| 1 | Labour for taking out door and window frame including shutter for repair or replacemnt of different part of the frame and refixing the same including mending good alldamages complete.(Concrete and brick work for mending damage will be paid separately).(a) up to area 2.5 sq.m. |
| 2 | Supplying, fitting & fixing fire resistant door frame conforming toIS:3614, tested and certified as per laboratory approved by Engineerin-charge, of section 143 x 57 mm having built in rebate made out of16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filledwith vermuculite based concrete mix, suitable for mounting 120minutes fire rated door shutters. The frame is fitted with intumescentfire seal strip of size 10x4 mm (minimum) alround the frame andfixing with back plate bracket and anchor fastener of approved sizeand make. Rubber door silencers should be provided on strikingjamb |
| 3 | Supplying, fitting & fixing fire resistant Door leaf of 46 mm thickfully flush double skin glazed fire resistant door shutters with orwithout vision lite, of 120 minutes fire rating conforming to IS:3614(Part-II), tested and certified as per laboratory approved byEngineer-in-charge, with suitable mounting on door frame,consisting of vertical styles, lock rail, top rail 100 mm wide, bottomrail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating notless than 120 gm/ m2) duly filled heat-resistant phenolic resinbonded insulation material (honeycomb craft) and fixing withnecessary stainless steel ball bearing hinges of approved make. Forpair of doors astragals has to be provided on the meeting stile forboth active and inactive leaf. Vision lite wherever applicable shouldbe provided as per manufacturer recommendation with a beedingand screw from inside. The glass should be 6mm clear borosilicatefire rated glass of relevant rating.All door and frames shall be finished with polyurethene |
| 4 | aliphaticgrade paint of approved colour including applying a coat ofapproved brand fire resistant primer. The door leaf and frame shallhave passed minimum 250 hours of salt spray test. Rate shouldinclude supply and installation complete as per direction of Engineerin-chargei) 2 hour Fire rated door single leaf of size (1200 mm x 2180 mm) |
| 5 | Supplying, fitting & fixing fire resistant Door leaf of 46 mm thickfully flush double skin glazed fire resistant door shutters with orwithout vision lite, of 120 minutes fire rating conforming to IS:3614(Part-II), tested and certified as per laboratory approved byEngineer-in-charge, with suitable mounting on door frame,consisting of vertical styles, lock rail, top rail 100 mm wide, bottomrail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating notless than 120 gm/ m2) duly filled heat-resistant phenolic resinbonded insulation material (honeycomb craft) and fixing withnecessary stainless steel ball bearing hinges of approved make. Forpair of doors astragals has to be provided on the meeting stile forboth active and inactive leaf. Vision lite wherever applicable shouldbe provided as per manufacturer recommendation with a beedingand screw from inside. The glass should be 6mm clear borosilicatefire rated glass of relevant rating.All door and frames shall be finished with polyurethene |
| 6 | aliphaticgrade paint of approved colour including applying a coat ofapproved brand fire resistant primer. The door leaf and frame shallhave passed minimum 250 hours of salt spray test. Rate shouldinclude supply and installation complete as per direction of Engineerin-charge |
| 7 | ii) 2 hour Fire rated door double leaf of size (1470 mm x 2170 mm) |
| 8 | Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:(ix) 300 mm long x 10 mm dia. bolt. |
| 9 | Anodise aluminium Aldrop/Slidingbolts of approvedquality manufactured form extruded section conforming to I.S. specifictation (I.S.2681/66) fitted and fixed complete. |
| 10 | (iii) 300 mm x 16 mm dia. bolt. |
| 11 | Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hourfire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighingmaximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 ofapproved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge |
| 12 | for leaf width upto 950mm |
| 13 | for leaf width upto 1100mm |
| 14 | Supplying, fitting & fixing Stainless Steel \"D\" or \"H\" type of size 300 mm x 19 mmtubular Handle with Grade 304, CE certified, marked & conforming to EN -1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charges. |
| 15 | Supplying fitting & fixing concealed False ceiling Framework with G.I. Section(perimeter channels having one flange of 20 mm. and another flange of 30 mm.with thickness of 0.55 mm. and web of length 27 mm., along the perimeter of theceiling, screws fixed to the wall with help of nylon sleeves or PVC dash fastners@ 610 mm c/c. then suspend G.I. intermidiate \"C\" section with web 90 mm. andflanges of 15 mm. each from soffit @ 1200 mm c/c with ceiling angle of size 25mm. X 10 mm. X 0.55 mm. fixed to soffit G.I. Cleat and Steel expansion fasteners.Ceiling section of 0.55 mm. thickness having web of 51.5 mm. and two flanges of26 mm. each with lips of 10.55 mm., are then fixed on to the intermediate channelwith the help of connecting clips in the direction perpendicular to the intermidiatechannel @ 610 mm c/c) with fully threaded fiber cement screws @ 300 mm c/c.all complete as per the drawing and direction of Engineer-in-Charge.Section specification :- Perimeter Channel :- 30 mm X 20 mm X 27mm, thickness 0.55 mm (min), Intermidiate Channel :- 15 mm X 90 mm, thickness 0.90mm (min), Ceiling Section :- 51.5 mm X 26 mm X 10.55 mm, thickness 0.55 mm(min), Ceiling Angle :- 25 mm X 10 mm, thickness 0.55 mm (min). |
| 16 | Supplying fitting & fixing in position 9 mm thick Heavy Duty Cement board - Type-A (High Pressure steam cured, tested asper AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, density >1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 &ISO 8336, with fibre cement screws in partition excluding cost of supporting structure as per drawings and direction of Engineer-in-Charge complete. (Note: The Item -26 under Section - U(Page - 247) can be used as supporting structure for internal partition ). |
| 17 | (b) Rendring the surface of walls and ceilingwith white cement based wall putty of approved make and brand (15mm thick). |
| 18 | Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturer\"s specification)including cleaning and smoothning of surface.Two Coats |