Tender For Addn /Altn To Radiography Room At Mh Shillong And Addn / Altn Of Bldg No Dsm 48 At 39 Coy Asc (Sup) Type A And Roof Sheeting In Bldg No Dm 02 At Dm Line Shillong Cantt And Provision Of Rain Protection Shed With Hardstanding (100 Sqm) Incl, shillong-Meghalaya

Military Engineer Services-MES has published Tender For Addn /Altn To Radiography Room At Mh Shillong And Addn / Altn Of Bldg No Dsm 48 At 39 Coy Asc (Sup) Type A And Roof Sheeting In Bldg No Dm 02 At Dm Line Shillong Cantt And Provision Of Rain Protection Shed With Hardstanding (100 Sqm) Incl. Submission Date for this Tender is 14-07-2023. Building Work Tenders in shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

38324120
Corrigendum : Tender For Addn /Altn To Radiography Room At Mh Shillong And Addn / Altn Of Bldg No Dsm 48 At 39 Coy Asc (Sup) Type A And Roof Sheeting In Bldg No Dm 02 At Dm Line Shillong Cantt And Provision Of Rain Protection Shed With Hardstanding (100 Sqm) Incl
Open Tender
Indian
Meghalaya
shillong
14-07-2023

Tender Details

Additional / Alternator To Radiography Room At Mh Shillong And Addn / Altn Of Bldg No Dsm 48 At 39 Coy Asc ( Sup ) Type A And Roof Sheeting In Bldg No Dm 02 At Dm Line Shillong Cantt And Provision Of Rain Protection Shed With Hardstanding ( 100 Sqm ) Incl Appch Path

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 89000.0 /-
Tender Value
INR 44.50 Lakhs /-

