Iims (Govt. Medical College), Palakkad- Setting Up Of Modular Operation Theatres (No. 6,7&8) At Govt. Medical College, Palakkad, Ernakulam-Kerala

Kerala Electrical And Allied Engineering Co Limited-KEL has published Iims (Govt. Medical College), Palakkad- Setting Up Of Modular Operation Theatres (No. 6,7&8) At Govt. Medical College, Palakkad. Submission Date for this Tender is 16-06-2023. Building Work Tenders in Ernakulam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

38097497
Iims (Govt. Medical College), Palakkad- Setting Up Of Modular Operation Theatres (No. 6,7&8) At Govt. Medical College, Palakkad
Open Tender
Indian
Kerala
Ernakulam
16-06-2023

Tender Details

Iims ( Govt. Medical College ) , Palakkad- Setting Up Of Modular Operation Theatres ( No. 6, 7&8 ) At Govt. Medical College, Palakkad

Key Value

Document Fees
INR 8850 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: IIMS (GOVT. MEDICAL COLLEGE), PALAKKAD- SETTING UP OF MODULAR OPERATION THEATRES (NO. 6,7&8) AT GOVT. MEDICAL COLLEGE, PALAKKAD.
Sl. No. Item Description
1CIVIL WORK-OT 06
215.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
315.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
415.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
514.83 : Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
615.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
75.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
85.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
95.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1050.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
1113.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
1211.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
1311.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
148.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
1513.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
1618.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge.External work62.50 mm nominal inner dia pipes
1718.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes
1818.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall25 mm nominal outer dia pipes
19od71510/2023_2024 : ProvidingCores on Slab or beamless than 200 mm of size from 100 to 180 mm diameter including cost and conveyance of all materials, including removal of debrises all labour charges, all taxes, lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
20ELECTRICAL WORK- OT 06
212.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
221.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
231.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
241.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
251.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
262.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
271.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
281.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
291.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
302.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
312.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
322.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
3390.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
349.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
3590.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
369.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
371.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
38od71514/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. 63A 10KA TP MCB (C curve)
39od71519/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required.40A 10KA TP MCB (C curve)
40od71520/2023_2024 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required
41od71521/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.20W LED Tube light
42od71522/2023_2024 : 'Supplying and fixing of following ways, vertical type, 415 V, TPN, sheet steel, MCB distribution board conforming to IEC 61439-3 (IP 43) on surface / in recess, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, neutral bus bar, earth bar, provision for fixing 4-pole MCCB as incomer, din bar for mounting MCBs (But without MCBs and incomer), prefitted masking sheet, interconnections etc as required.6 way (8+12) double door TPN VDB.
43od71523/2023_2024 : " Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps"
44od71518/2023_2024 : Providing and fixing 4.00 mm (8 SWG ) dia copper wire on surface or in recess for loop earthing as required.
45od71525/2023_2024 : 2.14LMRSupply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.2'x2'LED Square Panel downlight.(36W)
46od71526/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.12W LED Downlight(Round)
47od71527/2023_2024 : Supplying and fixing of following sizes of flexible conduit along with accessories in surface/recessas required.(16/ 20mm.)
48od71528/2023_2024 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
49BIO MEDICAL- OT 06
50od71497/2023_2024 : Sliding Door: Automated Single Leaf Sliding Door 1800 mm HPLAutomated Single Leaf Sliding Door 1800 x 2100 mm. Sliding door: The sliding door system size of single leaf according to the Operating room size the requirements in accordance with the Machine Directive 2006/42/EU, DIN 18650 and DIN / EN 16005 and is made up of the following main components:Automatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments. It should have a palm sensor for half opening and foot switch for full opening patient entry. Sliding door substructure: The sliding door substructure forms the transition between wall and door. It connects the running gear to the wall and ensures increased reinforcement, for profile walls, in the area of the sliding door. Door frame: The door frames are manufactured from 55/highpressure Aluminum frame. The one- leaf sliding door is designed with a ramp frame in order to prevent a shearing point. The closing edgesare fittedwithsurroundinggreysealprofiles(RAL 7016). Thedoorframeisfittedwith fillerthat is adhered to the entire surface. Door leaf: The door leaf has a thickness of minimum 40 mm. It is made up of a High Pressure Laminatefullygluedtubular chipboard or hard foam panel.Thehandle is astainless steel bow-type handle on both sides. The door should have a viewing glass of minimum 300 x 300 with motorized blinds.Runninggear,manualorElectrictherunning gearismadeupofanaluminumprofilewhich carries the functional parts and a rail profile for the roller wagon. The castor carriages are fitted with ball-bearing mounted plastic castors and connect the running gear to the door leaf. The fold- out casing of the runninggear is made from powder-coated CrNi steel and may be locked with a holding bar for maintenance work. Sliding Door shall have certificate in accordance with International standards e.g.: CE/TUV etc. Manufacturer: METAFLEX/DRAGER
51od71499/2023_2024 : OT Control Panel: Touch Screen Control Panel to control Humidity, Temperature, Gas Alarm, Clock, Lighting Control. Control panel should have minimum 22” touch screen within the theatre and will be located on theatre wall. The time elapsed digital clock and real time digital clocks shall have high brightness characters, the medical gas alarm will indicate High and Low gas pressure for each gas service present in the operating theatre and will have an audible buzzer with mute facility. The medical gas alarms will be connected to locai pressure switches located downstream of the last isolation valves.Each control panel should have display for Time elapse clock, Standard Clock, Temperature and Humidity, Clean room luminaries, Telephone, Medical Gas Alarms and HEPA filter status. We should be able to change the temperature and humidity of the OT as per daily / case to case basis requirement. This AC temperature control should be available either on the control panel or as a separate panel on the wall inside the operating room. The temperature and humidity sensing should be done from as near the operating table area as possible.Manufacturer: GETTINGE/DRAGER/DR. MACH
52od71501/2023_2024 : Air Extraction: Exhaust grills with filtersThe exhaust grills should be connected to the air extraction cabinets placed at the 4 Corners of the OR. Each corner grill should be made of SS 304 duly powder coated of the same colour shade as wall pannel. The installation should be flush mounted to the wall panel. The return air grills should have a fluff filters. Minimum size of the grill should be 450 x 450 mm.
53od71503/2023_2024 : Laminar Air Flow: SS Laminar Plenum Box with HEPA Filters & CG Screen 2400 x 2400 mm.Plan air Ceiling constructed out of SS304 of size 2400 x 2400 mm having 8 nos of HEPA Filters. Sufficient number of pre-filters to be provided that would maintain the efficiency of HEPA filters. The HEPA filters should have dust spot efficiency of 99.97% for 0.3 micron particles. Air diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air. Number of air changes should be such that Clean room classification can be maintained at Class 100, as per ISO 14644.
54od71504/2023_2024 : Flooring: Conductive Flooring: Electro Static Discharge (ESD) Control Flooring is a conductive flexible homogeneous vinyl floor covering available in sheet form. The 2 mm homogeneous material incorporates carbon encapsulated granules throughout its full thickness and has a conductive backing to ensure optimal and consistent conductive properties throughout its full life expectancy. It has permanent antistatic properties (< 20 V).It acts as a continuous conductive 5.104 ≤ Rt ≤ 106 (EN 1081) and complies with EN 649. The product is non-reactive to residual indentation with a value ≤ 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-sl fire resistance. The product is non-emissive of volatile organic compounds with <10 µg/m3 (TVOC after 28 days ISO 16000-6).
55od71506/2023_2024 : Ceiling Panels: Ceiling element steel size of600 x 1200mmsheetMaterial no. 1.0347should be in accordance with DIN /EN 10152.The ceiling system is made up of removable ceiling cassette chamfered all round, fromgalvanized/steelsheetwithathicknessof0.7 mm- 1.0mm. Thevisiblesideis coatedwith a white polyurethane powder-based finish (RAL9016). For restructuring purposes these ceiling cassettes can simply be disassembled and then reinstalled.The ceiling cassettes are secured by means of a self-locking system onto clamp rails and by means ofseal-tightassemblyinlongitudinaldirection.The ceiling cassettesareprovidedwith circumferential sealing. The joint is provided in transverse directionwithan HTV silicone joint profilefor opticalcontinuousclosure.Thesuspensionheightoftheceilingcanbeadjustedby suspending means with tension springs.Itshouldbe similarly prefabricatedinthefactory andfulfil the requirements offlexibility such that itshould be possible to remove the individual panels individually with the exception of the edge panels. It should be secured with a locking system and perfect sealing. The joints should be providedwith asiliconesealingforacontinuousclosure.Itshouldbestableandnonslipafter adjustment. Allsides of the panels should have folded edges.
56od71507/2023_2024 : Wall Paneling- Stainless Steel Prefabricated Walls- Single /double part Wall panel elements are made up of powder-coated CrNi steel Material no. 1.4301 with a minimum thickness of 0.8 mm to 1.0 mm backed by 15 - 18mm Gypsum Plasterboard . It should be tested & certified according to EN / DIN 10088-3. The wall panels are chamfered all round and should have 18 mm Fire rated Gypsum plasterboard glued to the entire rear side. The total distance between the inside and outside surfaces of the operating room should be variable to suit the layout, but should be sufficient for the flush mounting of equipment. The cavity between the inner and outer walls should be left with minimum obstructions for the possible addition of equipment at a later date and to enable services, pipes, conduits etc., to be run within the cavity, Sound insulation value 47- 64 Rw [dB].The individual wall panels should be made of single / double sheet with the width of 900-1200mm. The individual wall panels should be attached to each other with removable clamps or screws or an equivalent fastening system which will allow fast installation as well as removal for service. Welding of wall panels on site will not be permitted. The joints should be covered with removable and reusable silicone Gasket such that there is continuity in walls visually. Liquid silicone should not be used for sealing.All wall-mounted equipment should be flush mounted. The wall panel design andconstruction should allow for the installation and support of all equipment and the provision of openings required for installations, without affecting rigidity and strength.Joint profile between the wall elements HTN silicone gasket with antimicrobial properties.There should not be any sharp edges and corners should be smoothened. A shell type substructure should be designed as a non-load bearing wall.Once fixed they have to provide complete hygienic sealing. The prefabricated wall panels should be coated at the factory itself. It should have high heat stability and it should be highly durable against mopping. The coating should be done at the factory of origin of the panel and it should not be done at site. Shade of coating should be confirmed with the user department. Resistance against recommended hospital cleaning and disinfection agents must be ensured. Certification from regulatory authorities is essential.The mounting of the wall elements to the substructure is carried out via clamps that are attached to the wall elements and screwed to the support. The wall elements, when fixed, provide a hermetic and hygienic circumferential and sealed connection. The joint between the wall elements is closed with a removable joint profile made of colour coded HTV silicone.Antibacterial coating: Mixed powder paint on epoxy-polyester resin basis, in accordance withDIN67530, silk matte, gloss level 60°, layer thickness 90 - 120 pm. Antibacterial to be powder coating on SS test certificate should be duly submittd.Sound insulation: Without any additional measures the sound insulation values have to be aminimum of 45dB. Test reports of sound insulation will be required.Fire protection: The wall system (panels and substructure) should be made of non-flammable material. No dangerous concentrations of gases should be produced in an event of fire. It should confirm to Class A2-S1,d0.Substructure:The profile with connection to the raw ceiling supports are made of galvanized square steel pipe with min 2 mm thickness.The floor rails comprise profiled, 1.5 mm galvanised steel plates. The floor rails aremounted using clamp plates and screws with dowels into screed or threaded rods with dowels into the unfinished floor.Ceiling railThe ceiling rail is made of white-painted (RAL9016) aluminium extruded profile and acts asa mount for the ceiling cassette which is coordinated in colour. The upper wall element and the ceiling cassette are inserted into the opening of the ceiling rail and sealed.
57od71500/2023_2024 : OT LIGHT:Double domeTechnical Specifications for Double dome LED Surgical light with monitor.The following technical specifications should be considered as mandatory features: If any point does not fit, offer will not be evaluated.• Equipment should be CE marked / BIS• The spare parts availability must be 10 years after the date of the installation• The manufacturer must have at least 15 years of experience and expertise in the manufacture of surgical light and a minimum of 5 years in the use of LEDs in this product• Light should be provided with frontal arms for low ceiling height• The LED’s must be of a single color only for long term maintenance and ease of replacement.• Should have a average radiant energy of the lights should be less than 3.9 mW/m2• Double dome light unit incorporating latest LED technology, with shadow less operating light field should be offered.• Should have continuous LUX intensity of maximum 160,000• Should have HECOL technology to produce light beams for perfect visualization on surface as well as in deep cavities.• Central illuminance at D10 and D50 >130,000 lux• Should have ambient light for endoscopy.• Should have adjustable color temp, from 3900°K to 4500°K• Depth of illumination L1+L2 (60%) 500 mm• Depth of illumination L1+L2 (20%) 1050 mm• larger field diameter 25 cm (D10)• Lifetime of the LED 60 000 hours without loss of efficiency.• Color rendering index Ra>95• Color rendering index R9>90• Sterile control of settings (Intensity or Diameter or Color Temp.) for surgical team• Should have a management system that ensure constant quality of light (Intensity, Color rendering index, Color Temp.) throughout the length of the surgery.• Should have stable illumination through the life period of the light.• Excellent shadow dilution: remaining illumination should be at least 60,000Lux in the worst case.• Protection degree against dust and liquid projections IP44• The lights should be cool lights and temperature at the surgical field should not increase more than 1 degree at 1.60,000 lux with regards to the temperature outside the surgicalfield. If demanded, vendor will have to prove the same during the lifetime of the equipment failing which downtime penalty clause will be applicable till the same is adhered to • Adjustable field diameter without any mechanical movementManufacturer: GETTINGE/ CARLSTORZ/DRAGER/DR. MACH
58od71502/2023_2024 : X-ray Viewer:X-Ray View box -LED Dual Screen 1000x400mmwith dipping function with ON/OFF button.
59od71505/2023_2024 : Writing Board: Size: about 1000mm x 700mmx 60mm deep Writing board should be made of ceramic having Magnetic properties and should be flushed to the wall of the operation room.
60od71509/2023_2024 : Cleanroom Ambient Lights: LED Peripheral Light cum clean room (OT) luminaries confirms to EN Electrical certifications Should give a total of 1500lx luminescence in operating area and 1000 lx in other peripheral areas with steeples, flicker less dimming control down to 5% level. There shall be two minimum independent circuits. They should be surface-mounted and recessed lights. Framed light cover should be made of highly-resistant and disinfectant - consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly-specular reflectors, cumulative reflection coated, Body should consist of sheet steel with mechanical and electrical removable carrier equipment Protection IP 65. The colour temperature of the lights should be 4000k minimum.
61od71511/2023_2024 : Cabinet:Size 2100mm x 1200mm x 400mm deep. The storage unit made from 1.5mm of stainless steel of SS304 grade. The doors shutter of the storage cabinet should have glass, should be installed on the storage units with the help of fittings allowing an opening allowance of at least 160. The storage unit should be divided in 2 equal parts and each part should have individual doors with stopper system.Each part should be provided with glass racks as per user department, and should be adjustable type.
62od71515/2023_2024 : "Double Station Surgical Scrub Sink. (Fully Automatic0* Completely Made of Stainless Steel 304 Grade Mat # 4 Finish Sheets & Tubes.* Perforated Drain Board.* Two No of Sensor Operated Water Taps.* Two No of Knee Operated Water Taps.* Two No of Sensor Operated Soap Dispenser.* One No of Lbow Operated Soap Dispenser.* Sink Panal SS Black Powder Cotting Model.* Water Flow is Shower Mode.* Wall Hanging Bracket.* Soap Tank Capacity 5Ltr.* Curved Joints to Avoid Microbial Deposition and Growth, Ensuring Perfect Hygiene and Easy of Cleaning.The Hospital Pattern (HTM64) Trough has fully Radius Internal Corners for Easy of Cleaning and Hygiene.* The Unit is Wall Mounted.* Welded Fabrication in Tungston Gas."
