| 1 | All in all maintenance to keep up trafficam Cameras with Software & Hardware complete in all respect. |
| 2 | Traffican Camera with Power Supply |
| 3 | Modules |
| 4 | All in all maintenance of UPS (5 KV) to keep up in working order |
| 5 | All in the maintenance to keep up to complete ATCS in working order. The System is based on CDAC Techology working on composite signals control strategy (CoSicoST) Software installed at 58 Nos. Junctions on Tonk road, M.I. road, JLN Marg, Ashok Marg |
| 6 | All in all maintenance of Air Conditioner to keep up in working order |
| 7 | Rent for 100 Mbps for connectivity for operation of TCS (Rent & Maintenance of OFC) |
| 8 | All in all maintenance to keep up of complete traffic signal system in working order at a crossing including controller, posts , head assembly, bulbs/LED reflector, material (Consumables / Software of OEM of traffic signal to be used only) T&P etc. as required. (CDAC Technology’s/software’s controller. Operated with Solar Panel with Battery |
| 9 | All in all maintenance to keep up of complete traffic signal system in working order at a crossing including controller, posts , head assembly, bulbs/LED reflector, material (Consumables / Software of OEM of traffic signal to be used only) T&P etc. as required. Complete Rate |
| 10 | With solid-state controller & LED Signal Heads |
| 11 | With UTCS controller & LED Signal Heads |
| 12 | With microprocessor controller & LED Signal Heads |
| 13 | Programmable Three Digit Countdown timer Big / Small |
| 14 | All in all maintenance to keep up blinker signal in working order at a crossing including controller, posts , head assembly, bulbs / LED reflector and material , T&P as required. Complete Rate |
| 15 | All in all maintenance to keep up Crystal control solar road warning blinker signal with solar panel in working order at a crossing including controller, posts , head assembly, bulbs / LED reflector and material , T&P as required. Complete Rate |
| 16 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. Complete Rate Armoured |
| 17 | 2.5 Sq. mm, 4 Core |
| 18 | SITC of Cutting back up surface up to 2 Mtr. Depth by diggingby Bogi including all layers of crust for laying pipe line etc. and making good to original condition (excluding cost of bitumen) |
| 19 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 90 / 76 mm Complete Rate |
| 20 | SITC of microprocessor based UTCS type automatic electronic controller conforming to IS: 7537 for traffic signals complete with electronic timer, G.P.S. based control board, blinker unit for night operation and slip lane, day time peak hours operation. The controller shall have 32 signal phases, 25 Signal Plan,24 Cycle Plan, 32 Signal Split Plan,32 Cycle switching/days,20 selective days /annum, 16 conflicting conditions, 32 signal line, solid state relay switching R.S 485 communication and 4 hurry call inter phase, manual override facility up gradable vehicle actuated system, also have method of traffic control with fixed time isolated intersection and cable less/ cabled interlinking for synchronizedoperation. The unit shall be totally enclosed in 2.00mm thick metal sheet box size 99 cm x 61.5 cm x 35.5 cm including making connection (C-DACmake). |
| 21 | Labour Rate |
| 22 | Complete Rate |
| 23 | S.I.T.C. of programmable three digit digital count down timer with 5mm dia. Red colored LEDs of high intensity ( visible clearly at day time) of reputed make with digit size 150mm x 300mm approx. and quantity of LEDs be approx. 800 no.s including interconnection with traffic signal controller and housing the LED assembly in sheet metal box of size approx. 750mm x 550mm with detachable pole arms clamps etc. as required. Keltron / Shakti / BEL Complete Rate |
| 24 | P & F 4.5 mm thick M.S. traffic post with outer dia. 114.3mm, medium class and confirming to IS:1239 (P-I) 5 Mtr. Long (0.8 Mtr. below ground level) suitable for mounting the signal head assembly with weather proof fiber cap and M.S. base plate 300 mm x 300 mm x 6 mm including excavation of pit and grouting with P.C.C. of ratio 1:3:6 from bottom of the pole and up to 30 cm. above the ground level and 40 cm dia. including painting with rubber paint below ground level and red oxide on exposed surface and finishing with traffic yellow enamel paint in two coats compete as required. Complete Rate |
| 25 | P & F M.S. cantilever swaged pole suitable for mounting signal head assembly of overall height 9.0 Mtr. (1.5 meter. Below ground level) with M.S. base plate of size 400mm x 400mm x 7mm including excavation of pit and grouting with P.C.C. of ratio 1:3:6 from the bottom of the pole and up to 50cm above the ground level of 40 cm dia. Including painting with rubber coat below ground level and red oxide on exposed surface and finishing with two coats of traffic yellow enamel paint complete in all respect as required. The pole shall confirm following specifications as per IS: (1239 P-I) Top, middle, bottom length1.80mtr,3.60 Mtr.,6.0 Mtr. Respectively, outer dia. 88.9 mm, 114.3 mm, 139.7 mm respectively, thickness 4.05 mm,4.5 mm,4.85 mm respectively. Complete Rate |
| 26 | SITC of Crystal control Solar Road warning Blinker system with solar panel module with 300mm LED Module of minimum 190 Nos., Blinker Units, Charging circuit, suitable SMF Rechargeable Battery (12 Volt), including wiring, connections etc. complete in all respect. Complete Rate |
| 27 | SITC of Solar panel Module 12 Volt 18 Walt, REIL, SHAKTI, BEL |
| 28 | STIC of SurveyorVFT (IP Dome) APTZ Camera with 360 degree rotation and digital zoom facility, which is also a transmitter. It can be connected straight to the net work, video trransmission via IP Coaxial,Fibre Optic or twisted Pair (UTP) in ceiling or pendant configurations for indoor or outdoor installation with Ex view 23X or 35X high resolution color on day/night camera with Vandal proof and pressurized housings and privacy masking. Complete Rate |
| 29 | Supply & Fixing of Spare cards for UTCS microprocessor controller of C DAC Technology. |
| 30 | Microprocessor C.P.U.Card Complete Rate |
| 31 | Microprocessor Lamp Driver Card Complete Rate |
| 32 | S.I.T.C. of following colour retrofit LED matrices traffic light of modular size 300 mm dia. Covered with front clear acrylic sheet and back with aluminium body, InP/ InGaN based 5mm dia. coloured LEDs of ultra bright, super intensity ( visible clearly at day time up to distance 300-600 meter , viewing angle of 30 degree). The unit shall be suitable for working on A.C. supply (160 - 240 V) and life cycle approx. 10 yrs with power consumption below 24 Watts , suitable for fast switching.( Makes - Binay, Keltron, Shakti, Bel or approved make). Complete Rate |
| 33 | Red / Amber Round ( Unit of 200-220NosLEDs) |
| 34 | Green Arrow( Unit of 120-130NosLEDs) |
| 35 | Add extra for SITC of M.S. housing for LED matrices |
| 36 | Refixing of standard traffic post including repair and transportation (within municipal limit ) as required. Including excavation of pit and grouting with P.C.C. of ratio 1:3:6 from the bottom of pole (0.80 meter. Below ground level) and up to 30 cm above the ground level and 40 cm dia. including painting with rubber coat below ground level as required. Complete Rate |
| 37 | Refixing of cantilever traffic post including repair and transportation (within municipal limit ) as required. Including excavation of pit and grouting with P.C.C. of ratio 1:3:6 from the bottom of pole (1.40 meter. Below ground level) and up to 50 cm above the ground level and 40 cm dia. including painting with rubber coat below ground level as required. Complete Rate |
| 38 | Removing of existing damaged standard traffic post (incl. Signal head assembly ) and dismantling original foundation and refilling the same with earth and transportation of pole and signal head to store (within municipal limit) as required. Complete Rate |
| 39 | Removing of existing damaged cantilever traffic post (incl. Signal head) and dismantling original foundation and refilling the same with earth and transportation of pole and signal head to store (within municipal limit) as required. Complete Rate |
| 40 | Painting of existing traffic post /cantilever pole /signal head assembly/controller box including removing of old rusted surface paint and applying red oxide finishing two coats of enamel paint as required. Complete Rate |
| 41 | Traffic Post |
| 42 | Cantilever Pole |
| 43 | Signal head assembly 300 mm dia. |
| 44 | SITC of WitraC 32Bit Microcontroller based Solar Power/PWM Automatic Electronic controller, conforming to IEC-60068(ERTL) for Traffic Signals complete with electronic timer, G.P.S. based control board, blinker unit for night operation and slip lane, day time peak hours operation, The controller shall have 32 signal phase, signal switching and feedback on wireless medium, 24 cycle plan, 32 signal split plan, 24 cycle switching/days, 20 selective days/annum, 4-week plan, 16 optically isolated solid state lamp driving outputs, 16 optically isolated vehicle detector, 20 × 4 LED backlit LCD and 5 × 4 keypad 8 Auxiliary I/O interface, USB, CAN, R.S. 232 communication and 4 hurry call inter phase, manual override facility up gradable vehicle actuated system, also have method of traffic control with fixed time isolated intersection and cable less/cabled interlinking for synchronized operation, including additional features such as (a) facility to enter traffic volume, (b) Provision for 3 to 5 second Red/Green flash before starting of stage, (c) Red light violation data from all the approaches and (d) Using External Ethernet adapter to USB for using 3G dongle router for Networking and making connections. (Technology developed by CDAC , Make CDAC, Shakti, Keltron ) |
| 45 | Master controller (Size L-607 × W-298 × D-176mm.) 12V DC ±10% 3.6W |
| 46 | Slave controller (L-400 × W-298 × D-176 MM) 12V DC ± 10% 3.0W |
| 47 | Supply, Installation, Testing & Commissioning of 7.5M height galvanised polygonal signal pole with dia 350mm A/F, 4mm thickness with 6M cross arm with dia 90 mm A/F, thickness 4 mm fabricated from HT steel confirming to BS EN 10025, S-355 JO with 520×16mm base plate. (Make CDAC, Shakti, Keltron, Bajaj) |