| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 2 | M&L Point wiring forOne light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including PVC concealed rigidconduit heavy duty (ISI mark) and pressed steel terminal boxes (for mounting switches / sockets/regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm and 6cm depth including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed.Note :- (i)The wiring shall be provided in standard colour code i.e. Red for Phase, Black for Neural and Green for earth.(ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces.(iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed.(iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed. |
| 3 | All as per item No. 2.00above butfor One 3-pin socket outlet 5 Amp on independent board. |
| 4 | All as per item no 2.00 above but one 3 pin socket outlet 5 Amp on same board |
| 5 | All as per item no 2.00 above but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board.with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed. |
| 6 | All as per item no 2.00 above but for One industrial power socket 20 Amp on independent boardwith 4 sqmm FRLS multistranded copper cable including 4 sqmm FRLS multistranded copper cable as earth continuity wire in existing conduit connected to common earth and each terminal box/fitting complete all as specified and directed. |
| 7 | All as per item no 2.00 above butin existing PVC Conduit. |
| 8 | All as per item no 2.00 above butfor One 3-pin socket outlet 5 Amp on independent board in existing PVC Conduit. |
| 9 | All as per item no 2.00 above but one 3 pin socket outlet 5 Amp on same board in existing PVC Conduit. |
| 10 | Taking out carefully the existing burnt sub main wiring of size 4 Sqm / 6 Sqmm PVC insulated multi stranded aluminium conductor cable along-with earth continuity conductor from the PVC / rigid steel, concealed/surface conduitcomplete all as specified and directed. |
| 11 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including non metallic PVC conduit 20mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of cable and one run of PVC conduit shall be considered as one unit for measurement purposes. |
| 12 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 2.5 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including non-metallicconduit 20mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of 01 metre cable and 01 run of PVC conduit shall be considered as one unit for measurement purposes. |
| 13 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including pvc non-metallicconduit 25mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of 01 metre cable and 01 run of PVC conduit shall be considered as one unit for measurement purposes. |
| 14 | Supply and laying sub main wiring complete with 05 runs ( 3 nos for three phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including PVC non-metallicconduit 25mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 05 runs of cable 01 metre 01 run of PVC conduit shall be considered as one unit for measurement purposes. |
| 15 | supply and fix as in repairs MCB DB single pole and neutral 240 volt SPN 04 way with 200 Amps rated bus bardouble door type complete all as specified and directed. |
| 16 | All as per item No. 15.00above but8 way. |
| 17 | All as per item No. 15.00above but12 way. |
| 18 | Supply and fix as in repairs MCB SPN 10-32 Amps 240Volts, Breaking capacity 10 KA \"C\" curve complete all as specified and directed. |
| 19 | Supply and fix as in repairs ELCB SPN 40 Amps 240Volts,complete all as specified and directed. |
| 20 | Supply and fix as in repairs MCB SP 6-32 Amps 240Volts, Breaking capacity 10 KA \"C\" curve complete all as specified and directed. |
| 21 | Supply and fix as in repairs MCB TPN 63 Amps 415 Volts, Breaking capacity 10 KA \"C\" curve complete all as specified and directed. |
| 22 | Supply and fixing as in repairs vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed. Note: MCCB and MCB shall be of same make as of DB. |
| 23 | S&F as in repairs modular switch 10 Amp one way switch one module complete all as specified and directed. |
| 24 | S&Fas in repairs modular multi socket 10 Amp 2/3 pin two module complete all as specified and directed. |
| 25 | S&F as in repairsmodular switch 25 Amp one way switch one module complete all as specified and directed. |
| 26 | S&F as in repairsmodular socket 25 Amp 2/3 pin two module complete all as specified and directed. |
| 27 | S&F as in repairsmodular metal box with frame & cover and plate suitable for one module complete all as specified and directed. |
| 28 | S&Fas in repairs modular metal box with frame & cover and plate suitable for two module complete all as specified and directed. |
| 29 | S&Fas in repairs modular metal box with frame & cover and plate suitable for three module complete all as specified and directed. |
| 30 | S&Fas in repairs modular metal box with frame & cover and plate suitable for four module complete all as specified and directed. |
| 31 | S&Fas in repairs modular metal box with frame & cover and plate suitable for six module complete all as specified and directed. |
| 32 | Taking down carefully defective Miniature fluorescent lamp/CFL/LED Bulb in Auditorium down light fitting by unscrewing from high bay (from false ceiling of approx height 60 feet) down to floor, dismantling and replacing defective parts like chokes, starter, flexible wire, bipin holders, blister, acrylic/glass cover andMFL Rod incl making good the disturbed surfaces of walls, ceiling etc.Note: The contractor will arrange their own Elevators/ Ladders for taking down & fixing of Light fitting & electric wiring upto 60 feet heights. |
| 33 | S & F in repairs High performanceback lit dimmable LED panel comes with dimming feature that helps to set the brightness level to 100 to 0 as per requirement for Auditorium lighting ,20W, 220 V & 50 Hz including necessary electrical connection ,driver, dimmer complete as specified and directed by Engg-in-Charge.Note- The light fittings and sub main wiring are to be replaced above and on false ceiling which is appx 10-15 mtr height and contractor has to provide and install necessary scaffolding works to carry out submain wiring and light fittings, Contractor shall also provide suitable safety equipment to labour for carry out work at such height. Rate for which are deemed to be included in the quoted rate. |
| 34 | Taking down the spot down light 36 Wfitted in existing cutting grooves of the ceiling as per site requirement without disturbing the ceiling approx 30 ft height. |
| 35 | Supply and fixing Luminaries round smart slim LED Panel with round recess LED lamp 12W, 220 V & 50 Hz including necessary electrical connection complete as specified and directed . |
| 36 | Supply & fixing in repairssheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with provision for fixing of one MCB SP 20 Amps complete all as specified and directed. |
| 37 | Supply and fixingin repairsstepped type electronic fan regulator , SP 230 Volt100/120 watt complete all as specified and directed. |
| 38 | M&L for Opening the wall mounted fan400/450 mm sweep, removing the burnt copper winding wire complete, cleaning the slots, stator and the rotors and rewindingwith existing gauge super enamelled copper conductor including varnishing and heating and re-installation of fan etc complete all as specified and directed. Note:(i) Spare / Part such as Bearing/ windingto be replaced shall be measured and paid for separately as \"Supply only\" under respective item.(ii) Cost of taking down of fan and re-fixing is included in unit rate of item. |
| 39 | Supply only ball bearing suitable for wall mounted fan of sweep 250 / 300 / 380 / 450mm complete all as specified and directed.Make : NBC/SKF/Tata |
| 40 | Supply and fixing as in repairs fibre made fan blade oftablefan / cabin fan / wall mounted fan / pedestal fan, colour and size as per existing complete all as specified and directed. |
| 41 | Supply and fixing as in repairs metal grill cover of table fan / cabin fan / wall mounted / pedestal fan 250 / 300 / 380 / 450mm sweep of existing make and colour as specified and directed. |
| 42 | Material and labour in repairs forEarthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground verticallyin pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal andcommon salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point.(ii) Earth pit shall be constructed minimum 0.5 metre away from earth. |
| 43 | Supply and fixing LED 150 W flood light fitting on pole /wall with lense , high luminousrectangular LED flood light with innovative thermal management and available with multiple optics and equipped with IP 66 protection better distribution applicable for area lighting including suitable mounting brackets nuts and boltsand electrical connection complete all as directed. |
| 44 | Taking out LT cable XLPE/PVC sheathed 1100 volts grade armoured with aluminium conductor carefully of any size from trenches, poles, under floor including taking out old bricks for further use/disposal all as specified and directed. |
| 45 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed. |
| 46 | Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out all as specified. |
| 47 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil all as specified. |
| 48 | Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level , complete all as specified and as directed. |
| 49 | Material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers to 180mm complete all as specified and directed.Note :- Punned thickness will be considered for payment purpose. |
| 50 | M&L for cover to underground cable with one layer of bricks using sub class B bricks (old size) laid flat across the cable complete all as specified and directed. |
| 51 | Material and labour for making cross hole suitable for 50 mm dia bore pipe including passing GI pipe of size 40 mm dia, below the road with the help of pressure pipe/ boring tools for passing the cable and removing of surplus soil to a distance not exceeding 100 mtr from work site all as directed. Note : Gi pipe to be measured and paid separately under relevant items,. |
| 52 | Supply,laying and testingin repair of 40 mm bore GI tubing (light grade) with new fittings, laying in floor/trenchesfor support UG cables as directed by Engr-in-Charge. |
| 53 | S&F in repair for kiosk box of minimum size 300x200x100 mm for luminaries control swithes, weather proof made out of PVC/HDPE fire retardant, non fusing, shock & rust proof, single piece moulded/SMC housing and SMC cover with hinged door, pole mounting type comprising of aluminium busbar TPN of 60 Amps with 6 Amps MCB, SPwith base channel , fixed on pole with MS, clamps 30x5 mm with necessary nuts, washer for Street light) |
| 54 | Supply and fixing in repairs recessed LED ceiling panel provided with best in class aesthetics premium white powder coated frame blends seamlessly with ceiling layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit. |
| 55 | Taking down existing ceiling board from height 05 to 10 mtr and refixing the same including necessary scaffolding complete all as specified and directed by Engr-In-Charge. |
| 56 | M&L for taking down and refixig after repair the air curtain of any size , removing the burnt copper winding wire complete, cleaning the slots, stator and the rotors and rewindingwith existing gauge super enamelled copper conductor including varnishing and heating and re-installation of fan,Servicing and repair of actuator, sensor, amplifier valve Pressure regulator, etc complete all directed. Note:(i) SpareParts required for repairing shall deemed to be included in the quoted rate. |