| 1 | Supplying and pasting tarfelt sheets of reputed manufacture one layer over A.C sheet expansion joints, ridges etc after cleaning the surface and applying roofing compound etc complete. (the rate shall include cost of tarfelt ,roofing compound labour charges scaffolding etc complete. The work is to be carried out at roof of godown at a height up to 12Mtrs from ground level after observing all safety norms). |
| 2 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet . |
| 3 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 4 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system underapproximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5\" or 4.2\" or 6\") or step-down (2\" or 3\" or 6\" ) as specified |
| 5 | Cleaning masonary drains of width 25cm to 60 cm and depth upto 60cm including removal of silt and rubbish with in a distance of 150m and removing the grass and vegetation from the side of drains three times (once in every three months) as directed by the Engineer- in- Charge |
| 6 | Cleaning masonry drains of width 60 cm to 80 cm. and depth upto 100 cmIncluding removal of silt and rubbish within a distance of 150m. and removing the grass and vegitation from the side of drains thrice (once in every three months) as directed by engineer in charge . |
| 7 | Taking out RCC slab from drains carefully without any damages and keeping in the same position after cleaning the drains thrice (once in every three months) as directed. (charges for cleaning the drains will be paid seperately) |
| 8 | Repairs / servicing rolling shutters such as tigtening or loosening the springs adjusting the dislocation of top cover and applying grease to springs side guides (1/2 kg yellow cup grease per shutter) after cleaning the surface complete as directed by the Engineer-in-charge . |
| 9 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 10 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 11 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (10.16.1) Hot finished welded type tubes |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 14 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire |
| 15 | Cleaning septic tank and inspection chamber including removing cover slab , taking away the sediments , soil , sludge etc from the tank and burrying it into an average pit of suitable size and spreading lime even it , refilling the pit , cleaning sewer line of water closet , refilling the tank with water etc and refixing the cover slab complete as directed by the engineer-in-charge . |
| 16 | Providing mild steel weld mesh with MS flat or L angle frame as required, firmly anchoring them to concrete or wooden surface for openings such as windows/ ventillators/ corridor etc. including applying priming coat as directed by the Engineer-in-charge |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 18 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 19 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 21 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 22 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick |
| 23 | Providing and fixing the angleiron fenders of size 100X 100X6mm to the godown varandha nosing, straightening the angle iron to suite the existing nosing tip impression, providing 30 cm long ,16 mm dia bolts by drilling the varandha concrete to a depth of 10 cm and welding ms pieces with existing reinforcement, concreting the dips ,compacting , fixing and finishing bolts,nuts, fenders etc complete as directed by the engineer in charge |
| 24 | Providing and fixing Aluminum wardrobes(Height 80cm xwidth70cm minimum )made of Aluminum frames top with multy woodsides and door with hylam sheet |
| 25 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 27 | Applying waterproofing to concrete roof surfaces using acrylic based waterproofing compounds such as tapecrete or any approved make including preparation of surface by cleaning all dust/ deposits, and applying the mixture in the ratio of 100 kg. cement : 50 kg of TAPECRETE. (The mix has to be prepared without any air bubbles.), two or more coats recommended, including curing the coating, complete as directed by the Engineer-in-charge. |
| 28 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete |
| 29 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 30 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below |
| 31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 34 | Providing and fixing radial exhaust turbo ventillators/extractor capacity of minimum 100cuft per minute air circulated fan of 22\" throat dia weight of 5.5kg having throat dia wind ventillator with FRP base plate, including cost of fixing turbo/wind ventillator on new 0.50mm thick pre-coated GI profile sheet roofing on godown roof lincluding the cost of transportation of all materials tools and plants, fixtures & fastenings. Labour, insurance, safety measures etc and as directed by the Engineer in charge including guarantee of turbo ventillators of minimum 03 years and performance warranty etc complete. |
| 35 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 37 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Cold twisted bars |
| 38 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 39 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |