| 1 | Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales murams and ordinary gravel and hard dravel including shoring, strutting, baling or pumping out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick and depositing the surplus earth at places as directed by the departmental officers with initial lead and lift |
| 2 | a). Narrow Foundation |
| 3 | b). Open Excavation |
| 4 | Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 5 | Plain cement concrete 1:4:8 mix (One cement four sand and eight aggregate) using 40mm size ISS gauge HBBG metal including mixing,laying, consolidating, curing, cost and conveyance of all materials to site and all labour charges etc., complete |
| 6 | Supplying and errecting centering to sides and soffits including supports and struttingfor drainage sides andculvert body wall sidesusing M.S Sheets of size90cm x 60cm and B.G 10stifenedwith welded mild steel angles of size 25mm x 25mm x 3mm for boardinglaid over (silver oak joists) of size 10cm x 6.50cm spread at about 90cm including all labour charges and cost and conveyance of all materials to site etc. complete |
| 7 | a). Square Columns |
| 8 | b). Grade Beam |
| 9 | c). Plain Surface |
| 10 | Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. |
| 11 | Reinforced cement concrete 1:1½:3 mix (One cement one and half CS sand three aggregate) using 20mm ISS gauge HBBG metal from the approved quarry including mixing, laying, consolidating, curing cost and conveyance of all materials to site and all labourcharges etc., complete as per standard specification |
| 12 | a). Foundation & Basement |
| 13 | b). Ground Floor |
| 14 | Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm (8 3/4\" x 41/4\" x 23/4\") from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications |
| 15 | a). Foundation & Basement |
| 16 | b). Ground Floor |
| 17 | Collection,supply and filling ofWell gravel from approved quarry to work site and stocking to the Departmental gauge for premeasurement as directed by the Departmental Engineer, to required depth not more than 15cm depth including cost andConveyance ofgravel to site and all labour charges for filling etc., Complete |
| 18 | Supplying and fixing MS grill to doors windows and ventilators etc. as directed by the departmental officers inclusive of cost of MS grill and labour charges including one coat of red oxide and fixing in position etc. complete |
| 19 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 20 | Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel Hold fast etc. |
| 21 | FRP Door Sutter with FRP Doorframes made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with ebate suitably reinforced using MS angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wallthickness for styles and rails etc., of sizes specified by Engineers |
| 22 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work |
| 23 | Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. |
| 24 | Special Ceiling Plastering for RCC slabs and beams with cement mortar 1:3 mix 10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications. |
| 25 | Plastering with cement mortar 1:5 mix, 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications |
| 26 | Weathering course over roof slab using 20 mm size brick jelly mixed with pure slacked lime no sand to be used the proportion being 32:121/2 including cost and convenience of all materials to working site, well beating with wooden beaters giving necessary slope and thickness including finishing neatly etc. |
| 27 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 28 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 29 | Painting two coats with approved cement paint over cement plastered surface ceiling and other new surface includingcleaningprepering thesurfaceandcuringetc.,complete |
| 30 | Painting two coats with best synthetic enamel paint of approved Colour for new iron works the rate is inclusive of all materials, brushes and scaffolding charges etc., complete complying with standard specification(paint should be got approved by the Departmental Engineer befor use on work. |
| 31 | Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathedCu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For electronic regulator). (SD-23) |
| 32 | Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x l00 x for open PVC plug point.inter locking CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for PVC Plug Point (SD-36) |
| 33 | Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point. (SD-39) |
| 34 | Supply and fixing of single box type 4\"x18w crystal glass LED Tube light with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. (SD-88) |
| 35 | Supply and fixing of 1200 mm (48\") AC ceiling fan complete with stepped electronic 300W regulator with 1meter down rod on the existing clamp. (SD-107) |
| 36 | Supplying and fixing in position P.V.C. specials such as plain bend, door bend, plain tee, door tee, offsets,Y-junction, plain or with door of various sizes best quality confirming to I.S.S and providing leakproof joints including fixing to wall and giving connection to the P.V.C, soil stacks, dismadling the brick masonry or R.C.C.floor or Roof slab and redoing the dismandled portion to original condition etc., complete complying with standard specifications. As per IS 4985 / 2000 and IS 10124 / 1982 Part II |
| 37 | 110mm Dia PVC Pipe 6 Ksc (IS 4985 / 2000) |
| 38 | 110mm Dia PVC Elbow (IS 10124 / 1982) |
| 39 | 110mm Dia PVC Tee (IS 10124 / 1982) |
| 40 | 110mm Dia PVC Bend (IS 10124 / 1982) |
| 41 | GST 18% |