Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-07-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-07-2023 |
| 2 | 26-06-2023 | 83020AMDTSTODATES2 | Date | 07-07-2023 |
| 3 | 26-06-2023 | 83020AMDTSTENDERPAGES2ANDBOQ | BOQ | 07-07-2023 |
| 4 | 23-06-2023 | 83020AMDTSTODATES1 | Date | 04-07-2023 |
| 5 | 21-06-2023 | 83020AMDTSTENDERPAGES1ANDBOQ | BOQ | 30-06-2023 |
| Sl. No. | Item Description |
| 1 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on wall (upto 4storey) complete all as specified and directed. |
| 2 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on wall (5 to 8 storey) complete all as specified and directed. |
| 3 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on wall (9 to 12 storey) complete all as specified and directed. |
| 4 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on wall (13 storey) complete all as specified and directed. |
| 5 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on ceiling (upto 4 storey). complete all as specified and directed. |
| 6 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on ceiling (5 to 8 storey). complete all as specified and directed. |
| 7 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on ceiling (9 to12 storey) complete all as specified and directed. |
| 8 | M&L for Preparation of old decorated plastered or unplastered surfaces incl brooming down with steel wire brushing removing silt, Efflorescence etc and applying one coat of white wash on ceiling (13 storey) complete all as specified and directed. |
| 9 | M&L for two component polymer modified flexible cementitious waterproof (breathable) coating of equivalent flexible and elastic polymer modified, 2 component cementitious coating system having UV resistance applied in 2 coats in the form of slurry at right angles byway of brush at a total consumption of 2 Kg per sqm over the vertical brick wall, curing, testing etc completed including gola vata & joints treatment etc. complete all as specified and directed. |
| 10 | M&L for providing protective levelling plaster for horizontal & vertical surface of average 15 thick in cement mortar (1:4) including mixed with liquid integral waterproofing admixture @ 200 ml per bag of cement, finished smooth, curingetc. complete all as specified and directed. |
| 11 | M&L for preparation of old deterioratedexternal wall / Ceiling surface of existing treatmentby scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc.or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible up to G+13 storey bldg complete all as specified and directed. |
| 12 | M&L for preparation of external wall / Ceilingapplyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primer up to G+13 storey bldg complete all as specified anddirected . |
| 13 | All as per item No 12 above but newly plastered surfaces complete all as specified and directed. |
| 14 | M& L for Preparation of old plastered internal wall/ceiling surfaces etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots andapplying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surfacecomplete all as specified and directed. Note : - 1. Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. (upto G+13 storey).2. Item no 1.00 to 4.00 The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Primer,White wash,Exterior emulsion paint,Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Engineer-in-Charge.3. The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with Auth aplicator & 5 yrs warranty. |
| 15 | All as per item No 14 above but newly plastered surfacesNote for Item No. 1 to 5 : 1. Stage for prepration of surfaces shall be got approved from AGE(I) before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator3. The contractor shall make his own arrangement of scafolding upto G+13 storied bldg. The cost of scafolding is deemed to be included in the amount quoted by contractor. Contractor will also ensure the safety and security of labours & workers. The work shall be carried out in close supervision of the contractor. |
| 16 | Taking down cement plaster on brick walls, or stone walls / ceilings etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.Note rate quoted up to G+13 bldg including scaffolding |
| 17 | M&L for 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plasterup to G+13 bldg including scaffolding . complete all as specified and directed by engineer-in-charge complete all as specified and directed compound complete. |
| 18 | M&L for preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coats of Synthetic enamel paint complete all as specified and directed.(Upto 4 th storey) |
| 19 | All as per item No 18 above but 5 to 8 storeys. |
| 20 | All as per item No 18 above but 9 to 12 storeys. |
| 21 | All as per item No 18 above but 13 to 14 storeys. |
