| 1 | Dismantling, clearing away and carefully stacking materials useful for reuse for any thickness of walls Brick Work etc complete., |
| 2 | Dismantling, clearing away and carefully stacking materials useful for reuse for any thickness of walls Dismantling RCC using deploying machineries etc complete., |
| 3 | Chipping of concrete and roughening the surfacefrom roof/Beam/Column etc complete as per standard specification. |
| 4 | Dismantling, clearing away and carefully stacking materials useful for reuse for any thickness of walls Pressed tiles & weathering course etc complete., |
| 5 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification . CIVIL DATA -2021-22 |
| 6 | Towards the charges for removal of Old Paver Block and Relayed of Paver block removed area etc complete., |
| 7 | Towards the charges for Welding of damaged MS Door,frame, hinges with good conditions etc complete., |
| 8 | RCC drops wall of 50mm thick with cm 1:3 mix, including cost of reinforcement in position at necessary chicken mesh, Shuttering, Laying , Finishing etc., Complete as per std., Specifications. |
| 9 | Towards the charges for Plastic anti corrossion paint over the Pressed tiles at the roof including cleaning of dust etc complete., |
| 10 | Hire charges for deploying earth moving machinery (JCB/Poclain) for earthwork including diesel, oil and labour charges etc., complete. |
| 11 | Towards the Charges for cleaning of corrossion ,paint andand apply enamel paint over the Flag pole through height including all labour charges etc., complete. |
| 12 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 13 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. |
| 14 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 15 | Fabricating supplying and fixing of pre painted galvanized iron sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 16 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m |
| 17 | Supply and fixing of 1400mm sweep (56\") AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod including fan clamp with side plates and cross arm of size 450mm etc complete., (SD 108) |
| 18 | Supply and fixing of Condensor to damaged fan point etc complete., |
| 19 | Supply and fixing of PLUG AND SOCKETS IN SHEET STEEL ENCLOSUREWITHOUT MCBs 20A Double Pole etc complete., |
| 20 | Supply delivery and fixing of 1.5 sqmm PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER etc complete., |
| 21 | Dadooing walls withGlazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 22 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 23 | Supply delivery and fixing of AC Exhaust Fan 375 mm (15”) sweep (Light duty)etc complete., |
| 24 | Supply delivery and fixing of following G.I.Pipe, PVC Pipe, and UPVC/CPVCPipes & specials including cost and conveyance etc., complete as per standard specifications. |
| 25 | 40mm f PVC Pipe 6KSC |
| 26 | 25mm f PVC Pipe 10KSC |
| 27 | 32mm GI Pipe |
| 28 | 40mm dia PVC Bend |
| 29 | 40mm dia PVC Tee |
| 30 | 32mm GI Bend |
| 31 | 40mm GI Coupling |
| 32 | 40mm GI Tee |
| 33 | 40mm GI Hex Nipple |
| 34 | 40mm GM Gate Valve |
| 35 | 40mm GI Union |
| 36 | GST 18% |