63od71513/2023_2024 : OT Pendent [Anesthesia]: Pendant Shall Conform to DIN EN ISO11197:2005.Each Ceiling Suspended Pendant Systemhave: Horizontal Double Arm Combination will be 900mm- 600 mm extending to total 1500mm.The swivel arm, carrying the supply column,maximum degree of rotary motion 300” in the horizontal plane and able to hold a weight of about 200 kg. The distribution column of at least 800mmin height. Minimum clearance from finished floor to bottom of pendant must be about 600-700 mm, 3 platforms of about 40cms x 50cms. Itmust allow gap of up to 25cms. Must include one drawer mechanism. Each platform must have weight bearing capacity of more than 50 Kg Each. Must have dual IV rod stand with a capacity of about 20 Kg with infusion management system With 2 vertical tubes, for mounting of infusion and syringe pumps. The following medical gas outlets must be provided on the back of the service head. It shall be DIN Standard/EN / HTM / NFPA standard & CE marked / UL Listed.i. O2 - 2 Nosii. Nitrous Oxide - 1 Noiii.Vacuum -2Nosiv. Medical Air- 1 Nov. AGSS (Venturi Type) -1 No. All Gas Outlets must come fitted from the factory.8 electrical sockets should be provided on the service head and UPS power (all 6/16Amp).These must be compatible to the Indian plugs. Must have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height. The pendant must have a Friction or Pneumatic braking system. The pendant must have a safety mechanism with internal isolation between gas and electrical services. All Gas Outlets must come fitted from the factory.8 electrical sockets should be provided on the service head and UPS power (all 6/16Amp).These must be compatible to the Indian plugs. Must have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height. The pendant must have a Friction or Pneumatic braking system. The pendant must have a safety mechanism with internal isolation between gas and electrical services. Manufacturer: GETTINGE/DRAGER/DR. MACH
64od71517/2023_2024 : OT Pendent [Surgery]: Pendant Shall Conform to DIN / EN ISO 11197:2005.Each Ceiling Suspended Pendant System should have:Horizontal Double Arm Combination will be 900mm- 600 mm extending to total 1500mm.The2swivelarms,carryingthesupplycolumn,shouldhavethemaximumdegreeofrotary motion 300* in the horizontal plane and should be able to hold a weight of about 200 kg.The distribution column should be at least 800 -1200 mm in height.Minimum clearance from finished floor to bottom of pendant should be about 600-700 mm.Should have 3 platforms of about 40cms x 50cms. It should allow gap of up to 75cms.Each platform should have weight bearing capacity of more than 50 Kg Each.The following medical gas outlets should be provided on the back of the service head. It shall be DIN Standard / HTM standard / NFPA standard with CEmarked / UL Listed.i. O2 -2Noiii.Vacuum -2 Nosiv. Compressed air supply - 1 Nov. Medical Air- 1 novi. Motor Air 7 Bar - 1 Novii.CO2 - 1No. All Gas Outlets should come fitted from the factory.10 electrical sockets should be provided on the service head (6 on each side). These should be compatible to the Indian plugs. Should have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height.The pendant should have a Friction or Pneumatic braking system.The pendant should have a safety mechanism with internal isolation between gas and electrical services. The pendant should have a provision to mount 32" monitor with swivelling up-down/right-left function.Mainmaterialused shouldbe ofhigh strength aluminum alloy, withasealeddesign, surface having antimicrobial and antifungal coating. Resistance against common hospital or manufactured recommended cleaning and disinfection agents must be ensured. It shall be CE marked.The Medical Gas Outlets Points on the pendants should be duly CE marked. It should have Integral check valve, should allow removal of the housing and socket assemblies formaintenance without closing down the entire pipeline and each outlet should be individually tested. Each of the gas specific components must have the gas service engraved onto it to ensure safety and compliance with standard.Should have safety features which eliminate the risk of connecting a socket assembly of one gas to the terminal block of another, either during installation or maintenance. All Gas Outlets should come fitted from the factory.10 electrical sockets should be provided on the service head (6 on each side). These should be compatible to the Indian plugs. Should have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height.The pendant should have a Friction or Pneumatic braking system.The pendant should have a safety mechanism with internal isolation between gas and electrical services. The pendant should have a provision to mount 32" monitor with swivelling up-down/right-left function.Mainmaterialused shouldbe ofhigh strength aluminum alloy, withasealeddesign, surface having antimicrobial and antifungal coating. Resistance against common hospital or manufactured recommended cleaning and disinfection agents must be ensured. It shall be CE marked.The Medical Gas Outlets Points on the pendants should be duly CE marked. It should have Integral check valve, should allow removal of the housing and socket assemblies formaintenance without closing down the entire pipeline and each outlet should be individually tested. Each of the gas specific components must have the gas service engraved onto it to ensure safety and compliance with standard.Should have safety features which eliminate the risk of connecting a socket assembly of one gas to the terminal block of another, either during installation or maintenance. Manufacturer: GETTINGE/DRAGER/DR. MACH
65HVAC- OT 06
66od71496/2023_2024 : Supplying and fixing of following thickness closed cell Nitrile rubber (Class “O”) insulation with anti microbial protection .13 mm
67od71498/2023_2024 : "ALUMINIUM DUCTING AND INSULATION: Supply, installation balancing and commisnioning of Aluminium rectangularducting as per approved drawings & specification of following sheet thickness. Thickness 22 Gauge"
68CIVIL WORK- OT 07
6915.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
7015.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
7115.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
7214.83 : Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
7315.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
745.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
755.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
765.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
7750.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
7813.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
7911.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
8011.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
818.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
8213.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
83ELECTRICAL WORK- OT 07
842.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
851.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
861.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
871.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
881.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
892.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
901.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
911.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
921.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
932.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
942.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
952.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
9690.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
979.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
9890.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
999.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
1001.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
101od71514/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. 63A 10KA TP MCB (C curve)
102od71519/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required.40A 10KA TP MCB (C curve)
103od71520/2023_2024 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required
104od71518/2023_2024 : Providing and fixing 4.00 mm (8 SWG ) dia copper wire on surface or in recess for loop earthing as required.
105od71521/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.20W LED Tube light
106od71522/2023_2024 : 'Supplying and fixing of following ways, vertical type, 415 V, TPN, sheet steel, MCB distribution board conforming to IEC 61439-3 (IP 43) on surface / in recess, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, neutral bus bar, earth bar, provision for fixing 4-pole MCCB as incomer, din bar for mounting MCBs (But without MCBs and incomer), prefitted masking sheet, interconnections etc as required.6 way (8+12) double door TPN VDB.
107od71524/2023_2024 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
108od71525/2023_2024 : 2.14LMRSupply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.2'x2'LED Square Panel downlight.(36W)
109od71526/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.12W LED Downlight(Round)
110od71527/2023_2024 : Supplying and fixing of following sizes of flexible conduit along with accessories in surface/recessas required.(16/ 20mm.)
111od71528/2023_2024 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
112BIO MEDICAL- OT 07
113od71500/2023_2024 : OT LIGHT:Double domeTechnical Specifications for Double dome LED Surgical light with monitor.The following technical specifications should be considered as mandatory features: If any point does not fit, offer will not be evaluated.• Equipment should be CE marked / BIS• The spare parts availability must be 10 years after the date of the installation• The manufacturer must have at least 15 years of experience and expertise in the manufacture of surgical light and a minimum of 5 years in the use of LEDs in this product• Light should be provided with frontal arms for low ceiling height• The LED’s must be of a single color only for long term maintenance and ease of replacement.• Should have a average radiant energy of the lights should be less than 3.9 mW/m2• Double dome light unit incorporating latest LED technology, with shadow less operating light field should be offered.• Should have continuous LUX intensity of maximum 160,000• Should have HECOL technology to produce light beams for perfect visualization on surface as well as in deep cavities.• Central illuminance at D10 and D50 >130,000 lux• Should have ambient light for endoscopy.• Should have adjustable color temp, from 3900°K to 4500°K• Depth of illumination L1+L2 (60%) 500 mm• Depth of illumination L1+L2 (20%) 1050 mm• larger field diameter 25 cm (D10)• Lifetime of the LED 60 000 hours without loss of efficiency.• Color rendering index Ra>95• Color rendering index R9>90• Sterile control of settings (Intensity or Diameter or Color Temp.) for surgical team• Should have a management system that ensure constant quality of light (Intensity, Color rendering index, Color Temp.) throughout the length of the surgery.• Should have stable illumination through the life period of the light.• Excellent shadow dilution: remaining illumination should be at least 60,000Lux in the worst case.• Protection degree against dust and liquid projections IP44• The lights should be cool lights and temperature at the surgical field should not increase more than 1 degree at 1.60,000 lux with regards to the temperature outside the surgicalfield. If demanded, vendor will have to prove the same during the lifetime of the equipment failing which downtime penalty clause will be applicable till the same is adhered to • Adjustable field diameter without any mechanical movementManufacturer: GETTINGE/ CARLSTORZ/DRAGER/DR. MACH
114od71502/2023_2024 : X-ray Viewer:X-Ray View box -LED Dual Screen 1000x400mmwith dipping function with ON/OFF button.
115od71505/2023_2024 : Writing Board: Size: about 1000mm x 700mmx 60mm deep Writing board should be made of ceramic having Magnetic properties and should be flushed to the wall of the operation room.
116od71497/2023_2024 : Sliding Door: Automated Single Leaf Sliding Door 1800 mm HPLAutomated Single Leaf Sliding Door 1800 x 2100 mm. Sliding door: The sliding door system size of single leaf according to the Operating room size the requirements in accordance with the Machine Directive 2006/42/EU, DIN 18650 and DIN / EN 16005 and is made up of the following main components:Automatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments. It should have a palm sensor for half opening and foot switch for full opening patient entry. Sliding door substructure: The sliding door substructure forms the transition between wall and door. It connects the running gear to the wall and ensures increased reinforcement, for profile walls, in the area of the sliding door. Door frame: The door frames are manufactured from 55/highpressure Aluminum frame. The one- leaf sliding door is designed with a ramp frame in order to prevent a shearing point. The closing edgesare fittedwithsurroundinggreysealprofiles(RAL 7016). Thedoorframeisfittedwith fillerthat is adhered to the entire surface. Door leaf: The door leaf has a thickness of minimum 40 mm. It is made up of a High Pressure Laminatefullygluedtubular chipboard or hard foam panel.Thehandle is astainless steel bow-type handle on both sides. The door should have a viewing glass of minimum 300 x 300 with motorized blinds.Runninggear,manualorElectrictherunning gearismadeupofanaluminumprofilewhich carries the functional parts and a rail profile for the roller wagon. The castor carriages are fitted with ball-bearing mounted plastic castors and connect the running gear to the door leaf. The fold- out casing of the runninggear is made from powder-coated CrNi steel and may be locked with a holding bar for maintenance work. Sliding Door shall have certificate in accordance with International standards e.g.: CE/TUV etc. Manufacturer: METAFLEX/DRAGER
117od71499/2023_2024 : OT Control Panel: Touch Screen Control Panel to control Humidity, Temperature, Gas Alarm, Clock, Lighting Control. Control panel should have minimum 22” touch screen within the theatre and will be located on theatre wall. The time elapsed digital clock and real time digital clocks shall have high brightness characters, the medical gas alarm will indicate High and Low gas pressure for each gas service present in the operating theatre and will have an audible buzzer with mute facility. The medical gas alarms will be connected to locai pressure switches located downstream of the last isolation valves.Each control panel should have display for Time elapse clock, Standard Clock, Temperature and Humidity, Clean room luminaries, Telephone, Medical Gas Alarms and HEPA filter status. We should be able to change the temperature and humidity of the OT as per daily / case to case basis requirement. This AC temperature control should be available either on the control panel or as a separate panel on the wall inside the operating room. The temperature and humidity sensing should be done from as near the operating table area as possible.Manufacturer: GETTINGE/DRAGER/DR. MACH
118od71501/2023_2024 : Air Extraction: Exhaust grills with filtersThe exhaust grills should be connected to the air extraction cabinets placed at the 4 Corners of the OR. Each corner grill should be made of SS 304 duly powder coated of the same colour shade as wall pannel. The installation should be flush mounted to the wall panel. The return air grills should have a fluff filters. Minimum size of the grill should be 450 x 450 mm.
119od71503/2023_2024 : Laminar Air Flow: SS Laminar Plenum Box with HEPA Filters & CG Screen 2400 x 2400 mm.Plan air Ceiling constructed out of SS304 of size 2400 x 2400 mm having 8 nos of HEPA Filters. Sufficient number of pre-filters to be provided that would maintain the efficiency of HEPA filters. The HEPA filters should have dust spot efficiency of 99.97% for 0.3 micron particles. Air diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air. Number of air changes should be such that Clean room classification can be maintained at Class 100, as per ISO 14644.
120od71504/2023_2024 : Flooring: Conductive Flooring: Electro Static Discharge (ESD) Control Flooring is a conductive flexible homogeneous vinyl floor covering available in sheet form. The 2 mm homogeneous material incorporates carbon encapsulated granules throughout its full thickness and has a conductive backing to ensure optimal and consistent conductive properties throughout its full life expectancy. It has permanent antistatic properties (< 20 V).It acts as a continuous conductive 5.104 ≤ Rt ≤ 106 (EN 1081) and complies with EN 649. The product is non-reactive to residual indentation with a value ≤ 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-sl fire resistance. The product is non-emissive of volatile organic compounds with <10 µg/m3 (TVOC after 28 days ISO 16000-6).
121od71506/2023_2024 : Ceiling Panels: Ceiling element steel size of600 x 1200mmsheetMaterial no. 1.0347should be in accordance with DIN /EN 10152.The ceiling system is made up of removable ceiling cassette chamfered all round, fromgalvanized/steelsheetwithathicknessof0.7 mm- 1.0mm. Thevisiblesideis coatedwith a white polyurethane powder-based finish (RAL9016). For restructuring purposes these ceiling cassettes can simply be disassembled and then reinstalled.The ceiling cassettes are secured by means of a self-locking system onto clamp rails and by means ofseal-tightassemblyinlongitudinaldirection.The ceiling cassettesareprovidedwith circumferential sealing. The joint is provided in transverse directionwithan HTV silicone joint profilefor opticalcontinuousclosure.Thesuspensionheightoftheceilingcanbeadjustedby suspending means with tension springs.Itshouldbe similarly prefabricatedinthefactory andfulfil the requirements offlexibility such that itshould be possible to remove the individual panels individually with the exception of the edge panels. It should be secured with a locking system and perfect sealing. The joints should be providedwith asiliconesealingforacontinuousclosure.Itshouldbestableandnonslipafter adjustment. Allsides of the panels should have folded edges.
122od71507/2023_2024 : Wall Paneling- Stainless Steel Prefabricated Walls- Single /double part Wall panel elements are made up of powder-coated CrNi steel Material no. 1.4301 with a minimum thickness of 0.8 mm to 1.0 mm backed by 15 - 18mm Gypsum Plasterboard . It should be tested & certified according to EN / DIN 10088-3. The wall panels are chamfered all round and should have 18 mm Fire rated Gypsum plasterboard glued to the entire rear side. The total distance between the inside and outside surfaces of the operating room should be variable to suit the layout, but should be sufficient for the flush mounting of equipment. The cavity between the inner and outer walls should be left with minimum obstructions for the possible addition of equipment at a later date and to enable services, pipes, conduits etc., to be run within the cavity, Sound insulation value 47- 64 Rw [dB].The individual wall panels should be made of single / double sheet with the width of 900-1200mm. The individual wall panels should be attached to each other with removable clamps or screws or an equivalent fastening system which will allow fast installation as well as removal for service. Welding of wall panels on site will not be permitted. The joints should be covered with removable and reusable silicone Gasket such that there is continuity in walls visually. Liquid silicone should not be used for sealing.All wall-mounted equipment should be flush mounted. The wall panel design andconstruction should allow for the installation and support of all equipment and the provision of openings required for installations, without affecting rigidity and strength.Joint profile between the wall elements HTN silicone gasket with antimicrobial properties.There should not be any sharp edges and corners should be smoothened. A shell type substructure should be designed as a non-load bearing wall.Once fixed they have to provide complete hygienic sealing. The prefabricated wall panels should be coated at the factory itself. It should have high heat stability and it should be highly durable against mopping. The coating should be done at the factory of origin of the panel and it should not be done at site. Shade of coating should be confirmed with the user department. Resistance against recommended hospital cleaning and disinfection agents must be ensured. Certification from regulatory authorities is essential.The mounting of the wall elements to the substructure is carried out via clamps that are attached to the wall elements and screwed to the support. The wall elements, when fixed, provide a hermetic and hygienic circumferential and sealed connection. The joint between the wall elements is closed with a removable joint profile made of colour coded HTV silicone.Antibacterial coating: Mixed powder paint on epoxy-polyester resin basis, in accordance withDIN67530, silk matte, gloss level 60°, layer thickness 90 - 120 pm. Antibacterial to be powder coating on SS test certificate should be duly submittd.Sound insulation: Without any additional measures the sound insulation values have to be aminimum of 45dB. Test reports of sound insulation will be required.Fire protection: The wall system (panels and substructure) should be made of non-flammable material. No dangerous concentrations of gases should be produced in an event of fire. It should confirm to Class A2-S1,d0.Substructure:The profile with connection to the raw ceiling supports are made of galvanized square steel pipe with min 2 mm thickness.The floor rails comprise profiled, 1.5 mm galvanised steel plates. The floor rails aremounted using clamp plates and screws with dowels into screed or threaded rods with dowels into the unfinished floor.Ceiling railThe ceiling rail is made of white-painted (RAL9016) aluminium extruded profile and acts asa mount for the ceiling cassette which is coordinated in colour. The upper wall element and the ceiling cassette are inserted into the opening of the ceiling rail and sealed.
123od71509/2023_2024 : Cleanroom Ambient Lights: LED Peripheral Light cum clean room (OT) luminaries confirms to EN Electrical certifications Should give a total of 1500lx luminescence in operating area and 1000 lx in other peripheral areas with steeples, flicker less dimming control down to 5% level. There shall be two minimum independent circuits. They should be surface-mounted and recessed lights. Framed light cover should be made of highly-resistant and disinfectant - consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly-specular reflectors, cumulative reflection coated, Body should consist of sheet steel with mechanical and electrical removable carrier equipment Protection IP 65. The colour temperature of the lights should be 4000k minimum.
124od71511/2023_2024 : Cabinet:Size 2100mm x 1200mm x 400mm deep. The storage unit made from 1.5mm of stainless steel of SS304 grade. The doors shutter of the storage cabinet should have glass, should be installed on the storage units with the help of fittings allowing an opening allowance of at least 160. The storage unit should be divided in 2 equal parts and each part should have individual doors with stopper system.Each part should be provided with glass racks as per user department, and should be adjustable type.
125od71513/2023_2024 : OT Pendent [Anesthesia]: Pendant Shall Conform to DIN EN ISO11197:2005.Each Ceiling Suspended Pendant Systemhave: Horizontal Double Arm Combination will be 900mm- 600 mm extending to total 1500mm.The swivel arm, carrying the supply column,maximum degree of rotary motion 300” in the horizontal plane and able to hold a weight of about 200 kg. The distribution column of at least 800mmin height. Minimum clearance from finished floor to bottom of pendant must be about 600-700 mm, 3 platforms of about 40cms x 50cms. Itmust allow gap of up to 25cms. Must include one drawer mechanism. Each platform must have weight bearing capacity of more than 50 Kg Each. Must have dual IV rod stand with a capacity of about 20 Kg with infusion management system With 2 vertical tubes, for mounting of infusion and syringe pumps. The following medical gas outlets must be provided on the back of the service head. It shall be DIN Standard/EN / HTM / NFPA standard & CE marked / UL Listed.i. O2 - 2 Nosii. Nitrous Oxide - 1 Noiii.Vacuum -2Nosiv. Medical Air- 1 Nov. AGSS (Venturi Type) -1 No. All Gas Outlets must come fitted from the factory.8 electrical sockets should be provided on the service head and UPS power (all 6/16Amp).These must be compatible to the Indian plugs. Must have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height. The pendant must have a Friction or Pneumatic braking system. The pendant must have a safety mechanism with internal isolation between gas and electrical services. All Gas Outlets must come fitted from the factory.8 electrical sockets should be provided on the service head and UPS power (all 6/16Amp).These must be compatible to the Indian plugs. Must have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height. The pendant must have a Friction or Pneumatic braking system. The pendant must have a safety mechanism with internal isolation between gas and electrical services. Manufacturer: GETTINGE/DRAGER/DR. MACH
126od71517/2023_2024 : OT Pendent [Surgery]: Pendant Shall Conform to DIN / EN ISO 11197:2005.Each Ceiling Suspended Pendant System should have:Horizontal Double Arm Combination will be 900mm- 600 mm extending to total 1500mm.The2swivelarms,carryingthesupplycolumn,shouldhavethemaximumdegreeofrotary motion 300* in the horizontal plane and should be able to hold a weight of about 200 kg.The distribution column should be at least 800 -1200 mm in height.Minimum clearance from finished floor to bottom of pendant should be about 600-700 mm.Should have 3 platforms of about 40cms x 50cms. It should allow gap of up to 75cms.Each platform should have weight bearing capacity of more than 50 Kg Each.The following medical gas outlets should be provided on the back of the service head. It shall be DIN Standard / HTM standard / NFPA standard with CEmarked / UL Listed.i. O2 -2Noiii.Vacuum -2 Nosiv. Compressed air supply - 1 Nov. Medical Air- 1 novi. Motor Air 7 Bar - 1 Novii.CO2 - 1No. All Gas Outlets should come fitted from the factory.10 electrical sockets should be provided on the service head (6 on each side). These should be compatible to the Indian plugs. Should have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height.The pendant should have a Friction or Pneumatic braking system.The pendant should have a safety mechanism with internal isolation between gas and electrical services. The pendant should have a provision to mount 32" monitor with swivelling up-down/right-left function.Mainmaterialused shouldbe ofhigh strength aluminum alloy, withasealeddesign, surface having antimicrobial and antifungal coating. Resistance against common hospital or manufactured recommended cleaning and disinfection agents must be ensured. It shall be CE marked.The Medical Gas Outlets Points on the pendants should be duly CE marked. It should have Integral check valve, should allow removal of the housing and socket assemblies formaintenance without closing down the entire pipeline and each outlet should be individually tested. Each of the gas specific components must have the gas service engraved onto it to ensure safety and compliance with standard.Should have safety features which eliminate the risk of connecting a socket assembly of one gas to the terminal block of another, either during installation or maintenance. All Gas Outlets should come fitted from the factory.10 electrical sockets should be provided on the service head (6 on each side). These should be compatible to the Indian plugs. Should have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height.The pendant should have a Friction or Pneumatic braking system.The pendant should have a safety mechanism with internal isolation between gas and electrical services. The pendant should have a provision to mount 32" monitor with swivelling up-down/right-left function.Mainmaterialused shouldbe ofhigh strength aluminum alloy, withasealeddesign, surface having antimicrobial and antifungal coating. Resistance against common hospital or manufactured recommended cleaning and disinfection agents must be ensured. It shall be CE marked.The Medical Gas Outlets Points on the pendants should be duly CE marked. It should have Integral check valve, should allow removal of the housing and socket assemblies formaintenance without closing down the entire pipeline and each outlet should be individually tested. Each of the gas specific components must have the gas service engraved onto it to ensure safety and compliance with standard.Should have safety features which eliminate the risk of connecting a socket assembly of one gas to the terminal block of another, either during installation or maintenance. Manufacturer: GETTINGE/DRAGER/DR. MACH
127HVAC- OT 07
128od71496/2023_2024 : Supplying and fixing of following thickness closed cell Nitrile rubber (Class “O”) insulation with anti microbial protection .13 mm
129od71498/2023_2024 : "ALUMINIUM DUCTING AND INSULATION: Supply, installation balancing and commisnioning of Aluminium rectangularducting as per approved drawings & specification of following sheet thickness. Thickness 22 Gauge"
130CIVIL WORK- OT 08
13115.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
1325.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
1335.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
1345.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13550.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13650.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in: CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
13713.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
1388.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13913.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
14013.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
14118.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge.External work62.50 mm nominal inner dia pipes
14218.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes
14318.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall25 mm nominal outer dia pipes
144od71508/2023_2024 : Providing and laying Vinyl flooring 2mm thickness Non-Antistatic including cost and conveyance of all materials and labour charges etc. complete
145od71510/2023_2024 : ProvidingCores on Slab or beamless than 200 mm of size from 100 to 180 mm diameter including cost and conveyance of all materials, including removal of debrises all labour charges, all taxes, lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
146ELECTRICAL WORK- OT 08
1472.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1481.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1491.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1501.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1511.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1522.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1531.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1541.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1551.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1562.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
1572.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1582.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
15990.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
1609.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
16190.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
1629.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
1631.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
164od71518/2023_2024 : Providing and fixing 4.00 mm (8 SWG ) dia copper wire on surface or in recess for loop earthing as required.
165od71519/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required.40A 10KA TP MCB (C curve)
166od71514/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. 63A 10KA TP MCB (C curve)
167od71520/2023_2024 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required
168od71522/2023_2024 : 'Supplying and fixing of following ways, vertical type, 415 V, TPN, sheet steel, MCB distribution board conforming to IEC 61439-3 (IP 43) on surface / in recess, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, neutral bus bar, earth bar, provision for fixing 4-pole MCCB as incomer, din bar for mounting MCBs (But without MCBs and incomer), prefitted masking sheet, interconnections etc as required.6 way (8+12) double door TPN VDB.
169od71524/2023_2024 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
170od71529/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.20W LED Tube light
171od71525/2023_2024 : 2.14LMRSupply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.2'x2'LED Square Panel downlight.(36W)
172od71526/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types oflight fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.12W LED Downlight(Round)
173od71527/2023_2024 : Supplying and fixing of following sizes of flexible conduit along with accessories in surface/recessas required.(16/ 20mm.)
174od71528/2023_2024 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
175BIO MEDICAL- OT 08
176od71500/2023_2024 : OT LIGHT:Double domeTechnical Specifications for Double dome LED Surgical light with monitor.The following technical specifications should be considered as mandatory features: If any point does not fit, offer will not be evaluated.• Equipment should be CE marked / BIS• The spare parts availability must be 10 years after the date of the installation• The manufacturer must have at least 15 years of experience and expertise in the manufacture of surgical light and a minimum of 5 years in the use of LEDs in this product• Light should be provided with frontal arms for low ceiling height• The LED’s must be of a single color only for long term maintenance and ease of replacement.• Should have a average radiant energy of the lights should be less than 3.9 mW/m2• Double dome light unit incorporating latest LED technology, with shadow less operating light field should be offered.• Should have continuous LUX intensity of maximum 160,000• Should have HECOL technology to produce light beams for perfect visualization on surface as well as in deep cavities.• Central illuminance at D10 and D50 >130,000 lux• Should have ambient light for endoscopy.• Should have adjustable color temp, from 3900°K to 4500°K• Depth of illumination L1+L2 (60%) 500 mm• Depth of illumination L1+L2 (20%) 1050 mm• larger field diameter 25 cm (D10)• Lifetime of the LED 60 000 hours without loss of efficiency.• Color rendering index Ra>95• Color rendering index R9>90• Sterile control of settings (Intensity or Diameter or Color Temp.) for surgical team• Should have a management system that ensure constant quality of light (Intensity, Color rendering index, Color Temp.) throughout the length of the surgery.• Should have stable illumination through the life period of the light.• Excellent shadow dilution: remaining illumination should be at least 60,000Lux in the worst case.• Protection degree against dust and liquid projections IP44• The lights should be cool lights and temperature at the surgical field should not increase more than 1 degree at 1.60,000 lux with regards to the temperature outside the surgicalfield. If demanded, vendor will have to prove the same during the lifetime of the equipment failing which downtime penalty clause will be applicable till the same is adhered to • Adjustable field diameter without any mechanical movementManufacturer: GETTINGE/ CARLSTORZ/DRAGER/DR. MACH
177od71502/2023_2024 : X-ray Viewer:X-Ray View box -LED Dual Screen 1000x400mmwith dipping function with ON/OFF button.
178od71505/2023_2024 : Writing Board: Size: about 1000mm x 700mmx 60mm deep Writing board should be made of ceramic having Magnetic properties and should be flushed to the wall of the operation room.
179od71497/2023_2024 : Sliding Door: Automated Single Leaf Sliding Door 1800 mm HPLAutomated Single Leaf Sliding Door 1800 x 2100 mm. Sliding door: The sliding door system size of single leaf according to the Operating room size the requirements in accordance with the Machine Directive 2006/42/EU, DIN 18650 and DIN / EN 16005 and is made up of the following main components:Automatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments. It should have a palm sensor for half opening and foot switch for full opening patient entry. Sliding door substructure: The sliding door substructure forms the transition between wall and door. It connects the running gear to the wall and ensures increased reinforcement, for profile walls, in the area of the sliding door. Door frame: The door frames are manufactured from 55/highpressure Aluminum frame. The one- leaf sliding door is designed with a ramp frame in order to prevent a shearing point. The closing edgesare fittedwithsurroundinggreysealprofiles(RAL 7016). Thedoorframeisfittedwith fillerthat is adhered to the entire surface. Door leaf: The door leaf has a thickness of minimum 40 mm. It is made up of a High Pressure Laminatefullygluedtubular chipboard or hard foam panel.Thehandle is astainless steel bow-type handle on both sides. The door should have a viewing glass of minimum 300 x 300 with motorized blinds.Runninggear,manualorElectrictherunning gearismadeupofanaluminumprofilewhich carries the functional parts and a rail profile for the roller wagon. The castor carriages are fitted with ball-bearing mounted plastic castors and connect the running gear to the door leaf. The fold- out casing of the runninggear is made from powder-coated CrNi steel and may be locked with a holding bar for maintenance work. Sliding Door shall have certificate in accordance with International standards e.g.: CE/TUV etc. Manufacturer: METAFLEX/DRAGER
180od71499/2023_2024 : OT Control Panel: Touch Screen Control Panel to control Humidity, Temperature, Gas Alarm, Clock, Lighting Control. Control panel should have minimum 22” touch screen within the theatre and will be located on theatre wall. The time elapsed digital clock and real time digital clocks shall have high brightness characters, the medical gas alarm will indicate High and Low gas pressure for each gas service present in the operating theatre and will have an audible buzzer with mute facility. The medical gas alarms will be connected to locai pressure switches located downstream of the last isolation valves.Each control panel should have display for Time elapse clock, Standard Clock, Temperature and Humidity, Clean room luminaries, Telephone, Medical Gas Alarms and HEPA filter status. We should be able to change the temperature and humidity of the OT as per daily / case to case basis requirement. This AC temperature control should be available either on the control panel or as a separate panel on the wall inside the operating room. The temperature and humidity sensing should be done from as near the operating table area as possible.Manufacturer: GETTINGE/DRAGER/DR. MACH
181od71501/2023_2024 : Air Extraction: Exhaust grills with filtersThe exhaust grills should be connected to the air extraction cabinets placed at the 4 Corners of the OR. Each corner grill should be made of SS 304 duly powder coated of the same colour shade as wall pannel. The installation should be flush mounted to the wall panel. The return air grills should have a fluff filters. Minimum size of the grill should be 450 x 450 mm.
