Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-07-2023 | CORRIGENDUM-1 | Date | 20-07-2023 |
| 2 | 22-06-2023 | CORRIGENDUM-1 | Technical Bid | 12-07-2023 |
| Sl. No. | Item Description |
| 1 | BUILDING |
| 2 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area and complete the work in all espect as directed by EIC. |
| 3 | Supplying, diluting and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 liters (or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc.complete as per IS:6313 / 1981 (Part-II) and asper the direction of theEngineer-in-charge including cost of all materials, labour, taxes, etc. complete. |
| 4 | Earthwork in excavation of foundation trenches for columns, basement, tie beams, walls and steps in ordinary soil with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In ordinary soil Upto 1.5m depth |
| 5 | Earthwork in excavationby cutting in foundation trenches for columns, basement, tie beams, walls and steps in disintegrated rock not requiring blasting to be removed by pick axes and crow bars with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In Hard soil Upto 1.5m depth. |
| 6 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In Hard Rock Blasting Prohibited Upto 1.5m depth. |
| 7 | Earthwork in excavation of foundation trenches for columns, basement, tie beams, walls and steps in ordinary soil with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In ordinary soil 2nd lift from 1.50M to 3.00 Mtr depth. |
| 8 | Earthwork in excavationby cutting in foundation trenches for columns, basement, tie beams, walls and steps in disintegrated rock not requiring blasting to be removed by pick axes and crow bars with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In Hard soil 2nd lift from 1.50M to 3.00 Mtr depth. |
| 9 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches including dressing of sides and ramming of bottoms, lift upto 3.0 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In Hard Rock Blasting Prohibited 2nd lift from 1.50M to 3.00 Mtr depth. |
| 10 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers Eacht exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. |
| 11 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved qry, laying in layers Eacht exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 12 | Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm Nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved qry including laying in the layers Eacht exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 13 | Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm Nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved qry including laying in the layers Eacht exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 14 | Providing & laying cement concrete of prop. (1:2:4) in foundation bed and floors using 12mm Nominal size, screened, washed hard black crusher broken granite chips of approved quality & from approved qry including laying in the layers Eacht exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 15 | Brick work in Sub-Structure with flyash bricks of size 25x12x8cm in cement mortar (1:4) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge Foundation and Plinth. |
| 16 | Brick work in Super-Structure with flyash bricks of size 25x12x8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge.In G Floor |
| 17 | Brick work in Super-Structure with flyash bricks of size 25x12x8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. In 1st Floor |
| 18 | Brick work in Super-Structure with flyash bricks of size 25x12x8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. In 2nd Floor |
| 19 | Brick work in Super-Structure with flyash bricks of size 25x12x8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. In 3rd Floor |
| 20 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grillsin Foundation & padestral |
| 21 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Column in G Floor |
| 22 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grillsin Column in 1st Floor |
| 23 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grillsin Column in 2nd Floor |
| 24 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grillsin Column in 3rd Floor |
| 25 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grillsin Plinth beam |
| 26 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in lintel in G Floor |
| 27 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in lintel in 1st Floor |
| 28 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in lintel in 2nd Floor |
| 29 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in lintel in 3rd Floor |
| 30 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Roof beam in G Floor |
| 31 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Roof beam in 1st Floor |
| 32 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Roof beam in 2nd Floor |
| 33 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Roof beam in 3rd Floor |
| 34 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in CHAJJA in G Floor |
| 35 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in CHAJJA in 1st Floor |
| 36 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in CHAJJA in 2nd Floor |
| 37 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in CHAJJA in 3rd Floor |
| 38 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in STAIRCASE in G Floor |
| 39 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in STAIRCASE in 1st Floor |
| 40 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in STAIRCASE in 2nd Floor |
| 41 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in STAIRCASE in 3rd Floor |
| 42 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in ROOF SLAB in G Floor |
| 43 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in ROOF SLAB in 1st Floor |
| 44 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in ROOF SLAB in 2nd Floor |
| 45 | R.C.C. work ofM-30 having minimum compressive strength of 300kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in ROOF SLAB in 3rd Floor |
| 46 | R.C.C. work ofM-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Foundation and base in top floor |
| 47 | R.C.C. work ofM-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Wall in top Floor |
| 48 | R.C.C. work ofM-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Roof Slab in 2nd floor |
| 49 | R.C.C. work ofM-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Beam, Column etc in Top floor |
| 50 | R.C.C. work ofM-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. in Roof Slab Top Floor |
| 51 | Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost, conveyance of HYSD bars Fe500 and above including binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC.. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.).in G Floor |
| 52 | Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost, conveyance of HYSD bars Fe500 and above including binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC.. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.). in 1st Floor |
| 53 | Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost, conveyance of HYSD bars Fe500 and above including binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC.. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.). in 2nd Floor |
| 54 | Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost, conveyance of HYSD bars Fe500 and above including binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC.. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.). in 3rd Floor |
| 55 | 12mm (1/2\") thick cement plaster (1:6) for finished smooth to inside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in G Floor |
| 56 | 12mm (1/2\") thick cement plaster (1:6) for finished smooth to inside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in 1st Floor |
| 57 | 12mm (1/2\") thick cement plaster (1:6) for finished smooth to inside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in 2nd Floor |
| 58 | 12mm (1/2\") thick cement plaster (1:6) for finished smooth to inside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in 3rd Floor |
| 59 | 16mm (5/8\") thick cement plaster (1:6) for finished smooth to outside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in G Floor |
| 60 | 16mm (5/8\") thick cement plaster (1:6) for finished smooth to outside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in 1st Floor |
| 61 | 16mm (5/8\") thick cement plaster (1:6) for finished smooth to outside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in 2nd Floor |
| 62 | 16mm (5/8\") thick cement plaster (1:6) for finished smooth to outside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in 3rd Floor |
| 63 | 6mm thick cement plaster (1:4) to RCC surfaces after necessary cleaning and scrapping the RCC surface including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. in G Floor |
| 64 | 6mm thick cement plaster (1:4) to RCC surfaces after necessary cleaning and scrapping the RCC surface including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. in 1st Floor |
| 65 | 6mm thick cement plaster (1:4) to RCC surfaces after necessary cleaning and scrapping the RCC surface including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. in 2nd Floor |
| 66 | 6mm thick cement plaster (1:4) to RCC surfaces after necessary cleaning and scrapping the RCC surface including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. in 3rd Floor |
| 67 | 12 mm thick cement plaster (1:4) to RCC / Masonry surfaces after necessary cleaning and scrapping the RCC surface including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. in Ground Floor |
| 68 | 12 mm thick cement plaster (1:4) to RCC/ Masonrysurfaces after necessary cleaning and scrapping the RCC surface including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. in 3rd Floor |
| 69 | Finishing wall surface with powder wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T & P etc complete as per direction of Engineer-in-charge. in G Floor |
| 70 | Finishing wall surface with powder wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T & P etc complete as per direction of Engineer-in-charge. in 1st Floor |
| 71 | Finishing wall surface with powder wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T & P etc complete as per direction of Engineer-in-charge. in 2nd Floor |
| 72 | Finishing wall surface with powder wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T & P etc complete as per direction of Engineer-in-charge. in 3rd Floor |
| 73 | Providing & Applying priming one coat with Cementbase primer of approved brand and manufacture onplaster/putty surface as per the instruction of Engineer-In-Charge at all elevations including cost of all material & labour T & P etc complete as per direction of Engineer-in-charge.in G Floor |
| 74 | Providing & Applying priming one coat with Cementbase primer of approved brand and manufacture onplaster/putty surface as per the instruction of Engineer-In-Charge at all elevations including cost of all material & labour T & P etc complete as per direction of Engineer-in-charge. in 1st Floor |
| 75 | Providing & Applying priming one coat with Cementbase primer of approved brand and manufacture onplaster/putty surface as per the instruction of Engineer-In-Charge at all elevations including cost of all material & labour T & P etc complete as per direction of Engineer-in-charge. in 2nd Floor |
| 76 | Providing & Applying priming one coat with Cementbase primer of approved brand and manufacture onplaster/putty surface as per the instruction of Engineer-In-Charge at all elevations including cost of all material & labour T & P etc complete as per direction of Engineer-in-charge. in 3rd Floor |
| 77 | Preparing surface and painting with two or more coats of interior Plastic Emulsion \"Royale Shyne\" of Asian Paints or equivalent of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. over interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. in G Floor |
| 78 | Preparing surface and painting with two or more coats of interior Plastic Emulsion \"Royale Shyne\" of Asian Paints or equivalent of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. over interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. in 1st Floor |
| 79 | Preparing surface and painting with two or more coats of interior Plastic Emulsion \"Royale Shyne\" of Asian Paints or equivalent of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. over interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. in 2nd Floor |
| 80 | Preparing surface and painting with two or more coats of interior Plastic Emulsion \"Royale Shyne\" of Asian Paints or equivalent of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. over interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. in 3rd Floor |
| 81 | Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete.in G Floor |
| 82 | Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete. in 1st Floor |
| 83 | Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete.in 2nd Floor |
| 84 | Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete.in 3rd Floor |
| 85 | 12mm thick C.P.(1:4) with neat cement punning for finished smooth to masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. in All Floor |
| 86 | Supplying , fitting and fixing vitrified tile (Matt/Gloss) in floor having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm of approved quality and shadein all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in G Floor |
| 87 | Supplying , fitting and fixing vitrified tile (Matt/Gloss) in floor having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm of approved quality and shadein all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in 1st Floor |
| 88 | Supplying , fitting and fixing vitrified tile (Matt/Gloss) in floor having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm of approved quality and shadein all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.. in 2nd Floor |
| 89 | Supplying , fitting and fixing vitrified tile (Matt/Gloss) in floor having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm of approved quality and shadein all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in 3rd Floor |
| 90 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings with moulding edge & Grooving etc.on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. In G Floor |
| 91 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings with moulding edge & Grooving etc.on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. In 1st Floor |
| 92 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings with moulding edge & Grooving etc.on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. In 2nd Floor |
| 93 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings with moulding edge & Grooving etc.on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. In 3rd Floor |
| 94 | Supplying all materials, labour, T&P and fixing antiskid Ceramic floor tile of 300mmx300mm size of approved brand and shade on 25mm thick cement mortar (1:4) (1 cement:4 sand)jointed with neat cement, slurry mixed with pigment to match the shed of tiles complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work. in G Floor |
| 95 | Supplying all materials, labour, T&P and fixing antiskid Ceramic floor tile of 300mmx300mm size of approved brand and shade on 25mm thick cement mortar (1:4) (1 cement:4 sand)jointed with neat cement, slurry mixed with pigment to match the shed of tiles complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work. in 1st Floor |
| 96 | Supplying all materials, labour, T&P and fixing antiskid Ceramic floor tile of 300mmx300mm size of approved brand and shade on 25mm thick cement mortar (1:4) (1 cement:4 sand)jointed with neat cement, slurry mixed with pigment to match the shed of tiles complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work. in 2nd Floor |
| 97 | Supplying all materials, labour, T&P and fixing antiskid Ceramic floor tile of 300mmx300mm size of approved brand and shade on 25mm thick cement mortar (1:4) (1 cement:4 sand)jointed with neat cement, slurry mixed with pigment to match the shed of tiles complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work. in 3rd Floor |
| 98 | Supplying , fitting and Fixing full body glazed /Matt vitrified tile in dado/ skirting using vitrified tileshaving thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved qualityof Somany/ Kajaria or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in G Floor |
| 99 | Supplying , fitting and Fixing full body glazed /Matt vitrified tile in dado/ skirting using vitrified tileshaving thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved qualityof Somany/ Kajaria or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in 1st Floor |
| 100 | Supplying , fitting and Fixing full body glazed /Matt vitrified tile in dado/ skirting using vitrified tileshaving thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved qualityof Somany/ Kajaria or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in 2nd Floor |
| 101 | Supplying , fitting and Fixing full body glazed /Matt vitrified tile in dado/ skirting using vitrified tileshaving thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved qualityof Somany/ Kajaria or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. in 3rd Floor |
| 102 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in dado and skirting of approved quality, colour and size with moulding edge & Grooving etc.on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. in G Floor |
| 103 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in dado and skirting of approved quality, colour and size with moulding edge & Grooving etc.on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. in 1st Floor |
| 104 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in dado and skirting of approved quality, colour and size with moulding edge & Grooving etc.on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. in 2nd Floor |
| 105 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in dado and skirting of approved quality, colour and size with moulding edge & Grooving etc.on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.in 3rd Floor |
| 106 | Providing & Fixing tiles of 600 x 300mmspecial plain/ printed series ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. In G Floor |
| 107 | Providing & Fixing tiles of 600 x 300mmspecial plain/ printed series ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. In 1st Floor |
| 108 | Providing & Fixing tiles of 600 x 300mmspecial plain/ printed series ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. In 2nd Floor |
| 109 | Providing & Fixing tiles of 600 x 300mmspecial plain/ printed series ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. In 3rd Floor |
| 110 | Supplying,fitting,fixing M.Sgrill or grill gateetc. made out of structural steel angle,square bars flats as per design and drawing fixed in proper position with grouted clapms including making good to the damages of walls and floors in all floors including cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC. In All Floor |
| 111 | Providing & Applying priming coat with ready mixed pink or gray primer of approved brand and manufacture on Iron work (hard and soft wood) as per the instruction of Engineer-In-Charge at all elevationsincluding cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC. in G Floor |
| 112 | Providing & Applying priming coat with ready mixed pink or gray primer of approved brand and manufacture on Iron work (hard and soft wood) as per the instruction of Engineer-In-Charge at all elevationsincluding cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC. in 1st Floor |
| 113 | Providing & Applying priming coat with ready mixed pink or gray primer of approved brand and manufacture on Iron work (hard and soft wood) as per the instruction of Engineer-In-Charge at all elevationsincluding cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC. in 2nd Floor |
| 114 | Providing & Applying priming coat with ready mixed pink or gray primer of approved brand and manufacture on Iron work (hard and soft wood) as per the instruction of Engineer-In-Charge at all elevationsincluding cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC. in 3rd Floor |
| 115 | Painting two coats with approved brand of synthetic enamel paint of approved shade and quality to iron/wood works including cost of paint, primer, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC.In G Floor |
| 116 | Painting two coats with approved brand of synthetic enamel paint of approved shade and quality to iron/wood works including cost of paint, primer, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC. In 1st Floor |
| 117 | Painting two coats with approved brand of synthetic enamel paint of approved shade and quality to iron/wood works including cost of paint, primer, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC. In 2nd Floor |
| 118 | Painting two coats with approved brand of synthetic enamel paint of approved shade and quality to iron/wood works including cost of paint, primer, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC.In 3rd Floor |
| 119 | Providing and fixing factory made WPC door frame of 125X65mm size made of WPC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 5.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screwsand fixed in wall with SS anchor bolt including cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC.in all floors |
| 120 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames including cost,conveyance of materials cost of all labour,T & P etc. required complete as per direction of EIC. in all floor |
| 121 | Providing, fitting and fixing of 32mm thick BWR flush door Partly Glazed with 8mm glass & both side laminated with premium qualiyt laminates as per the specification complete with all materials, inclusive of all steel hardware material, hinges, nails, screws, doorknobs, handles,stopper etc. including the cost of all materials, labour and T&P and overheads etc. complete. The exposed wood work shall be finished with automotive paint. two coats with primer. The rates also includes the cost of 40 x 25mm wooden beading for the partition in front of the door and finished with automotive paints and as per direction of EIC. in all floors |
| 122 | Supplying, fitting, fixing up window (sliding/Fixed type) made up powder coated aluminum Section 151-154, 151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick Reflective glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-in-charge. |
| 123 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 25mm X 25mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. |
| 124 | 2.5cm thick grading concrete (1:2:2) on roof slab withgraded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer\"s specification on top of slab including cement slurry including hoisting and laying concrete,watering and curingincluding cost, conveyance, royalities of all materials, cost of all labour, T & P required for the work etc.required to complete as per direction of EIC. in G Floor |
| 125 | 2.5cm thick grading concrete (1:2:2) on roof slab withgraded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer\"s specification on top of slab including cement slurry including hoisting and laying concrete,watering and curingincluding cost, conveyance, royalities of all materials, cost of all labour, T & P required for the work etc.required to complete as per direction of EIC. in 1st Floor |
| 126 | 2.5cm thick grading concrete (1:2:2) on roof slab withgraded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer\"s specification on top of slab including cement slurry including hoisting and laying concrete,watering and curingincluding cost, conveyance, royalities of all materials, cost of all labour, T & P required for the work etc.required to complete as per direction of EIC. in 2nd Floor |
| 127 | Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer\"s specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge in 3rd Floor |
| 128 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-30 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.of Arch, Vaults, Dome span upto 6m. in 2nd Floor |
| 129 | Centering and shuttering including strutting, propping etc. and removal of form for Arches, domes, vaults up to 6 m span with semicircular arch 3.6m clear span and 3.6m long Frame work using Galvanized steel plain sheets,Second class kail wood in scantling, safeda ballis2nd class kail wood Tie, Struts, bracings, sleepers, vertical post and Ribs etc, mild steel flats nut bolt as required including cost of all materials, T&P, labour etc to complete the work as directed by EIC. |
| 130 | Providing and fixing of storage cabinet with shutter and shelves in the inside made up of 19mm thick BWR block board & 6mm thick BWR ply back side cover and finished with 1mm thick laminates and wooden beading. The beading and internal surfaces are to be painted with automotive paint as per drawing, design and specifications including all SS fittings (auto hinge, handle, magnetic catcher PVC buffer, stud 1” / 2.5” cup board lock as required & specified in design) etc. cost of all materials, cost of all labour and T&P required to complete as per direction of EIC. (BWR board/ Ply of Green ply/ Century Ply / Gattani / Sylvan and laminates of Green lam / Signor / Merino / Archidlam are to be used) Storage Almirah |
| 131 | Providing and fixing of storage cabinet with shutter and shelves in the inside made up of 19mm thick BWR block board & 6mm thick BWR ply back side cover and finished with 1mm thick laminates and wooden beading. The beading and internal surfaces are to be painted with automotive paint as per drawing, design and specifications including all SS fittings (auto hinge, handle, magnetic catcher PVC buffer, stud 1” / 2.5” cup board lock as required & specified in design) etc. cost of all materials, cost of all labour and T&P required to complete as per direction of EIC. (BWR board/ Ply of Green ply/ Century Ply / Gattani / Sylvan and laminates of Green lam / Signor / Merino / Archidlam are to be used) Bottom storage |
| 132 | Providing and applying Texture paint of approved quality and colour and make to the plastered surfaces of internal walls and on ply surface including priming one coat of exterior wall andcost, coveyance of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. (Two or more coats applied @ 3.28 ltr / 10Sqm) |
| 133 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-in-charge. |
| 134 | Providing, laying, spreading and compacting graded stone aggregate (Gr-II)to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 404 of MoRT&H specifications for Road & Bridgeworks (5th Revision) and as per direction of EIC. |
| 135 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) etc complete as per direction of Engineer-in-charge. |
| 136 | Supplying and laying of M40 grade heavy duty factory made hydraulically pressed and mechanically compacted free castpavers of 60mm thick, coral shaped preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-chrge. |
| 137 | Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408, drawing / design and as per direction of EIC. |
| 138 | Supply of good quality garden soil preferably red alluvial /sandy loam with texture neither too coarse nor too fine with a fair degree of water retaining capacity sufficiently porous for microbial activity, containing adequatehumus with a Ph range from 6.5 to 7.5 should be freefrom any undesirable inorganic materials like wastages of construction, roots and bushes of wild plants, polythene, garbage etc., to be collected after duly screened including cost, conveyance, royalty, taxes andother chargeswith labour and T & P charges for loading, unloading and stacking at site in the separate heaps of ( 1.5 x 1.5x 0.5) Cumor its multiples taken into 1(one) Cum for measurement and payment purposes and completed in all respect for the park. |
| 139 | Supplying, collecting and stacking of good sand for field including cost, conveyance, royalty, taxes of all materials,labour etc. complete as per specification and direction of Engineer-in-Charge. |
| 140 | Supply of cow dung manure, well decomposed, garbage free, one Tractor load including loading, unloading and delivery at site etc. complete as per direction of EIC. |
| 141 | Mixing earth and sludge or manure in proportion specified including cost of labour & T &P etc Spreading of sludge, dump manure or land good earth in required thickness.and compacting with PRR as per direction of EIC. (Cost of sludge, dump manure or/and good earth to be paid separately). |
| 142 | Providing and laying Selection No-1 Joyasia grass turf with earth 50mm to 60mm thickness of existing groundand Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of up rooted vegetation with all lead and lift with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and maintenance for 30 days or more till the grass establish properly etc. complete as per direction of EIC. |
| 143 | Providing and transplanting best quality SHRUBS AND HEDGES Bauhinia tomentosa,caesalpinia,calliandra haematocephala,Cassia biflora,Cestrum diurmum,Cyprus rotundus,Duranta goldii,Duranta vanegated,ficus blakei,Ficuspanda,Jasminum spp,Strelitzia regia,Tecoma stans, Thuja spp,Vinca rosea et of approx height 450-900 mm in erect position without breaking the earth balls around the roots,packing the soil tight around the plantand water properly ,including preparation of beds for hedging and shrubbery by excavating 600x600 mm deep etc. complete as per direction of EIC. |
| 144 | Providing, displaying and planting of Areca Palm plant, having ht. 1.80 cm to 2.00 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot / Plastic pot & as per direction of the EIC. |
| 145 | Construction of embankment with approved materials deposited at site from road-way cutting and excavation from drain and foundation of other structures,graded and compacted to meet requirement of Table 300-2 as per appd. drawing and technical specification as per clause 305 of MoRT&H specifications of road & bridge works (5th revision) |
| 146 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: Details available at SBD Clause No: 3.24 |
| 147 | Supplying all materials for positioning and fixing of Pre-Cast RCC M-25 slab of size100mmX200mm in wall after cutting grooves of size 125mm X 125mm andmending good to the damages in wall, 12mm thick CP (1:4) over insert slab to finished the surface including cost of all materials, T&P, labour etc to complete the work as directed by EIC. |
| 148 | Fixing ofModified clay material (Slate Sunnye /Slate Phantom) tiles claddingin wall on 12mm thick cement plaster (1:3)jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage, cost of all labour, T&P required to complete the work. |
| 149 | Supplying all materials for providing RCC M-30 projected copping over dome slab of size(100mmX100mm/ as required) with necessary shuttering as required including finished the surface including cost of all materials, T&P, labour etc to complete the work as directed by EIC. |
| 150 | 2.5 Cm. (1\") thick A.S. flooring with C.C. (1:2:4) including punning using 12mm size black hard crusher broken granite chips laid over PCC (1:3:6) proper slope including rounding of corners, watering and curing with cost, conveyance, royalties of all materials and cost of all labour, T&P required for the work etc. complete as per the specification & direction of EIC |
| 151 | Supplying all materials, labour,T&Pfor laying of Synthetic Turf for badminton court as per sports India approved, The product consistPVC wear layer, ECO friendly, high wear resistance over non woven glass fibre poly mesh layer, pvc reinforced layer, high density forming buffer layer with fit flex adsorptive prevent movement bottom layer anf fix with necessary adhesive for fix in floorincluding cost of all materials, T&P, labour etc to complete the work as directed by EIC. Make- SunZone/Rebound Ace/ |
| 152 | Supplying, fitting and fixing of colour G.C.I sheet (0.40mm thick) in roof including shaft sealing screw etc. complete with cost, conveyance of all required fitting as directed by EIC. (GCI Sheet of Jindal./ TATA BLUE SCOPE) |
| 153 | Supplying,fitting,hoisting, joist, M.S.Angle trusses of required span, purlines of required size and MS Hallow tubes as required and placing in positionincluding cost of nut &bolts, necessary welding and polishing and all other materials required for the work, cost of all labour, T&P etc.complete as per specification approved by IIT/NIT/Govt Institute drawing & direction of EIC. |
| 154 | Design of MS Structure for Multipurpose Hall and vetted from IIT/NIT/Govt Institution cosidering the soil stability, air flow and other espects and submit the same in hard copy. |
| 155 | WATER SUPPLY AND SANITARY INSTALLATION |
| 156 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Polyvinyl Chloride pipes (UPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40withfitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace& PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. in Ground Floor |
| 157 | 20 mm dia U-PVC pipe |
| 158 | 25 mm dia U-PVC pipe |
| 159 | 32 mm dia U-PVC pipe |
| 160 | 40 mm dia U-PVC pipe |
| 161 | 50 mm dia U-PVC pipe |
| 162 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Polyvinyl Chloride pipes (UPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40withfitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace& PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. in First Floor |
| 163 | 20 mm dia U-PVC pipe |
| 164 | 25 mm dia U-PVC pipe |
| 165 | 32 mm dia U-PVC pipe |
| 166 | 40 mm dia U-PVC pipe |
| 167 | 50 mm dia U-PVC pipe |
| 168 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Polyvinyl Chloride pipes (UPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40withfitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace& PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. in Second Floor |
| 169 | 20 mm dia U-PVC SH-40 pipe |
| 170 | 25 mm dia U-PVC pipe |
| 171 | 32 mm dia U-PVC pipe |
| 172 | 40 mm dia U-PVC pipe |
| 173 | 50 mm dia U-PVC pipe |
| 174 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40withfitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace& PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. in Third Floor |
| 175 | 20 mm dia U-PVC pipe |
| 176 | 25 mm dia U-PVC pipe |
| 177 | 32 mm dia U-PVC pipe |
| 178 | 40 mm dia U-PVC pipe |
| 179 | 50 mm dia U-PVC pipe |
| 180 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (UPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40withfitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace& PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. in Terrace Floor |
| 181 | 50 mm dia U-PVC pipe |
| 182 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall |
| 183 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 184 | SANITARY FIXTURES |
| 185 | Supplying all materials, labour, T&P and fixing the wall mounted Rimless Single Piece-WC with UF slim seat cover, Hinges, Fixing Accessories and Accessories Set, Cistern Fittings, including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge. MAKE JAQUAR-FLS-WHT-5353PPZ |
| 186 | Supplying all materials, labour, T&P and fixing the following vitreous china WashWater Closet & Cistern fitting (European type W.C. pan) with integral \"p\" or \"s\" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge. JAQUAR-CNS-WHT-551SNPP184LZ |
| 187 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of theEngineer-In-Charge.JAQUAR-ALD-577 Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) |
| 188 | Supplying all materials, labour, T&P and fixing standard sized LONG BODY Bib cockWITH WALL FLANGE ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with FlangeCat. No.: F330011 HINDWARE |
| 189 | Supplying all materials, labour, T&P and fixing standard sized two wayBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with Flange. JAQUAR -FLR-5041N 2 Way Bib Cock with Wall Flange |
| 190 | Supplying all materials, labour T&P and fixing Wall Hung &Half Pedestal type wash basins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered \"Hot\" and \"Cold\" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of theEngineer-In-Charge. jaquar-CNS-WHT-811,CNS-WHT-303, Bottle Trap-ALD-769L250x190, waste copler ALD-709L130 |
| 191 | Matrix Set-1 (WB 65X35 with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, WH Basin, one no hinged rail 76 cm and five nos of grab rail 60cm)Make-jaquar E.W.C,(Size- 390 x 365 x 540, S TRAP) cm ,Cat No-jaquar CNS-WHT-551S& Cistern completewith fittings & seat cover,Wash Basin : 46 x 36 cm, one no. hinged rail 76 cm & 4 nos. of grab rails 60 cm./ Hindware Matrix set 70002. |
| 192 | Supplying all materials, labour T&P and fixing of Under Counter wash basins of Hindware/Jaquar/Parryware of approved make in all floor of approved quality including cutting the walls & floor and making good the damags with cement concrete e.t.c including all tsxes,duties,transportation e.t.c. All complete as per specification and direction of theEngineer-In-Charge.jaquar-CNS-WHT-701, Bottle Trap-ALD-769L250x190, waste cupler-ALD-709L130. |
| 193 | Supplying all materials, labour, T&P and fixing standard sizedChromium PlatedShower with shower arm complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. SHOWER HEAD-JAQUAR-OHS-1789,SHOWER ARM-SHA-477,ANGULAR STOP COCK-JAQUAR-FLR5083NK &JAQUAR-ALD-089 |
| 194 | Supplying all materials, labour, T&P and fixing standard sized 15mm pillar cock ofof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock.(MAKE -JAQUAR -FLR-5015 Pillar Cock) |
