| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-07-2023 | Change in Time limit | Technical Bid | 05-07-2023 |
| 2 | 24-06-2023 | SBD | Technical Bid | 05-07-2023 |
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Renovation of Existing Building at First Floor |
| 3 | Dismantling brick work tile, masonry or tile liningIn cement |
| 4 | Dismantling brick or flagged stone flooring without concrete base. |
| 5 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. |
| 6 | Doorsof area 3 sqm and below. |
| 7 | Windowsof area 3 sqm and below |
| 8 | Dismantling asbestos cement celotax or other hard board ceiling or partition walls including supporting timber |
| 9 | Cutting of floor tiles with cutter for walls 150mm wide including removal of screed and disposal of unserviceable material complete as per requirement & as desired by Engineer-in-Charge. |
| 10 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 11 | Lintels |
| 12 | Extra rate for First Floor |
| 13 | Shelves |
| 14 | Extra rate for First Floor |
| 15 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 16 | First Floor |
| 17 | Extra rate for First Floor |
| 18 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 19 | First Floor |
| 20 | Extra rate for First Floor |
| 21 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 22 | Extra rate for First Floor |
| 23 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type |
| 24 | Supplying and filling cinder on roof (Ist story) including light ramming |
| 25 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 26 | First Floor |
| 27 | Extra rate for First Floor |
| 28 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 29 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 30 | With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 31 | 12.5mm thick cement plaster 1:5. |
| 32 | Extra rate for First Floor |
| 33 | 20 mm thick cement plaster 1:5 in two coats work. |
| 34 | Extra rate for First Floor |
| 35 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 36 | Extra rate for First Floor |
| 37 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 38 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 39 | First Floor |
| 40 | Extra rate for First Floor |
| 41 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)Size 600x600 mm |
| 42 | Extra rate for First Floor |
| 43 | Providing and fixing 1st quality ceramic glazed wall tilesMatt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 44 | Extra rate for First Floor |
| 45 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
| 47 | For fixed portion & Chaukhat |
| 48 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 49 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick |
| 50 | Providing & fixing ACP Sheets of various thickness High Class ISI markedcomplete in all respect as per the directions of Engineer-in-charge.4mm thick ACP Sheet |
| 51 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop .. |
| 52 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 53 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. III (size of door 851mm to 1000mm) |
| 54 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 55 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 56 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete. |
| 57 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 58 | Providing Polyester Powder coating 60to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 59 | Renewing glass panes with putty and nails wherever necessaryFrosted glass panes weighing 8.44 Kg/sqm |
| 60 | Providing and fixing Box Type cup Board 2\"-0\" deep (Kitchen Cabinet under shelves) made of HDHMR Board 18mm thickfinished with 1mm thick sunmica on outer side inside & all around, Including telescopic slide & Multiutility Basket complete as per drawingas desired by Engineer-in-charge. |
| 61 | Providing and fixing Box Type cup Board 2\"-0\" deep (Kitchen Cabinet above shelves) made of HDHMR Board 18mm thick finished with 1mm thick sunmica on outer side inside & all around, handle lock, magnet catcher, tower bolt & Curtain rod complete as per drawingas desired by Engineer-in-charge. |
| 62 | Providing and Installation of Chimney in Kitchen make Elica Model OSB HAC touch BF90 Nero duly fixed at sitecomplete as per specifications as desired by Engineer-in-charge. |
| 63 | Providing and fixing Roller Blinds at the designated locations with fabric/ texture complete as per sample approved by Architect & desired by Engineer-in-Charge. |
| 64 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 65 | Extra rate for First Floor |
| 66 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 67 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 68 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed |
| 69 | ACOUSTIC FABRIC PANELSFOR WALL PANELINGSupply and Installation of square edge, FR grade NRC fabric (colour choice)wrapped glassfibre core panel of size 600x1200x25mm having density 100-120Kgs/m3, weight3.0kg/m2 installed by using impaling clip.The GI strut systems includes Cross channel (CC25) having thickness 0.45mm, length 3600mm, knurled web 50, depth 25mm and equal flanges 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c.Impaling clips are attached on CC25 with the points extending outward. The spikes are tipped with Stick S7 adhesive. Then the panels are positioned and pressed intoplace Complete in all respect to the entire satisfation of Engineer-in-charge./Drawing.Technical Parameters• Core - Glassfibre• Fire – Class 1 & P• Acoustics – NRCup to 0.9• Climate (OC RH) – 40, 90• Termite resistance – Yes• Light reflectance – Colour dependent• Green (RC %) – 25• Hygiene (VoC, Clean room) – Low, Class 3 |
| 70 | Credit of Material to be received from dismentling |
| 71 | Bricks from dismenling of Brick work |
| 72 | Brick/Tile bats |
| 73 | Old Doors Complete set as Aluminium |
| 74 | Old Window Complete set as Aluminium |
| 75 | PUBLIC HEALTH SERVICES |
| 76 | Drinking Water Coller & Air Conditioning |
| 77 | Providing & fixing in position Water Coolerwithout Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 78 | Water Cooler Full Steel Body 60/80ltr Capacity without StablizerDetail as per Table-3 |
| 79 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet boxof suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-Automatic Voltage Stablizer 2 KVA |
| 80 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 81 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O\" General, Hitachiwith 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipewithin building and installing charges complete in all respects |
| 82 | Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O\" General, Hitachi with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipewithin building and installing charges complete in all respects |
| 83 | Providing laying hard soft copper concealing of copper pipes of dia 12.7mmod (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. |
| 84 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 6 Kgf/cm240mm i/d |
| 85 | ELECTRICAL SERVICES |
| 86 | Providing Internal Electrical Installations: |
| 87 | POINT WIRING: |
| 88 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 89 | Wiring fan point with sheet metal fan box |
| 90 | Wiring light point |
| 91 | Wiring 3 pin 6 Amp. wall socket point |
| 92 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 93 | Wiring 3 pin 16/20 amp. power plug control point |
| 94 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 95 | Wiring Networking socket point RJ45 (one module) |
| 96 | COPPER WIRES & CONDUIT PIPE: |
| 97 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 98 | Overall size 1sq.mm (Un-sheathed) |
| 99 | Overall size 2.5sq.mm (Un-sheathed) |
| 100 | Overall size 4sq.mm (Un-sheathed) |
| 101 | Overall size 6sq.mm (Un-sheathed) |
| 102 | Overall size 10sq.mm (Un-sheathed) |
| 103 | Overall size 16sq.mm (Un-sheathed) |
| 104 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 105 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 106 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 107 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 108 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 109 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 110 | LED\"S FIXTURES & FANS: |
| 111 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 112 | Supply and erection ofLED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 113 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 114 | Supply and erection of AC Ceiling Fan 1200mm (48\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount.The product should possess a minimum air deleiveryof 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer\"s guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection &testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 115 | Providing Local Area Networking, CCTV & Display System: |
| 116 | Supply, Instalation Testing and commisssioning of Category 6 Unshielded Twisted Pair 23 AWG, 4 pair 100W cable shall be compliant with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. Tested upto 600 MHZ; Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted.Outer Diameter 6.1 mm nominal;Temperature Range -20° to +60°C complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 117 | Supply, Installation and Comissioning of CAT6 UTP 24AWG PATCH CORD:1M, Plug 30U\" Snagless complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 118 | Supply, Installation and Comissioning of Patch PanelUTP Keystone- 24 Port- loaded made of powder coated steel, Improved cable management with cable management bar, UL94V-0 rated or equivalent complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 119 | Supply, Installation and Comissioning of 24 x 10/100/1000Base-T Ports, 2 x 10GBASE-T Ports, 2 x 10G SFP+ Ports, console port for accessing the CLI of the switch., Switching capacity 128 Gbps or higher or non-blocking architecture., Switchforwarding rate be 95.24 Mpps or higher or non-blocking architecture., Switch MAC table 16K or higher., Physical stacking Up to 8 units per stack & 80 Gbps stacking bandwidth, Operating temperature -5 - 50°C (23 - 122 °F), Should have ERPS, 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol., BPDU Filter, BPDU restriction, Root restrction, Jumbo Frame up to 12K Bytes or higher., Loopback detection (LBD) to detect the loop created by a specific port.,IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave., MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier., SwitchWeighted-Cost Multi-Path Route (WCMP) and Equal-Cost Multi-Path Route (ECMP),16 no. IP interfaces, Policy-based Route and IPv6 Neighbor Discovery (ND).,VRRPv3, Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng., SwitchIEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking, Super VLAN, should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance.,port security to secures the access port based on MAC address., Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack.,DHCP snooping and DHCP server screening, DHCP server.,802.1X port based and 802.1X host based access control,Identity-driven Policy (VLAN, ACL or QoS) Assignment,RADIUS and TACACS+ authentication.,Authentication database failover., SwitchQoS (quality of service) IEEE 802.1P for traffic prioritization. It8 queues per port., Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD,Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map., Support at least2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering.time based ACL.,Support for Telnet server, TFTP Client, FTP Client and Secure FTP (SFTP) client for IPv4/IPv6 access., Should have multiple Image and configuration support to reduced down time for the switches.,SNMP v1, v2c, v3 and SNMP Traps and Remote Monitoring (RMON)., Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client.,CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP- complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 120 | Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp.Power Distribution Unit(1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards (1 No). complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 121 | Supply, erection, testing & commissioning of 1 KVA UPS with input power factor 0.99, output power factor 0.8, OVCD inbuilt, DC V 36v, efficiency above 90% complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 122 | Supply, erection, testing & commissioning of IP indoor Camera1/2.8\" SONY Starvis Back-illuminated CMOS Sensor 2 MP ,2.7-13.5mm Motor Zoom Auto Focus Lens ,AF,WDR; Super Starlight With Internal POE Main Stream: 1080P@30fps, 3M@15fps; 3MP HD Lens, With IR-CUT 2.7-13.5mm Motor Zoom Auto Focus Lens HDR, Defog, Flicker Control,2D DNR,3D DNR,Back Light control, Motion Deduction, Privacy Masking 3 Rectangular Zone, CompressionH.264/H.264+/ H.265/ H.265+/ JPEG/ AVI / MJPEG, Electronic Shutter Time Auto: PAL 1/25-1/10000Sec; NTSC 1/25-1/10000 Sec, Protocol:TCP/IP, ICMP, HTTP,HTTPS, FTP,DHCP ,DNS, DDNS, RTP, RTSP,RTCP, NTP,SMTP,ONVIF 2.4,Camera makes Sony / Mobiteh, Mountxross, Bosch, Axis/Pelco should be compatable with same make of NVR. IE Brower IE8-11, Google Chrome, Firefox, Safari, Mac Safari,Smart PhoneiPhone, iPad, Android, Android Pad, Image ConfigSaturation/ Brightness/ Contrast /Sharpness, Mirror, 3D NR , White Balance, FLK(Flicker Control)Main Stream: 1080P/720P@30fps; 3MP HD Lens, With IR-CUT/(H.264/H.265) , IR range: 30M , Recording Mode NVR/NAS/CMS/Web completecomplete in all respects as approved and desired by the Engineer-in-charge at site. |
| 123 | Supply, erection, testing & commissioning of PoE Spliliter12 v 1 Amp, IP66 For High Voltage Protection complete in all respects as approved and desired by the Engineer in-charge at site complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 124 | Supply, erection, testing & commissioning of 9CH NVR with (4096x2160, 2592x1944, 2048x1536, 1920x1080, 1280x960, 1280x720, etc), 1 VGA, 2 HDMI, Input1 Port RCA,Audio Bit Rate64kbps,Audio Compression standardG.711, Motion Detection 9 Channel, with 1HDD slot, NVR Make :Axis/Sony/Mountxross/Bosch should support IP camera Digital Zoom Backup Mode USB Device/Network,Interface2 RJ-45 10/100/1000Mbps self-adaptive Ethernet interfaces Network Functions TCP/CP, HTTP, UPnP, DNS, NTP, SMTP,PPPoE, DHCP, FTP, DDNS, RTP, RTSP, RTCP complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 125 | Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB,Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s,Cache (MB) 64,Rotational speed (RPM) IntelliPower ,Load/unload cycles4 300,000,Non-recoverable read errors per bits read <1 in 1014,Operating (2 ms, read/write) 30,Operating (2 ms, read)65, Non-operating (2 ms)250,Average power requirements (W) Read/Write 5.90,Idle 4.90,Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 126 | Supply, erection, testing & commissioning of Display Information sytem working on LAN 50\" 4K , UHD, Digital Signage,4000;1DVI-D,DP1.2,HDMIX2, HDCP2.2, Stereo mini Jack,USBX2, RS232C(in/out),RJ45, 300NITS, MagicInfo Premium software, Multi Display Control Software, WI-FI,Auto Source recovery & switching, 8Gb with StandMemorycomplete in all respects as approved and desired by the Engineer-in-charge at site. |
| 127 | Supply, erection, testing & commissioning of HDMI cable 15 mtr.complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 128 | Supply, Installation, Testing & Commissioning of Interactive flat panel display having display size as 75 inches or bigger, Backlit type- D (LED), lifetime of 50000 Hrs or higher. The resolution of the display should be 3840 x 2160(4K UHD) and contrast ratio should be 1200:1 or better, with minimum brightness as 350 cd/m2, the minimum connectivity should be Front: 1xUSB(PC) | 1xUSB(Android) | | 1xHDMI 2.0- IN Side: 1xHDMI-OUT | 1xSPDIF-OUT | 1xUSB(Touch) | 2xUSB(Android)1xDP-IN | 2xHDMI 2.0-IN Bottom: 1xLAN | 1xRS232-IN | 1xAUDIO-OUT | 1xPC AUDIO, The display should also have minimum 10 Wx 2 Built in speakers, touch response time as 6 ms or less, Frame/Structure of IFPD should have magnetic mechanism or other mechanism to hold up to two numbers of Stylus/Pen, The touch accuracy should be ± 1mm or better, Touch method should be Finger or touch pen or other solid(soft tip) object, Tempered glass should be 4T antiglare, Should have 1 OPS slot, Data from Mini PC should be shared wirelessly on multiple Phones/Tablets without any other hardware requirement. IFPD should allow user to share/mirror the content of Laptop/Desktop (Mac, Windows) and mobile device(ios,Android)wirelessly, Wireless presentation should allow user to access their Laptop/Desktop through IFPD, Should have file download feature in smart phone just by scanning the QR code, 4 GB DDR, 16/32 GB internal storage, Android version 11 complete in all respects as approved and desired by the Engineer in-charge at site. |
| 129 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 130 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |