| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in widthor 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directedwithin a lead of 50 m. (a) All kinds of soil |
| 2 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 3 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: (a)All works upto plinth level |
| 4 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 5 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing complete. b) Moorum |
| 6 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1cement :4 coarse sand)in foundation and basement. |
| 7 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1cement :4 coarse sand). laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 8 | Half brick masonry in cement mortar 1:3 (1 cement : 3 coarsesand) with bricks of class designation 75 kg /cm2. b) Upto floor V level. |
| 9 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 10 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 11 | Providing and fixing vitrified matt finished (600x600) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed ofcement mortar 1:3 and jointed with cement slurry complete. |
| 12 | Providing and fixing vitrified antiskid tiles (320x320) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 13 | Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete. b)Wall Ceramic Glazed Tiles : 300 x 450 |
| 14 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqma)Jet black |
| 15 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) c) In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level |
| 16 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 17 | Proposed Changing Rooms |
| 18 | I) Foundations, Footings, Bases for columns |
| 19 | iv) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 20 | xiii) Suspended floors, roofs landings, shelves & their supports |
| 21 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member |
| 22 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 23 | Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheronmake only)in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint.b) In tees, angles, flats and channels |
| 24 | Providing & Fixing in position Double Skin roof with Zincalume/ Galvalume colour coated & bare profile sheet with subtle square fluting factory cut at all heights for roof, side & Gable cladding complete in all respect. TOP SHEET (Tile Profile) -The end rib shall be designed for anti-capillary action. The feed material should be manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 43.5% Zinc &1.5% Si) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides) with quality paint coat as per AS/NZS 2728 type 3-4. The paint shall have a total coating thickness of nominal 35 µm, comprising of nominal 20 µm exterior SMP coat on top surface and nominal 5 µm reverse backer coat on back surface over nominal 5 µm primer coat on both surfaces of approved colour shade. Total Coated Thickness (TCT) should be 0.50mm. Total Painted Thickness (TPT) should be in addition to 0.50mm. The steel sheet shall be fastened with nominal 40 µm zinc coated or nominal 25 µm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load. The fastener size shall be calculated as per the design or manufacturers recommendations. |
| 25 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 26 | PVC false ceiling grid type: Providing and fixing PVC False Ceiling consisting of 600mm x 600mm, 5mm(±0.25) thick Plain PVC sheet of 600 kg/Cbm Density Manufactured by an ISO-9000 certified Company, used as panel insert in a frame work made using anodized aluminum T- section of sizes 1” x1” (25x25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2’x2’(600x600mm). The aluminum frame work is supported from the ceiling with the help of \"J\" hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level etc. The aluminum framework is supported on side wall with the use of aluminum L-section of size 1”x1” (25x25mm) angles etc. Complete as per direction of Engineer-In-charge, manufacturer’s specification & drawing. |
| 27 | Providing& fixing flush door shutters decoration type core of block board construction with frame of first class hard wood and well matched first class Indian teak ply veneeringwith vertical grains and cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodized aluminium butt hinges with necessary screws: |
| 28 | Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon. b) Second class Indian teak wood |
| 29 | Melamine polishing on wood work (one or more coat) b) Matt |
| 30 | Providing FRP door shutters 35mm thick with frame size in clear opening of 0.75x2.10m hinges and screws complete., |
| 31 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with three sliding shutters using 18 mm series shutters section. b) Plain glass |
| 32 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows. c) Figured glass |
| 33 | Extra for powder coating with pure polyester powder of shade of required colour on the aluminium section |
| 34 | Precast plain Cement Tacktiles 32mm thk of required shade in floors, treads of steps and landing laid on 25mm bed of cement mortar 1:4(1cement:4coarse sand) jointed with neat cement slurry with pigment to match the shade of tiles including rubbing and polishing complete. |
| 35 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws.(a)Plain grill |
| 36 | Providinganti – termitetreatment tobuildingsconforming to I.S.S. 6113 part II 1971 (revised) including adoptingprecautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicatingany infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. a) Pre-construction |
| 37 | Neat Cement punning |
| 38 | Providing and fixing bright finished brass door latch with necessary screws etc complete. (a) 300x 16 x 5 mm |
| 39 | Providing & fixing bright finished brass 100 mm. mortice latch & lock & a pair of levers, handles with necessary screws etc. complete (Indian make of approved quality). |
| 40 | Providing and fixing brass hydraulic door closer of make Everest universal 68 or equivalent with necessary screws and fittings complete. |
| 41 | Providing and fixing chromium plated brass sliding door bolt with bolts, nuts and screws etc. complete. (b) 250 x 16 mm |
| 42 | Providing& fixing chromium plated brass tower bolts (barrel type) with necessary screws complete. (b) 200 x 10 mm |
| 43 | Providing and fixing chromium plated brass handle with necessary screws etc. complete. (a) 125 mm |
| 44 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 45 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. |
| 46 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 47 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 48 | Wall painting(two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 49 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 50 | Providing cuddapah stone benches (50cm wide and 45cm height) of 25 mm thick cuddapah slabs machine cut and polished on either side in partitions and also for the top slab, along with jet black mirror polish granite flooring on top 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete Granitic slab (jet blck with mirror polish) including making necessary grooves in the wall and fixing with cement mortar etc complete. |
| 51 | Providing and fixing white vitereous china pedestal type (Europen type) water closet with seat as lid, whth C.I. brass hinges and rubber fitings 15 lts white vitreous china low level flushing cistern with fittings as brackets 40 mm white precelain 3enameled flush bad, 25 mm overflow pipe with specials and mosquito proof coupling of approved municipal design complete, including cutting and making good the walls and floors where required. (a) W.C. pan with white plastic seat and lid |
| 52 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. ( c) Flat back wash basin size 550 x 400mm with a pair ofsingle 15 mm C.P. brass pillar taps. |
| 53 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers. |
| 54 | Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws (b) 600 x 20 mm size |
| 55 | Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw |
| 56 | Providing and fixing brass bib cock (heavy) of approved quality :( c) 25 mm nominal bore . |
| 57 | Providing and fixing brass stop cock (heavy) of approved quality : ( c) 25 mm nominal bore . |
| 58 | Providing and fixing brass full way valve(heavy) duty with wheelof approved quality : |
| 59 | c) 25 mm nominal bore . |
| 60 | f) 50 mm nominal bore . |
| 61 | Providing and fixing non-return valve of approved quality : ( c) 50mm nominal bore |
| 62 | Providing and fixingP.V.C. connection pipe with brass unions 15 mm nominal bore: © 45 cm (18”) length . |
| 63 | Providing and fixing C.P. brass shower rose with 15 or 20 mm. Inlet: (a) 100 mm diameter. |
| 64 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming toI S 12701; 1996. ( c) 1000 lit. capacity |
| 65 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. (d) Inside size 60 x 60cmand 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 66 | Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design. |
| 67 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes ofapproved including lubricant etc. complete (single/double) socketed: |
| 68 | a) 110 mm dia |
| 69 | b) 75 mm dia |
| 70 | Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door : |
| 71 | a) 110 mm dia |
| 72 | b) 75 mm dia |
| 73 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. |
| 74 | b)20 mm dia nominal outer dia pipes. |
| 75 | d) 32 mm dia nominal outer dia pipes. |
| 76 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. I. SCH-40(blue)/(white) (e) 50mm outer dia. |
| 77 | Providing and fixing NICKEL chrome plated copper alloy Fancy Pillar Cock with extended lever handle and wall flange Confirming to IS 8931; 1993 15mm nominal bore |
| 78 | Providing and fixing NICKEL chrome plated copper alloy Fancy Two Way Bib Cock with single knob and wall flange conforming to IS 8931:1993 15mm nominal bore. |
| 79 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 80 | Providing and fixing white vitreous china flat back Large lipped front urinal basin of590x375x390mm size with Urinal Valve Auto closing system with built in control cock & wall flange with fittings, spreader, R.S. or C.I. brackets, standard size C.P. Brassl flush pipe and spreaders with C. P. brass unions & C. P. Brass clamps with waste fitting as per IS 2556, PVC trap with outlet grating and other couplings in CP Brass complete, including painting, fittings, cutting and making good the walls and floors where required. - Range of one urinal basin |
| 81 | Providing 20mm thick granite slab to urinal partitions with cement complete |
| 82 | Providing and fixing decorative fiber eave board 12mm thick of height 8 inch with screws etc. with line and level complete as per the direction of Engineer-in-charge. |
| 83 | Part -B (Electrical) |
| 84 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) with modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.\"(a) Group A-- with Cat A Modular Accessories |
| 85 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium)and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 86 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. |
| 87 | (a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm casing ) |
| 88 | (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm casing ) |
| 89 | (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm casing ) |
| 90 | Supplying and fixing following modularswitch/ socket on the existing modular plate and switchboxincluding connections but excluding modular plate etc. as required |
| 91 | (a) 5/6 A switch Cat A |
| 92 | (c) 15/16 A switch Cat A |
| 93 | (d) 3 pin 5/6 A socket outlet Cat A |
| 94 | (e) 6 pin 15/16 A socket outlet Cat A |
| 95 | Supplying and fixing following size moduleas GI box alonwithmodularbase and cover plate for modulator switchesin recess etc. as required |
| 96 | (a) 1 or 2 Module ( 75 mm x 75 mm)Cat B |
| 97 | (b) 4 Module ( 125 mm x 7 mm) Cat B |
| 98 | (c) 6 Module (200mm x 75 mm)Cat B |
| 99 | Supplying and fixing modular blanking plateon the existing modularplate switch boxexcluding modular plate etc. as required |
| 100 | (a) Cat A |
| 101 | Supplying and fixing stepped type electronic fan regulator on the existing modularplate switch box including connections but excluding modular plate etc. as required |
| 102 | (b) Cat A |
| 103 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) |
| 104 | (h) 16 way double door Cat A |
| 105 | Supplying and fixing 6 A to 32 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 106 | (a) SP, Cat A |
| 107 | Supplying and fixing 63 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 108 | (d) TP, Cat A |
| 109 | (e) TPN, Cat A |
| 110 | Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete. |
| 111 | Supplying and erecting corridor/Passage light fitting (2 feet) including 18W LED lamp, comprises of extruded channel in plastic silver grey colour & with same plastic end cap on provided PVC block / wooden board. |
| 112 | Supply and erecting of 15 inch (375 mm sweep) exhaust fan with double ball bearings, 1400 rpm,heavy duty,metal body complete with all accessories |
| 113 | (a) Cat A |
| 114 | Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. |
| 115 | (a) Cat A |
| 116 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC coverhaving locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation ofpit of sizenot less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c)Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately). |
| 117 | (a) In soily strata |
| 118 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 119 | Supplying and laying 8 SWG copper wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required |
| 120 | Supplying and laying 25 mmx 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required |
| 121 | Supply of3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. |
| 122 | 3 1/2 Core 25 sq.mm |
| 123 | Supply of4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. |
| 124 | 4 Core 6 sq.mm |
| 125 | Supply of3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI markconforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. |
| 126 | 3 Core 2.5 sq.mm |
| 127 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. |
| 128 | (a) In soily strata |
| 129 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm to 400 Sq.mm on surface,etc.complete as required |
| 130 | Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FGODF/ FLS-2 |
| 131 | S.I.T.C. of cubicle outdoor panel, with canopysuitable to work on 440 v, 3 phase 4 wires and 50 Hz system. The panel should be free standing, dust and vermin proof, front compartmentalized Double Door, fabricated in 16 gauge CRCA sheet. The panel shall be powder coated with RAL 7032 colour after surface treatment with seven tank process. The cable entries shall be from bottom. Bus bar copper of size 25x5 mm for phases and neutral with colour coded heat shrinking insulating sleeves, interconnecting wiring etc. complete.The panel should be mounted suitably as required by engineer in charge along with termination and neat dressing of all cable with lugs and glands with transferring the load as per required size of cable , including Cleaning and clearing of the total area where in work is in progress. The panel will incorporate the following:as directed by engineer Incharge |
| 132 | MAIN INCOMER: |
| 133 | i) 60 to 100 AMPS TP MCCB Microprocessor based of make L&T – 1.00 no. |
| 134 | ii) Phase indicating lamp,240VAC, LED type- 6.00 Nos. |
| 135 | iii) Voltmeter 0-500 Volt……1 Nos |
| 136 | OUTGOING FEEDERS: |
| 137 | i) 100 Amps 4 Pole Manual Changeover…..1Nos |
| 138 | ii) TP MCCB 32 AMPS……..3 NOS |
| 139 | iii) S.P.MCB 6-32Amps of make Legrand/Hager/L&T - 4 Nos. |
| 140 | iii) Timer and contatorfor Auto operation of Lights………..1 set |
| 141 | Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete |
| 142 | Supplying split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity 3 star suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall type,with Refrigerants R410 A/R32 and copper condenser at position including 3 mtr copper piping, 3 mtr flexible 2.5 Sq.mm copper cable for indoor to outdoor connection, 3 mtr Drain pipe with reqired nitrile rubber / foam tube type sleeves etc complete job as required by Engineer Incharge including 10 Year warranty on compressor, 5 years warranty on PCB including Non Comprehensive Maintenance for 5 years. (MAKE-DAIKIN/BLUE STAR/MITSUBISHI/ VOLTAS) |
| 143 | Installation, Testing and commissioning of2 TR/1.5 TR Split type Room Air consitioning units as directed by engineer incharge |
| 144 | Providing Brackets for Mounting 2 TR/1.5 TR Split AC |
| 145 | Supply and installation of 5 KVA Voltage stabilisers for 2 TR Split AC units of make Everest or equivalent as directed by Engineer Incharge. |
| 146 | Supply and Laying of copper Pipping for 2 TR/1.5 TR Split type Room Air conditioner Units as directed by Engineer Incharge |
| 147 | Supply and Laying of copper Flexible cable of 3 core 2.5 Sq.mmfor 2 TR/1.5 TR Split type Room Air conditioner Units as directed by Engineer Incharge |
| 148 | Supply and Laying of Drain Pipingfor 2 TR/1.5 TR Split type Room Air conditioner Units as directed by Engineer Incharge |