| 195 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick WPC sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge.Swivel MirrorRectangular Shape(600x450) |
| 196 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated Glass Shelf 600mm long ofcomplete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge.jaquar-ACN-1171N |
| 197 | Supplying all materials, labour, T&P and fixing standard sized 600 mm Towel Rail ofcomplete with all as per specification and direction of the Engineer in charge. jaquar-ACN-1111SM |
| 198 | Supplying all materials, labour, T&P and fixing standard sized15mm dia angular Stop cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. Jaquar Essco. |
| 199 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap case complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. jaquar CAN-1131N |
| 200 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap dispenser with glass bottle complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. JAQUAR -ACN-1135N |
| 201 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brasstowel ring ofcomplete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. Jaquar ACN-1121BN |
| 202 | Fixing of 25 mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- Zoloto or equivalent.) |
| 203 | Fixing of 32 mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 204 | Fixing of40 dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 205 | Fixing of 50 dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 206 | OPENWELL SUBMERSIBLE PUMP - DOMESTIC WATER SUPPLY FROM UGR TO OVERHEAD TANK Supply, installation & commissioning of openwell submersible horizontal single/multi stage pump with vertical discharge port and integrated submersible single phase TEFC induction motor designed for S1 Duty with mechnical seal Ceramic Vs Graphite . Pump should be with \"Noryl & cast iron(CED Coated) impeller\", \"Stainless steel Shaft , Pump body & Thrust ring\" and Volute casing Cast Iron material of construction with 1x 220-240 V, 50 Hz 2 Pole. 0.7 KW (1. HP aprrox) motor, Enclosure Class IP 68, Insulation Class B.Pump Inlet & outlet should be 25 mm dia and supply with PVCL bend strainer and cable jointing Kit.Each Pump Flow Rate- 6000 LPH (1W+1S) Head- 15 m,Location : UGR TANK |
| 207 | Single Phase Controller Panel for Domestic Openwell submersible Pump Supply, Installation & commisioning of Digital Pump Controller for each pump with automatic operation through 2 nosfloat switch sensor in both OHT filling & dry run protection in UGR, IP 41 Enclosure. |
| 208 | Supplying all materials, labour T&P for fitting and fixing 550x440mm of approved make IWC Pan with 4\" dia PVC \"P\" trap including supply of necessary jointing materials, cement concrete, sand etc. for fixing the pan, \"P\" trap including cutting the floor and making good to the damages etc. all complete as per direction of EIC and as per PH specification. (Make: Hindware-ORISSA PAN (COMFORT) Cat. No.: 20070 |
| 209 | Supplying all materials, labour T&P and fitting and fixing of 10 ltr. Capacity PVC Low level flushing cistern with flush bend and a pair of white enameled coat iron bracket 12mm dia PVC inlet connection pipe (0.45 m long) with brass union including cutting hole and making good to the same and connecting the inlet pipe with supply main etc. all complete as per specification and direction of EIC. (Make: Hindware-SLEEK FRESH DUAL FLUSH |
| 210 | Supplying all materials, labour, T&P and fitting & fixing 15mm dia CP bib cock with supply ofjointing materials completeas per specification and direction of the Engineer in charge.(Make: Jaquar Essco |
| 211 | Providing all materials, labour,T&P and fittings and fixing of flush valve of Jaquar Cat. No.-PRS 073 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 212 | Supplying all materials, labour, T&P and fixing Flat backurinal with speader of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.Jaquar-URS-WHT-13261,ALD1043/1041. |
| 213 | Providing and fixing Curved urinal partitions of size 450mm as per direction of Engineer -in-chief and finished smooth. (Make:- Parryware/Hindware/Jaquar) |
| 214 | Supply, Installation, Testing and Commissioning of GEYSER 15 LTR capacity (MAKE -JAQUAR ELENA PRIME- 2KW) |
| 215 | Supplying, fixing and testing of kitchen Sink Stainless steel kitchen sink including fixing in position with necessary brackets cutting of slabs etc of size 585x485mm bowl depth 200 mm NIRALI GLISTER SUPER) |
| 216 | Supplying, fixing and testing of kitchen Sink Stainless steel kitchen sink including fixing in position with necessary brackets cutting of slabs etc of size685x510mm bowl depth 250 mm NIRALI GLISTER Jumbo) |
| 217 | Supplying all materials, labour, T&P and fixing standard sized SINK cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.JAQUAR-FLR-5347N |
| 218 | Supplying all materials, labour, T&P and fixing standard sized ROBO Double Hook of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.JAQUARACN1161N |
| 219 | Fixing Rotational moulded Poly Propelene double layer cylindrical vertical water storage tanks confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge. 2000 Ltr Cintex/Supreme |
| 220 | Fixing Rotational moulded Poly Propelene double layer cylindrical vertical water storage tanks confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge. 1000 ltr Cyntex/Supreme |
| 221 | SEWAGE SYSTEM. |
| 222 | Supplying all materials, labour, T & P and constructing of Inspection chamber(IC) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge.Size- 760 x760x760 mm |
| 223 | Providing and fixing square mouth S.W GULLY TRAP Size- 300x300 mm(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge |
| 224 | Supplying all materials, labour, T & P and constructing of MAN HOLE chamber(M H)size 900x800x450mmof the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 225 | Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR)confirming to IS13592 : 1990, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini 40 mm dia . |
| 226 | Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR)confirming to IS13592 : 1990, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini50 mm dia . |
| 227 | Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR)confirming to IS13592 : 1990, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini75 mm dia |
| 228 | Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR)confirming to IS13592 : 1990, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini110 mm dia |
| 229 | Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR)confirming to IS13592 : 1990, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini110 mm dia Rain pipe. |
| 230 | Supplying, fixing and testing PVC multi floortrap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., 40mm x 75 mm dia |
| 231 | Supplying, fixing and testing PVC Nahani trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete 75 mm dia |
| 232 | Providing ,fixing , testing and commissioningof approved make PVC vent cowl with necessary accessories etc., complete. 75 mm dia |
| 233 | Providing ,fixing , testing and commissioningof approved make PVC vent cowl with necessary accessories etc., complete. 110 mm dia |
| 234 | Providing ,fixing , testing and commissioningof approved make Clean Out 75 mm diawith necessary accessories etc., complete |
| 235 | Providing ,fixing , testing and commissioningof approved make Clean Out 110 mm diawith necessary accessories etc., complete |
| 236 | Supplying all materials, labours,T&p and laying trenches(to level or slope) unplasticized P.V.C pipe conforming to IS4985/2016 of the following out side dia forpressure rating PN-6including jointing with supplyof approved solvent cement by non-heat application method/as per manufacture\"s specification,providing and laying in trench cement concrete(1:4:8) with40 mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing e.t.c all complete as per P.H specification and direction of the Engineer in charge 160 mm dia U-PVCpipe with al-round concreteing |
| 237 | Construction 30 user septic tank of approved size inside dimension as per PH specification and drawing with Earth work excavation in all kinds of soil, CC (1:4:8) in foundation with 1st class F.B Brick in C.M (1:4), 6 mm CP in C.M (1:4), 12mm thick CP in C.M (1:4) with neat cement punning, CC (1:2:4) using 12mm size h,b,g chips in floors with RCC M-20 in Baffle wall, cover slab of thickness 100mm ,16mm dia M.S. Bar of 0.9 Mtr long for M.S. STEP with CI manhole cover,150mm dia PVC vent pipe, PVC cowel and required PVC pipe etc. complete as per specification and direction of EIC. (The drawing and design will be supplied by EIC). As per approved plan of EIC. |
| 238 | Supplying all materials,labours,T&P and constructing 1.22m dia and 2.1m depth soakway pit with precast RCC rings joined loose,gravel backing in the rear of well steining,precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty etc all complete as per approved specification and direction of Engineer-in-charge. (The drawing and design will be supplied by EIC). |
| 239 | Supplying all materials for constuction of Wash hand counter of 450x450mm with RCC base and wall finished with Granite and Ceramic tiles of large size |
| 240 | STP SEWAGE TREATMENT PLANT OF 125 KLD CAPACITYMECHANICAL(MAKE-WATER ODISHA)Design, supplying, installing, testing & commissioning of SewageTreatment plant of capacity 125 KLD(excluding all Civil & construction work) for the following duty: Nature of Sewage- Domestic Sewage, Daily average flow -125 Cum/daypH - 6.5 – 8.5 BOD5 - upto 100-200 Mg/L S. Solids - 100-250 Mg/L COD - upto 400 Mg/L Oil & Grease - 30 Mg / L Coliform - 106 - 107 MPN/100 ML Sewage discharge standard after treatment PH - 5.5-9.0 BOD5 - Less than 20 Mg/L S. Solids - Less than 20 Mg/L COD - Less than 50Mg/L Coliform – traces |
| 241 | Supply, installation, testing & commissioning of Stainless Steel Perforated, 6mm perforated Bar Screen with suitable lifting arrangementwith brackets in the sreen sump of (size 600 mm x 2500mm depth approx), SS-304 |
| 242 | Supply, installation, testing & commissioning of electronic type level indicator, instrumation and controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts. Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned component and additional component if so required for the complete working of the STP. |
| 243 | Supply, installation, testing & commissioning of non clogging typeMono block centrifugal sewage transfer pumps capableofhandlingsolidsupto 32 mm having C.I casing& Bronze impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automaticallyCapacity 3-5 M3/hr each ,1 set = 2 Nos.(1 working + 1 standby) Head 10-15 Mts Power1Hp RPM2900 Make- KIRLOSKAR/CG/LUBI/TEXMO |
| 244 | Supply, installation, testing & commissioning of non clogging type Mono-block centrifugal sludge transfer pumps capableofhandlingsolidsupto 25 mm having C.I casing& Bronze impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automaticallyCapacity 5 M3/hr each ,1 set = 2 Nos.(1 working + 1 standby) Head 10-15 Mts Power1 Hp RPM2900 Make- KIRLOSKAR/CG/LUBI/TEXMO |
| 245 | Twin lobetype rotary air blowers with 1450 rpm suitable motor(1W + 1Sb) capable of delivering65 Cum/hr ( 2 nos. ) of free air at 0.4 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable 3 HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. complete with silensors,filters ,NRV,SV and divert valaves,Vibration pads etc complete with all acessories 1set=2 Nos (1 working + 1 standby),Make-A1/EVEREST / AIRVAK/AKASHMotor Make SIEMENS/CROMPTON/KIRLOSKAR |
| 246 | Supplying, installing, testing and commissioning, of fine bubble diffuser along with membrane of silicone membranes,PVC support pipe(10 ksc pressure rating),PVC fitting, nylon rope braided hose with all accessories to make it retrievable & to provide clog-free oxygen for Aeration Tanks. |
| 247 | MBBR MediaModule as per std specification and detailed drawing and technical spec, quantity required as designed (approx 2.5-m3 each ) withsupport rest etc for the proposed MBBR directed by engineer in charge at siteMake-- COOLDECK/MM AQUA/WELCOME MARKETING |
| 248 | Hexagonal Tube settler with MSEP rack support and open able bracket/MH and support frame for clarifier unit of size 750 mm long and with end locking arrangement ,the inclination of 51’ is required ,end lock sud have the surface locking arrangement in rack etc (media min approx 10 m3) with all fittings and fixtures as required for clarifier as directed by engineer in charge at site.Make-- COOLDECK/MM AQUA/WELCOME MARKETING |
| 249 | Piping (heavy class) in MS/GI/SS/UPVC/HDPE as per the approval of the consultants, to be designed for suitable and corrosion resistance complete or as directed by engineer in charge at siteMS PIPE MAKE -JINDAL/TATAUPVC PIPE AND FITTINGS -- SUPREME/ASHIRBAD/FINOLEX |
| 250 | TERTIARY TREATMENT PLANT |
| 251 | Supplying, installing, testing and commissioning ofhorizontal single/multistage centrifugal filter feed pump complete ,impeller CI casing . Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. of capacity 5 M3/hr @ 35 MWC.(1 W + 1 St by ) MONO-BLOCK PUMP,1 set = 2 Nos.(1 working + 1 standby)Head 30-35 MtsPower1.5 HpRPM2900Make- KIRLOSKAR/CG/LUBI/TEXMO |
| 252 | Providing, fixing, testing& commissioning ofFRPTertiary filtrationplantMULTI GRADE FILTER(suitablefor3.5 Kg/Sqcm workingpressure)completewith initial charge with Gravels/pebbles/sand /silex media, Multiport valves with built in frontal pipe work with back washsystem, pressure gauge at inlet, outletandback wash (each with isolation cock), valves,fittings associatedworks. Pr Vessel MOC – FRP COMPOSITE VESSELPr Vessel dia/hos – 525 x 1550Back WashPeriod12Hrs.Operating Pressure 3 Kg. per sq.cmTest Pressure7.5 Kg. Sq.cm.Capacity 5 m3/HrMake- ION EXCHANGE/PENTAIR/AQUANOMICS |
| 253 | Providing, fixing, testing& commissioning ofFRPwaterfiltrationplantACTIVATED CARBON FILTER(suitablefor3.5 Kg/Sqcm workingpressure)completewith initial charge with Gravels/pebbles/Activated carbon, Multiport valves with built in frontal pipe work with back washsystem, pressure gauge at inlet, outletandback wash (each with isolation cock), valves,fittings associatedworks. Pr Vessel MOC – FRP COMPOSITE VESSELPr Vessel dia/hos – 525 x 1550Back WashPeriod12Hrs.Operating Pressure 3 Kg. per sq.cmTest Pressure7.5 Kg. Sq.cm.Capacity 5 m3/HrMake- ION EXCHANGE/PENTAIR/AQUANOMICS |
| 254 | Supply, installation, testing & commissioning of Hypochloridedosing system for tertiary water treatment with 100 L .HDPE/PVCtank with lidetc Capacity of the dosing Pump -0-4 LPHPressure- 4 Kg/cm2Stroke per minute-55Make- KANAKDHARA/MILTON ROY/E-DOSE |
| 255 | ELECTRICAL INSTALLATION FOR STPDesign, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables (in accordance to specification) with earthing from panel to each motor /STP Motor Control Centre. IncomingDistribution panel with bus bar etc as std required.MCC for GWTP as described above CABLE & CABLE TRAYS Supplying & laying offollowing 1100 voltgradePVC sheathed aluminum/copper conductor armoured cables as per specification in existing trenches, cable trays, ducts over bed of sand, clamped to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. as site suitable quantities as per site.4 core 4 sq. mm copper cable,8SWG Cupper wireMake- L&T/SIEMENS |
| 256 | A. COMPLETE COMMISSIONING OF SEWAGE TREATMENT PLANT WITH UREA, DAP, COW DUNG, BIO-CULTURE, MAN POWER ALONG-WITH TOOLS AND TACKLES FOR 20 DAYS.B. 1 YEAR MAINTAINANCE SERVICE AND REPLACEMENT WARRANTY(BUT EXCLUDES MAN-POWER,CONSUMABLES ,ELECTRICAL ETC)C. INLET AND OUTLET PARAMETERS TEST REPORT AFTER SUCCESFUL COMMISSIONING FROM POLLUTION BOARD APPROVED LABORATORY. |
| 257 | BORE WELL |
| 258 | Construction of 1 nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hamer drilling rig or combination rig with pvc pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the engineer in charge including use of own rig with its accessories ,tools and plant and consumables etc for lowering of 200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted with socket and with or without well screen as for the necessity for soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well) 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200/150mm dia bore 0.00 to 60.0 Mtr |
| 259 | Cleaning & developing the tube well with supply of compressor worked till clear & adequqte discharge is obtained from the tube well including supply & use of all necessary equipment & labour as per directin of the Engineer in charge By DTH Rig |
| 260 | Supplying all materials, equipments,labour & conducting reconnaissance survey , integrated Hydrological & Geophysical (Electrical resistivity Method) survey & selection of potential source for exploration of ground water including selection & recommendRocky terrain with boulder formation for 300m depth |
| 261 | Supplying all materials, labours, T&Pand providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge (Texmo/crompton Greaves/ Kirloskar make)2HP Single phase 3 stage vertical/Horizontal submersible pump set at head renge of 30 to 65 mtr with discharge capacity 155 to 110 L P.M with outlet dia 32mm |
| 262 | Supply, installation and commissioning of Control panel for submersible pump with provision of DOL starter, overload relay, ammeter, voltmeter, selector switch, indicator lamp etc. suitable for the pump complete as per direction of EIC. (Make- L&T, Havells, KSB, Simens) |
| 263 | Supplying fitting and fixing of 40mm dia tappered stainless steel nipple with stainless steel nut & bolt of approved quality including cost conveyanceas per direction of EIC. |
| 264 | Supplying and fitting of all materials, labour, T&P providing M.S well cover heavy duty with nut & bolt etc. complete as per direction of EIC. |
| 265 | Supplying and fitting of all materials, labour, T&P providing 50/40 mm size CI bracket etc. complete as per direction of EIC. |
| 266 | Supplying & lowering 3x2.5sqmm submersible flat copper cable of Finolex/ Havell’s/Polycab make from pump set to starter panel including all accessories, cost of all labour, all materials T&P etc. complete as per the direction of EIC. |
| 267 | Supplying and tying engineering rope of 8mm dia nylon of approved quality and size with the submersible pump and HDPE pipe including all cost as per direction of EIC. |
| 268 | Supplying all materials ,labour, T&P and providing and fixing to wall or celling and floor HDPE pipes and pipe fiting conforming to IS: 4984/2000(10KGF/SQCM) of the following nominal bore with clamps & joining by Fusion welding method including testing making good the wall celling & floor all complete as per specificaations 7 direction of the engineer in charge.32mm dia HDPE pipe |
| 269 | Supplying all materials, labour,T&P constructing Bore Well protection chamber of the size800x800x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation,1st class fly ash brick work in cement mortar (1:3) with base cement concrete (1:2:4) using 12mm sizeh hg chips,12mm thick cement plaster (1:4) inside and outside,RCC cover slab in (1:1.5:3)using 12mm size h g chops, earthwork in excavation in all kind of soil anf refilling the cavity around the chamber including watering, cunning, conveyance of all meterials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of Engineer in charge. |
| 270 | FIRE FIGHTING |
| 271 | Supply, erection, testing and commissioning of following sizes of heavy grade (\"C\" class) mild steel pipe, flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts\"Heavy class\" confirming to IS:1239-1974 Part - I and part - II with upto-date amendment i/c giving two coats of hot bituminous paint. Make- Tata/Zindal/Sail/Eq80mm dia |
| 272 | Supply, erection, testing and commissioning of following sizes of heavy grade (\"C\" class) mild steel pipe, flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts\"Heavy class\" confirming to IS:1239-1974 Part - I and part - II with upto-date amendment i/c giving two coats of hot bituminous paint. Make- Tata/Zindal/Sail/Eq25mm dia |
| 273 | Providing, fixing, testing & commissioning of Wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 30 Mtr. length x 20 mm dia heavy duty high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 6.5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe (heavy class) connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall by means of 120 mm x 100 mm long fasteners, bolts and nuts including painting.Make-KARTAR, Safex, Fireshield,Safe Guard |
| 274 | Providing and fixing brass/bronze lever operated ball valves of full flow with stainless steel ball (AISI 304 and spindle AISI 401) with settling and gland of superior quality and having minimum working pressure of 15 Kg/cm2.Make-Kartar/Zoloto/H Sarker/Eq. 25NB |
| 275 | Supply, installation, testing and commissioningof Fire Brigade inlet connection with provision for Four male instantaneous coupling fabricated out of 150 mm dia. approved make heavy class MS pipe with non-return valve, Butterfly valvefor fire fighting system including making connection by providing necessary piping & fittings to the fire storage tank, fire fighting wet riser, sprinkler system painting the same with 3 coats of enamel paint over a coat of Zinc Chromate primer all complete as per drawings, specifications. Make-Minimax, Safex, Fireshield,Kartar. a) Two way |
| 276 | TerraceSupplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomaticoperationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump) . a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 .b) SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-\"F\"insulation,conforming to IS-325. c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads. Make-wilo,kirloskar/lubi/equivalent 450 lpm at 35 m Head |
| 277 | Sitcof Terrace Pump ControllerSupplying,installation,testingandcommissioningof pump controller.Make-c&s/l&t/crompton/Eq |
| 278 | FIRE PUMPS & ANCILLARY WORKSProviding,installation,testingandcommissioningof cast ironY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdiaholes with stainless steel flange.Make-Kartar/Zoloto/H Sarker/Eq.80mm dia |
| 279 | Providing, fixing, testing & commissioning ofC.I. dual plated Non-return valve [PN 1.6 Rating (16kg/cm2] complete2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes .Make-Kartar/Zoloto/H Sarker/Eq.80 mm dia |
| 280 | Providing, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers complete . [PN -1.6 rating (16kg/cm2)]Make-Kartar/Zoloto/H Sarker/Eq.80NB |
| 281 | Supply,Providing & fixing Pressure Switchthe most commonly used fluid control components of Aluminum enclouser with storage temprature 40 to 180°F (-40 to 82°C) along with ambienttemprature 0 to 160°F (-18 to 71°C),set point shifts less than 1% of range for a 50°F (28°C) ambient temperature change. Unit will operate down to -40°F (-40°C) but with reduced repeatability. Maximum media temperature 200°F (93°C), Shock Set point repeats after 50 G, 10 millisecond duration. Switch output One SPDT including seven electrical terminations; Refer to \"How to Order\" and vibration set point repeats after 10 G, 5-500 CPS.Make-Honeywell/Danfoss/Jhonson controls. |
| 282 | Providing & fixing dial type (150 mm dia) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2.Make-H.guru/Emerald/Fiebig/Equivalent |
| 283 | Hand AppliancesNote :All the fire extinguishers shall be ISI marked and filling/validity date shall be painted. Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed towall with brackets complete with internal charge. Make-Minimax/Safex/Fireshield/ Safe Guard/Eq.Capacity 4.5 kg |
| 284 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed towall with brackets complete with internal charge. Make-Minimax/Safex/Fireshield/Safe Guard/EqCapacity 6 kg |
| 285 | SIGNAGESsupplying,fixing of following type 2 mm thick photo luminecent signages non toxic non radio active maintenance free self glowing safety signages comprising of supplied chargeable crystals to glow in the dark with high intesity luminous 1.2mm aluminium sheet properties by chemical coated ( Vinayal & Tap not accepted) and covered with UV Protection layer printed with graphics symbol etc as required. |
| 286 | For FIRE EXIT(12\"\" X 6\"\") |
| 287 | For FIRE HYDRANT(16\"\" X 6\"\") |
| 288 | For Stair case (12\"\"x6\"\") |
| 289 | Arrows symbol(12\"\"x6\"\") |
| 290 | Supplying all materials for providing Main School Signage over Entrance of School made out of GRFC letter of 2\" size along with OMC logo with approved colour code as decided by EIC and ArchitectProviding and fixing GFRC (Glass Fiber Reinforced Concrete) letter in the style \" ODISHA MINING ADARSHA VIDYALAYA\" IN English and Odia script where each letter shall have the avg height of 600/450mm and width of 65/50mm to be fixed on the top face of the entrance gate by using anchor fasteners such as hilty/fischer including cost of all materials, T&P, Scafoldings, royalty, taxes etc. complete.(b) Providing and fixing GFRC (Glass Fiber Reinforced Concrete) letter in the style OMC logo proposinate to the dishplay copy of logo avialable iat OMC web site to be fixed in vertical wall in between two gates by using anchor fasteners such as hilty/fischer including cost of all materials, T&P, Scafoldings, royalty, taxes etc. complete.(c) Painting the logo as well as signage letters with exterior acrlyc base texture paint over approved primer of approved brand and shade over finished surface including cost of all materials, T&P, Scafoldings, royalty, taxes etc. complete as directed by EIC. |
| 291 | Terrace Level Signage Cabinet: (1) MS Square Pipe 20 mm X 20 mm [18 guage] for framing with one coat of red oxide & 2 coats of oil paint to avoid rusting.(2) Powder coated 24 guage GI sheets on Top, Bottom & Sides. (3) Pre coated GI Sheet of 26 gauges for back cover.(4) Aluminium extruded L Angle system for flex tensioning & Edge lighting(5) The Depth of the box not to be greater than 6 inches.Illumination Source: (1) LED modules with IP67 rating with 3years warranty from the OEM. (2) LEDs with dust free and water proof compliance properties.(3) LEDs and Fascia to be optimized to offer best possible aesthetical output & energy saving.Fascia: (1) 22-mil, white pigmented vinyl substrate with a polyester scrim with 2mil translucent Matte surface finish thateliminates glare. The film shouldhave Synthetic, lay-flat liner that is not affected by water or humidity.(2) MCS online Warranty of 5 years from manufacturer of the vinyl and subtrate for Indian weatherand dust conditions without any restrictive sub clauses.Size:- 18\"\" letter height |
| 292 | Providing and fixing of Class room, departmental signage at entrance to various zones/departments5mm acryllic with Laser cutting along withduco finish, hanged/mounted fro ceiling with chain/screws and text as per approved colour and design scheme, of diff sizes as per requirements and as directed by EIC and Architect. |
| 293 | Internal Electrification |
| 294 | Supply and Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Average Length: 5 mtr |
| 295 | Supply and Recessed wiring to Twin control light pointwith 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Average Length: 5mtr |
| 296 | Supply and Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. Average Length: 3mtr |
| 297 | Supply and Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. |
| 298 | Supply and Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer in Charge. |
| 299 | Supply and Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. |
| 300 | Supply and Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer in Charge. |
| 301 | Supply and Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge. |
| 302 | Supply and PointwiringforProjector/ Geyser / A.C socket outlet with 16A plug socketand 16ADP control switch atnearest separate location including all accesories and connection as per direction of Engineer in Charge. |
| 303 | Supply and Recessed sub main wiring with 4 Nos. Single Core 16.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 Nos. Single Core 10.0 mm2 FRLS Copper Wire for Earth Continuity Conductor inside a 1.6mm thick 50 mm dia Non-metalic PVC conduit pipe complete with making good the damages caused as required and including all accessories and connectionas perDirection of Engineer-In-charge. |
| 304 | Supply and Recessed sub main wiring with 4 Nos. Single Core 10.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 Nos. Single Core 6.0 mm2 FRLS Copper Wire for Earth Continuity Conductor inside a 1.6mm thick 40 mm dia Non-metalic PVC conduit pipe complete with making good the damages caused as required and including all accessories and connectionas perDirection of Engineer-In-charge. |
| 305 | Supply and Recessed sub main wiring with 4 Nos. Single Core 6.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Earth Continuity Conductor inside a 1.6mm thick 32 mm dia Non-metalic PVC conduit pipe complete with making good the damages caused as required and including all accessories and connectionas perDirection of Engineer-In-charge. |
| 306 | Supply and Recessed sub main wiring with 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor inside a 1.6mm thick 32 mm dia Non-metalic PVC conduit pipe complete with making good the damages caused as required and including all accessories and connectionas perDirection of Engineer-In-charge. |
| 307 | Supply and Recessed sub main wiring with 2 Nos. Single Core 2.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor inside a 1.6mm thick 20 mm dia Non-metalic PVC conduit pipe complete with making good the damages caused as required and including all accessories and connectionas perDirection of Engineer-In-charge. |
| 308 | Supply and Recessed sub main wiring with 2 Nos. Single Core 1.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor inside a 1.6mm thick 20 mm dia Non-metalic PVC conduit pipe complete with making good the damages caused as required and including all accessories and connectionas perDirection of Engineer-In-charge. |
| 309 | Supply, delivery, installation and testingof 4-Way (8+12) MCB DB with glazed door (IP-43) complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required and as perDirection of Engineer-In-Charge. ( But with out MCB/ RCCB/ Isolator) |
| 310 | Supply, delivery, installation and testingof 6-Way (8+18) MCB DB with glazed door (IP-43) complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required and as perDirection of Engineer-In-Charge. ( But with out MCB/ RCCB/ Isolator) |
| 311 | Supply, delivery, installation and testingof 8-Way (8+24) MCB DB with glazed door (IP-43) complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required and as perDirection of Engineer-In-Charge. ( But with out MCB/ RCCB/ Isolator) |
| 312 | Supply and fixing of 6-32Amp rating 240 V C-Series Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as perDirection of Engineer-In-Charge. |
| 313 | Supply and fixing of 40Amp rating 415 V 4P Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as perDirection of Engineer-In-Charge. |
| 314 | Supply and fixing of 32Amp rating 415 V 4P Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as perDirection of Engineer-In-Charge. |
| 315 | Supply and fixing of 25Amp rating 415 V 4P Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as perDirection of Engineer-In-Charge. |
| 316 | Supply and fixing of 63Amp rating 415 V 4P Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as perDirection of Engineer-In-Charge. |
| 317 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 100Amp METER PANEL For Staff Quarter with 100A 4P MCCB (36kA) - 1 No. as incoming,63A 4P MCB (C-Curve) - 6 Nos. followed by 5-30Amp 3P Energy Meter-6 Nos, 32Amp (C-Curve) 2P MCB-3 Nos. followed by 5-30Amp 1P Energy Meter-1 No. as Outgoing and 3 Nos 160/5A CT, Multifunction Meter and 160A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 318 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 160Amp PANEL For Boys Hostel & Girls Hostel with 160A 4P MCCB (36kA) - 1 No. as incoming, 40A 4P MCB (C-Curve)- 13 Nos, 32A 4P MCB (C-Curve)- 13 Nos, 32A 2P MCB(C-Curve)- 3 Nos. as Outgoing and 3 Nos 200/5A CT, Multifunction Meter and 200A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 319 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 100Amp PANEL For Dining Block with 100A 4P MCCB (36kA) - 1 No. as incoming,63A 4P MCB (C-Curve) - 2 Nos., 32A 4P MCB (C-Curve) - 2 Nos., 32Amp (C-Curve) 2P MCB-3 Nos. as Outgoing and 3 Nos 100/5A CT, Multifunction Meter and 100A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 320 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 50 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 630Amp Main PANEL For School Block with 630A 4P MCCB (50kA) - 1 No. as incoming,250A 4P MCCB (36kA) - 3 Nos., 160A 4P MCCB (36kA) - 2 Nos., 100A 4P MCCB (36kA) - 2 Nos., 32A 2P MCB(C-Curve)- 6 Nos. as Outgoing and 3 Nos 600/5A CT, Multifunction Meter and 800A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 321 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 50 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 250Amp Floor PANEL For Ground & First Floor of School Block with 250A 4P MCCB (36kA) - 1 No. as incoming, 63A 4P MCB(C-Curve)- 6 Nos., 32A 4P MCB(C-Curve)- 6 Nos., 32A 2P MCB(C-Curve)- 3 Nos. as Outgoing and 3 Nos 250/5A CT, Multifunction Meter and 250A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 322 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 160Amp Foor PANEL For Second Floor of School Block with 160A 4P MCCB (36kA) - 1 No. as incoming, 63A 4P MCB (C-Curve)- 6 Nos, 32A 4P MCB (C-Curve)- 6 Nos, 32A 2P MCB(C-Curve)- 3 Nos. as Outgoing and 3 Nos 200/5A CT, Multifunction Meter and 200A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 323 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: 100Amp Foor PANEL For Multipurpose Hall with 100A 4P MCCB (36kA) - 1 No. as incoming, 63A 4P MCB (C-Curve)- 3 Nos, 40A 4P MCB (C-Curve)- 3 Nos, 32A 2P MCB(C-Curve)- 3 Nos. as Outgoing and 3 Nos 100/5A CT, Multifunction Meter and 100A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 324 | Supply and installation of Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required as per direction of EIC. |
| 325 | Supply and fixing of sufficient amount of salt and charcoal for G.I. plate earthing to achieve the earth value below 3 Ohm as required as per direction of EIC. |
| 326 | Supply and laying of 50 mm x 6 mm G.I earth strip of ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required as per direction of EIC. |
| 327 | Supply and laying of 25 mm x 5 mm G.I earth strip of ISI marked on surface or in recess for connection etc as required as per direction of EIC. |
| 328 | Providing and fixing of 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required as per direction of EIC. |
| 329 | Providing and fixing of lightning conductor finial made of 25mm dia 500 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete asrequired as per direction of EIC. |
| 330 | Providing and fixing of G.I. tape of 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required as per direction of EIC. (For Horizontal run) |
| 331 | Providing and fixing of G.I. tape of 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required as per direction of EIC. (For Vertical run) |
| 332 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125mm long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required as per direction of EIC. |
| 333 | Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required as per Direction of EIC. |
| 334 | Providing and laying of G.I. tape of 32 mm x 6 mm from earth electrode directly in ground as required as per direction of EIC. |
| 335 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 18W SINGLE LED TUBELuminaire with all accessories and lamp etc. directly on ceiling /wall , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 336 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 36W 2\"X2\" Square Clean room LEDLuminaire with all accessories and lamp etc. directly on ceiling including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 337 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 24W 1\"X1\" Square Clean room LEDLuminaire with all accessories and lamp etc. directly on ceiling including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 338 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 15W Round LEDLuminaire with all accessories and lamp etc. directly on ceiling including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 339 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 12W Round LEDLuminaire with all accessories and lamp etc. directly on ceiling including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 340 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 10W Bulk head LEDLuminaire with all accessories and lamp etc. directly on surface including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 341 | Supply, Installation, Testing and Commissioning of Surface mounted indoor type 10W Mirror LEDLuminaire with all accessories and lamp etc. directly on wall including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 342 | Supply, Installation, Testing and Commissioning of 240V, 1200mm sweep, BEE 5 Star rated Ceiling fan with Brush Less Direct Current (BLDC) motorincluding connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and down rod of standard length (Upto 30cm) as required as per direction of EIC. |
| 343 | Supply, Installation, Testing and Commissioning of 240V, 900mm sweep Star rated Ceiling fan including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and down rod of standard length (Upto 30cm) as required as per direction of EIC. |
| 344 | Supply, Installation, Testing and Commissioning of 240V, 300mm sweep, 900 rpm Exhaust fan in the existing opening including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and making the hole to suit the size of the fan, making good to the damage etc as required as per direction of EIC. |
| 345 | Supply, Installation, Testing and Commissioning of 240V Ding-dong type Call bell with ISI mark with all accessories and lamp etc. directly on wall including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required as per direction of EIC. |
| 346 | Data Networking System |
| 347 | Supply and laying of 4 pair Cat-6 U/UTP Cablein the existing surface/ recessed steel/ PVC conduit as required for Data & Voice: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance = 9.38 O/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 O @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant etc as required as per direction of EIC. |
| 348 | Supply and Installation of Cat-6 I/O with Dual Face plate: The Outlet shall meet or exceed requirementas per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173.The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 µm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified etc as required as per direction of EIC. |
| 349 | Supply and installation of Cat-6, 24-portloaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking etc as required as per direction of EIC. |
| 350 | Supply and installation of Cat-6 UTP 24 AWG Patch Cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to theStandard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion ,RJ45, 8P8C, 2 FORK 50µ’’ Gold Plated Contacts ,100% Factory Tested ,Transparent Boot Cable Assemblies etc as required as per direction of EIC. (1 Mtr Long) |
| 351 | Supply and installation of Cat-6 UTP 24 AWG Patch Cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to theStandard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion ,RJ45, 8P8C, 2 FORK 50µ’’ Gold Plated Contacts ,100% Factory Tested ,Transparent Boot Cable Assemblies etc as required as per direction of EIC. (2 Mtr Long) |
| 352 | Supply and laying of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit:The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm.Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 /ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae )Jacket etc as required as per direction of EIC. |
| 353 | Supply and Installation of 42U Floor MountServer Rack with Accessories: Size - 800 Width x 1000 Depth, Construction-Modular Constuction of the rack made of 4 vertical , 4 horizontal& 4 depthaluminum alloy extruded multifolded hollow profiles bolted and joined together with Links and Corner Block. 3 pairs of support channel to equate the load evenly and castor provision at bottom side, front and rear door of sheet steel, with foamed-in seal, special honeycomb punching pattern Single point and multi point locking rod, Floor Standing Panel on 3 Inch Height castors with brake, Accessories-1no Sheet steel, duly powder coated texture finish -700D, Power Distribution Unit - 06/16 Amp Indian-Standard - 12 Socket - Single Pole / Screw Mountable / 32 Amp MCB / Alternating Current -Industrial Plug 32A with Power Cable 6 sq.mm 3 meter Length, 1no Metal cable manager with PVC cable loops, 4nos cooling Fan(230V AC - 90 CFM, dB 42), H/W Screw Packet(20sets), Painting Shade-RAL 7035/7037 Fine Texture– 60 to 80uM. RAL 7037 for Frame structure and RAL 7035 for other parts, Corrosion Resistance-Salt spray test according to ISO 9227 (NSS test) and IEC EN 60068-2-11 (Ka test) for 168 hours: degree of Rusting Ri1 according to ISO 4628-3, propagation =1 mm according to ISO 4628-8, Compliance with standards-UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 etc as required as per direction of EIC. |
| 354 | Supply and fixing of 32mm dia PVC conduit along with accessories in recessed including cutting the wall and making good the same as required for CCTV and others for future. |
| 355 | Air Conditioning & Exhaust System |
| 356 | Supplying,Installation,Testing & commissioning of 1.0 Ton, single phase,5 star rating Inverter Split AC with copper condensoron the existing wall and making duct on the same for connecting to outdoor unit and water drainage system with 4KVA, 90-300V autometic voltage stabilizer, Placing the outdoor unit outside the wall with non rusting bracket to be fixed on the outer wall etc. as required and as per direction of EIC. |
| 357 | Supplying,Installation,Testing & commissioning of 2.0 Ton, single phase,5 star rating Inverter Split AC with copper condensoron the existing wall and making duct on the same for connecting to outdoor unit and water drainage system with 6KVA, 90-300V autometic voltage stabilizer, Placing the outdoor unit outside the wall with non rusting bracket to be fixed on the outer wall etc. as required and as per direction of EIC. |
| 358 | Providing and fixing of 25mm dia, 9mm thick PVC pipe with bending arrangement for collection and drainage of AC outlet water etc. as required and as per direction of EIC. |
| 359 | Providing and fixing of 32mm dia, 9mm thick PVC pipe with bending arrangement for collection and drainage of AC outlet water etc. as required and as per direction of EIC. |
| 360 | Supply installation, testing , commissioning of SISW Backward curved centrifugal fans of 1000CFM @ 25mm static pressure (Bearing, motor and shaft shuould be outside of airflow path).Consistng of motor , drive arrangement, MS channel common base frame for fan. Fan should be AMCA certified for AIR, SOUND and FEG( minimum FEG should be 80). Outlet velocity of the fan should not exceed 11 m/s. Shound level of the fan should not exceed 75db(A) @ 3 meter distance. Installed motor KW. should be 30% higher than fan brake KW etc. as required and as per direction of EIC. |
| 361 | Supply,installation, testing and commissioning of Propeller fan of 600CFM for Toilet exhaust etc. complete asrequiredand as per Direction of EIC. |
| 362 | Supply, installation, balancing and commissioning of Site fabricated Gi sheet metal of 24 Gauge (Thickness 0.63mm)rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per site condition as required and as per direction of EIC. |
| 363 | Supply, Installation, testing and balancing of powder coated Alluminium Grilles with Aluminum volume control damper complete withnuts, bolts, screws etc. as per site condition as required and as per direction of EIC. |
| 364 | Supply and fixing of exhaust air louvers with section comprising of powder coated Aluminium louvers & bird screen complete withnuts, bolts, screws etc. as per site condition as required and as per direction of EIC. |
| 365 | Supply & laying of PVC Sheathed, XLPE insulated Aluminum conductor armoured cable of 4Cx2.5 Sq mm, 1.1kV grade etc. complete asrequiredand as per Direction of EIC. |
| 366 | Supply, Installation, testing & commisioning of 3 KW 3 phase DOL starer with D-range Contactor & LR1D OLR in 2mm CRCA steel sheet duly painted having 1 no 32A 4P MCB, 1 no 3P power contactor, 1 no 9 to 15A PLR, 1 no 30A CT operated ameter, 3 nos. phase indication lamp, 3 nos. ON,OFF,TRIP indicator, 2 nos. ON/OFF push button, 1 no. emergency stop with provision for remote operation for ventilation fanas required and as per direction of EIC. |
| 367 | External Electrification |
| 368 | Supply, Installation, Testing and Commissioning of 13 Mtr long 160X152 mm WPB pole (30.44Kg/Mtr) including earth excavation work, concreting of pole (2.17Mtr X 0.5 Mtr X 0.5 Mtr=0.55Cum) with PCC (1:1.5:3) with couping of support (0.45Mtr X 0.5 Mtr X 0.5 Mtr=0.1125Cum) with PCC (1:1.5:3) , all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 369 | Supply, Installation, Testing and Commissioning of4.3 Mtr long straight cross arm of size 75X40X4.8 mm (7.14 Kg/Mtr) for Metering Unit Channel including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Meter DP and Sub-Station DP) |
| 370 | Supply, Installation, Testing and Commissioningof4.3 Mtr long straight cross arm of size 100X50X6 mm (9.56 Kg/Mtr) for Top Channel including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Meter DP and Sub-Station DP) |
| 371 | Supply, Installation, Testing and Commissioning of 0.280 Mtr long Fish Plate of size 50X6 mm (2.36 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 372 | Supply, Installation, Testing and Commissioning of4.3 Mtr long Isolator Support Channel of size 75X40X4.8 mm (7.14 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Meter DP and Sub-Station DP) |
| 373 | Supply, Installation, Testing and Commissioning of4.3 Mtr long HG Fuse Support Channel of size 75X40X4.8 mm (7.14 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge .(Required for Sub-Station DP) |
| 374 | Supply, Installation, Testing and Commissioning of1.0 Mtr long HG Fuse Extension Channel of size 75X40X4.8 mm (7.14 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Sub-Station DP) |
| 375 | Supply, Installation, Testing and Commissioning of1.5 Mtr long HG Fuse Cantilever Angle of size 50X50X6 mm (4.5 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Sub-Station DP) |
| 376 | Supply, Installation, Testing and Commissioning of4.3 Mtr long Double Pole Belting Channel of size 75X40X4.8 mm (7.14 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Metering DP & Sub-Station DP) |
| 377 | Supply, Installation, Testing and Commissioning of5.0 Mtr long Bracing Angle of size 50X50X6 mm (4.5 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Metering DP & Sub-Station DP) |
| 378 | Supply, Installation, Testing and Commissioning of0.8 Mtr long Isolator Operating Down pipe Support Channel of size 75X40X4.8 mm (7.14 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Metering DP & Sub-Station DP) |
| 379 | Supply, Installation, Testing and Commissioning of0.388 Mtr long Down pipe Diagonal Support Angle of size 50X50X6 mm (4.5 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Metering DP & Sub-Station DP) |
| 380 | Supply, Installation, Testing and Commissioning of0.34 Mtr long Down pipe Base Support Angle of size 50X50X6 mm (4.5 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Metering DP & Sub-Station DP) |
| 381 | Supply, Installation, Testing and Commissioning of0.5 Mtr long Isolator Support Side Channel of size 100X50X6 mm (9.56 Kg/Mtr) for Top Channel including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Meter DP and Sub-Station DP) |
| 382 | Supply, Installation, Testing and Commissioning of33kV, 200Amp, 3-Pole, 50Hz, Horaizontal type AB Switch set including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Meter DP and Sub-Station DP) |
| 383 | Supply, Installation, Testing and Commissioning of33kV, 200Amp, 3-Pole, 50Hz, HG Fuse set including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Meter DP and Sub-Station DP) |
| 384 | Supply, Installation, Testing and Commissioning of3.25 Mtr long straight cross arm of size 100X50X6 mm (9.56 Kg/Mtr) for Top Channel including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Line & Cut-point DP) |
| 385 | Supply, Installation, Testing and Commissioning of1.96 Mtr long Double Pole Belting Channel of size 75X40X4.8 mm (7.14 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Line & Cut-point DP) |
| 386 | Supply, Installation, Testing and Commissioning of3.5 Mtr long Bracing Angle of size 50X50X6 mm (4.5 Kg/Mtr) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . (Required for Line & Cut-point DP) |
| 387 | Supply, Installation, Testing and Commissioning of 33kV Danger Plate of required size as per IS standard (In Odia & English Language) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 388 | Supply, Installation, Testing and Commissioning of Back Clamp for Danger Plate of 0.510 Mtr long made up of 25x3 mm GI flat (0.59Kg/Mtr)including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 389 | Supply, Installation, Testing and Commissioning of GI Barbed wire for Anticlimbing Device (3Kg per Support)including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 390 | Supply, Installation, Testing and Commissioning of Back Clamp for Anti-Climbing Device of 0.510 Mtr long made up of 25x3 mm GI flat (0.59Kg/Mtr)including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 391 | Supply, Installation, Testing and Commissioning of 33kV Pin Insulator (Polymer type) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 392 | Supply, Installation, Testing and Commissioning of Hardware Fitting (B&S) 90kN, 4 bolt with 33kV Disc Insulator (B&S) 90kN, Polymer type including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 393 | Supply, Installation, Testing and Commissioning of PG Clamp for 100 Sq mm AAA Conductor including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 394 | Supply and Laying of 100 Sq mm AAA Conductor including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 395 | Supply, Installation, Testing and Commissioning of HT stay set in complete including earth excavation work, concreting of stay set (1.65Mtr X 0.3 Mtr X 0.3 Mtr= 0.1485Cum) in PCC (1:2:4) all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 396 | Supply, Installation, Testing and Commissioning of 25X3mm GI Flat (0.6 Kg/Mtr) for earthing of LA, AB Switch, HG Fuse, Metering Unit, Transformer Body etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 397 | Supply, Installation, Testing and Commissioning of 50X6 mm GI Flat (2.4 Kg/Mtr) for Transformer Neutral earthing connectivity etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 398 | Supply, Installation, Testing and Commissioning of 30kV, 10kA, Station Class, Class-2 Lightning Arrester etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 399 | Supply and fixing of chemical Earthing of with 3mtr long40mm dia chemical filled comound and GI earth electrodeincluding excavation of earth pit with highly conductive back filled chemical compund of 2 x25kg , brick work in cement mortar masonary workwith removable cover for Earth pit chamber ofsuitable size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 400 | Supply, Installation, Testing and Commissioning of 500kVA, 33/0.415kV, Copper wound, ONAN, Outdoor type Transformer (Minimum 2-Star), BIS Energy Level-II with Oil Temperature and Winding Temperature Indicator, Buchholtz relay, Explosion Vent, Oil Conservator tank with Breather, 5 step Tap Changer, LT terminal connection Chamber etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 401 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle outdoor panel totally enclosed, dust and vermin proof with IP-66 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 36 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: SUB-STATION LT SWITCHING PANEL with 630A 4P MCCB (36kA) - 1 No as incoming and Outgoing. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
| 402 | Supply and Painting of Red oxide paint including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 403 | Supply and Painting of Aluminum paint including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 404 | Supply and Painting of Black paint including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 405 | Sundries for survey ,tree cutting, small size nut & bolt with washer , AluminumBinding Tape, Danger Board etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 406 | Supply and fixing of GI Nut, Bolt and washer of different sizes as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge . |
| 407 | Civil Work for Transformer Plinth and Sub-station |
| 408 | Earthwork in excavationby cutting in foundation trenches for columns, basement, tie beams, walls and steps in disintegrated rock not requiring blasting to be removed by pick axes and crow bars with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In Hard soil Upto 1.5m depth. |
| 409 | Filling foundation and plinth with river sand, well watered, rammed including cost, conveyance, royalties of materials, cost of all labour and T&P required for the work etc. complete as per direction of EIC. |
| 410 | C.C of prop. (1:4:8) in foundation using 40mm. Size broken hard granite metal of approved quality from approved quarry including lowering,laying concrete to required levels laid in layers not exceeding 150mm thick including cost,conveyance,royalities of all materials,cost of all labour,T & P required for the work etc.required to complete as per direction of EIC. |
| 411 | P.C.C. of prop. (1:2:4) in allfloors using 20mm size hard crusher broken granite chips of appd. Quality from appd. quarry including centering, shuttering to wall side & lowering, laying, concrete, watering and curing etc. comp. to required levels laid in layers not exceeding 150mm thick including cost, conveyance, royalties of all materials and cost of all labour, T&P required for the work etc. complete as per direction of EIC |
| 412 | Fly ash brick masonry in C.M.(1:6) after immersing the bricks having minimum crushing strength of 75 Kg/Cm2 in water for 24 hours having size of 25cmx12cmx8cm in foundation & plinthwith ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC. |
| 413 | R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. |
| 414 | Supplying HYSDbars of appd. Quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC workincluding cost, conveyance of HYSD bars (Fe500) and binding wires of 18 to 20 gauge and cost of labour, T&P required to comp. in all respectas directed by the EIC. |
| 415 | 12mm (1/2\") thick cement plaster (1:6) for finished smooth to inside masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. |
| 416 | Supply, fitting & fixing of MS angle of size 65X65X6 mm thick including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 417 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. - Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade TATAWIRON |
| 418 | Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete |
| 419 | Supplying, stacking and Spreading of 40mm size CHBG metal including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 420 | Sub-station |
| 421 | Supplyof3.5 C x 300 sq.mm aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 422 | Supplyof3.5 C x 120 sq.mm aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 423 | Supply of3.5 C x50sq.mmsq.mm aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 424 | Supply of3.5 C x 25 sq.mm sq.mm aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 425 | Supply of 4.0 C x 16 sq.mm sq.mm aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 426 | Laying ofXLPE power cable of 1.1 KV grade of size not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 427 | Laying of XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 428 | Laying of XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 429 | Laying ofXLPE power cable of 1.1 KV grade ofsize exceeding 25 sq.mm but not exceeding 400 sq.mm in the RCC HUME pipe (NP-4) of dia 200mm as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 430 | Laying and fixing of XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 431 | Laying and fixing of XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 432 | Laying and fixingXLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 433 | Supply and making end termination with brass compression gland and aluminum lugs for 3.5 C x 300 sq.mmXLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 434 | Supply and making end termination with brass compression gland and aluminum lugs for 3.5 C x 120 sq.mmXLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 435 | Supply and making end termination with brass compression gland and aluminum lugs for 3.5 C x50sq.mmXLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 436 | Supply and making end termination with brass compression gland and aluminum lugs for 3.5 C x 25 sq.mmXLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 437 | Supply and making end termination with brass compression gland and aluminum lugs for 4.0 C x 16 sq.mmXLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 438 | Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle outdoor panel totally enclosed, dust and vermin proof with IP-66 protection with hinged and lockable doors. CRCA sheets (16 SWG)including Busbars,interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 36 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: EXTERNAL LIGHT PANEL with 100A 4P MCB- 1 No as incomer,40A 4P MCB- 6 Nos, 32A 4P MCB- 6 Nos, 32A 2P MCB-9 Nosas Outgoing. |
| 439 | Supply & fixing of 7 mtr hight internally and externallyhot dipped galvanised octagonal pole, continously tapered (bolt fixing type) in single section made of 3mm thick HT steel sheet conforming to IS 4759:1996/IS 2629:1985,suitable for bracket having top dia 70-75mm and bottom dia 130-150 mm, base plate size 220mmX220mmX12mm to 240mmX240mmX16 mm with door and locking arrangement (1 Mtr from Bottom) complete withall accessories as per GA Drawing attached in the SBD. Bracket of Single-arm of ERW galvanised pipe 30mm dia - 1M length, bakelite sheet,neutral link, suitable MCB or any other electrical accessory,suitable foundation bolts of diameter 20 to 22 mm,700mm apprx length, \"J\" type and civil foundation soil excavation of (1.2x0.5x0.5) mtr,concreating grade 1:3:6 ,RCC 0.281 Cum & PCC 0.01875 Cum and required sand filling as per foundation Drawing attached in the SBD with all accesories as directed by EIC. |
| 440 | Supply & fixing of 7 mtr hight internally and externallyhot dipped galvanised octagonal pole, continously tapered (bolt fixing type) in single section made of 3mm thick HT steel sheet conforming to IS 4759:1996/IS 2629:1985,suitable for bracket having top dia 70-75mm and bottom dia 130-150 mm, base plate size 220mmX220mmX12mm to 240mmX240mmX16 mm with door and locking arrangement (1 Mtr from Bottom) complete withall accessories as per GA Drawing attached in the SBD. Bracket of Double-arm of ERW galvanised pipe 30mm dia - 1M length, bakelite sheet,neutral link, suitable MCB or any other electrical accessory,suitable foundation bolts of diameter 20 to 22 mm,700mm apprx length, \"J\" type and civil foundation soil excavation of (1.2x0.5x0.5) mtr,concreating grade 1:3:6 ,RCC 0.281 Cum & PCC 0.01875 Cum and required sand filling as per foundation Drawing attached in the SBD with all accesories as directed by EIC. |
| 441 | Supply and fixing of Coil type earthing made up of 6 SWG GI wire of 2.5 mtr long including all accessores as per direction of EIC. |
| 442 | Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 70W/72W LED Lampincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 443 | Supply and Laying of one number of PVC insulated, PVC seathed / XLPE insulated armoured power cable of 1.1 KV grade of 4Cx 10 sq.mm Al. in ground through 50mm dia medium duty HDPE pipe including excavation , sand cushining and refilling the trench etc. as requiredincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 444 | Supply and Laying of one number of PVC insulated and PVC seathed / XLPE insulated armoured power cable of 1.1 KV grade of 2Cx 6 sq.mm Al.direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required. |
| 445 | Supply and Laying of 3.0core 1.5 sq mm PVC Insulated Copper flexible cable inside the existing Street light pole including all accessories ,materials as required as per the direction of EIC. |
| 446 | Supplying and making end termination with brass compression gland and aluminum lugs for 4C x 10 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories ,materials as required as per the direction of EIC. |
| 447 | Supplying and making end termination with brass compression gland and aluminum lugs for 2C x 6 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories ,materials as required as per the direction of EIC. |
| 448 | Supplying and Laying ofof 50mm G.I pipe(Medium Class) along with accessories ingroundincluding cutting & making good the sameas required for road crossing including all accessories ,materials as required as per the direction of EIC. |
| 449 | Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate including all accessories ,materials as required as per the direction of EIC. |
| 450 | Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate including all accessories ,materials as required as per the direction of EIC. |
| 451 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room including all accessories ,materials as required as per the direction of EIC. |
| 452 | Supply and handing over 11KV Tested Rubber hand gloves to be used on LT supply with Test certificate including all accessories ,materials as required as per the direction of EIC. |
| 453 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room including all accessories ,materials as required as per the direction of EIC. |
| 454 | Supply and fixing of 250x200 mm Danger plate including all accessories, materials as required as per the direction of EIC. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail