Tender For Repair Maintenance Of Fire Fighting Equipment Fire Alarm System And Hanger Door And Connected Items In Ins Rajali Arakkonam, arakkonam-Tamil Nadu

Military Engineer Services-MES has published Tender For Repair Maintenance Of Fire Fighting Equipment Fire Alarm System And Hanger Door And Connected Items In Ins Rajali Arakkonam. Submission Date for this Tender is 02-08-2023. Alarm Systems Tenders in arakkonam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

38357956
Corrigendum : Tender For Repair Maintenance Of Fire Fighting Equipment Fire Alarm System And Hanger Door And Connected Items In Ins Rajali Arakkonam
Open Tender
Indian
Tamil Nadu
arakkonam
02-08-2023

Tender Details

Repair Maintenance Of Fire Fighting Equipment Fire Alarm System And Hanger Door And Connected Items In Ins Rajali Arakkonam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jul-2023 Amendment to tender documents Other 17-07-2023
2 08-Jul-2023 Amendment to BOQ BOQ 17-07-2023
3 12-Jul-2023 Date Corrigendum Date 26-07-2023
4 26-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINTENANCE OF FIRE FIGHTING EQUIPMENTFIRE ALARM SYSTEM AND HANGER DOORAND CONNECTED ITEMS IN INS RAJALI ARAKKONAM (TENDER ID No. 2023_MES_605487_1)
Sl. No. Item Description
1M&L to attend the complaints on the Fire Alramcontrol panel, Microprocessing unit of the system of any make as and when required. Note: Spares if any required shall be measured under relevent items as supply only
2Checking and identifying complaints of Fire Motor and siren Stater etc, of any make and capacity and making it 100% functional complete all as specified and as directed Note: (a )Spares required to be replaced for the functioning of the Fire Motor and sirenshall be measured and paid separately (under relevant item) as supply only. (b) Quoted rates includes labour cost for taking down old items and fixing new one.
3Taking down the 3 phase, 415V, 50Hz, 7.5 HP capacity monoblock pump motor set Make: Kirloskar from terrace of highraised building (upto- G+5), lowering to ground floor, transporting to private workshop, dismantling and opening, removing burntoutwinding wire carefully cleaning the slots and rewinding of motor with super enamelled copper winding of existing gauge, insulating, varnishing, backing including servicing the pump by greasing and lubricating, reassembling, re-fixing in position commissioning and testing complete all as specified and as directed .
4Taking down the monoblock pump setwith 7.5 HP capacity motor Make : Kirloskar from terrace of highraised building (upto- G+5), lowering to ground floor, transporting to private workshop, dismantling and opening the pump , metalling the worn out shaft and replacement of NDE/ DE bearings, gland flange, gunmetal bush and lubricating the bearings and replacing the gland rope of existing size reassembling, refixing in position commissioning and testing complete all as specified and as directed .
5Taking down siren motor 3 phase 50 Hz, Make: KHIVIRAJ from terrace of buildings(upto- G+5), lowering to ground floor, transporting to private work shop, dismantling, opening, varnishing the winding wire carefully cleaning the slots backing including replacement of wornout bearings, lubricating, reassembling, refixing in position commissioning and testing complete all as specified and as directed.
6Siren 2 miles range at Akash Ganga 6 storied building.
7Siren 5 miles range.
8Taking down siren motor 3 phase 50 Hzfrom terrace of the buildings(upto- G+5), lowering to ground floor, transporting to private work shop, dismantling, opening, removing burnt out winding wire carefully cleaning the slots and rewinding of siren motor with enamelled copper winding of existing gauge, insulating, varnishing, backing including replacement of wornout bearings, lubricating, reassembling, refixing in position commissioning and testing complete all as specified and as directed.
9Siren 2 miles range at Akash Ganga 6 storied building.
10Siren 5 miles range.
11Taking down existing pump set from rusted/ corrodedfoundation by disconnecting electrically/ mechanically and kept at site and removing the corroded/ damaged mild steel foundation frame and replace with new MS frame as per existing gauge and size for 7.5 HP capacity motor including replacement of bolts, nuts with washers and applying two coats of synethic enamel paint over a coat of red oxide primer as per exisitng tint/shades complete all as specified and as directed.
12Taking down existingsiren from corroded / broken MS foundation by disconnecting electrically/ mechanically and kept at site and removing the corroded/ damaged mild steel foundationand replace with new MS frame as per existing gauge and size for siren motor including replacement of bolts, nuts with washers and applying two coats of synethic enamel paint over a coat of red oxide primer of exisitng colour shades complete all as specified and as directed .
13Taking down the existing unserviceable rusted MS pipe from floor/wall/ in trenches and ground floor to terrace (buildings upto- G+5) by dismantlingfrom wall/ terrace cutting by gas or arc welding for the following sizes complete all as specified and as directed .
14100mm dia bore pipe
15150mm dia bore pipe
16200mm dia bore pipe
1780mm dia bore pipe
18Supply and fix mild steel pipe heavy grade including all fittings from terrace /wall fixed with mild steel clamps, brackets of required size including necessary bends, reducers, flange and welding the pipe connection all in position including painting with two coat of synthetic enamel paint of approved tint over a coat of red oxide making good the disturbed portion for the following sizes complete all as specified and as directed. Note: PCC shall be measured and paid seperatly under relevent items.
19100mm dia bore pipe
20150mm dia bore pipe
21200mm dia bore pipe
2280mm dia bore pipe
23Taking down the existing unserviceable CI sluice valve, supply and fix new sluice valve with iron wheel stainless steel spindle and wedge nut with flanged of size 100mm dia, PN1.6 long body conforming to IS 14846 including replacing bolt, nuts and washers with gaskets jointing etc., complete all as specified and as directed .
24All as per item no 11 here in before but sluice valve with iron wheel stainless steel spindle and wedge nut with flanged of size 150mm dia complete all as specified and as directed .
25Taking down the existing damaged/ rusted siren motor cover, supply and fix new siren motor cover made with MS sheet 3mm thick with handle arrangement including MS flat and fixing with bolt,nuts all as per existing type/size for supporting to siren motor cover and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide primer of exisitng tint/shades complete all as specified and as directed .
26Taking down the existing unserviceable CI Non return valve supply and fix new CI Non return valves with bypass arrangement flange type PN 1.6 complete with rubber gasket, bolt and nuts, etc., complete all as specified and as directed .
2780mm dia
28150mm dia
2950mm dia
30100mm dia
31Taking down existing damaged RRL hose 63mm dia, supply and fix hose for fire fighting 63mm dia 30m length conforming to IS636 complete with SS male and female coupling complete all as per existing specification and as directed.
32All as per item no 15 here in before but 15m length complete all as specified and as directed .
33Taking down existing damaged hose box and supply and fixing Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside complete all as per existing specification and as directed.
34Taking down existing damaged glasses from hose box and supply and fixing 4 mm thick glasses with rubber gasket suitable for door frame complete all as per existing specification and as directed.
35Material and labour for painting with two coat of synthetic enamel paint of approved tint as directed on iron/ steel surfaces of any description over 10cm in width or girth including holder bats, distance pieces, etc., including cleaning the surface for free from dust and deposits complete all as specified and as directed .
36Material and labour for painting with two coat of synthetic enamel paint of approved tint as directed onpipes any description (fire hydrants, pipe lines) n.exc 60cm girth including holder bats, distance pieces, etc., including cleaning the surface of pipes and fire fighting pump house headders, air releasing vessels and suction and delivery pipes (length measured over bends, branches etc.,) complete all as specified and as directed .
37Taking down the existing damaged/ rusted centrifugal pump set cover, supply and fix new centrifugal pump set cover made with MS sheet 3mm thick with handle arrangement including MS flat all as per existing type/size for supporting to centrifugal motor cover and applying two coats of synethic enamel paint of approved tint over a coat of red oxide primer of exisitng tint/ shades complete all as specified and as directed
38Taking down the existing damaged Fire brigade inlet connection and supply and fix new Fire brigade inlet connection 2way SS complete all as specified and as directed
39Taking down the existing fire hydrant valve and supply and fix new stainless steel fire hydrant valve of size 63mm dia including replacing bolts, nuts and washers with gaskets jointing etc., and making necessary welding for anti thievery measures/ arrangements complete all as specified and as directed
40Taking down the existing unserviceable damaged gun metal female coupling flange 63mm dia and supply and fix new stainless steelfemale coupling of 63mm dia with flange 63mm dia including replacing bolt, nuts and washers with gaskets jointing etc., complete all as specified and as directed
41Material and Labour for opening the top of the Sluice valve of the following sizes carefully and taking out the gate incl spindle & checknut scrapping/Cleaning refacing, regrinding of gate of sluice valve and spindle, refixing the spindle, gate check nut and top of Sluice valve including repacking stuffing box of sluice valve spindle by replacement of gland packing rope of suitable size and reassembling including replacement of rubber gasket, Bolts, Nuts etc and making the sluice valve serviceable complete all as specified and directed
42100mm dia
43150mm dia
44Taking out the existing DOL starter from panel upto 7.5 HP capacity motor, cleaning the electronic parts from inside, replacing the unserviceable OLR, contactor, NVC etc., complete all as specified and as directed
45Taking down the existing unserviceable damaged Pressure switch from existing position and supply and fix new Pressure switch as per existing type /size / capacityincluding replacing unservicaable connecting system complete all as specified and as directed
46Dismantling all the modules of fire alarm control panel and carry out checking of all parts such as main control panel, intelligent, repeater control panel, intelligent addressable smoke detectors, addressable input/ out modules, panel moudles, indicating circuits, control circuits, manual call point, hooters, and notification appliance circuits local and remote operated terminals, etc., including testing, reassembling, trial programming with a sample of devices, replacing fault modules where necessary and retesting all the functionals such as power test, CPU fault, GND fault, disable, reset, alarm silence, panel silence, drill, alarm, SUP, trouble monitor and command menues, fire, fault, etc., and confirm serviceability of the FACP and labour charges for loop testing (address and setting programming and testing all devices in Intra panel loop) to indentify the defects in devices, loop errors and final testing and commissioning complete forfire alarm systems located at following locations all as specified and as directed
47New Magazine
48Processing unit Building
49MK-54 Building including service block
50P8I Maint hangar - 1 No.Make: HONEYWELL (upto 28 meter height)
51BSF Hanger (LRMR) & storage Accn - 1 No each .Make: APPOLO
52Four hangar - 4 Nos. Make: APPOLO(upto 28 meter height)
53Magazine - 01 No( Magazine "A" to Magazine "C") Note for item No. 26.01 to 26.07: (i) Spares required for replacement shall be measured and paid separately under relevant items as supply only and labour cost for fixing is deemed to be included in the rate quoted . (ii) Rates deemed to be inclusive of technician visiting charges and complete tools and plants like ladder,etc., all as directed by Engr-in-charge. (iii) Each Qtr complete fire alarm system to be checked and tested as per norms for system healthy, cleaning of sensors,call points etc to be carriedout and defective component if any found to be repaired/replaced (iv) If any break down occurs in fire alarm system the contractor has to repair/ rectify the fault within 24 Hrs after receiving of complaints vide any mode and incase if the contractor failed to attend the fault, penalty will be charged @ Rs 1000.00 per day/ per installation after 24 Hrs till date of defect rectification.(v) Maintaining of service register is essential for every servicingwith the signature of concern in charge (vi) Item will be measured and paid only for the Qtr in which servicing carried out and the system is in serviceable condition. (vii) Boom lift required for repair works be arranged by the contractor and will be measured and paid separately under relevant item of schedule
54Supply only the following items complete all as specified and as directed Note: Rates for labour/technician visiting charges and complete tools and plants like ladder etc., deemed to be included in item no-28 here-in-before and charges for boom lift will be paid separatly as per item No. 55
55Detectors complying with and type certified to EN - 45 addressable type smoke detector photoelectric / optical with base with self built intelligence as per IS: 11360. Make: Honeywell/Appolo
56Addressable type flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module). Make: Honeywell/Appolo
57Addressable type multi sensor with heat and smoke combination. Make: Honeywell/Appolo
58Hooter/ addressable sounder. Make: Honeywell/Appolo
59Addressable manual call point resettable type.Make: Honeywell/ Appolo
60Addressable Zone module. Make: Morley/ Honeywell/ Appolo
61Battery 7 AH.Make: Exide/TATA
62Short circuit isolator.Make: Honeywell/Appolo
63Fire alarm control panel complying with BS EN 54 upto five loop panel as required of capacity from 99 detectors & 99 modules upto 200 detector and modules all as specified and as directed.Make: Appolo/Siemens/ Honeywell
64Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep getting out in soft /loose soil for taking up/ laying pipe/cable complete all as specified and as directed .
65Returning, filling in trenches in soilin layers n.exc 25cm thick after laying of pipe / cableincluding spreading, levelling and well ramming including watering as required complete all as specified and as directed .
66Removing surplus excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above from the starting point complete all as specified and as directed .
67Supply and lay XLPEinsulated armoured heavy duty electric cables with aluminium conductor 1100 volts grade, cross sectional area 6 sqmm 4 core complete all as specified and as directed
68Material and labour for PCC in roof kerb or mud stops, rounded or chamfored on edges type C-1, 1:3:6 (Using 20mm graded stone aggregate) complete all as specified and as directed
69Supply and fixing pre fabricated readily available Pipe Support for all types of pipes including hangars / fastners / elbows/supports / tees and welding etc including taking down old corroded support all as specified and as directed
70Supply and lay PVC flexible armoured cable 2 core 1.5 sqmm complete all as specified and as directed .
71Taking down the existing unserviceable pressure gauge and supply & fixing new pressure gauge 4"dial 0-21 kgs rating in position with GI nipple in terrace of multistoried building and testing complete all as specified and as directed
72Material and labour for repairs to siren control panel including cleaning the electronic parts exists inside panel and replacing the unserviceable items like OLR,contactor,NVC,NONC ,connecting links,voubler and any other connected items etc. complete all as specified and directed.
