Renovation Of Building ( Earlier Office Of Se / Canal Lining Circle ) To Establish Laborator, fazilka-Punjab

Water Resources Department-WRD has published Renovation Of Building ( Earlier Office Of Se / Canal Lining Circle ) To Establish Laborator. Submission Date for this Tender is 31-07-2023. Building Work Tenders in fazilka Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38206729
Corrigendum : Renovation Of Building ( Earlier Office Of Se / Canal Lining Circle ) To Establish Laborator
Open Tender
Indian
Punjab
fazilka
31-07-2023

Tender Details

Renovation Of Building ( Earlier Office Of Se / Canal Lining Circle ) To Establish Laborator

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jul-2023 Corrigendum1 Date 10-07-2023
2 13-Jul-2023 Date Extension Date 14-07-2023
3 14-Jul-2023 Corrigendum2 Date 17-07-2023
4 17-Jul-2023 Corrigendum3 Date 20-07-2023
5 20-Jul-2023 Corrigendum4 Date 24-07-2023
6 24-Jul-2023 Corrigendum 5 Date 27-07-2023
7 27-Jul-2023 Corrigendum 6 Date 31-07-2023

Key Value

Document Fees
INR 5000 /-
EMD
INR 37076.0 /-
Tender Value
INR 18.53 Lakhs /-

BOQ Items

Name of Work: RENOVATION OF BUILDING (EARLIER OFFICE OF SE/CANAL LINING CIRCLE) TO ESTABLISH LABORATORY
Sl. No. Item Description
1Surface dressing of ground including removing rank vegetation and in equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5 m in all kinds of soil
2Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
3Cement Concrete 1:4:8 with stone ballast of size 40 mm gauge.(mechanically mixed)
4First class burnt brickwork laid in cement sand mortar 1:4 in foundation andplinth
5Centring and shuttering for flat surface such as Suspended floors, Roofs, Landing, Chhajjas, Shelves etc.
6steel reinforcement For Roof Slab and Door lintel @ 80Kg Per Cum of Concrete.
7Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
8Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needal vibrater butexcluding steel reinforcement centring and shuttering in Superstructure
910mm thick Cement Plaster 1:2
10Cement rendering on plaster 1mm thick
11Corrugated G.I. Sheet roofing 0.47 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses
12Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and to the entire satisfaction of engineer-in- charge. Height up to 4 m
13Providing and laying vitrified floor tiles in different sizes in light colour shades made using Soluble Salt Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Soluble salt Print Penetration should be up to 1 to 2 mm after the tiles are fired & polished ). Size 600x600 mm
14Door and window frame of size 113mmx60mmx with 35mm wide single rebate
15Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
16Finishing walls with exterior decorative cement based such as snowecem, robbiacem etc. on old work one coat to give an even shade
17Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed
18Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes.
19CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
20CPVC SDR 11 Pipe & fitting 16mm o/d
21SDR 11 CPVC pipes & fittings 20mm o/d
22CPVC SDR 11 Pipe & fitting 25mm o/d
23Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect. 25mm i/d G.I. Union
24Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
25Single Socket Type A
26160mm o/d single socket SWR UPVC pipe lines laid complete
27110mm o/d single socket SWR UPVC pipe lines laid complete
28Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. With 100mm x 75mm i/d Floor Trap (weighing 4.0 Kg)
29Constructing brick masonry road gully chambers as per standard drawings (asper sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete. Single road gully chamber :- Size 610mm x 457mm x 800mm
30Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tank
31Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 25mmi/d
32Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 560mm x 450 mm (under counter oval)
33RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
34Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powderoated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface)
35Wiring fan point (Without fan box)
36Wiring light point
37Wiring call-bell point
38Wiring 6Amp. wall socket point
39Wiring 6Amp. Plug control comprising wall socket point
40Wiring 16/20Amp. power plug control point
41Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
42Overall size 1.5sq.mm (Un-sheathed)(earth)
43Overall size 4sq.mm (Un-sheathed)
44Erection of 1X20/28/36/40W Box Type (LED/ Fluorescent) light fixture
45Supply and erection of Miniature Circuit Breaker
46MCB Single Pole 6-32amp. (10kA, Curve-C)
47MCB Double Pole 6-32amp. (10kA, Curve C)
48SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB"s/ RCBO"s/ RCCB"s. SP&N Double Door Distribution Board 4 way each
49Any Other
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail