&F Aluminium anodized barrel tower bolt of extended section and fixed 200 mm long |
| 9 | S&F 75 mm long butt hinges almiunium alloy with galvanised mild steel hinges pin, anodised and fixed |
| 10 | S&F 100 mm long butt hinges almiunium alloy with galvanised almiunium hinges pin, anodised and fixed |
| 11 | S&F 100 mm long mild steel butt hinges. |
| 12 | S & F pressed steel door frames with one or more rebates including necessary fixing lungs lock strike plate etc complete all as specified size of frame 105 x 60mm all as specified and directed by Engineer - in - Charge . |
| 13 | S & F pressed steel door frames with one or more rebates including necessary fixing lungs lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed by Engineer - in - Charge . |
| 14 | M&L Cement concrete 1:2:4 type B–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed by Engineer - in - Charge. |
| 15 | S&F 35mm thick 2ndclass hard wood glazed Skelton shutters open rebated and prepare to receive glass gauges etc withoutsash bars edges of gramng plainchamferedor roundedfluted without and mixed beadsfor securing gases etc size ofchambers as specified in SSR Part I sector 8-20 (a) fitted tochowkat. |
| 16 | S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated |
| 17 | S&F Aluminium anodized barrel tower bolt 150 mm long. |
| 18 | S&F Aluminium anodized handles 200 mm oval type anodised complete all as specified and directed. |
| 19 | S&F Aluminium anodizedSliding door bolt 300 mm long anodised complete all as specified and directed. |
| 20 | S&F MS flat 25x3mm thick as in hold fast confirming to Fe410-0 & Fe 310-0 |
| 21 | S&FStainless steel wire cloth 0.36mm nominal dia of wire and average width or aperture 1.40mm |
| 22 | S&F in repair Stainless stee wire cloth 0.36mm nominal dia of wire and average width or aperture 1.40mm |
| 23 | Hacking out old broken glass (any size,thickness,quality or description from metal frame including punching or drilling out old glazing pins/spring clipscomplete all as specified & directed by Engineer -in-charge. |
| 24 | S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 sqm in each pane |
| 25 | S & F 3 mm thick Figured glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified. |
| 26 | S&F in repair MS 300mm ordinaryrat tail rod pattern springs including roller and roller plate complete. |
| 27 | M&L preparing surface of wood and woodbased surface new on any description not other wise described over 10cm with or grith and applying two coat of synthetic enamel paint over a coat of pink primer. |
| 28 | S&F MSsquare bar for window guard bars fixed indenpendently welded to ventilators and windows etc and similar article. |
| 29 | S&F steel ventlators with top hung shutters including box type hinges, steel peg stay complete |
| 30 | S & FSteel windows with side hung shutters including box type hingeswith steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded (Glazed steel window) |
| 31 | S &F steel windows with side hung shutters including box type hinges , steel handle with fixing arrangement for wire gauge windows etc complete (wire gauge steel window) |
| 32 | M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth all as specified. |
| 33 | Taking down aluminium door shutter , Refixing in the same opening after tightening of members ,refixing of glass panes and rubber bids inluding adjusting of old hydraulic door closer complete. |
| 34 | S&F anodised aluminium Powder coated frame for doors , window , ventilators with with one or more rebate including joiing cleat forfixing etc . complete all as specified. |
| 35 | S&F anodised aluminiumPowder coated grill weight not less than 1.50 Kg/Sqm in window , doorsor ventilator includingfixing material complete all as specified and as directed by Engineer in charge. |
| 36 | S&F sheet glass 4.8mm thick ordinary quality and fixed in alum section including solar control film 25 micron reflective type sticked to glass panes as per instruction of manufacturers in squares not exceeding 0.50 sqm in each pane |
| 37 | S&F in repairs aluminium (die cast) body,door closer hydraulically regulated designation No. 3 , universal type , suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed. |
| 38 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless stell cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, including making good existing floor after installation of floor spring. |
| 39 | M&L in repairs AluminiumMotrice lock4 levers and 75mm size for aluminium doors |
| 40 | S&F for 150mm floor door stopper of aluminium alloy body and tongue,anodised with hard drawn steel spring,fixed in floor. |
| 41 | Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. |
| 42 | M & Lfor rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement. |
| 43 | M & Lfor rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement. |
| 44 | M&L rendering10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement. |
| 45 | M&L rendering15 mm thick rendering in cement mortar 1:3 on roof surfacesfinishing even and smooth without using extra cement complete all as specified . |
| 46 | M & L Washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 (1 cement :1/2 coarse sand 2 : stone chipping 10 mm normal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to be expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately). |
| 47 | Forming groove of uniform size 12 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using aluminium channel size 12X15X0.50 MM thick, nailed to the under layer and finishing the groove complete as per specification and direction of the Engineer-in-Charge. |
| 48 | Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP |
| 49 | M&L for two coat of cement base paint over a coat of alkali resistant cement primeron newly plastered surface including preparation of undecorated surface complete all as specified and as directed |
| 50 | M& L for two coat of oil bound distemper on new plasterd wall surfaces of walls paint over 3mm thick wall care putty includingnecessary preparation of surfaces all as specified. |
| 51 | M&L preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling. |
| 52 | M & L one coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge . |
| 53 | M&L forpreparation of old decorated surface of ceilingand applying one coat of Oil bound distemper on ceiling. |
| 54 | M & L one coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge . |
| 55 | M&L for preparation of old distempered surfaces of walls by washing, rubbing down, stopping nail holes, fillings cracks with putty etc and applying one coat of oil bond distemper on walls. |
| 56 | M & L applying one coat of cement base paint on old decorated plastered surfaces of walls including preparation of surfaces by washing, rubbing down and stopping of painted surfaces complete all as specified and directed by Engineer - in – Charge |
| 57 | M & L Preparation of Old plastered surfaces by removing old treatment and applying two coats of exterior grade wall putty and making it smooth with sand paper by mechanical method then applying one coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified and as directed by Engineer-in-Charge. |
| 58 | M & L for preparation of old painted wooden surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . |
| 59 | M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . |
| 60 | M & L in repair Shotcreting 25MM thick in RCC Chajjas/facia etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characteristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria),width not less than 0.5m to 1.50 m including the cost of certering and shuttering at edges and corners/ etc and including Fixing of hard drawn steel wire fabric as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mmaverage thicknessfrom Chajjas/facia with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.Note:- Hard drawn steel wire fabric shall be measured paid seprately. |
| 61 | Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mmaverage thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.Note:- Hard drawn steel wire fabric shall be measured paid seprately. |
| 62 | S&FHard drawn steel wire fabric not exc 2.5 KG cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntall as specified & directed by Engineer-in-Charge. |
| 63 | M & L 5mm thick rendering in Cement Mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cementcomplete all as specified and directed by Engineer - in - Charge . |
| 64 | Providing and applying microfiber reinforced UV resistant Acrylic polymer coating three coats having solid contents 69% polymer content 35% & Tensile strength 2.6N/mm2 of Dr. fixit Newcoat/stat/parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign contaimnant filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. fixit Primeseal.polyester reinforced fiber net laid on the surface after the first coat and all the joints of brick is repaired by polymer based mortar.Undulation on the surface repair before executing the water proofing treatment complete all as specified & directed by Engineer-in-charge.Note : The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer instructions & as directed by Engineer-in-Charge. |
| 65 | Dismantling structural steel work including doors,gates but excluding framed truss etc. |
| 66 | S & F structural steel work rolled mild steel joist, channel,angle,or Tee sections, fixed independentlyconforming toFe 410-W all as specified . |
| 67 | S & F framed work such as grills,cooler stand ,ladder grating and sun shed etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming toFe 410-0 or Fe 310-0 all as specified . |
| 68 | S&F 25 mm dia drapery curtain rod with decorative end knobs complete with brackets and fixed to walls complete all as sp & dir . |
| 69 | Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices. |
| 70 | S&F glazed ceramic colouredtiles joint free 350x250x7mm/450x350x7mm square or rectanguleras on walls etc set and jointed in neat cement slurry and pointed in whiteor coloured cement to match over 10mm thick rendering in CM 1:4 |
| 71 | M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick( square /rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm th screed bed in CM 1:6 complete all as specified and directed by Engr in Charge. |
| 72 | Ditto all as above but as in skirting over 10 mm cement mortar backing coat ( 1:3) complete all as specifed and directed. |
| 73 | M&L cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate as in floors 25 mm thick for tilesall as specified.& directed by Engineer -in-charge.. |
| 74 | M&L 16-18mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and likein cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 75 | Cutting ,grinding ,cleaning and treating the surface of existing kota stone flooring with beeswax polishing complete as directed by Engr-in-Charge. |
| 76 | M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing ,Chamfering and nosing complete all as directed. |
| 77 | M & L Machine cut kota stone slab18 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing,Chamfering and nosing complete all as directed. |
| 78 | Demolitionof cement concrete ( un re-inforced) of any description in ground floor and pavings Nexc15 cm thickness (below or above GL) |
| 79 | M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge. :- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c)Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d)Apply first coat of two component modified polymer coating on the horizontal and verticle surface(e)Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:5:10 over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete as specified Manufacturer. Make:- Dr. Fixit/Fosroc/STP Note: (i)The treatment shall be carried out as per the manufacturers instructions and as directed by the Engineer in charge.The name of firm shall be got approved from CWE before carrying out the work.(ii) Plaster shall be measured and paid separately.(iii) PCC filling under sunken area will be measured & paid separately |
| 80 | M & L PCC (1:5:10)using 40mm graded burnt bricksaggregate as in foundation filling & mass concrete or as in sunkenfloor complete all as specified & directed by Engineer-in-charge |
| 81 | Rendering to sunken slab floor and vertical sides 15mm thick in CM 1:3 using WP compound |
| 82 | Dismantling water tanks and removing to store of exc 250 nexc500 ltr capacity |
| 83 | Dismantling water tanks and removing to store ofexc 500 nexc1000 ltr capacity |
| 84 | S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge . |
| 85 | S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge . |
| 86 | Disconnecting existing tanks of (exc 500 &1000 litres in capacity), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 87 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulated pipes etcfor exc 500 &n exc 1000 ltr capacity Tank.. |
| 88 | S&F 20mm Ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed. |
| 89 | S&F in repair 20mm Ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed. |
| 90 | S & F in repair 15mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe or wt 0.68 kg specified in SSR part Iand fixed all as specified . |
| 91 | S & F in repair 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe or wt 0.68 kg specified in SSR part Iand fixed all as specified . |
| 92 | S & F in repair 15mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe or wt 0.68 kg specified in SSR part Iand fixed all as specified . |
| 93 | S & F in repair 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe or wt 0.68 kg specified in SSR part Iand fixed all as specified . |
| 94 | S&Fin repair PVC low level flushingsystem 10 Ltr capacity with flush pipe complete as approved by Eng-in charge. |
| 95 | S&F in repair Viterous China squating pan Orrisa pattern size 580/440mm wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) with plastic seat cover. |
| 96 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe,anti-syphonage pipe, sheet cover complete. |
| 97 | S&F in repair plastic water closet seat, white closed patern withflat bottom and cover and mild steelcromium plated or aluminium hinging device |
| 98 | S&F repairs vitreous china Half stall urinals flat back white minimum with grating and union for discharge pipe ,providing & fixing plugs, bedding urinal against wall in CM 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified. |
| 99 | S&F in repair 600mm x 450mm beveled edge mirror of selected quality glass on 6mm thick commercial plywood and fixed wooden plugs with chromium plated brass screw and cup washes fixed in repair. |
| 100 | S & F repairs 15 mm bore concealed stop cock cast copper alloy screwed down high pressurewith crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (Concealled type) |
| 101 | S&F in repairs 15mm bore stop valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. |
| 102 | S & F in repairs 15 mm bore bib tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified. |
| 103 | S/F in repairs pillar taps 15mm borefancy type chromium plated cast copper alloywith capstan heads scre-wed down high pressure with or without lettered hot\" or\"cold\" with long screwed shanks and fly nuts screwed for iron pipe . ISI marked |
| 104 | S&F in repairs for 15mm dia Bib tap fancy type standard of PTMT any colour high pressure screwed for iron pipe and fixed complete as in repair (Minimum weight 15mm-105 gms) all as specified and directed. |
| 105 | S&Fin repairs for 15mm dia angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed complete as in repair (Minimum weight 15mm-105 gms) all as specified and directed. |
| 106 | S&Fin repair swiwelshower of PTMT (min wt 40 gms) any colour for fixing with 15 mm pipeincld shower arm15 mm size , 195 mm long with bend of 45 degree Flange of PTMT . |
| 107 | S&Fin repair brass chromium plated shower Rose 125mm size with swivel joints,any size, incl shower arm fixing to pipe or union complete all as specified and directed by Engr-in-charge. |
| 108 | S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engr-in-charge.Make ESS ESS cat part No.- C-211A |
| 109 | S&Fin repairs Sink mixer with swinging spout(wall mounted model)Chromium plated brass with connection and nut complete all as specified and directed by Engr-in-charge. Make- ESSESS Cat part No DE-12 or equivalent to Parryware/nirali/prayag |
| 110 | S&F in repairs brass chromium plated wall mixer for mixing hot & cold water with provision for overhead shower with 140mm long bend pipe and wall flange screwed down for iron pipe and fixed as directed by Engr-in- charge.Make:- ESS ESS cat part No.- C-216D |
| 111 | S & F in repairs Grating doom 125 mm dia with waste hole ofPTMT ( Min wt 40 gm ) |
| 112 | S&F in repair PVC connection both side brass unions internal for size 15mm dia and 450mm long all as specified and directed by Engineer-in-Charge. |
| 113 | S&F in repair PVC waste pipe 32mm dia & 90 cm long |
| 114 | S & F in repairsfor Cast iron nahani trap 75mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) |
| 115 | S & F in repairsfor Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) |
| 116 | S & F in repairs glass corner shelf assembly fancy type made 8 mm thickn sheet glass of size 300x300mm fixed with \"F\" or \"D\" type brass CP brackets complete all as specified. |
| 117 | S & F in Repairs towel rails 16 mm dia 600 mm long superior quality brass chromium plated fancy type Complete all as specified fixed in repairs. |
| 118 | S&F Chromium plated health faucet 1 mtr long fixed with screws complete all as specified and directed. |
| 119 | S&F EWC Jet spray complete all as specified and directed. |
| 120 | S&F in repair Vitreouschina wash basin white flat back size 550x400 mm including brackets exceeding taps waste chain and plug and porcelain stopper fixed in repair |
| 121 | S&F in repairs kitchen sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets andonnecting union to pipe overall size 915mm x 460mm bowl size 410mm x30mm x 160mm |
| 122 | S&F in repairs Stainless steel utensil rack of size 750mm x 600mm, made out of 1mm thick stainless steel sheet of 1st quality as per sample kept in GE’s office (weight Appx 10Kg) supplied and fixed complete all as specified and directed by Engineer-in-Charge. |
| 123 | S&F in repairs PVCbathroomcabinet mirror 450 x 350 mm complete all as specified and directed by Engr-in-charge.Make:-Prayag cat part no551/polytuf/shakti/pearl as approved by GE. |
| 124 | Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store |
| 125 | Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store |
| 126 | Taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store |
| 127 | Supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to wallall as specified & directed by Engineer-in-charge. |
| 128 | Fixing only mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by Engineer-in-charge. |
| 129 | Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by Engineer-in-charge. |
| 130 | Fixing onlymild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by Engineer-in-charge. |
| 131 | Supply & fixing mild steel tubes of size 25 mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by Engineer-in-charge. |
| 132 | Fixing mild steel tubes of size 25 mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified & directed by Engineer-in-charge. |
| 133 | Dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by Engineer - in - Charge . |
| 134 | S & F PVC(SWR) 110 mm bore Pipes single socketed in any length with rubber ring joints,laid in trenches or in floors all as specified and directed by Engineer - in - Charge. |
| 135 | S & F PVC(SWR) 75 mm bore Pipes single socketed in any length with rubber ring joints,laid in trenches or in floors all as specified and directed by Engineer - in - Charge. |
| 136 | S&F PVC (SWR)branch pieces single /double (equal or unequal) ordinary or inverted with parallel branches 110mm bore |
| 137 | Ditto all as above but 75 mm bore. |
| 138 | S&F PVC(SWR) bend ( any radius) dimenshing pieces or tappers ( large bore measured) 110mm bore |
| 139 | -ditto- all as above but75 mm bore |
| 140 | S & F PVC(SWR) Vent cowls 110mm bore all as specified and directed by Engineer - in - Charge. |
| 141 | M & L in repair providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick one decorative lamination sheet consisting of carcass 18mm thick PVC Sheet & provision of shutters made out of 18mm thick one side decorative laminated PVC sheet all required brackets SS screws etc.The panels shall be fabricated using adhesive and screws where ever required. all the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per make and specification mentioned as drawing and specification approved by Eng-in-Charge. |
| 142 | M & L in repair cubboard with prelaminated Block board one side with decorative choice laminations exterior grade 18-19mm allas specified by Engr-in-charge |
| 143 | S&F Magnetic catcher fixed in with nut,screw washer complete all as specified and directed by Eng-in Charge. |
| 144 | S & F 100mm extuded,brass handles,fabricated type polished for cabinet shutters completeall as specified and directed. |
| 145 | S & F for solid PVC frame (single revated) of size 60mm x 30mm made out of solid pvc foam with homogeneous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK Screws complete all as specified and directed by Eng-in -charge. |
| 146 | S & F Continuous (piano) hinges, brass, bright finish or electro galvanised all as specified. |
| 147 | S & F Factory made prefabricated pressed steel door frame made out of mild steel 1.25 mm thick grith of frame 185 mm including necessary MS rawl plug/bolt and fixing 75mm long butt hinges medium weight cold rolled mild steel etc and shutter including stiffeners made out of mild steel sheet1.25 mm thick cut to size, holes punched and welded seams including bending or turning up all around, mitredangle etc as required with locking arrangement using mild steel mortise lock 4 leaverswith 2 Nos of keys of size 100mm (Make Godrej/Harison /Navtal) including MS chromium plated handle and 2 Nos MS locking rods out of 8mm dia not exc 1000 mm long fixed to mortise lock and handle with necessary bolts and nuts covered by MS sheet 1.25 mm thick complete includign two coat of synthetic enamel paint over a shop coat of zinc chromateprimer on interior surface ( not visible from front ) and hammer tone paint on exterior surface (visible from front ) and including taking down the existing frame and making good the surface of frame complete as per Godrej Pattern all as specified and directed by Engr - in charge drawing complete |
| 148 | M & L for welding in repairs ex 2.5 cm but not exc 5cm complete all as specified and directed by Eng-in-charge. |
| 149 | S & F 100mm size concealed push lock for aluminium sliding window complete all as specified and directed. |
| 150 | Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge. |
| 151 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 3 mm thick bakelite sheet top cover (ISI Marked)fitted with Chromium plated brass screws & washers for painot type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). |
| 152 | All as per Item No.151 above here in before but for One three pins 5 Amps switch socket outlet point on independent board |
| 153 | All as per Item No.151 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches |
| 154 | All as per Item No.151 above here in before but for One light point controlled by two 2-way switches of 5 amps |
| 155 | Description all as per item No.151 above here in before but for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 156 | Description all as per item No.151 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 157 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 voltdrawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). Note:- Where ever it is not feasible to cable drawn through existing PVC conduit (for ceiling fan point only) due to blocked, casing caping shall be provided by contractor without any extra cost, cost for the same shall deemed to be included in the quoted unit rate. |
| 158 | All as per Item No.157 above here in before but for One three pins 5 Amps switch socket outlet point on independent board |
| 159 | All as per Item No.157 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches |
| 160 | All as per Item No.157 above here in before but for One light point controlled by two 2-way switches of 5 amps |
| 161 | All as per item No 157 above here in before but in existing conceales for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 162 | All as per item No.157above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly using color code as per IS and all as specified complete all as specified and directed. |
| 163 | Supply and fixing modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Make :-Havells or Techno commercial equivalent Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. |
| 164 | Supply and fixing modular switch 5/6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge.Make :-Havells or Techno commercial equivalent Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. |
| 165 | Supply and fixing modular Bell Push switch, 5Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Make :-Havells or Techno commercial equivalent Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. |
| 166 | Supply and fixing modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Make :-Havells or Techno commercial equivalent Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. |
| 167 | Supply and fixing modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Make :-Havells or Techno commercial equivalent Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. |
| 168 | Supply and fixing modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Make :-Havells or Techno commercial equivalent Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. |
| 169 | S & Fin repairs switch piano one way 5/6 amps240 volts complete allas specified and directed. |
| 170 | S & Fswitch piano one way 15amps240 volts complete allas specified and directed. |
| 171 | S & F Bell push AC, 50 Hz, 230 Volts, 5 amps complete all as specified. |
| 172 | S & F Bell ding dong AC, 230 Volts, Single pole complete all as specified. |
| 173 | S & F socket 5 in 1, 5 amps flush type complete all as specifeid. |
| 174 | S & F socket5 in 1, 5/16 amps flush type complete all as specifeid. |
| 175 | S & F switch piano flush type 5 amps but 2 way type complete all as specified. |
| 176 | M & L lamp holderPVC/Polycarbonate type with back plate suitable for batten fittings incl LED bulb 12W complete, Make- Anchor/SSK/CONA |
| 177 | M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete, Make-Anchor/SSK/CONA |
| 178 | Supply only fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona/SSA or equivalent . |
| 179 | M&L forsubmain wiring comprisingsingle core ,2 Runs of 10 sqmm nominal cross sectional areamultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including 20 mm dia. PVC conduits ISI Marked and conduit fittings/existing concealed conduit complete,including provision of 1 x 10 sqmm nominal cross sectional areamultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earthwirecomplete incl taking down old UNSV sub main all as specified.( Note :-(i) Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly(ii) Run of 3 Cable shall be measured as 1 RM |
| 180 | Description all as per item No.179 above here in before butof 6 sqmm complete in PVC conduits/ complete all as specified. |
| 181 | Description all as per item No.179 above here in before but4 sqmmin PVC conduit and its fittings completeall as specified and directed by Engr-In-charge. |
| 182 | M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge . |
| 183 | Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycableof size 2 core 10 sqmm nominal cross section in service connections of PVC insulated aluminium multi standard conductor served with an inner sheathing of PVC tape andoverall PVC sheathed complete all as specified and directed by Engr-In-charge.make- Havells/Kalinga |
| 184 | All as per Item No.183 above here-in-before but 2 core 6 sqmmcomplete all as specified and directed. |
| 185 | Supply and fixing MCCB TPN ( 4 pole) 63 Amps 415 Volts of braking capacity 16 KAcomplete taking down old unserviceable one and making necessary connections as existing ls with CTC solutions complete all as specified and directed.Make : Havells/Legrand/Schneider |
| 186 | All as per Ser Item No.185 above here-in-before but 100 Amps with braking capacity 16 KA. |
| 187 | All as per Ser Item No.185 above here-in-beforebut 125 Amps with braking capacity 16 KA. |
| 188 | S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCBincomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. Make : ABB/Havells/Schneider |
| 189 | All as per Item No.188above here-in-before but TPN DB 8 Way double door type complete all as specified and directed. |
| 190 | Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 8 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. Make : ABB/Havells/Schneider |
| 191 | All as per Item No.190above here-in-before but SPN 4 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. |
| 192 | S&F PVC enclouser SPN DB 2 way having facility to fix MCB DP/SPN 2 ways complete fitted with bus bars, neutral links including provision of MCB DP 6-16A andmaking good disturbed surface area complete all as specified and directed. |
| 193 | Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls and necessary cement work for make good as existing to all disturbed surfacecomplete all as specified. Make : ABB/Havells/Schneider |
| 194 | Material and labour for replacing 2mm thick galvanised steel pressed sunken box(Min 60mm deep, suitable length) grouted flush to walls and necessary cement work of cm1:4 and applying putty around 3 mm thick switch board to match with existing surface and provision of suitable hylem sheet of 3 mm thick by fixing existing serviceable switch,sockets,regulator for any type of concealed Point wiring complete all as specified and directed.Note: Replacing Old Unserviceble switch,coekt,regulator if any with new is measurale insepearte items |
| 195 | Supplied and fixed Miniature circuit breaker (MCB)single pole, 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B\" series type complete all as directed by Engr-in-charge. Make : ABB/Havells/Schneider |
| 196 | Supplied and fixed MCB, Double pole, 240 Volts, of 32-63 amps current rating of 10 KA complete all as directed by Engr-in-charge |
| 197 | M&LLED tube light fixture environmental friendly energy efficient of 18/20W LED 6500K and above (4\") including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting completeall as specified and directed by Engr-In-charge. Crompton Cat Pt No. LDSLRP20-CDL or equavalent of Make: Havells/Philips |
| 198 | S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (45 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Havells Cat Pt No. ENDURASUNDOWNSL25WLED 765 PASYBOPCIHD Crompton or equavalent of : Havells/Philips |
| 199 | Supply and fixing LED tube light fixture environmental friendly energy efficient of2 feet, 10 Watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.Crompton Cat Pt No. LDLL10-CDL or equavalent of : Havells/Philips |
| 200 | M&L for WEE Plus LED bulk head luminaire of capacity 10 Watt an ideal energy efficient solution of metal body white upgrading conventional GLS bulkhead luminaires to LED bulk head IP 66 complete all as specified and directed by Engr-InCharge.model IK-09 metal body specially designed of Philips or equvalent of Make: Crompton/Havells |
| 201 | Supply &fixing LED driver 15W to 25 W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed. |
| 202 | Supply &fixing LED driver 30 W to 40 W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed. |
| 203 | Supply &fixing LED Strip 15 W to 40 W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed. |
| 204 | M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item). |
| 205 | Supply and fix LT Main control board of CRCA sheet metal board made out of 2.0mm thick and painting with 2 coats with synthetic enemel paint over a coat of red oxide primer including copper bus bar and fixed on/inside wall for fixing arrangement of existing electronic meter incl internal connection with suitable size of copper conductor wire, and accessories, locking arrangement with opening handle (size not less than of box 100cmx80cmx25cm and adequate depth for the following equipments,internal wiring and termination of external cables, lugs and glands and conduit as required) including Taking down existing Old Unserviceable main control board comprising of following :- (a) Incoming :- MCCB 100 Amps, 4 Pole,415 Volts, 16 KA-01 No(b) Copper Bus bar 200 Amps for phase and neutral and earth bar(c) Out going MCB SPN 40 Amps - 4 Nos(d) Out going MCB SPN 10 Amps - 1 No |
| 206 | S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection Of bldg street lights/fan/garden lights complete all as specified and directed |
| 207 | Supply and fixing LED light fitting 1 x 16 Watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone-1 &2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver holders connector complete withh all accessories prewired and including connectiong up with three core flexible copper conductor cable with suitable size.Model FIAMMA Cat No. EXTN1LT8 of Crompton or equvalent of Make:Havells/Philips/sudhir |
| 208 | Repair and maint to flame proof light fitting and replacement LED tube rod and minor spares like rubber seal,biin holder, nut bolts and washers by duly taking down the light 1 x 16 Watt flame proof complete withh all accessories and prewired and including connectiong up with three core flexible copper conductor cable with suitable size |
| 209 | Demolishing the broken earth pit chamber and constructing new earth pit chamber brick work in cm 1:4, plastering cm 1:3 and PCC chamber cover only complete as per SSR Pt -I of 1996 including new wire mesh funnel all as directed. |
| 210 | M&L for replacing of hinge, lock, spring tenstion and sheet metal door if reqd for MCB SPN DBs 4/6/8/12 way and necessary cement work to match with the exsting surface duly cleaning and tightning the loose terminations using proper termination connectors for earth and neutral complete all as specified and directed |
| 211 | M&L for replacing of hinge, lock, spring tenstion and sheet metal door if reqd for MCB TPN DBs 4/6/8/12 way and necessary cement work to match with the exsting surface duly cleaning and tightning the loose terminations using proper termination connectors for earth and neutral complete all as specified and directed |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail