Tender For Server Room And Ups Room Renovation At Primary And Near Dr Site In Submarine Division, Mdl, Mumbai, Mumbai-Maharashtra

Mazagon Dock Limited has published Tender For Server Room And Ups Room Renovation At Primary And Near Dr Site In Submarine Division, Mdl, Mumbai. Submission Date for this Tender is 18-07-2023. Barriers Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

38243537
Corrigendum : Tender For Server Room And Ups Room Renovation At Primary And Near Dr Site In Submarine Division, Mdl, Mumbai
Open Tender
Indian
Maharashtra
Mumbai
18-07-2023

Tender Details

Tender For Server Room And Ups Room Renovation At Primary And Near Dr Site In Submarine Division, Mdl, Mumbai-- 1 Biometric Access Control ( Finger ) 2 Fire Suppression System ( Novec 1230 ) 3 Spares ( Fire Suppression System ) 4 Vesda System 5 Fire Retardant Partition 6 Fire Alarm System ( Addressable ) 7 Environmental Monitoring System 8 3 Ton Pac ( Precision Air Conditioner ) 9 Comprehensive Warranty Of 2 Years 10 Supplyinganderectingminifeeder Pillar Triple Pole With200a Fpmccb As Incomer And2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100Aconsists Ofaluminium Bus Bar500 V200 Acomplete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation As Per Specification No. Sw-Swr / Mfp 11 Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core120sq. Mm. Aluminiumconductor Withcontinuous12.97 Sq. Mm. ( 8 Swg ) G.I. Earth Wire Completeerected With Glands 12 Supplyinganderectingtriplepoleand Neutraldistribution Board ( Tpndb ) Surface / Flushmounted Sp / Tp Of 24 Poles / 8 Ways On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb 13 Providing & Erecting 3 Pole Mccb Upto 100A, 415V, With Short Circuitrating 25 Ka ( Ics=100% Of Icu ) , Adjustablethermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, In Provided Enclosure On Iron / Gi Frameas Per Specification No. Sw-Swr / Mccb 14 Supplying, Erecting & Marking Tpmcb 6 A To 32A Inprovided Distribution Board As Per Specification No. Sw-Swr / Mcb 15 Supplying, Erecting & Marking Tpmcb 40A To 63A Inprovided Distribution Board As Per Specification No. Sw-Swr / Mcb 16 Supplying, Erecting & Terminating Xlpe Armoured Cable 3½Core70sq. Mm. Aluminium Conductor Withcontinuous8.35 Sq. Mm. ( 10 Swg ) G.I. Earth Wire Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al 17 Supplying, Erecting& Terminating Xlpe Armoured Cable 4 Core 16 Sq. Mm. Copper Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 18 Supplying, Erecting& Terminatingxlpe Armoured Cable 4 Core6 Sq. Mm. Copperconductor Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Cu 19 Supplying & Erecting Original 1.25 Mm Crca Sheet Metalenclosures With 30A, 3 Pin Plug & Earth Socket And 30 A 3 Pin Plug Top With 30A Triple Pole Mcb Complete Erected On Angle Iron / Gi Frame. 20 Supplyingand Erecting Single Pole And Neutral Distributionboard ( Spndb ) With Door Surface / Flush Mountedwith 2 Polesfor Incoming And 10 Poles For Outgoing Sp Mcb’Son Iron / Gi Frameas Per Specification No. Sw-Swr / Mcbdb 21 Supplying, Erecting & Marking Dpmcb 6 A To 32 A B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 22 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 23 Point Wiringfor Independent Plug In Pvc Trunking ( Casingcapping ) With 1.5 Sq.Mm ( 2+1E ) Fr Grade Copper Wire With Flush Type Switch And Requiredaccessories As Per Specification No: Wg-Pw / Sw 24 Secondary Point Wiring For Additionallight / Bell Point Inpointpvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Fr / Frlsh Grade Copper Wire With Required Accessories As Per Specification No: Wg-Pw / Sw 25 Supplying And Erecting Pvc Surface Modular Switch Box Withdouble Mounting & Front Plate For 8 Modules Complete Duly Connected. 26 Supplying And Erecting Isi Mark Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. 27 Supplying And Erecting Isi Mark Modular Type Switch 16A Dulyerected On Provided Plate And Box With Wiring Connections Complete. 28 Supplying And Erecting Isi Mark Modular Type 3 Pin 6A Multisockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 29 Supplying And Erecting Isi Mark Modular Type 3 Pin 6 / 16Amulti Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 30 Supplying And Erecting Triple Pole Metal Clad Switch Andfuse 415V, 100A On Angle Iron / Gi Frame As Per Specification No. Sw-Swr / Mtp. 31 Supplying, Erecting & Terminatingxlpe Armoured Cable 3½Core50 Sq. Mm. Aluminium Conductor Withcontinuous5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al 32 Supplyingand Erecting Single Pole And Neutral Distributionboard ( Spndb ) With Door Surface / Flush Mountedwith 2 Polesfor Incoming And 10 Poles For Outgoing Sp Mcb’Son Iron / Gi Frameas Per Specification No. Sw-Swr / Mcbdb 33 Supplying, Erecting & Marking Dpmcb 6 A To 32 A B- Series ( For Lighting ) Inprovideddistribution Board As Per Specification No. Sw-Swr / Mcb 34 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 35 Providing & Erecting Hot Dipped Galvanized Cover Suitablefor Perforated Type Cable Tray Manufactured From 18 Swg ( 1.2 Mm Thick ) Gi Sheet Of 150 Mm Width & 20 Mm Height Complete With Necessary Hardware In Approved Manner. 36 Supplying And Erecting Fr Grade, Pvc Armoured Multimodeoptical Fibre Cablewith 6 Fibres, With Core Dia 50 / 125 Μm ( Om3 ) Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench As Per Specification No. Wg-Coc / Ofc Lszh 37 Supplying & Laying Hms Pvc Conduit 20 Mm Dia. Withnecessary Accessories In Rcc Work / False Ceiling / False Flooring As Per Specification No. Wg-Ma / Cc.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jul-2023 Corrigendum-I Financial Bid 11-07-2023
2 11-Jul-2023 Corrigendum-2 Date 18-07-2023

Key Value

Document Fees
Refer document
EMD
INR 620000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Server Room and UPS Room Renovation at Primary and Near DR Site in Submarine Division, MDL, Mumbai
Sl. No. Item Description
1Biometric Access Control (Finger)
2Fire Suppression System (NOVEC 1230)
3Spares (Fire Suppression System)
4VESDA System
5Fire Retardant Partition
6Fire Alarm System (Addressable)
7Environmental Monitoring System
83 Ton PAC (Precision Air Conditioner)
9Comprehensive Warranty of 2 Years
10Supplyinganderectingminifeeder pillar triple pole with200A FPMCCB as incomer and2 outgoing circuits with HRC fuse base and cartridge of 100Aconsists ofaluminium bus bar500 V200 Acomplete erected in 14 gauge CRCA sheet box with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
11Supplying, erecting & terminating XLPE armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous12.97 sq. mm. (8 SWG) G.I. earth wire completeerected with glands
12Supplyinganderectingtriplepoleand neutral distribution board (TPNDB) surface/ flushmounted SP / TP of 24 poles/8 ways on iron / GI frame(vertical busbar type)as per specification no. SW-SWR/MCBDB
13Providing & erecting 3 Pole MCCB upto 100A, 415V,with short circuitrating 25 kA (Ics=100% of Icu ),adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB
14Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB
15Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
16Supplying, erecting & terminating XLPE armoured cable 3½core70sq. mm. aluminium conductor withcontinuous8.35 sq. mm. (10 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
17Supplying, erecting& terminating XLPE armoured cable 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
18Supplying, erecting& terminatingXLPE armoured cable 4 core6 sq. mm. copperconductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
19Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 30A, 3 pin plug & earth socket and 30 A 3 pin plug top with 30A triple pole MCB complete erected on angle iron/ GI frame.
20Supplyingand erecting single pole and neutral distributionboard (SPNDB) with door surface/flush mountedwith 2 polesfor incoming and 10 poles for outgoing SP MCB’son iron/ GI frameas per specification no. SW- SWR/MCBDB
21Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
22Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
23Point wiringfor independent plug in PVC trunking (casingcapping) with 1.5 sq.mm (2+1E) FR grade copper wire with flush type switch and requiredaccessories as per specification No: WG-PW/SW
24Secondary point wiring for additionallight/ bell point inPoint PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR/ FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
25Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 modules complete duly connected.
26Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
27Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
28Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
29Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
30Supplying and erecting triple pole metal clad switch and fuse 415V, 100A on angle iron / GI frame as per specification no. SW-SWR/MTP.
31Supplying, erecting & terminatingXLPE armoured cable 3½core50 sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
32Supplyingand erecting single pole and neutral distributionboard (SPNDB) with door surface/flush mountedwith 2 polesfor incoming and 10 poles for outgoing SP MCB’son iron/ GI frameas per specification no. SW-SWR/MCBDB
33Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) inprovideddistribution board as per specification no. SW-SWR/MCB
34Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
35Providing & erecting Hot dipped galvanized cover suitablefor perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner.
36Supplying and erecting FR grade, pvc armoured multimodeoptical fibre cablewith 6 fibres, with core dia 50/125 µm (OM3) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC LSZH
37Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.