BOQ Items

Name of Work: ADDN /ALTN TO RADIOGRAPHY ROOM AT MH SHILLONG AND ADDN / ALTN OF BLDG NO DSM 48 AT 39 COY ASC (SUP) TYPE A AND ROOF SHEETING IN BLDG NO DM 02 AT DM LINE SHILLONG CANTT AND PROVISION OF RAIN PROTECTION SHED WITH HARDSTANDING (100 SQM) INCL APPCH PATH HARDSTANDING NEAR LPG SHED (300 SQM) AND OPEN SHED (79 SQM) AT 39 COY ASC (SUP) TYPE A UNDER GE SHILLONG
Sl. No. Item Description
1AGE B/R SCHEDULE Excavation in foundation trenches n.exc 1.50m wide and n.exc 1.50m in depth and getting out in soft /loose soil complete all as specified and as directed.
2Excavation over areas n.exc 1.50m in depth and getting out in soft/disintegrated soil complete all as specified and as directed.
3M&L 75mm th hardcore of gauge not exc 63mm but n exc 40mm deposited sreead and levelled in layers m.exc 15 cm thick, wtered and rammed to a true surface complete all as specified and as directed.
4M&L for PCC (1:4:8) type D-2 ( using 40mm graded aggregate) as in foundation filling and mass concreteall as specified and as directed.
5M&L for RCC 1:1.5:3 (nominal mix) using (20 mm graded aggrate) as in foundation, footing,plinth beam completeall as specified and as directed.
6M&L for RCC 1:1.5:3(nominal mix) using (20 mm graded aggrate) as in columns,pillars complete all as specified and as directed.
7M&L for RCC 1:1.5:3(nominal mix) using (20 mm graded aggrate) as in beam, lintel brand over 1.50m spam complete all as specified and as directed.
8M&L formwork to sides of concrete foundation,footing, bases of column,plinth beams,foundation and other similar works with rough finish surfaces of concrete flat complete all as specified and as directed.
9M&L formwork to sides of pillars, posts,struts,pairs,columns and like complete all as specified and directed
10M&L formwork to sides and soffits of floor or roof beams, linets,cantilevers, shelves incl.supports, overhangs etc also splays between floors and beams etc complete all as specified and as directed.
11M&L mild steel TMT bars 10mm dia and over,cut to length,bent to shape required,including cranking, bending spirally for hooping for columns for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 dia or securing with clips complete all as specified and as directed.
12M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
13M&L for pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensils strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed.
14S&F pre- painted galvatume aluminium zinc coating GI based plain steel sheet as in ridge of 0.50mm thick of any colour having tensils strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed.
15Mild steel joints channel or angle or toe section, ms tube and fixed with ms flat iron cut into shape drilled and fixed with screw conforming fe 410 complete all as specified and as directed.
16S&F powder coated (min powdercoated 50 micron) anodised aluminium frame for doors,windows, ventilators plain or sliding type with one or more rebates includings joining cleat for fixing etc complete all as specified and as directed.
17S&F powder coated (min powdercoated min 50 micron) anodised ,windows, ventilators shutters side hung/sliding type without sash, aluminium senction weighing 0.55kg/m including necessary joining cleats,glading clips,rubber neoprene packing,anodised aluminium snap beading screws, anoised aluminium fitting such as peg stays 150mm long(1 no)hinges type B-21 100 mm long (2no) suitable handle (1 no) complete all as specified and as directed.
18M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed.
19S&F in repairsof Venetian blinds of wooden finished material width of 50 mm and thickness of 5 mm and size as per direction of Engr-in-charge
20M&L precast cement concrete block massonry with solid block exc 10 cm in width and setting in cm 1:6 type C1 1:3:6 (20mm grades aggreate) complete all as specified.
21M&L for vitrified tiles lightshade (square /rectangular) polished area of each tiles exc 0.36 sqm but nexc 1.00 sqmin floors laid over and incl. 15 mm thk 1:4 screed bed jointed pointed with coloured cement to match the tiles complete all as specified and as directed.
22All as per above itembut in vertical surfaces such as skirting / dado laid over and incl. a backing coat of 10mm thk CM 1:4 complete all as specified and as directed.
23M & L for preparation of new walls surface and applying two coats of distemper oil emulsion over a coat of 1 mm thick wall care putty and one coat of wall primer andcomplete all as specified and directed.
24M&L forfor applying two or more coats(over 1 mm thick plaster of paris wall care putty) of 100% premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resitance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surface on new or previously untreated surfaces all as specified and directed.
25M&L for 60mm thick door with 2mm thick leads sheet with accessories complete as per guidelines for X ray room all as specified and directed.
26M&L for rendering15m thick on fair faces of brick or concrete work in CM 1:4 in two layers with Top 5mm thick mixing with WPC @ 3% by weight of cement over a backing coat of 10mm finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid seperately as supply only.
27Supply only Integral waterproofing compound complete all as specified and as directed.
28M&L for rendering 15 mm thick on fair faces of brick or concrete work in CM 1:6 on brick/concrete surface finished even and smooth without using extra cement complete all as specified and as directed.
29M&L for coats of synthetic enamel paint on new steel surface exc 10 cm in width or girth, on 01 coat of primer (red oxide zinc chome) incl preparation on new surfaces complete all as specified and as directed.
30M&L for PCC 1:3:6 type C-2(using 20 mm graded cr. stone aggr),75mm thick as in plinth protection finished even and smooth without using extra cement layed in bays not exc. 2.00m complete all as specified.
31Returning, filling incl spreading levelling watering and well ramming in layers n exc 25 cm thick each layer complete all as specifed and as directed.
32Removing, excavated material n.exc 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed.
33Dismantling plain or corrugated steel sheet, any guage, thickness incl nainitai or similar pattern as in roof coverings complete all as specified and as directed.
34Taking down chowkat or frame exc 1.5 Sqm but n exc 4 Sqm each (without taking off shutter form the fames ) complete all as specified and as directed.
35Taking down chowkat or frame exc 1.50 Sqm but n exc 4 Sqm each (without taking off shutter form the fames ) complete all as specified and as directed.
36S&L ,2nd class soft wood plain soild, straight chowkats and frames, wrought, framed rebated on thesolid, rounded or chamfered, put togeather with glue pinned at joints complete all as specifed and as directed.
37S&F 30 mm thk Flush door shutters solid core construction with block board core and ply face pannels commercial veneered on both faces complete all as specified and directed.
38M&L glazed skeleton hardwood shutters open rebated and prepared to receive glass gauge etc (without sach bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc 30mm thick of 2nd class hard wood complete all as specified and directed.
39S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
40M&L for 3.00 mm thick sheet glass quality and glazing fixed to aluminium frame nexxc 0.50 sqm complete all as specified and as directed
41M&L for preparation of new wooden surfaces of any description over 10cm in width or grith and treated with two coats of synthetic enamel paint over one coat of pink primer complete all as specified and dierected
42S&F galvanised corrugated mild steel sheeting with two corrugatins side lap, fixed with coach srews and washers in roofs walls ect with garde of zinc coating 120 gms complete all as specified and as directed
43S&F plain galvinsed mild steel sheeting in ridges hips, valley gutter drip and straight flashing (length and girth as fixed) with garade onf zinc coating 120 complete all as specified and directed
44M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab as in floors including rubbing and pollishing completeincluding 15 mm thick screed bed in CM 1:4 all as specified and directed.
45M&L for kota stone floor 18-20 mm thick, as in skirting,set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4 Complete all as specified.
46Dismanting Timber scantlings 40 sqmcm and over in section in any posting framed work complete all as specified and directed
47M&L for wrought secound class hard wood in scantlings frmaed and fixed complete all as specified and directed
48Fixingonly for wrought second class hard wood in scantlings framed and fixed complete all as specified and directed
49M&L for preparation of wood based materials, new or old of any descriptin and girth not otherwise described and treated with creosote oil complete all specified
50M&L for preparation of old wooden surfacesof any description over 10cmin width or girth and treated with one coats of synthetic enamel paint complete al as specified and directed
51Surface dressing n exc 15 cm deep hard/dense soil complete all as specified and as directed.
52Excavation in post holes not exiting 0.5 cum, getting out returing, filling in and ramming earth and broken hard core/rubble mixed with earth with around the layers not exiding 25 cm each layers watering and removing surplus soil to a distance not exceeding 50 cm making good complete all as specified and as directed in soil loose soil.
53M & L 100 mm thick PCC 1:2:4 type B1(20 mm graded) as in subfloors finished even and rough without using extra cement complete all as specified and as directed.
54M&L for Rendering 15mm thick on fair faces of concrete surface of wall in CM (1:4)finished even and smooth without using extra cement all as specified and directed
55M/L precast cement concrete block massonry with solid blocks nexc 10 cm in width and settings in CM 1:4 type C1 1:3:6 (20mm graded aggregate) complete all as specified.
56M&L cement concrete in surface channels and drains type C2 1:3:6 (20 mm graded aggregate ) complete all as specified and as directed.
57Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and as directed.
58M&L forfor applying two or more coats(over 1 mm thick plaster of paris wall care putty) of 100% premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resitance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surface on new or previously untreated surfaces all as specified and directed.
59AGE E/M SCHEDULE Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified and as directed.
60Material andlabour for point wiring with single core PVC insulated unsheathed cable of size 1.5 Sqmm nominal area with multi-stranded FRLSH copper conductor, 1100 Volt grade drawn through and including PVC non metallic surface casing capping of suitable size with all fitting and accessories including PVC modular board of suitable size for housing/mounting the modular switches/sockets, etc top covered with plastic laminated sheet 3mm thick including 1.5 Sqmm PVC insulated unsheathed single core FRLSH copper conductor earth continuity wire connected to common earth dolly completefor one light/fan point controlled by one way switch including making good disturbed surfaces complete all as specified and directed.
61All as per Item No. 60 above but for one 2/3 pin socket outlet, 5 Amps on same board, complete all as specified and directed.
62All as per Item No. 60 above but with FRLSH, ISI marked PVC insulated and unsheathed two single core multistranded copper cable of size 2.5 sqmm for one power point ,3 pin 15 Amps on independent board includingFRLSH, ISI marked PVC insulatedunsheathed single core multi-stranded copper cable of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. Make- Cable- Finolex/RR cable/Havells, PVC Casing Capping- Presto plast/Finolex/Kalinga.
63Description all as per Srl item No.60 above but with 2.5 Sqmm cable for socket outletpoint 5 Amp on Independent board.
64Supply and fixing modular switch 1 way 6A module 230/250 volt , AC supply,ISI Marked, with cover plate complete all as specified and directed.
65Supply and fixing modular sockets 6A 2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover platecomplete all as specified and directed.
66Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
67Supply and fixing modular switch 16A1 module 230/250 Volts,50 Hz , AC supply, ISI Marked, c with cover plate omplete all as specified and directed.
68S & F Modular cover plate with frame & flush box of 6 modules, complete all as specified and as directed. Make- Legrand / Anchoor / vinay
69S & F Modular cover plate with frame & flush box of 4 modules, complete all as specified and as directed. Make- Legrand / Anchoor / vinay
70S & F Modular cover plate with frame& flush box of 3 modules, complete all as specified and as directed. Make- Legrand / Anchoor / vinay
71S & F Modular cover plate with frame& flush box of 2 modules, complete all as specified and as directed. Make- Legrand / Anchoor / vinay
72S & F Modular cover plate with frame & flush box of 1 module, complete all as specified and as directed. Make- Legrand / Anchoor / vinay
73Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. Make:Cona , Plaza, Anchor .
74Supply and fixing LED batten fittings 1x18 Watt complete pre wired fixed to wallwith 2 nos PVC block of suitable size including taking down old unserviceable onecomplete all as specified and as directed.
75S & F Wall bracket decorative LED Spot light Light fitting with lamp10 Watt Aluminium housing complete with necessary connection including taking down old unserviceable one complete all as specified and as directed. Make: Crompton- CDR-211-09-40-SL-NWH / Bajaj BRDCSL9 watt WW / PhilipsRS378ZM55D75 WW
76S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB complete all as specifided and as directed Make- Legrand/L&T/ C&S
77Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified.. (Note:MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule .Note:Copper thimble shall be used for connection of cable .
78Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB"s.Make : Hageras per cat part- NCN106N, Schneider as per cat No : A9N4P32C or Indoasian as per cat No : 81195.
79Supply and fix MCB TPN, 240 Volts, 40 to 63Amps, 10 kA rupturing capacity415 Voltscomplete all as specified and directed including taking down old one.
80M & L Sub main wiring with four run single core 10 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC ConduitISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 10Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Four runs of 10 sqmm and one run of 10 sqmm cable and one run of PVC conduitshall be measured as one RM.
81Material and labour for earthing complete withcopper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to 20×3mm copper strip by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 20 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing and taking down old complete all as shown in Electrical Plate No 3 of SSR part -I.
82Material and Labour for Shifting the existing AC form one location to another locations, including reconnection with copper pipes, insulations, Gas charging including testing completeall as specified and directed by Engr-in-Charge