73Taking down the existing unserviceable air release valve 25mm dia and fixing new PVC air release valve in position with GI nipple in terrace of multi-storied building and testing complete all as specified and as directed
74Taking out the existing star delta starter from panel, cleaning the electronic parts from inside and replacing the unserviceable items line the OLR, contactor, NVC, connecting link wires etc., of the following capacity motor complete all as specified and as directed
7510 HP capacity
7615 to 25 HP capacity
7730 to 75 HP capacity
78Material and labour for taking down opening motor of centrifugal main pumpset & jockey pumpsets for repair and taking out damaged/burnt out winding from three phase motor, cleaning the slots with CTC and rewinding the same with new super enamelled copper winding wire of existing gauge and turns, varnishing , bakingreassembling and fixing back into position for making motor fully functional and testing for satisfactory running complete for the following capacities complete all as specified and as directed
7910 to 15HP
8020 to 35 HP
8140 to 50 HP
82Material and labour for taking down and dismantling centrifugal main pumpset & jockey pumpsets and carrying out repairs, replacement of worn out parts such as bearings, gland metal bushes etc., and reconditioning of spare parts such as shaft, impellers, housing body etc., by metalling and machining to their original shape and size and assembling back into position by using new suitable gland dory, gland plate, gland/rubber packing including studs/gland bolts and nuts, coupling bushes etc., oiling and greasing for making pumpset fully functional and testing for satisfactory running complete for the following capacities complete all as specified and as directed:-
8310 to 15HP
8420 to 35 HP
8540 to 50 HP
86Material and Labour for taking down and dismantling/ opening the 5 HP capacity door motor and taking out damaged/burnt out winding the three phase motor, cleaning the slots with CTC and rewinding the same with new super enamelled copper winding wire of existing gauge and turns, reassembling, oiling and greasing, and fixing back into position for making motor fully functional and testing for satisfactory running complete :
87Material and Labour for dismantling door motor , carrying out repairs,servicing andreconditioning of spare parts such asthrust bearing with plate, shaft etc., by metalling and machining to their original shape and size, assembling back into position by, applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, testing for satisfactory running complete for the following capacities :-NOTE : (i) Ratequoteddeemed to include M&L cost for repair and replacement of spares.
88S & F door motor coupling with key as per samplecomplete all as specified and as directed
89Material and Labour for Air compressor , carrying out repairs,servicing andreconditioning of spare parts such asthrust bearing with plate, shaft etc., by metalling and machining to their original shape and size, assembling back into position by, applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, testing for satisfactory running complete for the following capacities :-NOTE : (i) Ratequoteddeemed to include M&L cost for repair and replacement of spares.
90Material and Labour for dismantling door gear box, carrying out repairs,servicing andreconditioning of spare parts such aschain teeth wheel etc., by metalling and machining to their original shape and size, assembling back into position by, applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, testing for satisfactory running complete for the following capacities :-NOTE : (i) Ratequoteddeemed to include M&L cost for repair and replacement of spares.
91Supply and fix Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type complete all as specified and as directed
92Material and labour for sub main wiring complete with 4 runs of 4 sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 volts grade,multi stranded with copper conductor, drawn through and including suitable size of steel conduit pipe and accessories on surface/ wall / roofetc. with one run of PVC insulated,4 sqmm FRLS cable, copper conductor for earth continuity conductor including taking down the old sub main wiringall as specified and as directed
93Material and labour for preparation of old painted external surfaces of foam tank 4500 ltrs capacity and applying a two coats of synthetic enamel paint of approved tintover a coat of red oxide paint complete all as specified and as directed .
94Hiring boom lift suitable for minimum 30 mtr height for servicing, checking for repair / replacement of fire alarm system detectors / sensors and other allied items installed at Hangers , including necessary operator,fuel,T&P, safety equipments/tools complete required for safe operation complete all as specified and directed. Note: Each day is minimum of 8 Hrs ofworking
95Taking down the existing unserviceable foot valve PN 1.6 ball type and supply and fix new foot valve in position with suction line for the following sizes complete all as specified and as directed
96200mm dia
97150mm dia
9880mm dia
99Taking down the existing unserviceable butterfly valve 100mm dia supply and fix new valve arrangement flange type PN 1.6 complete with rubber gasket, bolt and nuts complete all as specified and as directed .
100Taking down the existing unserviceable butterfly valve 80 mm dia supply and fix new valve arrangement flange type PN 1.6 complete with rubber gasket, bolt and nuts complete all as specified and as directed .
101S & F phase sequence relay - 800complete all as specified and as directed
102S & F wabler for siren as per sample complete all as specified and as directed