182od71503/2023_2024 : Laminar Air Flow: SS Laminar Plenum Box with HEPA Filters & CG Screen 2400 x 2400 mm.Plan air Ceiling constructed out of SS304 of size 2400 x 2400 mm having 8 nos of HEPA Filters. Sufficient number of pre-filters to be provided that would maintain the efficiency of HEPA filters. The HEPA filters should have dust spot efficiency of 99.97% for 0.3 micron particles. Air diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air. Number of air changes should be such that Clean room classification can be maintained at Class 100, as per ISO 14644.
183od71504/2023_2024 : Flooring: Conductive Flooring: Electro Static Discharge (ESD) Control Flooring is a conductive flexible homogeneous vinyl floor covering available in sheet form. The 2 mm homogeneous material incorporates carbon encapsulated granules throughout its full thickness and has a conductive backing to ensure optimal and consistent conductive properties throughout its full life expectancy. It has permanent antistatic properties (< 20 V).It acts as a continuous conductive 5.104 ≤ Rt ≤ 106 (EN 1081) and complies with EN 649. The product is non-reactive to residual indentation with a value ≤ 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-sl fire resistance. The product is non-emissive of volatile organic compounds with <10 µg/m3 (TVOC after 28 days ISO 16000-6).
184od71506/2023_2024 : Ceiling Panels: Ceiling element steel size of600 x 1200mmsheetMaterial no. 1.0347should be in accordance with DIN /EN 10152.The ceiling system is made up of removable ceiling cassette chamfered all round, fromgalvanized/steelsheetwithathicknessof0.7 mm- 1.0mm. Thevisiblesideis coatedwith a white polyurethane powder-based finish (RAL9016). For restructuring purposes these ceiling cassettes can simply be disassembled and then reinstalled.The ceiling cassettes are secured by means of a self-locking system onto clamp rails and by means ofseal-tightassemblyinlongitudinaldirection.The ceiling cassettesareprovidedwith circumferential sealing. The joint is provided in transverse directionwithan HTV silicone joint profilefor opticalcontinuousclosure.Thesuspensionheightoftheceilingcanbeadjustedby suspending means with tension springs.Itshouldbe similarly prefabricatedinthefactory andfulfil the requirements offlexibility such that itshould be possible to remove the individual panels individually with the exception of the edge panels. It should be secured with a locking system and perfect sealing. The joints should be providedwith asiliconesealingforacontinuousclosure.Itshouldbestableandnonslipafter adjustment. Allsides of the panels should have folded edges.
185od71507/2023_2024 : Wall Paneling- Stainless Steel Prefabricated Walls- Single /double part Wall panel elements are made up of powder-coated CrNi steel Material no. 1.4301 with a minimum thickness of 0.8 mm to 1.0 mm backed by 15 - 18mm Gypsum Plasterboard . It should be tested & certified according to EN / DIN 10088-3. The wall panels are chamfered all round and should have 18 mm Fire rated Gypsum plasterboard glued to the entire rear side. The total distance between the inside and outside surfaces of the operating room should be variable to suit the layout, but should be sufficient for the flush mounting of equipment. The cavity between the inner and outer walls should be left with minimum obstructions for the possible addition of equipment at a later date and to enable services, pipes, conduits etc., to be run within the cavity, Sound insulation value 47- 64 Rw [dB].The individual wall panels should be made of single / double sheet with the width of 900-1200mm. The individual wall panels should be attached to each other with removable clamps or screws or an equivalent fastening system which will allow fast installation as well as removal for service. Welding of wall panels on site will not be permitted. The joints should be covered with removable and reusable silicone Gasket such that there is continuity in walls visually. Liquid silicone should not be used for sealing.All wall-mounted equipment should be flush mounted. The wall panel design andconstruction should allow for the installation and support of all equipment and the provision of openings required for installations, without affecting rigidity and strength.Joint profile between the wall elements HTN silicone gasket with antimicrobial properties.There should not be any sharp edges and corners should be smoothened. A shell type substructure should be designed as a non-load bearing wall.Once fixed they have to provide complete hygienic sealing. The prefabricated wall panels should be coated at the factory itself. It should have high heat stability and it should be highly durable against mopping. The coating should be done at the factory of origin of the panel and it should not be done at site. Shade of coating should be confirmed with the user department. Resistance against recommended hospital cleaning and disinfection agents must be ensured. Certification from regulatory authorities is essential.The mounting of the wall elements to the substructure is carried out via clamps that are attached to the wall elements and screwed to the support. The wall elements, when fixed, provide a hermetic and hygienic circumferential and sealed connection. The joint between the wall elements is closed with a removable joint profile made of colour coded HTV silicone.Antibacterial coating: Mixed powder paint on epoxy-polyester resin basis, in accordance withDIN67530, silk matte, gloss level 60°, layer thickness 90 - 120 pm. Antibacterial to be powder coating on SS test certificate should be duly submittd.Sound insulation: Without any additional measures the sound insulation values have to be aminimum of 45dB. Test reports of sound insulation will be required.Fire protection: The wall system (panels and substructure) should be made of non-flammable material. No dangerous concentrations of gases should be produced in an event of fire. It should confirm to Class A2-S1,d0.Substructure:The profile with connection to the raw ceiling supports are made of galvanized square steel pipe with min 2 mm thickness.The floor rails comprise profiled, 1.5 mm galvanised steel plates. The floor rails aremounted using clamp plates and screws with dowels into screed or threaded rods with dowels into the unfinished floor.Ceiling railThe ceiling rail is made of white-painted (RAL9016) aluminium extruded profile and acts asa mount for the ceiling cassette which is coordinated in colour. The upper wall element and the ceiling cassette are inserted into the opening of the ceiling rail and sealed.
186od71512/2023_2024 : Hinged Door [A]:Manual Hinged Door HPL 1500*2100The Hinged door should be made up of High Pressure laminate or PPGI with minimum thickness of 35 - 40mm. The door frame should be made up of aluminum Powder coated or Stainless steel.The door accessories such as door handle and viewing lead glass should be provided.
187od71516/2023_2024 : Hinged Door [A]:Manual Hinged Door HPL 900*2100The Hinged door should be made up of High Pressure laminate or PPGI with minimum thickness of 35 - 40mm. The door frame should be made up of aluminum Powder coated or Stainless steel.The door accessories such as door handle and viewing lead glass should be provided.
188od71509/2023_2024 : Cleanroom Ambient Lights: LED Peripheral Light cum clean room (OT) luminaries confirms to EN Electrical certifications Should give a total of 1500lx luminescence in operating area and 1000 lx in other peripheral areas with steeples, flicker less dimming control down to 5% level. There shall be two minimum independent circuits. They should be surface-mounted and recessed lights. Framed light cover should be made of highly-resistant and disinfectant - consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly-specular reflectors, cumulative reflection coated, Body should consist of sheet steel with mechanical and electrical removable carrier equipment Protection IP 65. The colour temperature of the lights should be 4000k minimum.
189od71511/2023_2024 : Cabinet:Size 2100mm x 1200mm x 400mm deep. The storage unit made from 1.5mm of stainless steel of SS304 grade. The doors shutter of the storage cabinet should have glass, should be installed on the storage units with the help of fittings allowing an opening allowance of at least 160. The storage unit should be divided in 2 equal parts and each part should have individual doors with stopper system.Each part should be provided with glass racks as per user department, and should be adjustable type.
190od71515/2023_2024 : "Double Station Surgical Scrub Sink. (Fully Automatic0* Completely Made of Stainless Steel 304 Grade Mat # 4 Finish Sheets & Tubes.* Perforated Drain Board.* Two No of Sensor Operated Water Taps.* Two No of Knee Operated Water Taps.* Two No of Sensor Operated Soap Dispenser.* One No of Lbow Operated Soap Dispenser.* Sink Panal SS Black Powder Cotting Model.* Water Flow is Shower Mode.* Wall Hanging Bracket.* Soap Tank Capacity 5Ltr.* Curved Joints to Avoid Microbial Deposition and Growth, Ensuring Perfect Hygiene and Easy of Cleaning.The Hospital Pattern (HTM64) Trough has fully Radius Internal Corners for Easy of Cleaning and Hygiene.* The Unit is Wall Mounted.* Welded Fabrication in Tungston Gas."
191od71513/2023_2024 : OT Pendent [Anesthesia]: Pendant Shall Conform to DIN EN ISO11197:2005.Each Ceiling Suspended Pendant Systemhave: Horizontal Double Arm Combination will be 900mm- 600 mm extending to total 1500mm.The swivel arm, carrying the supply column,maximum degree of rotary motion 300” in the horizontal plane and able to hold a weight of about 200 kg. The distribution column of at least 800mmin height. Minimum clearance from finished floor to bottom of pendant must be about 600-700 mm, 3 platforms of about 40cms x 50cms. Itmust allow gap of up to 25cms. Must include one drawer mechanism. Each platform must have weight bearing capacity of more than 50 Kg Each. Must have dual IV rod stand with a capacity of about 20 Kg with infusion management system With 2 vertical tubes, for mounting of infusion and syringe pumps. The following medical gas outlets must be provided on the back of the service head. It shall be DIN Standard/EN / HTM / NFPA standard & CE marked / UL Listed.i. O2 - 2 Nosii. Nitrous Oxide - 1 Noiii.Vacuum -2Nosiv. Medical Air- 1 Nov. AGSS (Venturi Type) -1 No. All Gas Outlets must come fitted from the factory.8 electrical sockets should be provided on the service head and UPS power (all 6/16Amp).These must be compatible to the Indian plugs. Must have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height. The pendant must have a Friction or Pneumatic braking system. The pendant must have a safety mechanism with internal isolation between gas and electrical services. All Gas Outlets must come fitted from the factory.8 electrical sockets should be provided on the service head and UPS power (all 6/16Amp).These must be compatible to the Indian plugs. Must have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height. The pendant must have a Friction or Pneumatic braking system. The pendant must have a safety mechanism with internal isolation between gas and electrical services. Manufacturer: GETTINGE/DRAGER/DR. MACH
192od71517/2023_2024 : OT Pendent [Surgery]: Pendant Shall Conform to DIN / EN ISO 11197:2005.Each Ceiling Suspended Pendant System should have:Horizontal Double Arm Combination will be 900mm- 600 mm extending to total 1500mm.The2swivelarms,carryingthesupplycolumn,shouldhavethemaximumdegreeofrotary motion 300* in the horizontal plane and should be able to hold a weight of about 200 kg.The distribution column should be at least 800 -1200 mm in height.Minimum clearance from finished floor to bottom of pendant should be about 600-700 mm.Should have 3 platforms of about 40cms x 50cms. It should allow gap of up to 75cms.Each platform should have weight bearing capacity of more than 50 Kg Each.The following medical gas outlets should be provided on the back of the service head. It shall be DIN Standard / HTM standard / NFPA standard with CEmarked / UL Listed.i. O2 -2Noiii.Vacuum -2 Nosiv. Compressed air supply - 1 Nov. Medical Air- 1 novi. Motor Air 7 Bar - 1 Novii.CO2 - 1No. All Gas Outlets should come fitted from the factory.10 electrical sockets should be provided on the service head (6 on each side). These should be compatible to the Indian plugs. Should have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height.The pendant should have a Friction or Pneumatic braking system.The pendant should have a safety mechanism with internal isolation between gas and electrical services. The pendant should have a provision to mount 32" monitor with swivelling up-down/right-left function.Mainmaterialused shouldbe ofhigh strength aluminum alloy, withasealeddesign, surface having antimicrobial and antifungal coating. Resistance against common hospital or manufactured recommended cleaning and disinfection agents must be ensured. It shall be CE marked.The Medical Gas Outlets Points on the pendants should be duly CE marked. It should have Integral check valve, should allow removal of the housing and socket assemblies formaintenance without closing down the entire pipeline and each outlet should be individually tested. Each of the gas specific components must have the gas service engraved onto it to ensure safety and compliance with standard.Should have safety features which eliminate the risk of connecting a socket assembly of one gas to the terminal block of another, either during installation or maintenance. All Gas Outlets should come fitted from the factory.10 electrical sockets should be provided on the service head (6 on each side). These should be compatible to the Indian plugs. Should have 4 low voltage terminals with low voltage wiring. The length of the drop tube from the extension arm should be suitable to the OT height.The pendant should have a Friction or Pneumatic braking system.The pendant should have a safety mechanism with internal isolation between gas and electrical services. The pendant should have a provision to mount 32" monitor with swivelling up-down/right-left function.Mainmaterialused shouldbe ofhigh strength aluminum alloy, withasealeddesign, surface having antimicrobial and antifungal coating. Resistance against common hospital or manufactured recommended cleaning and disinfection agents must be ensured. It shall be CE marked.The Medical Gas Outlets Points on the pendants should be duly CE marked. It should have Integral check valve, should allow removal of the housing and socket assemblies formaintenance without closing down the entire pipeline and each outlet should be individually tested. Each of the gas specific components must have the gas service engraved onto it to ensure safety and compliance with standard.Should have safety features which eliminate the risk of connecting a socket assembly of one gas to the terminal block of another, either during installation or maintenance. Manufacturer: GETTINGE/DRAGER/DR. MACH
193HVAC- OT 08
194od71496/2023_2024 : Supplying and fixing of following thickness closed cell Nitrile rubber (Class “O”) insulation with anti microbial protection .13 mm
195od71498/2023_2024 : "ALUMINIUM DUCTING AND INSULATION: Supply, installation balancing and commisnioning of Aluminium rectangularducting as per approved drawings & specification of following sheet thickness. Thickness 22 Gauge"
196GRAND TOTAL
197EXCLUSIVE OF GST
198TERMS AND CONDITIONS 1.Vendor should comply the specification for OT as per NABH standards for superspeciality OT. 2.Hospital will provide independent UPS and isolation transformer for each OT and vendor will fix independent distributuiuon pannel for each OT 3.Hospital should terminate all medical gases to be connected to anaethesuia and surgen pendents near the opeartion theatre and vedor will have to integrate these medical gas lines with theappropriate copper pipe to the pendents.Vendor will be responsible to complete all medical gas pipelines inside the operation theaters. 4. Vendor should have previous experience in implementing similar modular operation thetares. 5. Vendor should be able to demonstrate modular OT should the hospital require to do so. 6. Vendor should attach the list of previous installations.
199Note :1 All materials,Items, Equipment shall be best branded items with IS and approved byclient/KEL
2002:Rate should be inclusive ofInsurance,Transportation, delivery and installation cost for all items
2013.Rate should be Exclusive of GST.
2024.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
2035.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
2046.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
2057.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
2068.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
2079. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of flooras per DSR/PRICE has to be considered)
20810.VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
20911.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
21012. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
21113.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
212Make of Electrical equipments/materials
213All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
214Panel Boards: CPRI certified reputedmanufacturers make
215MCB/ELCB/DB -L&T/LEGRAND/SCHNEIRDER or equivalent
216Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
217Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRANDor equivalent
218Cable Glands & Sockets - REPUTED MAKE , Cosmos
219Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneideror equivalent