| 22 | M&L for Preparation of old painted steel surfaces over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete (upto 4 storey) |
| 23 | All as per item No 22 above but 5 to 8 storeys |
| 24 | All as per item No 22 above but 9 to 12 storeys |
| 25 | All as per item No 22 above but 13 to 14 storeys |
| 26 | M&L for Curtain rod Harrison rails, stainless steel with fixing brackets, stops, rollers etc. complete all as specified and directed . |
| 27 | Dismantling floor hearth or wall tiling including cment mortar bedding (incl backing), removing the rubbish off the premises of MOD land complete all as specified. |
| 28 | Dismantling Stone Slab including cement mortar bedding, removing the rubbish off the premises of MOD land complete all as specified. |
| 29 | M&L for 20mm thick granite work (table rubbed and polished) in steps, jambs, pillars window cills and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust and jointed with Granite epoxy/silicone glue incl 15mm thick Screed bedor beeding layer of mortar in CM 1:6 for laying floor finishes complete all as per specified and directed . |
| 30 | Rounding to edges of stone slabe one edge, such as steps, cooking platform and other similar situations and rubbing and polishing complete all as specified and directed. |
| 31 | M&L for Vitrified ceramic tiles light shade, 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm in floors etc set and joint in neat cement slurry and point in coloured cement to match the shade of tile complete incl 15mm thick Screed bedor beeding layer of mortar in CM 1:6 for laying floor finishes complete all as per specified or as directed . |
| 32 | Taking down eaves gutter and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the center line over fittings and accessories) and S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointed fixed to walls upto G+13 storey incl necessary formwork complete all as specified and as directed . (upto 4 storey) |
| 33 | All as per item No 32 above but 5 to 8 storeys |
| 34 | All as per item No 32 above but 9 to 12 storeys |
| 35 | All as per item No 32 above but 13 to 14 storeys |
| 36 | Taking down eaves gutter and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the center line over fittings and accessorie) S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointed fixed to walls upto G+13 storey incl necessary formwork complete all as specified and as directed.(upto 4 storey) |
| 37 | All as per item No 36 above but 5 to 8 storeys |
| 38 | All as per item No 36 above but 9 to 12 storeys |
| 39 | All as per item No 36 above but 13 to 14 storeys |
| 40 | S & F in repairs Stack clamps made out of50 mm by 5 mm flat iron and 16 mm dia around iron stays including boltand nuts for securingends of stays to walls or roofs, bore pipe 75 mm dia pipe upto 4th storeyof all buildingcomplete all as directed. |
| 41 | All as per item No 40 above but 5 to 8 storeys |
| 42 | All as per item No 40 above but 9 to 12 storeys |
| 43 | All as per item No 40 above but 13 to 14 storeys |
| 44 | S & Fin repairs Stack clamps made out of50 mm by 5 mm flat iron and 16 mm dia around iron stays including boltand nuts for securingends of stays to walls or roofs, bore pipe 100 mm dia pipe upto 4th storeyof all buildingcomplete all as directed. |
| 45 | All as per item No 44 above but 5 to 8 storeys |
| 46 | All as per item No 44 above but 9 to 12 storeys |
| 47 | All as per item No 44 above but 13 to 14 storeys |
| 48 | S & F PVC(SWR) bends of any radius with access door for PVC(SWR) pipes110mm bore complete all as specified and directed. |
| 49 | S & F PVC(SWR) bends of any radius with access door for PVC(SWR) pipes 75mm bore complete all as specified and directed. |
| 50 | S & F PVC (SWR) junction single, (Single T) equal or unequalwith access door pipes 75mm bore complete all as specified and directed |
| 51 | S & F PVC (SWR) junction single, (Single T) equal or unequalpipes with access door 110 mm bore complete all as specified and directed. |
| 52 | S & F PVC (SWR) junction single, (Double T) equal or unequalpipes with access door 75 mm bore complete all as specified and directed. |
| 53 | S & F PVC (SWR) junction single, (Double T) equal or unequalpipeswith access door 110 mm bore complete all as specified and directed. |
| 54 | S & F PVC(SWR) couplers for PVC(SWR) pipes110 mm bore complete all as specified and directed. |
| 55 | S & F PVC(SWR) couplers for PVC(SWR) pipes75 mm bore complete all as specified and directed. |
| 56 | S & F PVC(SWR) reducers for PVC(SWR) pipes110 mm bore complete all as specified and directed. |
| 57 | S & F 110 mmPVC(SWR) WC connecter bent type complete all as specified and directed. |
| 58 | S & F PVC(SWR) vent cowl for PVC(SWR) pipes75 mm bore complete all as specified and directed. |
| 59 | S & F PVC(SWR) vent cowl for PVC(SWR) pipes110 mm bore complete all as specified and directed. |
| 60 | M&L for PCC 1:2:4 type B1 in roof kerbs or mud stops rounded or chamfered edges,etc complete all as specified and directed. |
| 61 | M&L for injection grouting as under :-(i) Cleaning of marked surfaces with wire brush and washing with water, removing any foreign material like algae, dirt, oil etc(ii) cleaning of holes free froml dust/debris/loose material using blow compressed air followed by water injection(iii) Drilling hole of 16mm dia and about 40mm deep or half of the thickness of wall/slab@ 500 mm c/c (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty to ensure that there is no leakage from any gap.(v) Allow the epoxy putty to cure for 24 hours and ensure that firmly fixed in postion. (vi) cleaning nipple one by one commencing from the top to bottom using blow compressed air followed by water injection to ensure that there is no obstruction in free flow of grouting materials (vii) Injecting of \"Free flow non shirnk cementitious grout\" in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air. pressure shall be in the range as per order recommended by manufacturer. Mixing of resin and hardenere shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thoroughly.(ix) Allow entire effected surface to cure for 24 hours.(x) cutting out projected parts of the nipple & seal the hole in the nipple with epoxy putty as recommended by manufacturer.(xi) cleaning exposed surface of substrate off any dust /loose material after ageing of the grout as recommended by manufactuer. complete procedure shall be as per manufacturer instructions and as directed . Make : Fosroc/Sika/Fidilite/Dr Fixit |
| 62 | M & L for making wattah/coving of 50x50 mm at all construction joints of horizontal & vertical and junction of pipes outlets with food grade epoxy putty. complete procedure shall be as per manufacturer instructions and as directed by Engr-in-Charge. Make : Fosroc/Sika/Fidilite/Dr Fixit |
| 63 | M&L for water proof coating as under :-(i) Preparing the inner surfaces of walls and base of water tank including scrubbing the surface with wire brush, removing any foreign material like algae, dirt, oil etc(ii) Apply first coat of Acrylic polymer modified cementicious water proofing material (Part A liquid & Part B powder) such as \"Sika Top seal 107\" or equivalent on properly dried & cleaned RCC slab & wall and allow to dry for 6 to 8 hrs. (iii) Apply second coat and allow 24 hrs for dry.complete procedure shall be as per manufacturer instructions and as directed.Make : Fosroc/Sika/Fidilite/Dr Fixit |
| 64 | Taking down shutters of any description exc 1 sqm but not exc 2 Sqm each |
| 65 | S&F 40 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, one face is covered with decorative face veneer with lipping/frame to match incl approved II class Hardwood lipping around complete all as specified and directed. |
| 66 | S&F 200mm long stainless tower bolts fixed to door with complete all as specified and directed. (MAKE : KICH/ARCH/Q-RAIL/D-LINE, prayag) |
| 67 | S&F stainless steel mortice handles of AISI 316 Grade 150mm long specified and directed. (MAKE : KICH Cat No 1916Sor ARCH/Q-RAIL/D-LINE, prayag) |
| 68 | S&F in repairs for brass Mortice lock 4 levers, vertical type, size 100 mm complete all as specified and directed. |
| 69 | S&F 2nd class hard wood 35mm thick Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securinggauge,etc complete all as specified and directed. |
| 70 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 71 | S&F mild steel sliding door bolts,300 mm long plate type, stove enamelled black with bright bolt not less than 12 mm dia with and including minimum of 6 bolts and nuts,four on bolt plate and two on staple complete all as specified and directed. |
| 72 | Dismantling and taking down existing old damaged sign board complete on top floorincluding electrical connections, PCC work , complete and making good the disturbed surface etc all as specified and directed |
| 73 | Supply and installation of out door signage board on top floor with box type letters \"AKSHITA ENCLAVE INDIAN COAST GUARD\"with Indian coast guard symbol have top left corner \" at Sec 52 on top of G+13 bldg at Akshita enclavebuilding having the following specifications and all as directed by Engr in Charge..(a) Size of board should beapproved by Engr-in-Charge.(b) 3 MM thick Blue color ACP sheet should be provided as back panel.(c) Main frame work will be done by 50X50x6 Mm angle ironand the support structure will be of 40X40X6 MM including one coat of red oxide and two coat of synthetic enamel paint.(d) Foundation of angle iron structureshould be embedded in top wall of tower including PCC.(e) Raised height of the letter from base surface should not be less than 60 MM .(f) Size of letter should be as directed by Engg In charge. (g) Color of letter should be white.(h) High efficiency white color LED strip will be provided in each letter along with suitable driver , internal wiring andprovision of 01XSPN MCB 32 A along with sheet metel enclosurecomplete with necessary water proofing arragement.(j) Necessary arragement should be provided inside the box type letters to avoid scattering of light.(k) Rain shed to be provided with acrylic sheet cover fixed on fabricated structure of angle iron of size 50X50X6 MM. |
| 74 | MODULAR KITCHEN:Dismantling boarding, any description fixed in any position fixed with screws complete all asdirected. |
| 75 | S & F 18/19 mm thick post forming both side prelaminated PVC moulded solid kitchen cabinet boxes with shelf, drawer and shutter full size fitted under the kitchen cooking platform and other platform incl fittings etc complete all as specified and directed including provision of fixing arrangement Make- Rajshree or equivalent.Note:- (i) Contrcator has to submit the design and drg of Modular Kitchen before execution of work for approval of Engr-in-charge. |
| 76 | S&F in repairs 6 mm thick one side prelaminated decorative PVC sheet and other side plain in cupboard & like items inclusive of solvent cement & fixing at site complete all as specified and directed.e. Make- Rajshree or equivalent. |
| 77 | S&FModular auto concealed soft closed hinges 35mm 110 degree size complete all as specified and directed. |
| 78 | S&Fstainless steel handle 200mm complete all as specified and directed. |
| 79 | S&Fstainless steel handle 150mm complete all as specified and directed. |
| 80 | S&FPVC tape 18mm wide with adhesive complete all as specified and directed. |
| 81 | S&Fmultipurpose basket (470x535x150)mm stainless steel of grade 304 complete all as specified and directed. |
| 82 | S&Fperforated cutlary (475x485x350)mm stainless steel of grade 304 complete all as specified and directed. |
| 83 | S&F grain trolly with base (450x500x300)mm stainless steel of grade 304 complete all as specified and directed. |
| 84 | S&FThree tier trolley bottle pull out of size 485x530x150mm of stainless steel of grade 304 complete all as specified and directed. |
| 85 | S&Fbottle pull out 150x485x430 mm with two shelf stainless steel of grade 304 complete all as specified and directed. |
| 86 | S&Fcup & soucer basket(470x535x100)mm stainless steel of grade 304 complete all as specified and directed. |
| 87 | S&F plate basket (470x535x200)mm stainless steel of grade 304 complete all as specified and directed. |
| 88 | S&Fcylinder trolly stainless steel of grade 304 complete all as specified and directed. |
| 89 | S&Fbin holder stainless steel of grade 304 complete all as specified and directed. |
| 90 | S&Fdetergent holder (254x152x279 mm) stainless steel of grade 304 complete all as specified and directed. |
| 91 | S&Ffor Telescopic drawer channel rollers for shelves of size 350mm long completestainless steel of grade 304 complete all as specified and directed. |
| 92 | S&Ffor Telescopic drawer channel rollers for shelves of size 500mm long completestainless steel of grade 304 complete all as specified and directed. |
| 93 | S&F for wall mounted kitchen plate plate rack of size 900mmx600mmx250mm made out of 1mm thick stainless steel sheet of 304 AISI grade fixed to walls with required size of raw plug and steel screws as per manufacturer instructions. Make - PRAYAG/ BLUESTAR/ CERA/ SAPHHIRE/ BHARATI/ ARCHITA/ JAYNA/ NIRALI. description and pattern shall be as per sample complete all as specified and directed. |
| 94 | S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantileverbrackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160m complete all as specified and directed . |
| 95 | Toilet/BathDismantling floor hearth or wall tiling including cment mortar bedding (incl backing), removing the rubbish off the premises of MOD land complete all as specified. |
| 96 | M&L for Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and incl 10mm thick rendering for backing of tiles in CM 1:4 complete all as specified & directed. |
| 97 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match inc Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM 1:4 complete all as specified & directed. |
| 98 | M&L for applying three coats of polymer modified cementitious water proof coating as per manufacturer\"s specification to bottom and vertical sides upto skirting height complete all as specified and directed. |
