Tender For Repair Maintenance Of Central Type Ac Plants At Mo Goa Lach Rajhans Inhs Jeevanti Nih And Package Type Ac Plant At Comcen Under Ge Gomantak, vasco-Goa

Military Engineer Services-MES has published Tender For Repair Maintenance Of Central Type Ac Plants At Mo Goa Lach Rajhans Inhs Jeevanti Nih And Package Type Ac Plant At Comcen Under Ge Gomantak. Submission Date for this Tender is 24-07-2023. HVAC Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

38358215
Corrigendum : Tender For Repair Maintenance Of Central Type Ac Plants At Mo Goa Lach Rajhans Inhs Jeevanti Nih And Package Type Ac Plant At Comcen Under Ge Gomantak
Open Tender
Indian
Goa
vasco
24-07-2023

Tender Details

Repair Maintenance Of Central Type Ac Plants At Mo Goa Lach Rajhans Inhs Jeevanti Nih And Package Type Ac Plant At Comcen Under Ge Gomantak

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 49400.0 /-
Tender Value
INR 24.70 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR/MAINTENANCE OF CENTRAL TYPE AC PLANTS AT MO GOA, LACH RAJHANS, INHS JEEVANTI, NIH AND PACKAGE TYPE AC PLANT AT COMCEN UNDER GE GOMANTAK.
Sl. No. Item Description
1M&L for cleaning of shell and tube water cooled condensers of the A/C plants of following capacities after dismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt and water scaling and refixing the water lines and headers including provision of new gaskets, in every 02 months etc complete all as specified and directed.
2(a) 2 x 5 TR capacity COMCEN
3(b) 3 x 9 TR capacity NIH
4(c) 2 x 12 TR capacity KV Store MO Goa
5(d) 3 x 15 TR capacity Mig Store MO Goa
6(e) 3 x 24 TR capacity Kiran Store MO Goa
7(f)3 x 30 TR capacity Rajhans
8(g) 2 x 48 TR capacity Jeevanti OT
9(h) 3 X 25 TR Capacity Jeevanti ICU
10(i)3X 11 TR CapacityNew mig store Package AC plant
11(j)3 X 8.75 TR Capacity SEFC store package AC plant
12Supply and fix in repairs ball / roller bearing for pumps and motors of following capacity including taking down old bearing and re installation at site including testing on completion complete all as specified and directed.
13(a) Upto 15 HP capacity
14(b) 20 HP to 30 HP capacity
15(c) 40 HP to 60 HP capacity
16Supply and charging Refrigerant compressor oil Servo manufacturedby Indian Oil Corporation or Equivalent approved make including flushing/cleaning of oil chamber etc complete all as specified and directed.
17Nitrogen testing for the any capacity of compressors including condensing unit and gas piping completeas per the manufacturer instructions and entire satisfaction complete all as specified and directed. Note :-(i)Nitrogen pressure should be held with out any drop in pressure inside the unit continue for 24 hours.
18Supply and filling Nitrogen Gas Cylinder of 7.5 cubic meter complete all as specified and directed. .
19Supply and filling Refrigerant gas R-407 of 61 Kg complete all as specified and directed.
20Supply and filling Refrigerant gas R-22 of 61 Kg complete all as specified and directed.
21M&L for servicing Monoblock pumps including dismantling and opening the pump, repair/replacement of defective impeller, replace the worn out bearing impeller,stuffing box, back plates, gland packing mechanical seal and rusted nut, bolts etcassembling property, greasing all movable parts, fixing in position, testing and commissioning all as directed for the following HP pumps complete all as specified and directed.
22(a) 3 HP to 5 HP Pump
23(b) 7.5 HP to 10 HP Pump
24Supply and fixing in repair power assembly expansion valve for following AC Plants as per existing make and model complete all as specified and directed by Engr-in-Charge.
25(a) 12 TR to 30 TR AC Plant
26(b) 48 TR to 60 TR AC Plant
27Supply and fixing in repair Motor & Voltage Protection Device (MVPD & VPD) for AC plant as per existing make and model complete all as specified and directed.
28S & F microprocessor/PCB for compressor of capacity from 18 TR to 60 TR as per existing make/model complete all as specified and directed.
29Supply and fix of V-belt for AHU as per existing size of following AC Plants complete all as specified and directed.
30(a) 05 TR to 12 TR AC Plant
31(b) 18 TR to 30 TR AC Plant
32(c) 48 TR to 60 TR AC Plant
33M&L for Realignment of compressor and motor of any capacity on existing foundation complete all as specified and directed.
34Supply and fixing of CI butterfly valves with matching flanges, gaskets, hardware duly insulated with preformed pipe section fabricated to shape and bonded with adhesive. removable cover is required valves in 26 SWG aluminium sheet, cover should be divided in to portions quick release toggles shall be used for assembly of coverscomplete all as specified and directed.
35(a)50 mm bore.
36(b)65 mm bore.
37Supply and fix High pressure control switch as per existing make and type including taking down old switch complete all as specified and directed.
38Supply and fix oil pressure control switch as per existing make and type including taking down old switch complete all as specified and directed.
39Supply and fix low pressure control switch as per existing make and type including taking down old switch complete all as specified and directed.
40Supply and fixing Water pressure guage of condensing water line complete all as specified and directed.
41S & F Thermostatic expansion valve assembly complete of capacity from 15 TR upto 30 TR complete all as specified and directed.
42S & F Thermostatic expansion valve complete of capacity from 50 TR complete all as specified and directed.
43Supply and fix LP/HP cut out as per existing make and model including taking down old cutout for AC Plant upto 30 TR capacity complete all as specified and directed.
44All as per item No 21 but for AC Plant 48 TR to 60 TR capacity complete all as specified and directed.
45Supply and fixing power contractor assembly for upto 10 HP motor/pump complete as per existing type and make including taking down old contactor complete all as specified and directed.
46All as per item No 23 but for 25 HP motor complete all as specified and directed.
47All as per item No 23 but for 40 to 60 HP motor complete all as specified and directed.
48Supply andfixing Thermal Overload relay range 9 - 12.5 amps as per existing make suitable for upto 10 HP motor/pump complete all as specified and directed.
49All as per item No 26 but 30-36 amps complete all as specified and directed.
50All as per item No 26 but 70-80 amps complete all as specified and directed.
51Supply and fixing electronic timer for star delta function having time range 1 - 20 sec, input voltage 380-440V AC or as per existing make and model including taking down of old one complete all as specified and directed.
52All as per item No 29 but 3 - 60 sec complete all as specified and directed.
53Supply and fixing indicator lamp assembly set complete LED type suitable for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed.
54Supply and fixing push button assembly complete LED type suitable for the existing system supply voltage 230V / 440 V AC including taking down push button assembly complete all as specified and directed.
55Dismantling the unserviceable electric motor any type or of any capacity and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enamelled copper winding wire of existing gauge andsize with insulating materials, varnishing andbaking etc, re-fixing the same at site and re-alignment, testing and commissioning complete all as specified and directed.
56Taking out old and fix new PVC fins of cooling tower of any capacity AC plant and replacing with new one including setting complete all as specified and directed.
57Supply and fixing in repair fabricated Hyphen filter Pre filter of 90% efficiency and filtration level of 10 microns made out of GI channel frame overall size 55 cm x 55 cm x 5 cm including nylon micro filter and wire mesh covered front and back all as per sample given including taking down old micro filter
58Preparation of old painted surfaces by removing dust, rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower, condensing pipe line condenser water pumps including all pipe line valves etc. of 5 TR to 60 TR Capacity Plant complete all as specified and directed.
59Supply and fix CT fan (with hub and fan blade) of capacity 03 HP Motor ‘F’ class IP-55 Flange mounted weather proof, 1200mm dia fan made up of cast aluminium alloy and testing on completion complete including dismantling of old one all as specified and directed
60S & F in repair chilled water sensor for AC Plants of any capacity
61S & F solenoid valve assembly complete for compressor of capacity upto 30 TR.
62S & F solenoid valve assembly complete for compressor of capacity from 48 TR upto 60 TR.
63S & F loading/unloading switch assembly for compressor of capacity upto 30 TR.
64S & F loading/unloading switch assembly for compressor of capacity from 48 TR upto 60 TR.
65S & F cooling tower nozzles 1/4"" size of existing model
66S & F block bearing for air handling unit size 207 of existing model
67Supply and fix pressure relief valve as per existing make and model.
68Supply and fix Cold room humidity sensor as per existing make and model.
69Supply and fix Cold room strainer as per existing make and model.
70Supply and fix solder tube union (with valve core & copper tube) as per existing size.
71Dismantling the compressor and taking out the shaft from the compressing unit and taking to the reputed workshop for necessary lathe/ machining work to match the bearing size, cleaning inside the compressing unit and necessary overhauling including replacement of defective parts complete as directed installation of compressor and connect with motor, alignmentand carrying out of testing to the entire satisfaction of Engr-in-charge for 18 TR to 30 TR AC plant compressor complete all as specified and directed. Note : The parts will be measured and paid seperately.
72Supply only spare for 9 TR to 15 TR capacity compressor
73(a) Main bearing for both ends
74(b) Connecting rod bearing
75(c) C R bush
76(d) Pistons
77(e)Pistons pin
78(f) Piston ring set
79(g) Piston circlips
80(h) C R Nuts & bolts
81(j)S V Reeds
82(k) D V Reeds
83(l)S VSprings
84(m)D V Spring
85(n)Suction filter dryer.
86(o)Oil pump
87(p)Linear o ring
88(q)Gasket set
89(r)Thrust washer
90(s)Aluminium Gasket set
91(t)Oil pressure regulating valve
92(u)Suction and discharge valve O ring seat
93M&L for assembly and erection of GI sheet with TDF flange rectangular/square duct made out of L shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 22 gauge complete all as specified and as directed .
94M&L for providing acoustic lining to the ducting by using FG crown 200x25mm thick rigid board density 32kg/m3 covered with RP tissue & 28G aluminium perforated sheet & using GI nuts, bolts & washer for the entire duct complete all as specified and as directed.
95M&L for thermal insulation of duct using adhesive & FG crown-150 factory laminated covered with aluminium foil of 50mm thickness complete all as specified and as directed.
96Supply and fixing in repair HEPA (High Effective Particulate Air) Filter of existing dimension with aluminium frame having flow capacity of 500 cfm and DOP efficiency of 99.99% complete all as per existing including taking down old filter.
97Repair of Microprocessor control unit ofany capacity AC Plant.
98Supply and installation of Circular Type FRP Induced Draft Counter Flow Cooling Tower, vertical with uniform water distribution and optimal heat transfer, suitable for 30 TR AC plant capacity, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, 02 HP Motor ‘F’ class IP-55 Flange mounted weather proof, 900mm dia fan made up of cast aluminium alloy and testing on completion complete including dismantling of old one all as specified and directed. Note :-The rate should be inclusive of civil works and connecting of existing pipe line to the new cooling tower.
99Supply and installation of Circular Type FRP Induced Draft Counter Flow Cooling Tower, vertical with uniform water distribution and optimal heat transfer, suitable for 50 TR AC plant capacity, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, 03 HP Motor ‘F’ class IP-55 Flange mounted weather proof, 1200mm dia fan made up of cast aluminium alloy and testing on completion complete including dismantling of old one all as specified and directed. Note :-The rate should be inclusive of civil works and connecting of existing pipe line to the new cooling tower.
100M&L for dismantling condenser unit from 25 TR AC plant, transporting to workshop and removing damaged shell and tube from the condenser unit and replacing with new one and refixing the condenser unit, testing on completion complete all as specified and directed.
101Supply and fix of V-belt of size A32 including taking down old belt all as specified and as directed.
102Supply and fix in replacement of power contactor assembly complete 63 Amps, 50 KA, 415 V all as spcified and as directed
103Supply and fix in replacement of power contactor assembly complete MNX -25 including taking down old contactor all as spcified and as directed
104Supply and fix in replacement of power contactor assembly complete MNX -12 with one NO and NC including taking down old contactor all as spcified and as directed
105Supply and fix in replacement of power contactor assembly complete MNX -32 including taking down old contactor all as spcified and as directed
106Disconnecting wiring carefully and removing defective auxillary power contactor assembly complete and replacing by new one of size 12.5 to 20 Amps type 3 NA with 1 NO+NC all as specified and as directed.
107Overload relay range upto 7.5 Amps suitable for MNX contactor all as specified and as directed
108Supply and fixing electronic timer ST 100(3 to 10 sec) 240 V or as per exisiting Make including taking down of old one all as specified and as directed
109Supply and fixing in repair of MCB TP 40 to 63 Amps 10 KA all as specified and as directed
110Supply and repair of MCCB 3 pole 415 Amps 125 Amps breraking capacity 25 KA all as specified and as directed
111Supply and fixing in repair of MCB SP 06 to 32 Amps 10 KA all as specified and as directed
112Supply and fixing in repair fabricated micro filter upto 90 micron made out of GI channel frame overall size 61cm X 61cmX5CM including nylon micron filter and wire mesh covered front and back all as specified all as per sample given including taking down old micro filter all as specified and as directed
113S & F pressure gauge for neon gases 0 to 25 kg all as specified and as directed
114S & F pressure gauge for neon gases 0 to 16 kg all as specified and as directed
115S & F microprossor for compressor of capacity 5.5 TR to 11 TR all as specified and as directed
116S & F in repairs Thermostatic Expansion Valve assembly complete for R-22 gas all as specified and as directed