Public Works Department-PWD has published Tender For Providing Service And Accessories For 4 Nos. Chiller Plants Of Hvac System Existing At Shri Lal Bahadur Shastri Govt. Medical College And Hospital Nerchowk. Submission Date for this Tender is 22-06-2023. HVAC Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Descaling of Condenser / chiller only chemical circulation unit Roding chemical circulation leak testing and end cover opening of both end and box up after flushing with fresh water after Roding and brushing of all copper tube. Health check-up of chiller and testing of machine in part load full load checking up of all parameter up to standard mark compressor testing surging of Compressor chiller superheat testing both discharge as well as suction winding temp setting and upload of chiller parameters testing of all circuit control wiring / VFD Preventive maintenance,Routine service of chillers health check-ups guide vane calibration cleaning of machine arc for contactor cleaning and setting up of parameter for healthy operation. |
2 | Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, "C" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole.(Category-A) |
3 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:- Armoured cable 50 sq. mm (3.5 core) |
4 | S/F of Add on Auxiliary Contact blocks suitable for MX front add-on Aux contact block as MX0/6/9/12 having ocde CS94037, complete in all respect to best satisfaction of Engineer in charge. MX 0/6/9/12, CS94037 |
5 | S/F of 3 pole power comtactors type MNX conforns to IS / IEC 60947-4-1 & IEC 60947-4-1 ranging from 9A-650A AC-3 , click fit type construction upto 40A, coil on top design in 95A and above complete in all respect to best satisfaction of Engineer in charge. |
6 | MNX12, 1NO cat no CS94108 |
7 | MNX12, 1NC cat no CS94109 |
8 | Providing of Centrifugal Compressor Synthetic Oil in the existing Chiller Machine installed in HVAC PlantMake Carrier testing and commissioning etc. as required complete in all respect as per entire satisfaction of E-in -charge. |
9 | Servicing and Washing of Cooling and Heating Coil in AHU of Different Capacitycomplete in all respect as per entire satisfaction of Engineer in Charge |