| 99 | M&L forGuniting work in side and soffits of slabs, chajjas, fins,facias, parapets ,columns and beams etc complete including necessary scaffolding, shuttering at any height throughout the buildings including removing of small trees shrubs etc all as specified the following :-(i) chipping of spalled and loose concrete/plaster work and cleaning rust from re-inforcement by steel wire brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry(ii) Applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement(iii) Applying a layer of bonding coat of a layer of epoxy adhesive on complete exposed surfaces of concrete(iv) Guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions(v) Applying 5mm thick cement plaster in CM 1:3 over gunite surfaces to give an even uniform and smooth finish to match with the existing surface. Note: steel welded mesh to be welded with the existing reinforcement.The cost of labour/machinery work and all the material as mentioned above is deemed to be included in the quoted rate.Make of chemical : Fosroc/Pidilite/Sika |
| 100 | Dismantling wall and ceiling or insulation boards incl brackets and cover fillets complete all as specified anddirected. |
| 101 | S&F for anodisied aluminium snap grid of size 605 x 605mm frame work for false ceiling complete all as specified and directed. |
| 102 | S&F Hangers 6mm dia GI (upto 1200m length) adjustinglevel fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasterners 12.5 mm dia 40mm long complete all as specified and directed. |
| 103 | S&F 10mm thick multiwall (1 cell/2 wall) sandwich PVC sheet cut to shape and fixed in aluminium snap grid false ceiling complete all as specified and directed. |
| 104 | M&L for 5mm thick rendering in CM 1:3 on ceiling surfaces and finished even and smooth without using extra cement complete all as specified and directed. |
| 105 | Taking up or down steel tubing and connections 20 mm bore of pipe complete all as specified and directed. |
| 106 | S&F CPVC pipe SDR-11, 20 mm bore with plain SDR-11 fittings complete to walls and ceilings or laid floors or concealed,( cost for cutting chases in wall/ceiling for concealing tube shall be measured seperately) complete all as specified and directed. |
| 107 | S&F in repairs Central Hole Basin Mixer with Regular Spout including joints to steel pipe or unions complete all as specified and directed. Make : Cat No. QQT-7167B(Jaquar or equivalent) |
| 108 | S&F in repairs Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete complete all as specified and directed. (Make Cat No-QQT-7273UPR Jaquar or equivalent) |
| 109 | S&F in repairs Toilet paper holder with coverfixed to walls with chormium plated bracs screws complete complete all as specified and directed.. Make : Cat No- AHS-1553 (Parryware /Jaquar or equivalent) |
| 110 | S&F in repairs 2-Way Bib Cock with Wall Flange fixed to15mm dia MS pipe complete complete all as specified and directed. (Make Cat No-QQT-7041 parryware/Jaquar or equivalent) |
| 111 | S&F in repairs brass chromium plated shower rose of size 125 mm with 24\"\" Long arms including fixing to steel pipe complete all as specified and directed. (Make Cat No-OHS-1605 Parryware/ Jaquar or equivalent) |
| 112 | S&F in repairs Health faucet cast copper alloy chromium plated with flexible chrome hose and wall SS hooks completeall as specified and directed. Make : Cat No-ALD-573 Parryware / Jaquar) or equivalent) |
| 113 | S&F soap Dish holder fixed to wall completeall as specified and directed. (Make Cat No-ACN-1131N Parryware /Jaquar or equivalent) |
| 114 | S&F in repairs Angular Stop Cock with Wall Flange fixed to 15 mm dia MS pipe completeall as specified and directed.(Make Cat No-QQT-7053 parryware /Jaquar or equivalent) |
| 115 | S&F in repairs Grab bar 300mm Long, Stainless Steel Towel Railfixed to wall complete all as specified and directed. (MakeCat No-ACN-1101S Parryware /Jaquaror equivalent) |
| 116 | S&F 600mm long PVC connection pipe fixed to 15mm dia pipe complete all as specified and directed. |
| 117 | S&F sheet glass shelf assemble consisting of 5.5mm thick sheet glas shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed..(Make Jaguar AKB-35771 or parryware T6009A1 |
| 118 | S&F Corner sheet glass shelf with complet fittings complete all as specified and directed.(Make jaguar ACN-1173 or equivalent) |
| 119 | S&F 6mm thick looking mirror 900x800mm bevelled edge mirror of selected quality glass, mounted on 10mm thick PVC moulded prelaminated one side sheet and fixed to alaround 50mm wide PVC moulded frame with chromium plated brass screws and cup washers fixed to wall complete all as specified and directed. (Make : Parryware C863099 or equivalent) |
| 120 | M & L for Towel Ring Round with Round Flange incl complete fittings complete all as specified and directed. (Make ACN-1121BN Jagaur or equivalent) |
| 121 | S&F in repairsBib Cock with Wall Flange fixed to15mm dia pipe complete all as specified and directed. (Make Cat No-QQT-7037 Jaquar or equivalent) |
| 122 | S&F Bottle Trap 32mm Size with 300mm & 190mm Long Wall Connection Pipes & Wall Flange fixed to WHB complete all as specified and directed. (Make Cat No-ALD-769L300x190jaquar or equivalent) |
| 123 | Internal ElectrificationTaking down carefully of light fittings of any description and in any position completeas specified and directed. |
| 124 | Supply and fix LED batten luminaire surface mounted ,4 feet system wattage of not less than 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 5 years of replacement warranty on fittings completeallas specified and directed. |
| 125 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 10 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 5 years of replacement warranty on fittings completeallas specified and directed. |
| 126 | Supply & fix Linear & compact 10 W mirror light with 1000 Lumen outputdecorative grey end caps, polycarbonate body and ribbed opal diffuserPower Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 2.5 KV including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 127 | Supply and fix not less than 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficiency of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria,Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 128 | Supply and fixing wall mounted 20 watt indoor inverter batten with opel diffusor IP-20 with 4 hrs backup with output of 1800 lumens , box type (decorative) light fitting 230 volts 50 Hz with extruded alluminium heat sink provided for efficient heat dissipiation and integtrated electronic driver connector block etc complete with all acessories internally prewird and necessary mounting arrangements provision of new 3 core multistranded copper conductor of size 23/0.193 from ceilling rose to fitting including LED Tube 4\"x18 watt complete all as specified and directed.Make: Halonix cat no. LED INVERTER BATTEN HLB-08-20-CW-INV or equivalent of Phillips/Bajaj/Wipro. |
| 129 | M & Lfor sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4.0 Sqmm single core, copper conductor drawn through PVC cashing and caping of suitable size and single run 4.0 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 Volts grade, ISI marked as earth continuity wire complete all as specified and directed. |
| 130 | S & F Modular Switch, 1 Way, 16A, 1 Module suitable for fixing in modular cover plate. |
| 131 | S & F Modular Socket, 16A, 2/3 pin combined, 2 Module suitable for fixing in modular cover plate. |
| 132 | Supply and fix White cover plate with frame, 3 module complete including fixing tomodular metal flush box complete all as specified and directed. |
| 133 | Supply and fix modular metal flush box 3 module (thickness not less than 3 mm) complete including flush to wall all as specified and directed. |
| 134 | S & F kitchen elctric chimney (Filter less) single phase 230 volts 50 Hz filter less ,suctionairflow of 1200 Cum/Hr, 150 watt motor,1.5 watt LED lamp, 3 speed settings,metallic motor housing, GPSP Painted touch control with motion sensor,suction area 600 x 316 mm complete including connecting of suction pipe to chimney(as recommended by manufacture)making Suitable size hole in brick masonry wall/ RCC wall for passing of pipe to outside and making good disturbed surfaces all as specified and directed.Note: 5 years of replacement warranty on motor and 1 year on product will be deemed included in quoted rates.Make: Glen Model No. CH6062BLAC90 or equivalent of Faber/Sunflame. |
| 135 | TV CABLE:M & L for rigid non-metallic PVC concealed conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed. |
| 136 | M & L for rigid non-metallic PVC concealed conduit of dia 25 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed. |
| 137 | M & L for junction boxes (1 to 4 way), External dia in 20 mm complete all as specified and as directed by the Engineer-in-Charge |
| 138 | M & L for junction boxes (1 to 4 way) external dia in 25 mm complete all as specified and as directed by the Engineer-in-Charge |
| 139 | Supply and fix TV cable co axial complete all as specified and directed. |
| 140 | Supply and fix TV sockets modular type including flush box and moular platescomplete |
| 141 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm girth but not exc 20 cm. |
| 142 | TELEPHONE CABLE :M & L for rigid non-metallic PVC concealed conduit of dia 20 mmexclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., |
| 143 | M & L for junction boxes (1 to 4 way), External dia in 20 mm complete all as specified and as directed |
| 144 | Supply and fix Tele cable electrolytic grade solid annealed copper conductor,jelly field,aluminium foiled and aluminium wire braided one pair complete all as specified and directed. |
| 145 | Supply and fix Tele sockets modular type including flush box and moular platescomplete all as specified and directed. |
| 146 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm girth but not exc 20 cm.complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail